diff options
| author | Yuri Pankov <yuri.pankov@nexenta.com> | 2017-07-29 16:02:29 +0300 |
|---|---|---|
| committer | Richard Lowe <richlowe@richlowe.net> | 2017-08-11 19:00:16 -0400 |
| commit | c66b8046543352459a11a51501b628d1c98a8c44 (patch) | |
| tree | 1121a5f9a15592e29af27c5f55a10ec607cf88d6 /usr/src/man/man1m | |
| parent | 12014b724f98604d61f9756b7e199416475d7396 (diff) | |
| download | illumos-joyent-c66b8046543352459a11a51501b628d1c98a8c44.tar.gz | |
8547 update mandoc to 1.14.3
Reviewed by: Robert Mustacchi <rm@joyent.com>
Approved by: Richard Lowe <richlowe@richlowe.net>
Diffstat (limited to 'usr/src/man/man1m')
| -rw-r--r-- | usr/src/man/man1m/automount.1m | 53 | ||||
| -rw-r--r-- | usr/src/man/man1m/ipadm.1m | 88 | ||||
| -rw-r--r-- | usr/src/man/man1m/lofiadm.1m | 8 | ||||
| -rw-r--r-- | usr/src/man/man1m/mount_nfs.1m | 10 | ||||
| -rw-r--r-- | usr/src/man/man1m/share_nfs.1m | 14 | ||||
| -rw-r--r-- | usr/src/man/man1m/stmfadm.1m | 42 | ||||
| -rw-r--r-- | usr/src/man/man1m/zdb.1m | 10 | ||||
| -rw-r--r-- | usr/src/man/man1m/zfs.1m | 22 | ||||
| -rw-r--r-- | usr/src/man/man1m/zpool.1m | 4 |
9 files changed, 115 insertions, 136 deletions
diff --git a/usr/src/man/man1m/automount.1m b/usr/src/man/man1m/automount.1m index 717d4fafe1..111e1a512c 100644 --- a/usr/src/man/man1m/automount.1m +++ b/usr/src/man/man1m/automount.1m @@ -17,7 +17,7 @@ .\" .\" Copyright 1989 AT&T .\" Copyright (c) 2008, Sun Microsystems, Inc. All Rights Reserved -.\" Copyright 2016 Nexenta Systems, Inc. +.\" Copyright 2017 Nexenta Systems, Inc. .\" .Dd February 25, 2017 .Dt AUTOMOUNT 1M @@ -205,7 +205,7 @@ and .Ar location takes the form: .Pp -.Dl Ar host Ns : Ns Ar pathname +.Dl Ar host Ns \&: Ns Ar pathname .Pp .Ar host is the name of the host from which to mount the file system, and @@ -259,7 +259,7 @@ then a single .Ar location may be used with a comma-separated list of hostnames: .Bd -literal -offset indent -.Ar hostname Ns , Ns Ar hostname Ns ...: Ns Ar pathname +.Ar hostname Ns \&, Ns Ar hostname Ns ...: Ns Ar pathname .Ed .Pp Requests for a server may be weighted, with the weighting factor appended to @@ -338,7 +338,7 @@ this would allow automatic mounts in .Pa /config of any remote file system whose location could be specified as: .Bd -literal -offset indent -.Ar hostname Ns : Ns Pa /export/config/ Ns Ar hostname +.Ar hostname Ns \&: Ns Pa /export/config/ Ns Ar hostname .Ed .Pp Note that the wildcard key does not work in conjunction with the @@ -356,42 +356,19 @@ would expand it to its current value for the client's host name. Supported variables are: .Bl -column "PLATFORM" "arch -k or uname -m" .It Sy NAME Ta Sy OUTPUT OF Ta Sy DESCRIPTION (EXAMPLE) -.It Ev ARCH -.Ta Nm arch -.Ta architecture name -.Pq Qq Sy sun4 -.It Ev CPU -.Ta Nm uname Fl p -.Ta processor type -.Pq Qq Sy sparc -.It Ev HOST -.Ta Nm uname Fl n -.Ta host name -.Pq Qq Sy myhost -.It Ev KARCH -.Ta Nm arch Fl k No or Nm uname Fl m -.Ta kernel architecture name or machine hardware name +.It Ev ARCH Ta Nm arch Ta architecture name Pq Qq Sy sun4 +.It Ev CPU Ta Nm uname Fl p Ta processor type Pq Qq Sy sparc +.It Ev HOST Ta Nm uname Fl n Ta host name Pq Qq Sy myhost +.It Ev KARCH Ta Nm arch Fl k No or Nm uname Fl m Ta kernel architecture name or +machine hardware name .Pq Qq Sy sun4u -.It Ev OSNAME -.Ta Nm uname Fl s -.Ta OS name -.Pq Qq Sy SunOS -.It Ev OSREL -.Ta Nm name Fl r -.Ta OS release name -.Pq Qq Sy 5.3 -.It Ev OSVERS -.Ta Nm uname Fl v -.Ta OS version -.Pq Qq Sy beta1.0 -.It Ev NATISA -.Ta Nm isainfo Fl n -.Ta native instruction set architecture for the system +.It Ev OSNAME Ta Nm uname Fl s Ta OS name Pq Qq Sy SunOS +.It Ev OSREL Ta Nm name Fl r Ta OS release name Pq Qq Sy 5.3 +.It Ev OSVERS Ta Nm uname Fl v Ta OS version Pq Qq Sy beta1.0 +.It Ev NATISA Ta Nm isainfo Fl n Ta native instruction set architecture for the +system .Pq Qq Sy sparcv9 -.It Ev PLATFORM -.Ta Nm uname Fl i -.Ta platform name -.Pq Qq Sy SUNW,Sun-Fire-V240 +.It Ev PLATFORM Ta Nm uname Fl i Ta platform name Pq Qq Sy SUNW,Sun-Fire-V240 .El .Pp If a reference needs to be protected from affixed characters, you can surround diff --git a/usr/src/man/man1m/ipadm.1m b/usr/src/man/man1m/ipadm.1m index dc3ea104c9..1a8ea8a54d 100644 --- a/usr/src/man/man1m/ipadm.1m +++ b/usr/src/man/man1m/ipadm.1m @@ -176,7 +176,7 @@ this can be one of the following values: .Cm tcp , .Cm sctp or -.Cm udp. +.Cm udp . .Sh SUBCOMMANDS The following subcommands are supported: .Bl -tag -width "" @@ -191,7 +191,7 @@ The interface will be enabled as part of the creation process. The IPv4 interface will have the address 0.0.0.0. The IPv6 interface will have the address ::. .Bl -tag -width "" -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -202,7 +202,7 @@ Temporary, not persistent across reboots. .Xc Disable an IP interface. .Bl -tag -width "" -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -213,7 +213,7 @@ Temporary, not persistent across reboots. .Xc Enable an IP interface. .Bl -tag -width "" -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -230,7 +230,7 @@ Permanently delete an IP interface. .Xc Show the current IP interface configuration. .Bl -tag -width "" -.It Fl o Ns , Ns Fl -output +.It Fl o Ns \&, Ns Fl -output Select which fields will be shown. The field value can be one of the following names: .Bl -tag -compact -width "PERSISTENT" @@ -292,7 +292,7 @@ IPv4 IPv6 .El .El -.It Fl p Ns , Ns Fl -parsable +.It Fl p Ns \&, Ns Fl -parsable Print the output in a parsable format. .El .It Xo @@ -305,9 +305,9 @@ Print the output in a parsable format. .Xc Set a property's value(s) on the IP interface. .Bl -tag -width "" -.It Fl m Ns , Ns Fl -module +.It Fl m Ns \&, Ns Fl -module Specify which protocol the setting applies to. -.It Fl p Ns , Ns Fl -prop +.It Fl p Ns \&, Ns Fl -prop Specify the property name and value(s). The property name can be one of the following: .Bl -tag -compact -width "exchange_routes" @@ -334,7 +334,7 @@ A value .Cm none may also be used. .El -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -347,14 +347,14 @@ Temporary, not persistent across reboots. .Xc Reset an IP interface's property value to the default. .Bl -tag -width "" -.It Fl m Ns , Ns Fl -module +.It Fl m Ns \&, Ns Fl -module Specify which protocol the setting applies to. -.It Fl p Ns , Ns Fl -prop +.It Fl p Ns \&, Ns Fl -prop Specify the property name. See the .Nm ipadm Ic set-ifprop subcommand for the list of property names. -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -367,11 +367,11 @@ Temporary, not persistent across reboots. .Xc Display the property values for one or all of the IP interfaces. .Bl -tag -width "" -.It Fl c Ns , Ns Fl -parsable +.It Fl c Ns \&, Ns Fl -parsable Print the output in a parsable format. -.It Fl m Ns , Ns Fl -module +.It Fl m Ns \&, Ns Fl -module Specify which protocol to display. -.It Fl o Ns , Ns Fl -output +.It Fl o Ns \&, Ns Fl -output Select which fields will be shown. The field value can be one of the following names: .Bl -tag -compact -width "PERSISTENT" @@ -397,7 +397,7 @@ The default value of the property. .It Cm POSSIBLE The possible values for the property. .El -.It Fl p Ns , Ns Fl -prop +.It Fl p Ns \&, Ns Fl -prop Specify which properties to display. See the .Nm ipadm Ic set-ifprop @@ -446,7 +446,7 @@ address configured on an interface is required to configure IPv6 address on the same interface. This takes the following options: .Bl -tag -width "" -.It Fl a Ns , Ns Fl -address +.It Fl a Ns \&, Ns Fl -address Specify the address. The .Cm local @@ -458,26 +458,26 @@ Otherwise, the equal sign .Pq Qq = should be omitted and the address should be provided by itself without second address. -.It Fl d Ns , Ns Fl -down +.It Fl d Ns \&, Ns Fl -down The address is down. .El .It Fl T Cm dhcp Obtain the address via DHCP. This takes the following options: .Bl -tag -width "" -.It Fl w Ns , Ns Fl -wait +.It Fl w Ns \&, Ns Fl -wait Specify the time, in seconds, that the command should wait to obtain an address. .El .It Fl T Cm addrconf Create an auto-configured address. This takes the following options: .Bl -tag -width "" -.It Fl i Ns , Ns Fl -interface-id +.It Fl i Ns \&, Ns Fl -interface-id Specify the interface ID to be used. -.It Fl p Ns , Ns Fl -prop +.It Fl p Ns \&, Ns Fl -prop Specify which method of auto-configuration should be used. .El -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -489,7 +489,7 @@ Temporary, not persistent across reboots. Down the address. This will stop packets from being sent or received. .Bl -tag -width "" -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -501,7 +501,7 @@ Temporary, not persistent across reboots. Up the address. This will enable packets to be sent and received. .Bl -tag -width "" -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -512,7 +512,7 @@ Temporary, not persistent across reboots. .Xc Disable the address. .Bl -tag -width "" -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -523,7 +523,7 @@ Temporary, not persistent across reboots. .Xc Enable the address. .Bl -tag -width "" -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -539,7 +539,7 @@ It also restarts duplicate address detection for .Cm static addresses. .Bl -tag -width "" -.It Fl i Ns , Ns Fl -inform +.It Fl i Ns \&, Ns Fl -inform Obtain network configuration from DHCP without taking a lease on the address. .El .It Xo @@ -550,7 +550,7 @@ Obtain network configuration from DHCP without taking a lease on the address. .Xc Delete the given address. .Bl -tag -width "" -.It Fl r Ns , Ns Fl -release +.It Fl r Ns \&, Ns Fl -release Indicate that the DHCP-assigned address should be released. .El .It Xo @@ -561,7 +561,7 @@ Indicate that the DHCP-assigned address should be released. .Xc Show the current address properties. .Bl -tag -width "" -.It Fl o Ns , Ns Fl -output +.It Fl o Ns \&, Ns Fl -output Select which fields will be shown. The field value can be one of the following names: .Bl -tag -compact -width "PERSISTENT" @@ -624,7 +624,7 @@ deprecated .It Cm ADDR The address. .El -.It Fl p Ns , Ns Fl -parsable +.It Fl p Ns \&, Ns Fl -parsable Print the output in a parsable format. .El .It Xo @@ -636,7 +636,7 @@ Print the output in a parsable format. .Xc Set a property's value(s) on the addrobj. .Bl -tag -width "" -.It Fl p Ns , Ns Fl -prop +.It Fl p Ns \&, Ns Fl -prop Specify the property name and value(s). The property name can be one of the following: .Bl -tag -compact -width "deprecated" @@ -656,7 +656,7 @@ Packets can be transmitted .It Cm zone The zone the addrobj is in. .El -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -668,12 +668,12 @@ Temporary, not persistent across reboots. .Xc Reset an addrobj's property value to the default. .Bl -tag -width "" -.It Fl p Ns , Ns Fl -prop +.It Fl p Ns \&, Ns Fl -prop Specify the property name. See the .Nm ipadm Ic set-addrprop subcommand for the list of property names. -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -685,9 +685,9 @@ Temporary, not persistent across reboots. .Xc Display the property values for one or all of the addrobjs. .Bl -tag -width "" -.It Fl c Ns , Ns Fl -parsable +.It Fl c Ns \&, Ns Fl -parsable Print the output in a parsable format. -.It Fl o Ns , Ns Fl -output +.It Fl o Ns \&, Ns Fl -output Select which fields will be shown. The field value can be one of the following names: .Bl -tag -compact -width "PERSISTENT" @@ -711,7 +711,7 @@ The default value of the property. .It Cm POSSIBLE The possible values for the property. .El -.It Fl p Ns , Ns Fl -prop +.It Fl p Ns \&, Ns Fl -prop Specify which properties to display. See the .Nm ipadm Ic set-addrprop @@ -726,7 +726,7 @@ subcommand for the list of property names. .Xc Set a property's value(s) on the protocol. .Bl -tag -width "" -.It Fl p Ns , Ns Fl -prop +.It Fl p Ns \&, Ns Fl -prop Specify the property name and value(s). The optional .Sy + Ns | Ns Sy - @@ -782,7 +782,7 @@ Smallest non-privileged port .It Cm ttl The IPv4 time-to-live. .El -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -794,12 +794,12 @@ Temporary, not persistent across reboots. .Xc Reset a protocol's property value to the default. .Bl -tag -width "" -.It Fl p Ns , Ns Fl -prop +.It Fl p Ns \&, Ns Fl -prop Specify the property name. See the .Nm ipadm Ic set-prop subcommand for the list of property names. -.It Fl t Ns , Ns Fl -temporary +.It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .It Xo @@ -811,9 +811,9 @@ Temporary, not persistent across reboots. .Xc Display the property values for one or all of the protocols. .Bl -tag -width "" -.It Fl c Ns , Ns Fl -parsable +.It Fl c Ns \&, Ns Fl -parsable Print the output in a parsable format. -.It Fl o Ns , Ns Fl -output +.It Fl o Ns \&, Ns Fl -output Select which fields will be shown. The field value can be one of the following names: .Bl -tag -compact -width "PERSISTENT" @@ -837,7 +837,7 @@ The default value of the property. .It Cm POSSIBLE The possible values for the property. .El -.It Fl p Ns , Ns Fl -prop +.It Fl p Ns \&, Ns Fl -prop Specify which properties to display. See the .Nm ipadm Ic set-prop diff --git a/usr/src/man/man1m/lofiadm.1m b/usr/src/man/man1m/lofiadm.1m index 750e2c732a..079caf2502 100644 --- a/usr/src/man/man1m/lofiadm.1m +++ b/usr/src/man/man1m/lofiadm.1m @@ -264,14 +264,14 @@ encryption key. .It Ar token_key PKCS#11 token object in the format: .Pp -.Ar token_name Ns : Ns Ar manufacturer_id Ns : Ns Ar serial_number Ns : Ns Ar key_label +.Ar token_name Ns \&: Ns Ar manufacturer_id Ns \&: Ns +.Ar serial_number Ns \&: Ns Ar key_label .Pp All but the key label are optional and can be empty. For example, to specify a token object with only its key label .Sy MylofiKey , -use: -.Pp -.Fl T Ar ::: Ns Ar MylofiKey +use +.Fl T Sy :::MylofiKey . .It Ar wrapped_key_file Path to file containing a symmetric encryption key wrapped by the RSA private key specified by diff --git a/usr/src/man/man1m/mount_nfs.1m b/usr/src/man/man1m/mount_nfs.1m index 4992fa1b7b..caf5d86175 100644 --- a/usr/src/man/man1m/mount_nfs.1m +++ b/usr/src/man/man1m/mount_nfs.1m @@ -17,7 +17,7 @@ .\" .\" Copyright 1989 AT&T .\" Copyright (c) 2009 Sun Microsystems, Inc. All Rights Reserved -.\" Copyright 2016 Nexenta Systems, Inc. +.\" Copyright 2017 Nexenta Systems, Inc. .\" .Dd March 12, 2016 .Dt MOUNT_NFS 1M @@ -102,7 +102,7 @@ See and .Xr inet6 7P . .Bl -tag -width Ds -.It Ar host Ns : Ns Ar pathname +.It Ar host Ns \&: Ns Ar pathname Where .Ar host is the name of the NFS server host, and @@ -122,12 +122,12 @@ See the discussion of URLs and the public option under .Sx NFS FILE SYSTEMS for a more detailed discussion. .It Xo -.Ar host Ns : Ns Ar pathname +.Ar host Ns \&: Ns Ar pathname .No nfs:// Ns Ar host Ns Oo : Ns Ar port Oc Ns / Ns Ar pathname .Xc -.Ar host Ns : Ns Ar pathname +.Ar host Ns \&: Ns Ar pathname is a comma-separated list of -.Ar host Ns : Ns Ar pathname . +.Ar host Ns \&: Ns Ar pathname . See the discussion of replicated file systems and failover under .Sx NFS FILE SYSTEMS for a more detailed discussion. diff --git a/usr/src/man/man1m/share_nfs.1m b/usr/src/man/man1m/share_nfs.1m index 8a2770cb79..c79b6b9438 100644 --- a/usr/src/man/man1m/share_nfs.1m +++ b/usr/src/man/man1m/share_nfs.1m @@ -109,9 +109,9 @@ some other local user. For clients where the gid in the incoming request is .Ar clnt and the client matches the -.Ar access_list Ns -, change the group ID to -.Ar srv Ns . +.Ar access_list , +change the group ID to +.Ar srv . If .Ar clnt is asterisk (*), all groups are mapped by this rule. @@ -329,9 +329,9 @@ some other local user. For clients where the uid in the incoming request is .Ar clnt and the client matches the -.Ar access_list Ns -, change the user ID to -.Ar srv Ns . +.Ar access_list , +change the user ID to +.Ar srv . If .Ar clnt is asterisk (*), all users are mapped by this rule. @@ -553,7 +553,7 @@ The following example remaps the user with uid at client .Sy 10.0.0.1 to user -.Sy joe Ns : +.Sy joe : .Bd -literal -offset indent share -o uidmap=100:joe:@10.0.0.1 /export .Ed diff --git a/usr/src/man/man1m/stmfadm.1m b/usr/src/man/man1m/stmfadm.1m index d99c31c3b3..1444e35832 100644 --- a/usr/src/man/man1m/stmfadm.1m +++ b/usr/src/man/man1m/stmfadm.1m @@ -16,7 +16,7 @@ .\" .\" .\" Copyright (c) 2009, Sun Microsystems, Inc. All Rights Reserved -.\" Copyright 2016 Nexenta Systems, Inc. +.\" Copyright 2017 Nexenta Systems, Inc. .\" .Dd March 1, 2016 .Dt STMFADM 1M @@ -247,7 +247,7 @@ Add a host group member to a host group. .Pp An initiator cannot be a member of more than one host group. .Bl -tag -width Ds -.It Fl g Ns , Ns Fl -group-name Ar host-group +.It Fl g Ns \&, Ns Fl -group-name Ar host-group Specifies group name. .Ar host-group must be an existing group created using the @@ -264,7 +264,7 @@ Add a target group member to a target group. .Pp A target cannot be a member of more than one target group. .Bl -tag -width Ds -.It Fl g Ns , Ns Fl -group-name Ar target-group +.It Fl g Ns \&, Ns Fl -group-name Ar target-group Specifies group name. .Ar target-group must be an existing group created using the @@ -300,20 +300,20 @@ and .Cm remove-view subcommands. .Bl -tag -width Ds -.It Fl h Ns , Ns Fl -host-group Ar host-group +.It Fl h Ns \&, Ns Fl -host-group Ar host-group .Ar host-group is the name of an host group previously created using .Cm create-hg subcommand. If this option is not specified, the logical unit will be available to all initiators that log in to the STMF framework. -.It Fl n Ns , Ns Fl -lun Ar lu-number +.It Fl n Ns \&, Ns Fl -lun Ar lu-number .Ar lu-number is an integer in the range 0-16383 to be assigned to the logical unit for this view entry. If this option is not specified, a logical unit number will be assigned by the STMF framework. -.It Fl t Ns , Ns Fl -target-group Ar target-group +.It Fl t Ns \&, Ns Fl -target-group Ar target-group .Ar target-group is the name of a target group previously created using .Cm create-tg @@ -365,12 +365,12 @@ subcommand to specify an alternate file to contain the metadata. It is advisable to use a file that can provide sufficient storage of the logical unit metadata, preferably 64k. .Bl -tag -width Ds -.It Fl p Ns , Ns Fl -lu-prop Ar property Ns = Ns Ar value +.It Fl p Ns \&, Ns Fl -lu-prop Ar property Ns = Ns Ar value Set specified logical unit property. Check .Sx Logical Unit Properties for the list of available properties. -.It Fl s Ns , Ns Fl -size Ar size +.It Fl s Ns \&, Ns Fl -size Ar size .Ar size is an integer followed by one of the following letters, to indicate a unit of size: @@ -407,7 +407,7 @@ subcommand. This effectively unloads the logical unit from the STMF framework. Any existing data on the logical unit remains intact. .Bl -tag -width Ds -.It Fl k Ns , Ns Fl -keep-views +.It Fl k Ns \&, Ns Fl -keep-views Keep view entries for this logical unit. .El .It Xo @@ -449,7 +449,7 @@ If .Ar host-group is not specified, all host groups in the system will be listed. .Bl -tag -width Ds -.It Fl v Ns , Ns Fl -verbose +.It Fl v Ns \&, Ns Fl -verbose Display all host group members. .El .It Xo @@ -464,7 +464,7 @@ If .Ar lu-name is not specified, all logical units in the system will be listed. .Bl -tag -width Ds -.It Fl v Ns , Ns Fl -verbose +.It Fl v Ns \&, Ns Fl -verbose Display verbose information about the logical unit. .El .It Xo @@ -482,7 +482,7 @@ List information for the target port in the system referenced by .Ar target . If target name is not specified, all target ports in the system will be listed. .Bl -tag -width Ds -.It Fl v Ns , Ns Fl -verbose +.It Fl v Ns \&, Ns Fl -verbose Display verbose information about the target along with SCSI session information for logged-in initiators. .El @@ -498,7 +498,7 @@ If .Ar target-group is not specified, all target groups in the system will be listed. .Bl -tag -width Ds -.It Fl v Ns , Ns Fl -verbose +.It Fl v Ns \&, Ns Fl -verbose Display all group members. .El .It Xo @@ -514,7 +514,7 @@ If is not specified, all view entries for the specified logical unit will be listed. .Bl -tag -width Ds -.It Fl l Ns , Ns Fl -lu-name Ar lu-name +.It Fl l Ns \&, Ns Fl -lu-name Ar lu-name Specify logical unit. .El .It Xo @@ -535,18 +535,18 @@ is not specified, is interpreted as .Ar lu-name. .Bl -tag -width Ds -.It Fl f Ns , Ns Fl -file +.It Fl f Ns \&, Ns Fl -file If specified, .Ar lu-arg is interpreted as file name. This provides the ability to modify a logical unit that is not currently imported into the STMF. -.It Fl p Ns , Ns Fl -lu-prop Ar property +.It Fl p Ns \&, Ns Fl -lu-prop Ar property Modify specified logical unit property. See .Sx Logical Unit Properties for the list of available properties. -.It Fl s Ns , Ns Fl -size Ar size +.It Fl s Ns \&, Ns Fl -size Ar size .Ar size is an integer followed by one of the following letters, to indicate a unit of size: @@ -588,7 +588,7 @@ Remove specified .Ar initiator from host group .Bl -tag -width Ds -.It Fl g Ns , Ns Fl -group-name Ar host-group +.It Fl g Ns \&, Ns Fl -group-name Ar host-group Specifies group name. .Ar host-group must be an existing group created using the @@ -605,7 +605,7 @@ Remove specified .Ar target from target group. .Bl -tag -width Ds -.It Fl g Ns , Ns Fl -group-name Ar taget-group +.It Fl g Ns \&, Ns Fl -group-name Ar taget-group Specifies group name. .Ar target-group must be an existing group created using the @@ -621,9 +621,9 @@ subcommand. .Xc Remove one or more view entries from a logical unit. .Bl -tag -width Ds -.It Fl a Ns , Ns Fl -all +.It Fl a Ns \&, Ns Fl -all Remove all view entries for this logical unit. -.It Fl l Ns , Ns Fl -lu-name +.It Fl l Ns \&, Ns Fl -lu-name Specify logical unit. .El .El diff --git a/usr/src/man/man1m/zdb.1m b/usr/src/man/man1m/zdb.1m index f341df4e20..c740628f4f 100644 --- a/usr/src/man/man1m/zdb.1m +++ b/usr/src/man/man1m/zdb.1m @@ -41,7 +41,7 @@ .Nm .Fl E .Op Fl A -.Ar word0 Ns : Ns Ar word1 Ns :...: Ns Ar word15 +.Ar word0 Ns \&: Ns Ar word1 Ns :...: Ns Ar word15 .Nm .Fl l .Op Fl Aqu @@ -61,7 +61,7 @@ .Op Fl A .Op Fl e Oo Fl V Oc Op Fl p Ar path ... .Op Fl U Ar cache -.Ar poolname vdev Ns : Ns Ar offset Ns : Ns Ar size Ns Op : Ns Ar flags +.Ar poolname vdev Ns \&: Ns Ar offset Ns \&: Ns Ar size Ns Op : Ns Ar flags .Nm .Fl S .Op Fl AP @@ -157,7 +157,7 @@ Display the statistics independently for each deduplication table. Dump the contents of the deduplication tables describing duplicate blocks. .It Fl DDDDD Also dump the contents of the deduplication tables describing unique blocks. -.It Fl E Ar word0 Ns : Ns Ar word1 Ns :...: Ns Ar word15 +.It Fl E Ar word0 Ns \&: Ns Ar word1 Ns :...: Ns Ar word15 Decode and display block from an embedded block pointer specified by the .Ar word arguments. @@ -218,7 +218,9 @@ must be relative to the root of This option can be combined with .Fl v for increasing verbosity. -.It Fl R Ar poolname vdev Ns : Ns Ar offset Ns : Ns Ar size Ns Op : Ns Ar flags +.It Xo +.Fl R Ar poolname vdev Ns \&: Ns Ar offset Ns \&: Ns Ar size Ns Op : Ns Ar flags +.Xc Read and display a block from the specified device. By default the block is displayed as a hex dump, but see the description of the .Sy r diff --git a/usr/src/man/man1m/zfs.1m b/usr/src/man/man1m/zfs.1m index 926d61cbf0..995b36cb38 100644 --- a/usr/src/man/man1m/zfs.1m +++ b/usr/src/man/man1m/zfs.1m @@ -26,7 +26,7 @@ .\" Copyright (c) 2014, Joyent, Inc. All rights reserved. .\" Copyright (c) 2014 by Adam Stevko. All rights reserved. .\" Copyright (c) 2014 Integros [integros.com] -.\" Copyright 2016 Nexenta Systems, Inc. +.\" Copyright 2017 Nexenta Systems, Inc. .\" .Dd September 16, 2016 .Dt ZFS 1M @@ -1715,7 +1715,7 @@ dataset. The .Sy nosuid option is an alias for -.Sy nodevices Ns , Ns Sy nosetuid . +.Sy nodevices Ns \&, Ns Sy nosetuid . These properties are reported as .Qq temporary by the @@ -1744,7 +1744,7 @@ and underscore .Pq Qq Sy _ . The expected convention is that the property name is divided into two portions such as -.Em module Ns : Ns Em property , +.Em module Ns \&: Ns Em property , but this namespace is not enforced by ZFS. User property names can be at most 256 characters, and cannot begin with a dash .Pq Qq Sy - . @@ -2171,7 +2171,7 @@ property is .Sy off .Pc . The following fields are displayed, -.Sy name Ns , Ns Sy used Ns , Ns Sy available Ns , Ns Sy referenced Ns , Ns +.Sy name Ns \&, Ns Sy used Ns \&, Ns Sy available Ns \&, Ns Sy referenced Ns \&, Ns .Sy mountpoint . .Bl -tag -width "-H" .It Fl H @@ -2209,9 +2209,9 @@ The value .Sy space to display space usage properties on file systems and volumes. This is a shortcut for specifying -.Fl o Sy name Ns , Ns Sy avail Ns , Ns Sy used Ns , Ns Sy usedsnap Ns , Ns -.Sy usedds Ns , Ns Sy usedrefreserv Ns , Ns Sy usedchild Fl t -.Sy filesystem Ns , Ns Sy volume +.Fl o Sy name Ns \&, Ns Sy avail Ns \&, Ns Sy used Ns \&, Ns Sy usedsnap Ns \&, Ns +.Sy usedds Ns \&, Ns Sy usedrefreserv Ns \&, Ns Sy usedchild Fl t +.Sy filesystem Ns \&, Ns Sy volume syntax. .El .It Fl p @@ -2333,7 +2333,7 @@ A depth of will display only the dataset and its direct children. .It Fl o Ar field A comma-separated list of columns to display. -.Sy name Ns , Ns Sy property Ns , Ns Sy value Ns , Ns Sy source +.Sy name Ns \&, Ns Sy property Ns \&, Ns Sy value Ns \&, Ns Sy source is the default value. .It Fl p Display numbers in parsable @@ -2515,7 +2515,7 @@ Print only the specified types from the following set: .Sy posixgroup , .Sy smbgroup . The default is -.Fl t Sy posixuser Ns , Ns Sy smbuser . +.Fl t Sy posixuser Ns \&, Ns Sy smbuser . The default can be changed to include group types. .El .It Xo @@ -2533,7 +2533,7 @@ filesystem or snapshot. This subcommand is identical to .Nm zfs Cm userspace , except that the default types to display are -.Fl t Sy posixgroup Ns , Ns Sy smbgroup . +.Fl t Sy posixgroup Ns \&, Ns Sy smbgroup . .It Xo .Nm .Cm mount @@ -2673,7 +2673,7 @@ snapshot to the second snapshot. For example, .Fl I Em @a Em fs@d is similar to -.Fl i Em @a Em fs@b Ns ; Fl i Em @b Em fs@c Ns ; Fl i Em @c Em fs@d . +.Fl i Em @a Em fs@b Ns \&; Fl i Em @b Em fs@c Ns \&; Fl i Em @c Em fs@d . The incremental source may be specified as with the .Fl i option. diff --git a/usr/src/man/man1m/zpool.1m b/usr/src/man/man1m/zpool.1m index 61e456ad04..3efb9930af 100644 --- a/usr/src/man/man1m/zpool.1m +++ b/usr/src/man/man1m/zpool.1m @@ -21,7 +21,7 @@ .\" .\" Copyright (c) 2007, Sun Microsystems, Inc. All Rights Reserved. .\" Copyright (c) 2013 by Delphix. All rights reserved. -.\" Copyright 2016 Nexenta Systems, Inc. +.\" Copyright 2017 Nexenta Systems, Inc. .\" .Dd Oct 2, 2016 .Dt ZPOOL 1M @@ -985,7 +985,7 @@ Do not display headers, and separate fields by a single tab instead of arbitrary space. .It Fl o Ar field A comma-separated list of columns to display. -.Sy name Ns , Ns Sy property Ns , Ns Sy value Ns , Ns Sy source +.Sy name Ns \&, Ns Sy property Ns \&, Ns Sy value Ns \&, Ns Sy source is the default value. .It Fl p Display numbers in parsable (exact) values. |
