1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
|
<?xml version="1.0" standalone="no"?>
<!DOCTYPE article PUBLIC "-//OASIS//DTD DocBook XML V4.4//EN"
"http://www.oasis-open.org/docbook/xml/4.4/docbookx.dtd"
[
]>
<article id="index">
<articleinfo>
<title>D-Bus Tutorial</title>
<releaseinfo>Version 0.5.0</releaseinfo>
<date>20 August 2006</date>
<authorgroup>
<author>
<firstname>Havoc</firstname>
<surname>Pennington</surname>
<affiliation>
<orgname>Red Hat, Inc.</orgname>
<address><email>hp@pobox.com</email></address>
</affiliation>
</author>
<author>
<firstname>David</firstname>
<surname>Wheeler</surname>
</author>
<author>
<firstname>John</firstname>
<surname>Palmieri</surname>
<affiliation>
<orgname>Red Hat, Inc.</orgname>
<address><email>johnp@redhat.com</email></address>
</affiliation>
</author>
<author>
<firstname>Colin</firstname>
<surname>Walters</surname>
<affiliation>
<orgname>Red Hat, Inc.</orgname>
<address><email>walters@redhat.com</email></address>
</affiliation>
</author>
</authorgroup>
</articleinfo>
<sect1 id="meta">
<title>Tutorial Work In Progress</title>
<para>
This tutorial is not complete; it probably contains some useful information, but
also has plenty of gaps. Right now, you'll also need to refer to the D-Bus specification,
Doxygen reference documentation, and look at some examples of how other apps use D-Bus.
</para>
<para>
Enhancing the tutorial is definitely encouraged - send your patches or suggestions to the
mailing list. If you create a D-Bus binding, please add a section to the tutorial for your
binding, if only a short section with a couple of examples.
</para>
</sect1>
<sect1 id="whatis">
<title>What is D-Bus?</title>
<para>
D-Bus is a system for <firstterm>interprocess communication</firstterm>
(IPC). Architecturally, it has several layers:
<itemizedlist>
<listitem>
<para>
A library, <firstterm>libdbus</firstterm>, that allows two
applications to connect to each other and exchange messages.
</para>
</listitem>
<listitem>
<para>
A <firstterm>message bus daemon</firstterm> executable, built on
libdbus, that multiple applications can connect to. The daemon can
route messages from one application to zero or more other
applications.
</para>
</listitem>
<listitem>
<para>
<firstterm>Wrapper libraries</firstterm> or <firstterm>bindings</firstterm>
based on particular application frameworks. For example, libdbus-glib and
libdbus-qt. There are also bindings to languages such as
Python. These wrapper libraries are the API most people should use,
as they simplify the details of D-Bus programming. libdbus is
intended to be a low-level backend for the higher level bindings.
Much of the libdbus API is only useful for binding implementation.
</para>
</listitem>
</itemizedlist>
</para>
<para>
libdbus only supports one-to-one connections, just like a raw network
socket. However, rather than sending byte streams over the connection, you
send <firstterm>messages</firstterm>. Messages have a header identifying
the kind of message, and a body containing a data payload. libdbus also
abstracts the exact transport used (sockets vs. whatever else), and
handles details such as authentication.
</para>
<para>
The message bus daemon forms the hub of a wheel. Each spoke of the wheel
is a one-to-one connection to an application using libdbus. An
application sends a message to the bus daemon over its spoke, and the bus
daemon forwards the message to other connected applications as
appropriate. Think of the daemon as a router.
</para>
<para>
The bus daemon has multiple instances on a typical computer. The
first instance is a machine-global singleton, that is, a system daemon
similar to sendmail or Apache. This instance has heavy security
restrictions on what messages it will accept, and is used for systemwide
communication. The other instances are created one per user login session.
These instances allow applications in the user's session to communicate
with one another.
</para>
<para>
The systemwide and per-user daemons are separate. Normal within-session
IPC does not involve the systemwide message bus process and vice versa.
</para>
<sect2 id="uses">
<title>D-Bus applications</title>
<para>
There are many, many technologies in the world that have "Inter-process
communication" or "networking" in their stated purpose: <ulink
url="http://www.omg.org">CORBA</ulink>, <ulink
url="http://www.opengroup.org/dce/">DCE</ulink>, <ulink
url="http://www.microsoft.com/com/">DCOM</ulink>, <ulink
url="http://developer.kde.org/documentation/library/kdeqt/dcop.html">DCOP</ulink>, <ulink
url="http://www.xmlrpc.com">XML-RPC</ulink>, <ulink
url="http://www.w3.org/TR/SOAP/">SOAP</ulink>, <ulink
url="http://www.mbus.org/">MBUS</ulink>, <ulink
url="http://www.zeroc.com/ice.html">Internet Communications Engine (ICE)</ulink>,
and probably hundreds more.
Each of these is tailored for particular kinds of application.
D-Bus is designed for two specific cases:
<itemizedlist>
<listitem>
<para>
Communication between desktop applications in the same desktop
session; to allow integration of the desktop session as a whole,
and address issues of process lifecycle (when do desktop components
start and stop running).
</para>
</listitem>
<listitem>
<para>
Communication between the desktop session and the operating system,
where the operating system would typically include the kernel
and any system daemons or processes.
</para>
</listitem>
</itemizedlist>
</para>
<para>
For the within-desktop-session use case, the GNOME and KDE desktops
have significant previous experience with different IPC solutions
such as CORBA and DCOP. D-Bus is built on that experience and
carefully tailored to meet the needs of these desktop projects
in particular. D-Bus may or may not be appropriate for other
applications; the FAQ has some comparisons to other IPC systems.
</para>
<para>
The problem solved by the systemwide or communication-with-the-OS case
is explained well by the following text from the Linux Hotplug project:
<blockquote>
<para>
A gap in current Linux support is that policies with any sort of
dynamic "interact with user" component aren't currently
supported. For example, that's often needed the first time a network
adapter or printer is connected, and to determine appropriate places
to mount disk drives. It would seem that such actions could be
supported for any case where a responsible human can be identified:
single user workstations, or any system which is remotely
administered.
</para>
<para>
This is a classic "remote sysadmin" problem, where in this case
hotplugging needs to deliver an event from one security domain
(operating system kernel, in this case) to another (desktop for
logged-in user, or remote sysadmin). Any effective response must go
the other way: the remote domain taking some action that lets the
kernel expose the desired device capabilities. (The action can often
be taken asynchronously, for example letting new hardware be idle
until a meeting finishes.) At this writing, Linux doesn't have
widely adopted solutions to such problems. However, the new D-Bus
work may begin to solve that problem.
</para>
</blockquote>
</para>
<para>
D-Bus may happen to be useful for purposes other than the one it was
designed for. Its general properties that distinguish it from
other forms of IPC are:
<itemizedlist>
<listitem>
<para>
Binary protocol designed to be used asynchronously
(similar in spirit to the X Window System protocol).
</para>
</listitem>
<listitem>
<para>
Stateful, reliable connections held open over time.
</para>
</listitem>
<listitem>
<para>
The message bus is a daemon, not a "swarm" or
distributed architecture.
</para>
</listitem>
<listitem>
<para>
Many implementation and deployment issues are specified rather
than left ambiguous/configurable/pluggable.
</para>
</listitem>
<listitem>
<para>
Semantics are similar to the existing DCOP system, allowing
KDE to adopt it more easily.
</para>
</listitem>
<listitem>
<para>
Security features to support the systemwide mode of the
message bus.
</para>
</listitem>
</itemizedlist>
</para>
</sect2>
</sect1>
<sect1 id="concepts">
<title>Concepts</title>
<para>
Some basic concepts apply no matter what application framework you're
using to write a D-Bus application. The exact code you write will be
different for GLib vs. Qt vs. Python applications, however.
</para>
<para>
Here is a diagram (<ulink url="diagram.png">png</ulink> <ulink
url="diagram.svg">svg</ulink>) that may help you visualize the concepts
that follow.
</para>
<sect2 id="objects">
<title>Native Objects and Object Paths</title>
<para>
Your programming framework probably defines what an "object" is like;
usually with a base class. For example: java.lang.Object, GObject, QObject,
python's base Object, or whatever. Let's call this a <firstterm>native object</firstterm>.
</para>
<para>
The low-level D-Bus protocol, and corresponding libdbus API, does not care about native objects.
However, it provides a concept called an
<firstterm>object path</firstterm>. The idea of an object path is that
higher-level bindings can name native object instances, and allow remote applications
to refer to them.
</para>
<para>
The object path
looks like a filesystem path, for example an object could be
named <literal>/org/kde/kspread/sheets/3/cells/4/5</literal>.
Human-readable paths are nice, but you are free to create an
object named <literal>/com/mycompany/c5yo817y0c1y1c5b</literal>
if it makes sense for your application.
</para>
<para>
Namespacing object paths is smart, by starting them with the components
of a domain name you own (e.g. <literal>/org/kde</literal>). This
keeps different code modules in the same process from stepping
on one another's toes.
</para>
</sect2>
<sect2 id="members">
<title>Methods and Signals</title>
<para>
Each object has <firstterm>members</firstterm>; the two kinds of member
are <firstterm>methods</firstterm> and
<firstterm>signals</firstterm>. Methods are operations that can be
invoked on an object, with optional input (aka arguments or "in
parameters") and output (aka return values or "out parameters").
Signals are broadcasts from the object to any interested observers
of the object; signals may contain a data payload.
</para>
<para>
Both methods and signals are referred to by name, such as
"Frobate" or "OnClicked".
</para>
</sect2>
<sect2 id="interfaces">
<title>Interfaces</title>
<para>
Each object supports one or more <firstterm>interfaces</firstterm>.
Think of an interface as a named group of methods and signals,
just as it is in GLib or Qt or Java. Interfaces define the
<emphasis>type</emphasis> of an object instance.
</para>
<para>
DBus identifies interfaces with a simple namespaced string,
something like <literal>org.freedesktop.Introspectable</literal>.
Most bindings will map these interface names directly to
the appropriate programming language construct, for example
to Java interfaces or C++ pure virtual classes.
</para>
</sect2>
<sect2 id="proxies">
<title>Proxies</title>
<para>
A <firstterm>proxy object</firstterm> is a convenient native object created to
represent a remote object in another process. The low-level DBus API involves manually creating
a method call message, sending it, then manually receiving and processing
the method reply message. Higher-level bindings provide proxies as an alternative.
Proxies look like a normal native object; but when you invoke a method on the proxy
object, the binding converts it into a DBus method call message, waits for the reply
message, unpacks the return value, and returns it from the native method..
</para>
<para>
In pseudocode, programming without proxies might look like this:
<programlisting>
Message message = new Message("/remote/object/path", "MethodName", arg1, arg2);
Connection connection = getBusConnection();
connection.send(message);
Message reply = connection.waitForReply(message);
if (reply.isError()) {
} else {
Object returnValue = reply.getReturnValue();
}
</programlisting>
</para>
<para>
Programming with proxies might look like this:
<programlisting>
Proxy proxy = new Proxy(getBusConnection(), "/remote/object/path");
Object returnValue = proxy.MethodName(arg1, arg2);
</programlisting>
</para>
</sect2>
<sect2 id="bus-names">
<title>Bus Names</title>
<para>
When each application connects to the bus daemon, the daemon immediately
assigns it a name, called the <firstterm>unique connection name</firstterm>.
A unique name begins with a ':' (colon) character. These names are never
reused during the lifetime of the bus daemon - that is, you know
a given name will always refer to the same application.
An example of a unique name might be
<literal>:34-907</literal>. The numbers after the colon have
no meaning other than their uniqueness.
</para>
<para>
When a name is mapped
to a particular application's connection, that application is said to
<firstterm>own</firstterm> that name.
</para>
<para>
Applications may ask to own additional <firstterm>well-known
names</firstterm>. For example, you could write a specification to
define a name called <literal>com.mycompany.TextEditor</literal>.
Your definition could specify that to own this name, an application
should have an object at the path
<literal>/com/mycompany/TextFileManager</literal> supporting the
interface <literal>org.freedesktop.FileHandler</literal>.
</para>
<para>
Applications could then send messages to this bus name,
object, and interface to execute method calls.
</para>
<para>
You could think of the unique names as IP addresses, and the
well-known names as domain names. So
<literal>com.mycompany.TextEditor</literal> might map to something like
<literal>:34-907</literal> just as <literal>mycompany.com</literal> maps
to something like <literal>192.168.0.5</literal>.
</para>
<para>
Names have a second important use, other than routing messages. They
are used to track lifecycle. When an application exits (or crashes), its
connection to the message bus will be closed by the operating system
kernel. The message bus then sends out notification messages telling
remaining applications that the application's names have lost their
owner. By tracking these notifications, your application can reliably
monitor the lifetime of other applications.
</para>
<para>
Bus names can also be used to coordinate single-instance applications.
If you want to be sure only one
<literal>com.mycompany.TextEditor</literal> application is running for
example, have the text editor application exit if the bus name already
has an owner.
</para>
</sect2>
<sect2 id="addresses">
<title>Addresses</title>
<para>
Applications using D-Bus are either servers or clients. A server
listens for incoming connections; a client connects to a server. Once
the connection is established, it is a symmetric flow of messages; the
client-server distinction only matters when setting up the
connection.
</para>
<para>
If you're using the bus daemon, as you probably are, your application
will be a client of the bus daemon. That is, the bus daemon listens
for connections and your application initiates a connection to the bus
daemon.
</para>
<para>
A D-Bus <firstterm>address</firstterm> specifies where a server will
listen, and where a client will connect. For example, the address
<literal>unix:path=/tmp/abcdef</literal> specifies that the server will
listen on a UNIX domain socket at the path
<literal>/tmp/abcdef</literal> and the client will connect to that
socket. An address can also specify TCP/IP sockets, or any other
transport defined in future iterations of the D-Bus specification.
</para>
<para>
When using D-Bus with a message bus daemon,
libdbus automatically discovers the address of the per-session bus
daemon by reading an environment variable. It discovers the
systemwide bus daemon by checking a well-known UNIX domain socket path
(though you can override this address with an environment variable).
</para>
<para>
If you're using D-Bus without a bus daemon, it's up to you to
define which application will be the server and which will be
the client, and specify a mechanism for them to agree on
the server's address. This is an unusual case.
</para>
</sect2>
<sect2 id="bigpicture">
<title>Big Conceptual Picture</title>
<para>
Pulling all these concepts together, to specify a particular
method call on a particular object instance, a number of
nested components have to be named:
<programlisting>
Address -> [Bus Name] -> Path -> Interface -> Method
</programlisting>
The bus name is in brackets to indicate that it's optional -- you only
provide a name to route the method call to the right application
when using the bus daemon. If you have a direct connection to another
application, bus names aren't used; there's no bus daemon.
</para>
<para>
The interface is also optional, primarily for historical
reasons; DCOP does not require specifying the interface,
instead simply forbidding duplicate method names
on the same object instance. D-Bus will thus let you
omit the interface, but if your method name is ambiguous
it is undefined which method will be invoked.
</para>
</sect2>
<sect2 id="messages">
<title>Messages - Behind the Scenes</title>
<para>
D-Bus works by sending messages between processes. If you're using
a sufficiently high-level binding, you may never work with messages directly.
</para>
<para>
There are 4 message types:
<itemizedlist>
<listitem>
<para>
Method call messages ask to invoke a method
on an object.
</para>
</listitem>
<listitem>
<para>
Method return messages return the results
of invoking a method.
</para>
</listitem>
<listitem>
<para>
Error messages return an exception caused by
invoking a method.
</para>
</listitem>
<listitem>
<para>
Signal messages are notifications that a given signal
has been emitted (that an event has occurred).
You could also think of these as "event" messages.
</para>
</listitem>
</itemizedlist>
</para>
<para>
A method call maps very simply to messages: you send a method call
message, and receive either a method return message or an error message
in reply.
</para>
<para>
Each message has a <firstterm>header</firstterm>, including <firstterm>fields</firstterm>,
and a <firstterm>body</firstterm>, including <firstterm>arguments</firstterm>. You can think
of the header as the routing information for the message, and the body as the payload.
Header fields might include the sender bus name, destination bus name, method or signal name,
and so forth. One of the header fields is a <firstterm>type signature</firstterm> describing the
values found in the body. For example, the letter "i" means "32-bit integer" so the signature
"ii" means the payload has two 32-bit integers.
</para>
</sect2>
<sect2 id="callprocedure">
<title>Calling a Method - Behind the Scenes</title>
<para>
A method call in DBus consists of two messages; a method call message sent from process A to process B,
and a matching method reply message sent from process B to process A. Both the call and the reply messages
are routed through the bus daemon. The caller includes a different serial number in each call message, and the
reply message includes this number to allow the caller to match replies to calls.
</para>
<para>
The call message will contain any arguments to the method.
The reply message may indicate an error, or may contain data returned by the method.
</para>
<para>
A method invocation in DBus happens as follows:
<itemizedlist>
<listitem>
<para>
The language binding may provide a proxy, such that invoking a method on
an in-process object invokes a method on a remote object in another process. If so, the
application calls a method on the proxy, and the proxy
constructs a method call message to send to the remote process.
</para>
</listitem>
<listitem>
<para>
For more low-level APIs, the application may construct a method call message itself, without
using a proxy.
</para>
</listitem>
<listitem>
<para>
In either case, the method call message contains: a bus name belonging to the remote process; the name of the method;
the arguments to the method; an object path inside the remote process; and optionally the name of the
interface that specifies the method.
</para>
</listitem>
<listitem>
<para>
The method call message is sent to the bus daemon.
</para>
</listitem>
<listitem>
<para>
The bus daemon looks at the destination bus name. If a process owns that name,
the bus daemon forwards the method call to that process. Otherwise, the bus daemon
creates an error message and sends it back as the reply to the method call message.
</para>
</listitem>
<listitem>
<para>
The receiving process unpacks the method call message. In a simple low-level API situation, it
may immediately run the method and send a method reply message to the bus daemon.
When using a high-level binding API, the binding might examine the object path, interface,
and method name, and convert the method call message into an invocation of a method on
a native object (GObject, java.lang.Object, QObject, etc.), then convert the return
value from the native method into a method reply message.
</para>
</listitem>
<listitem>
<para>
The bus daemon receives the method reply message and sends it to the process that
made the method call.
</para>
</listitem>
<listitem>
<para>
The process that made the method call looks at the method reply and makes use of any
return values included in the reply. The reply may also indicate that an error occurred.
When using a binding, the method reply message may be converted into the return value of
of a proxy method, or into an exception.
</para>
</listitem>
</itemizedlist>
</para>
<para>
The bus daemon never reorders messages. That is, if you send two method call messages to the same recipient,
they will be received in the order they were sent. The recipient is not required to reply to the calls
in order, however; for example, it may process each method call in a separate thread, and return reply messages
in an undefined order depending on when the threads complete. Method calls have a unique serial
number used by the method caller to match reply messages to call messages.
</para>
</sect2>
<sect2 id="signalprocedure">
<title>Emitting a Signal - Behind the Scenes</title>
<para>
A signal in DBus consists of a single message, sent by one process to any number of other processes.
That is, a signal is a unidirectional broadcast. The signal may contain arguments (a data payload), but
because it is a broadcast, it never has a "return value." Contrast this with a method call
(see <xref linkend="callprocedure"/>) where the method call message has a matching method reply message.
</para>
<para>
The emitter (aka sender) of a signal has no knowledge of the signal recipients. Recipients register
with the bus daemon to receive signals based on "match rules" - these rules would typically include the sender and
the signal name. The bus daemon sends each signal only to recipients who have expressed interest in that
signal.
</para>
<para>
A signal in DBus happens as follows:
<itemizedlist>
<listitem>
<para>
A signal message is created and sent to the bus daemon. When using the low-level API this may be
done manually, with certain bindings it may be done for you by the binding when a native object
emits a native signal or event.
</para>
</listitem>
<listitem>
<para>
The signal message contains the name of the interface that specifies the signal;
the name of the signal; the bus name of the process sending the signal; and
any arguments
</para>
</listitem>
<listitem>
<para>
Any process on the message bus can register "match rules" indicating which signals it
is interested in. The bus has a list of registered match rules.
</para>
</listitem>
<listitem>
<para>
The bus daemon examines the signal and determines which processes are interested in it.
It sends the signal message to these processes.
</para>
</listitem>
<listitem>
<para>
Each process receiving the signal decides what to do with it; if using a binding,
the binding may choose to emit a native signal on a proxy object. If using the
low-level API, the process may just look at the signal sender and name and decide
what to do based on that.
</para>
</listitem>
</itemizedlist>
</para>
</sect2>
<sect2 id="introspection">
<title>Introspection</title>
<para>
D-Bus objects may support the interface <literal>org.freedesktop.DBus.Introspectable</literal>.
This interface has one method <literal>Introspect</literal> which takes no arguments and returns
an XML string. The XML string describes the interfaces, methods, and signals of the object.
See the D-Bus specification for more details on this introspection format.
</para>
</sect2>
</sect1>
<sect1 id="glib-client">
<title>GLib APIs</title>
<para>
The recommended GLib API for D-Bus is GDBus, which has been
distributed with GLib since version 2.26. It is not documented here.
See <ulink url="https://developer.gnome.org/gio/stable/gdbus-convenience.html">the
GLib documentation</ulink> for details of how to use GDBus.
</para>
<para>
An older API, dbus-glib, also exists. It is deprecated and should
not be used in new code. Whenever possible, porting existing code
from dbus-glib to GDBus is also recommended.
</para>
</sect1>
<sect1 id="python-client">
<title>Python API</title>
<para>
The Python API, dbus-python, is now documented separately in
<ulink url="http://dbus.freedesktop.org/doc/dbus-python/doc/tutorial.html">the dbus-python tutorial</ulink> (also available in doc/tutorial.txt,
and doc/tutorial.html if built with python-docutils, in the dbus-python
source distribution).
</para>
</sect1>
<sect1 id="qt-client">
<title>Qt API</title>
<para>
The Qt binding for libdbus, QtDBus, has been distributed with Qt
since version 4.2. It is not documented here. See
<ulink url="http://qt-project.org/doc/qt-5/qtdbus-index.html">the Qt
documentation</ulink> for details of how to use QtDBus.
</para>
</sect1>
</article>
|