From 25cf1a301a396c38e8adf52c15f537b80d2483f7 Mon Sep 17 00:00:00 2001 From: jl139090 Date: Sat, 8 Apr 2006 10:25:15 -0700 Subject: PSARC 2004/750 Solaris for OPL 6379529 Solaris for OPL Project --HG-- rename : usr/src/cmd/sckmd/sparc/sun4u/sckm.sh => deleted_files/usr/src/cmd/sckmd/sparc/sun4u/sckm.sh --- .../usr/src/cmd/sckmd/sparc/sun4u/sckm.sh | 52 + usr/src/Makefile | 1 + usr/src/Makefile.lint | 2 + usr/src/cmd/Makefile | 2 + usr/src/cmd/dcs/sparc/sun4u/dcs.c | 32 +- usr/src/cmd/dcs/sparc/sun4u/dcs.h | 14 +- usr/src/cmd/dcs/sparc/sun4u/rdr_messages.c | 218 +- usr/src/cmd/dcs/sparc/sun4u/rsrc_info.c | 89 +- usr/src/cmd/dcs/sparc/sun4u/rsrc_info.h | 11 +- usr/src/cmd/dcs/sparc/sun4u/svc-dcs | 25 +- usr/src/cmd/devfsadm/misc_link.c | 29 +- usr/src/cmd/fm/dicts/SUN4U.dict | 16 +- usr/src/cmd/fm/dicts/SUN4U.po | 1819 ++++---- .../cmd/fm/eversholt/files/sparc/sun4u/Makefile | 9 +- .../cmd/fm/eversholt/files/sparc/sun4u/oberon.esc | 155 + usr/src/cmd/fm/modules/Makefile | 9 +- .../cmd/fm/modules/SUNW,SPARC-Enterprise/Makefile | 29 + .../SUNW,SPARC-Enterprise/event-transport/Makefile | 36 + .../event-transport/event-transport.conf | 80 + .../event-transport/ex_dscp.c | 839 ++++ usr/src/cmd/fm/modules/common/cpumem-retire/cma.h | 12 +- .../cmd/fm/modules/common/cpumem-retire/cma_cpu.c | 28 +- .../cmd/fm/modules/common/cpumem-retire/cma_main.c | 31 +- .../cmd/fm/modules/common/cpumem-retire/cma_page.c | 30 +- .../fm/modules/common/event-transport/Makefile.etm | 49 + .../cmd/fm/modules/common/event-transport/etm.c | 1379 ++++++ .../fm/modules/common/event-transport/etm_proto.h | 76 + .../modules/common/event-transport/etm_xport_api.h | 122 + .../cmd/fm/modules/sun4/cpumem-diagnosis/cmd_cpu.c | 97 +- .../cmd/fm/modules/sun4/cpumem-diagnosis/cmd_cpu.h | 79 +- .../fm/modules/sun4/cpumem-diagnosis/cmd_cpuerr.c | 119 + .../fm/modules/sun4/cpumem-diagnosis/cmd_main.c | 104 +- .../fm/modules/sun4/cpumem-diagnosis/cmd_state.c | 34 +- .../fm/modules/sun4/cpumem-diagnosis/cmd_state.h | 30 +- .../cmd/fm/modules/sun4u/cpumem-diagnosis/Makefile | 10 +- .../fm/modules/sun4u/cpumem-diagnosis/cmd_opl.c | 565 +++ .../fm/modules/sun4u/cpumem-diagnosis/cmd_opl.h | 145 + .../files/sparc/SUNW,SPARC-Enterprise/Makefile | 30 + .../sparc/SUNW,SPARC-Enterprise/platform.topo | 585 +++ usr/src/cmd/mdb/sparc/kmdb/kmdb_kdi_isadep.c | 10 +- usr/src/cmd/mdb/sparc/kmdb/kmdb_promif_isadep.c | 27 +- usr/src/cmd/mdb/sparc/kmdb/kmdb_promif_isadep.h | 11 +- usr/src/cmd/netadm/iu.ap.sh | 10 +- usr/src/cmd/prtdscp/Makefile | 46 + usr/src/cmd/prtdscp/req.flg | 28 + usr/src/cmd/prtdscp/sparc/Makefile | 46 + usr/src/cmd/prtdscp/sparc/sun4u/Makefile | 69 + usr/src/cmd/prtdscp/sparc/sun4u/prtdscp.c | 280 ++ usr/src/cmd/sckmd/Makefile | 37 +- usr/src/cmd/sckmd/sckmd.xml | 89 + usr/src/cmd/sckmd/sparc/sun4u/Makefile | 48 +- usr/src/cmd/sckmd/sparc/sun4u/sckm.sh | 52 - usr/src/cmd/sckmd/sparc/sun4u/sckmd.c | 13 +- usr/src/cmd/sckmd/svc-sckmd | 51 + usr/src/cmd/svc/profile/Makefile | 8 +- .../svc/profile/platform_SUNW,SPARC-Enterprise.xml | 47 + .../svc/profile/platform_SUNW,Sun-Fire-15000.xml | 13 +- usr/src/lib/Makefile | 2 + usr/src/lib/efcode/Makefile | 17 +- usr/src/lib/efcode/engine/package.c | 11 +- usr/src/lib/efcode/jupiter/Makefile | 28 + usr/src/lib/efcode/jupiter/Makefile.com | 34 + usr/src/lib/efcode/jupiter/jupiter.c | 437 ++ usr/src/lib/efcode/jupiter/sparcv9/Makefile | 33 + usr/src/lib/efcode/packages/memalloc.c | 25 +- usr/src/lib/libc_psr/Makefile | 9 +- usr/src/lib/libc_psr/spec/Makefile | 9 +- usr/src/lib/libc_psr/spec/sun4u-opl/Makefile | 29 + usr/src/lib/libc_psr/spec/sun4u-opl/Makefile.links | 37 + .../lib/libc_psr/spec/sun4u-opl/c_psr-sparc.spec | 66 + .../lib/libc_psr/spec/sun4u-opl/c_psr-sparcv9.spec | 67 + usr/src/lib/libc_psr/spec/sun4u-opl/sparc/Makefile | 51 + .../lib/libc_psr/spec/sun4u-opl/sparcv9/Makefile | 51 + usr/src/lib/libc_psr/spec/sun4u-opl/versions-sparc | 31 + .../lib/libc_psr/spec/sun4u-opl/versions-sparcv9 | 30 + usr/src/lib/libc_psr/sun4u-opl/Makefile | 61 + usr/src/lib/libc_psr/sun4u-opl/Makefile.com | 72 + usr/src/lib/libc_psr/sun4u-opl/common/memcpy.s | 716 ++++ usr/src/lib/libc_psr/sun4u-opl/sparc/Makefile | 70 + usr/src/lib/libc_psr/sun4u-opl/sparcv9/Makefile | 73 + usr/src/lib/libdscp/Makefile | 62 + usr/src/lib/libdscp/Makefile.com | 68 + usr/src/lib/libdscp/libdscp.c | 542 +++ usr/src/lib/libdscp/libdscp.h | 72 + usr/src/lib/libdscp/llib-ldscp | 32 + usr/src/lib/libdscp/sparc/Makefile | 35 + usr/src/lib/libdscp/spec/Makefile | 61 + usr/src/lib/libdscp/spec/Makefile.targ | 35 + usr/src/lib/libdscp/spec/libdscp.spec | 56 + usr/src/lib/libdscp/spec/sparc/Makefile | 38 + usr/src/lib/libdscp/spec/versions | 31 + usr/src/lib/libdscp/svc/Makefile | 56 + usr/src/lib/libdscp/svc/dscp.ppp.options | 112 + usr/src/lib/libdscp/svc/dscp.xml | 121 + usr/src/lib/libdscp/svc/svc-dscp | 111 + usr/src/lib/libprtdiag/common/cpu.c | 13 +- usr/src/lib/libprtdiag/inc/libprtdiag.h | 9 +- usr/src/lib/libprtdiag_psr/sparc/Makefile | 9 +- usr/src/lib/libprtdiag_psr/sparc/opl/Makefile | 74 + usr/src/lib/libprtdiag_psr/sparc/opl/common/opl.c | 850 ++++ usr/src/pkgdefs/Makefile | 2 + usr/src/pkgdefs/SUNWcakr.u/prototype_com | 36 +- usr/src/pkgdefs/SUNWcar.u/prototype_com | 7 + usr/src/pkgdefs/SUNWcpcu/prototype_sparc | 9 +- usr/src/pkgdefs/SUNWcryr/prototype_sparc | 12 +- usr/src/pkgdefs/SUNWcsr/Makefile | 8 +- usr/src/pkgdefs/SUNWcsr/pkginfo.tmpl | 2 +- usr/src/pkgdefs/SUNWcsr/prototype_com | 3 +- usr/src/pkgdefs/SUNWcsr/prototype_sparc | 8 +- usr/src/pkgdefs/SUNWdscpr.u/Makefile | 38 + usr/src/pkgdefs/SUNWdscpr.u/depend | 53 + usr/src/pkgdefs/SUNWdscpr.u/pkginfo.tmpl | 56 + usr/src/pkgdefs/SUNWdscpr.u/prototype_com | 66 + usr/src/pkgdefs/SUNWdscpr.u/prototype_sparc | 50 + usr/src/pkgdefs/SUNWdscpu.u/Makefile | 36 + usr/src/pkgdefs/SUNWdscpu.u/depend | 54 + usr/src/pkgdefs/SUNWdscpu.u/pkginfo.tmpl | 55 + usr/src/pkgdefs/SUNWdscpu.u/prototype_com | 55 + usr/src/pkgdefs/SUNWdscpu.u/prototype_sparc | 50 + usr/src/pkgdefs/SUNWefcl/prototype_sparc | 2 + usr/src/pkgdefs/SUNWfmd/prototype_sparc | 8 + usr/src/pkgdefs/SUNWhea/prototype_com | 1 + usr/src/pkgdefs/SUNWhea/prototype_sparc | 6 + usr/src/pkgdefs/SUNWkvm.u/prototype_com | 19 +- usr/src/pkgdefs/SUNWonmtst.u/prototype_sparc | 8 +- usr/src/pkgdefs/SUNWsckmr/Makefile | 10 +- usr/src/pkgdefs/SUNWsckmr/depend | 52 + usr/src/pkgdefs/SUNWsckmr/pkginfo.tmpl | 8 +- usr/src/pkgdefs/SUNWsckmr/preremove | 19 +- usr/src/pkgdefs/SUNWsckmr/prototype_com | 34 +- usr/src/pkgdefs/SUNWsckmu.u/depend | 8 +- usr/src/pkgdefs/SUNWsckmu.u/pkginfo.tmpl | 4 +- usr/src/pkgdefs/SUNWsckmu.u/prototype_com | 15 +- usr/src/pkgdefs/common_files/i.ttydefs | 61 + usr/src/pkgdefs/etc/exception_list_i386 | 1 + usr/src/psm/promif/ieee1275/sun4u/Makefile.files | 12 +- usr/src/psm/promif/ieee1275/sun4u/prom_opl.c | 137 + usr/src/psm/stand/boot/sparc/common/sun4dep.c | 21 +- usr/src/uts/common/io/hotplug/pciehpc/pciehpc.c | 62 +- usr/src/uts/common/os/chip.c | 9 +- usr/src/uts/common/os/cpu.c | 7 +- usr/src/uts/common/sys/Makefile | 3 +- usr/src/uts/common/sys/ddidmareq.h | 12 +- usr/src/uts/common/sys/fm/io/opl_mc_fm.h | 69 + usr/src/uts/common/sys/fm/io/sun4_fire.h | 41 +- usr/src/uts/sfmmu/ml/sfmmu_asm.s | 129 +- usr/src/uts/sfmmu/vm/hat_sfmmu.c | 19 +- usr/src/uts/sfmmu/vm/hat_sfmmu.h | 18 +- usr/src/uts/sparc/fpu/fpu_simulator.c | 554 ++- usr/src/uts/sparc/os/driver_aliases | 7 + usr/src/uts/sparc/os/name_to_major | 7 + usr/src/uts/sparc/sys/Makefile | 8 +- usr/src/uts/sparc/sys/cpu.h | 11 +- usr/src/uts/sparc/sys/fm/cpu/SPARC64-VI.h | 118 + usr/src/uts/sparc/sys/fpu/fpu_simulator.h | 35 +- usr/src/uts/sun4/io/px/px_debug.c | 9 +- usr/src/uts/sun4/io/px/px_dma.c | 15 +- usr/src/uts/sun4/io/px/px_dma.h | 4 +- usr/src/uts/sun4/io/px/px_fdvma.c | 2 +- usr/src/uts/sun4/io/px/px_ib.c | 26 +- usr/src/uts/sun4/io/px/px_ioapi.h | 17 +- usr/src/uts/sun4/io/px/px_lib.h | 4 +- usr/src/uts/sun4/io/px/px_mmu.h | 5 +- usr/src/uts/sun4/io/px/px_space.c | 76 +- usr/src/uts/sun4/io/px/px_space.h | 65 +- usr/src/uts/sun4/io/px/px_tools.c | 12 +- usr/src/uts/sun4/io/px/px_var.h | 2 +- usr/src/uts/sun4/io/trapstat.c | 45 +- usr/src/uts/sun4/ml/interrupt.s | 8 +- usr/src/uts/sun4/os/startup.c | 12 +- usr/src/uts/sun4/sys/platform_module.h | 9 +- usr/src/uts/sun4u/Makefile.files | 5 + usr/src/uts/sun4u/Makefile.sun4u.shared | 6 +- usr/src/uts/sun4u/Makefile.workarounds | 14 +- usr/src/uts/sun4u/cpu/common_asm.s | 55 +- usr/src/uts/sun4u/cpu/opl_kdi.c | 156 + usr/src/uts/sun4u/cpu/opl_olympus.c | 2237 ++++++++++ usr/src/uts/sun4u/cpu/opl_olympus_asm.s | 1991 +++++++++ usr/src/uts/sun4u/cpu/opl_olympus_copy.s | 3716 ++++++++++++++++ usr/src/uts/sun4u/io/opl_cfg.c | 2559 +++++++++++ usr/src/uts/sun4u/io/px/oberon_regs.h | 183 + usr/src/uts/sun4u/io/px/px_err.c | 340 +- usr/src/uts/sun4u/io/px/px_err.h | 38 +- usr/src/uts/sun4u/io/px/px_err_impl.h | 19 +- usr/src/uts/sun4u/io/px/px_hlib.c | 900 +++- usr/src/uts/sun4u/io/px/px_lib4u.c | 354 +- usr/src/uts/sun4u/io/px/px_lib4u.h | 61 +- usr/src/uts/sun4u/io/todopl.c | 321 ++ usr/src/uts/sun4u/ml/mach_locore.s | 12 +- usr/src/uts/sun4u/ml/mach_offsets.in | 8 +- usr/src/uts/sun4u/ml/trap_table.s | 100 +- usr/src/uts/sun4u/ngdr/io/dr.c | 87 +- usr/src/uts/sun4u/ngdr/io/dr_cpu.c | 69 +- usr/src/uts/sun4u/ngdr/io/dr_io.c | 10 +- usr/src/uts/sun4u/ngdr/io/dr_mem.c | 156 +- usr/src/uts/sun4u/ngdr/io/dr_util.c | 209 +- usr/src/uts/sun4u/ngdr/sys/dr.h | 60 +- usr/src/uts/sun4u/ngdr/sys/dr_util.h | 36 +- usr/src/uts/sun4u/opl/Makefile | 147 + usr/src/uts/sun4u/opl/Makefile.files | 56 + usr/src/uts/sun4u/opl/Makefile.opl | 150 + usr/src/uts/sun4u/opl/Makefile.rules | 147 + usr/src/uts/sun4u/opl/Makefile.targ | 116 + usr/src/uts/sun4u/opl/dm2s/Makefile | 105 + usr/src/uts/sun4u/opl/dr/Makefile | 92 + usr/src/uts/sun4u/opl/drmach/Makefile | 116 + usr/src/uts/sun4u/opl/genassym/Makefile | 97 + usr/src/uts/sun4u/opl/io/dm2s.c | 1291 ++++++ usr/src/uts/sun4u/opl/io/dm2s.conf | 28 + usr/src/uts/sun4u/opl/io/dr.conf | 27 + usr/src/uts/sun4u/opl/io/dr_mem.c | 2760 ++++++++++++ usr/src/uts/sun4u/opl/io/drmach.c | 3929 +++++++++++++++++ usr/src/uts/sun4u/opl/io/mc-opl.c | 2442 +++++++++++ usr/src/uts/sun4u/opl/io/mc-opl.conf | 26 + usr/src/uts/sun4u/opl/io/oplkmdrv.c | 1107 +++++ usr/src/uts/sun4u/opl/io/oplkmdrv.conf | 28 + usr/src/uts/sun4u/opl/io/oplmsu/oplmsu.c | 2471 +++++++++++ usr/src/uts/sun4u/opl/io/oplmsu/oplmsu_cmn_func.c | 1845 ++++++++ usr/src/uts/sun4u/opl/io/oplmsu/oplmsu_ioctl_lrp.c | 780 ++++ usr/src/uts/sun4u/opl/io/oplmsu/oplmsu_ioctl_uwp.c | 471 +++ usr/src/uts/sun4u/opl/io/oplpanel/oplpanel.c | 414 ++ usr/src/uts/sun4u/opl/io/oplpanel/oplpanel.conf | 29 + usr/src/uts/sun4u/opl/io/options.conf | 42 + usr/src/uts/sun4u/opl/io/pcicmu/pcicmu.c | 2202 ++++++++++ usr/src/uts/sun4u/opl/io/pcicmu/pcmu_cb.c | 288 ++ usr/src/uts/sun4u/opl/io/pcicmu/pcmu_counters.c | 253 ++ usr/src/uts/sun4u/opl/io/pcicmu/pcmu_ecc.c | 469 +++ usr/src/uts/sun4u/opl/io/pcicmu/pcmu_ib.c | 747 ++++ usr/src/uts/sun4u/opl/io/pcicmu/pcmu_intr.c | 340 ++ usr/src/uts/sun4u/opl/io/pcicmu/pcmu_pbm.c | 290 ++ usr/src/uts/sun4u/opl/io/pcicmu/pcmu_util.c | 707 ++++ usr/src/uts/sun4u/opl/io/scfd/scf_os_interface.c | 143 + usr/src/uts/sun4u/opl/io/scfd/scfconf.c | 1124 +++++ usr/src/uts/sun4u/opl/io/scfd/scfd.conf | 52 + usr/src/uts/sun4u/opl/io/scfd/scfdebug.c | 2028 +++++++++ usr/src/uts/sun4u/opl/io/scfd/scfdscp.c | 4450 ++++++++++++++++++++ usr/src/uts/sun4u/opl/io/scfd/scfhandler.c | 3458 +++++++++++++++ usr/src/uts/sun4u/opl/io/scfd/scfinit.c | 301 ++ usr/src/uts/sun4u/opl/io/scfd/scfiomp.c | 2286 ++++++++++ usr/src/uts/sun4u/opl/io/scfd/scfkstat.c | 219 + usr/src/uts/sun4u/opl/io/scfd/scfops.c | 3470 +++++++++++++++ usr/src/uts/sun4u/opl/io/scfd/scfostoescf.c | 307 ++ usr/src/uts/sun4u/opl/io/scfd/scfparam.c | 147 + usr/src/uts/sun4u/opl/io/scfd/scfreg.c | 1977 +++++++++ usr/src/uts/sun4u/opl/io/scfd/scfsnap.c | 766 ++++ usr/src/uts/sun4u/opl/io/scfd/scftimer.c | 603 +++ usr/src/uts/sun4u/opl/io/scfd/scftrace.c | 152 + usr/src/uts/sun4u/opl/mc-opl/Makefile | 98 + usr/src/uts/sun4u/opl/ml/drmach.il.cpp | 198 + usr/src/uts/sun4u/opl/ml/drmach_asm.s | 507 +++ usr/src/uts/sun4u/opl/ml/drmach_offsets.in | 60 + usr/src/uts/sun4u/opl/olympus_c/Makefile | 116 + usr/src/uts/sun4u/opl/oplkmdrv/Makefile | 100 + usr/src/uts/sun4u/opl/oplmsu/Makefile | 88 + usr/src/uts/sun4u/opl/oplpanel/Makefile | 87 + usr/src/uts/sun4u/opl/options/Makefile | 86 + usr/src/uts/sun4u/opl/os/opl.c | 855 ++++ usr/src/uts/sun4u/opl/pcicmu/Makefile | 93 + usr/src/uts/sun4u/opl/platmod/Makefile | 97 + usr/src/uts/sun4u/opl/scfd/Makefile | 88 + usr/src/uts/sun4u/opl/sys/Makefile | 124 + usr/src/uts/sun4u/opl/sys/dm2s.h | 110 + usr/src/uts/sun4u/opl/sys/drmach.h | 355 ++ usr/src/uts/sun4u/opl/sys/fiomp.h | 240 ++ usr/src/uts/sun4u/opl/sys/mc-opl.h | 342 ++ usr/src/uts/sun4u/opl/sys/opl_hwdesc.h | 511 +++ usr/src/uts/sun4u/opl/sys/oplkm.h | 103 + usr/src/uts/sun4u/opl/sys/oplkm_msg.h | 91 + usr/src/uts/sun4u/opl/sys/oplmsu/oplmsu.h | 358 ++ usr/src/uts/sun4u/opl/sys/oplmsu/oplmsu_proto.h | 166 + usr/src/uts/sun4u/opl/sys/pcicmu/pcicmu.h | 450 ++ usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_cb.h | 81 + usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_counters.h | 78 + usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_ecc.h | 75 + usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_err.h | 135 + usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_ib.h | 173 + usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_pbm.h | 99 + usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_types.h | 54 + usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_util.h | 123 + usr/src/uts/sun4u/opl/sys/scfd/iomp_drv.h | 134 + usr/src/uts/sun4u/opl/sys/scfd/opcio.h | 326 ++ usr/src/uts/sun4u/opl/sys/scfd/scfdebug.h | 308 ++ usr/src/uts/sun4u/opl/sys/scfd/scfdscp.h | 468 ++ usr/src/uts/sun4u/opl/sys/scfd/scfdscpif.h | 104 + usr/src/uts/sun4u/opl/sys/scfd/scfio32.h | 68 + usr/src/uts/sun4u/opl/sys/scfd/scfkstat.h | 102 + usr/src/uts/sun4u/opl/sys/scfd/scfostoescf.h | 54 + usr/src/uts/sun4u/opl/sys/scfd/scfparam.h | 158 + usr/src/uts/sun4u/opl/sys/scfd/scfreg.h | 581 +++ usr/src/uts/sun4u/opl/sys/scfd/scfsnap.h | 111 + usr/src/uts/sun4u/opl/sys/scfd/scfstate.h | 197 + usr/src/uts/sun4u/opl/sys/scfd/scfsys.h | 862 ++++ usr/src/uts/sun4u/opl/sys/scfd/scftimer.h | 123 + usr/src/uts/sun4u/opl/sys/scfd/scftrace.h | 215 + usr/src/uts/sun4u/opl/unix/Makefile | 191 + usr/src/uts/sun4u/opl_cfg/Makefile | 103 + usr/src/uts/sun4u/opl_pcbe/Makefile | 84 + usr/src/uts/sun4u/os/cmp.c | 32 +- usr/src/uts/sun4u/os/cpr_impl.c | 18 +- usr/src/uts/sun4u/os/fillsysinfo.c | 108 +- usr/src/uts/sun4u/os/mach_startup.c | 207 +- usr/src/uts/sun4u/pcbe/opl_pcbe.c | 619 +++ usr/src/uts/sun4u/serengeti/io/sbdp_mem.c | 4 +- usr/src/uts/sun4u/serengeti/sys/sbdp_mem.h | 3 +- usr/src/uts/sun4u/starcat/io/drmach.c | 72 +- usr/src/uts/sun4u/starcat/io/fcgp2.c | 14 +- usr/src/uts/sun4u/starcat/os/starcat.c | 9 +- usr/src/uts/sun4u/starfire/io/drmach.c | 68 +- usr/src/uts/sun4u/sys/Makefile | 3 + usr/src/uts/sun4u/sys/cheetahregs.h | 66 +- usr/src/uts/sun4u/sys/cpu_impl.h | 110 + usr/src/uts/sun4u/sys/cpu_module.h | 14 +- usr/src/uts/sun4u/sys/machasi.h | 9 +- usr/src/uts/sun4u/sys/machclock.h | 9 +- usr/src/uts/sun4u/sys/machparam.h | 7 +- usr/src/uts/sun4u/sys/machthread.h | 15 +- usr/src/uts/sun4u/sys/opl.h | 80 + usr/src/uts/sun4u/sys/opl_cfg.h | 306 ++ usr/src/uts/sun4u/sys/opl_module.h | 159 + usr/src/uts/sun4u/sys/opl_olympus_regs.h | 311 ++ usr/src/uts/sun4u/sys/prom_plat.h | 16 +- usr/src/uts/sun4u/sys/pte.h | 39 +- usr/src/uts/sun4u/sys/sbd_ioctl.h | 28 +- usr/src/uts/sun4u/todopl/Makefile | 88 + usr/src/uts/sun4u/vm/mach_sfmmu.c | 11 +- usr/src/uts/sun4u/vm/mach_sfmmu.h | 302 +- usr/src/uts/sun4u/vm/mach_sfmmu_asm.s | 46 +- usr/src/uts/sun4v/Makefile.workarounds | 1 + usr/src/uts/sun4v/io/px/px_lib4v.c | 14 +- 329 files changed, 84233 insertions(+), 2751 deletions(-) create mode 100644 deleted_files/usr/src/cmd/sckmd/sparc/sun4u/sckm.sh create mode 100644 usr/src/cmd/fm/eversholt/files/sparc/sun4u/oberon.esc create mode 100644 usr/src/cmd/fm/modules/SUNW,SPARC-Enterprise/Makefile create mode 100644 usr/src/cmd/fm/modules/SUNW,SPARC-Enterprise/event-transport/Makefile create mode 100644 usr/src/cmd/fm/modules/SUNW,SPARC-Enterprise/event-transport/event-transport.conf create mode 100644 usr/src/cmd/fm/modules/SUNW,SPARC-Enterprise/event-transport/ex_dscp.c create mode 100644 usr/src/cmd/fm/modules/common/event-transport/Makefile.etm create mode 100644 usr/src/cmd/fm/modules/common/event-transport/etm.c create mode 100644 usr/src/cmd/fm/modules/common/event-transport/etm_proto.h create mode 100644 usr/src/cmd/fm/modules/common/event-transport/etm_xport_api.h create mode 100644 usr/src/cmd/fm/modules/sun4u/cpumem-diagnosis/cmd_opl.c create mode 100644 usr/src/cmd/fm/modules/sun4u/cpumem-diagnosis/cmd_opl.h create mode 100644 usr/src/cmd/fm/topo/files/sparc/SUNW,SPARC-Enterprise/Makefile create mode 100644 usr/src/cmd/fm/topo/files/sparc/SUNW,SPARC-Enterprise/platform.topo create mode 100644 usr/src/cmd/prtdscp/Makefile create mode 100644 usr/src/cmd/prtdscp/req.flg create mode 100644 usr/src/cmd/prtdscp/sparc/Makefile create mode 100644 usr/src/cmd/prtdscp/sparc/sun4u/Makefile create mode 100644 usr/src/cmd/prtdscp/sparc/sun4u/prtdscp.c create mode 100644 usr/src/cmd/sckmd/sckmd.xml delete mode 100644 usr/src/cmd/sckmd/sparc/sun4u/sckm.sh create mode 100644 usr/src/cmd/sckmd/svc-sckmd create mode 100644 usr/src/cmd/svc/profile/platform_SUNW,SPARC-Enterprise.xml create mode 100644 usr/src/lib/efcode/jupiter/Makefile create mode 100644 usr/src/lib/efcode/jupiter/Makefile.com create mode 100644 usr/src/lib/efcode/jupiter/jupiter.c create mode 100644 usr/src/lib/efcode/jupiter/sparcv9/Makefile create mode 100644 usr/src/lib/libc_psr/spec/sun4u-opl/Makefile create mode 100644 usr/src/lib/libc_psr/spec/sun4u-opl/Makefile.links create mode 100644 usr/src/lib/libc_psr/spec/sun4u-opl/c_psr-sparc.spec create mode 100644 usr/src/lib/libc_psr/spec/sun4u-opl/c_psr-sparcv9.spec create mode 100644 usr/src/lib/libc_psr/spec/sun4u-opl/sparc/Makefile create mode 100644 usr/src/lib/libc_psr/spec/sun4u-opl/sparcv9/Makefile create mode 100644 usr/src/lib/libc_psr/spec/sun4u-opl/versions-sparc create mode 100644 usr/src/lib/libc_psr/spec/sun4u-opl/versions-sparcv9 create mode 100644 usr/src/lib/libc_psr/sun4u-opl/Makefile create mode 100644 usr/src/lib/libc_psr/sun4u-opl/Makefile.com create mode 100644 usr/src/lib/libc_psr/sun4u-opl/common/memcpy.s create mode 100644 usr/src/lib/libc_psr/sun4u-opl/sparc/Makefile create mode 100644 usr/src/lib/libc_psr/sun4u-opl/sparcv9/Makefile create mode 100644 usr/src/lib/libdscp/Makefile create mode 100644 usr/src/lib/libdscp/Makefile.com create mode 100644 usr/src/lib/libdscp/libdscp.c create mode 100644 usr/src/lib/libdscp/libdscp.h create mode 100644 usr/src/lib/libdscp/llib-ldscp create mode 100644 usr/src/lib/libdscp/sparc/Makefile create mode 100644 usr/src/lib/libdscp/spec/Makefile create mode 100644 usr/src/lib/libdscp/spec/Makefile.targ create mode 100644 usr/src/lib/libdscp/spec/libdscp.spec create mode 100644 usr/src/lib/libdscp/spec/sparc/Makefile create mode 100644 usr/src/lib/libdscp/spec/versions create mode 100644 usr/src/lib/libdscp/svc/Makefile create mode 100644 usr/src/lib/libdscp/svc/dscp.ppp.options create mode 100644 usr/src/lib/libdscp/svc/dscp.xml create mode 100644 usr/src/lib/libdscp/svc/svc-dscp create mode 100644 usr/src/lib/libprtdiag_psr/sparc/opl/Makefile create mode 100644 usr/src/lib/libprtdiag_psr/sparc/opl/common/opl.c create mode 100644 usr/src/pkgdefs/SUNWdscpr.u/Makefile create mode 100644 usr/src/pkgdefs/SUNWdscpr.u/depend create mode 100644 usr/src/pkgdefs/SUNWdscpr.u/pkginfo.tmpl create mode 100644 usr/src/pkgdefs/SUNWdscpr.u/prototype_com create mode 100644 usr/src/pkgdefs/SUNWdscpr.u/prototype_sparc create mode 100644 usr/src/pkgdefs/SUNWdscpu.u/Makefile create mode 100644 usr/src/pkgdefs/SUNWdscpu.u/depend create mode 100644 usr/src/pkgdefs/SUNWdscpu.u/pkginfo.tmpl create mode 100644 usr/src/pkgdefs/SUNWdscpu.u/prototype_com create mode 100644 usr/src/pkgdefs/SUNWdscpu.u/prototype_sparc create mode 100644 usr/src/pkgdefs/SUNWsckmr/depend create mode 100644 usr/src/pkgdefs/common_files/i.ttydefs create mode 100644 usr/src/psm/promif/ieee1275/sun4u/prom_opl.c create mode 100644 usr/src/uts/common/sys/fm/io/opl_mc_fm.h create mode 100644 usr/src/uts/sparc/sys/fm/cpu/SPARC64-VI.h create mode 100644 usr/src/uts/sun4u/cpu/opl_kdi.c create mode 100644 usr/src/uts/sun4u/cpu/opl_olympus.c create mode 100644 usr/src/uts/sun4u/cpu/opl_olympus_asm.s create mode 100644 usr/src/uts/sun4u/cpu/opl_olympus_copy.s create mode 100644 usr/src/uts/sun4u/io/opl_cfg.c create mode 100644 usr/src/uts/sun4u/io/px/oberon_regs.h create mode 100644 usr/src/uts/sun4u/io/todopl.c create mode 100644 usr/src/uts/sun4u/opl/Makefile create mode 100644 usr/src/uts/sun4u/opl/Makefile.files create mode 100644 usr/src/uts/sun4u/opl/Makefile.opl create mode 100644 usr/src/uts/sun4u/opl/Makefile.rules create mode 100644 usr/src/uts/sun4u/opl/Makefile.targ create mode 100644 usr/src/uts/sun4u/opl/dm2s/Makefile create mode 100644 usr/src/uts/sun4u/opl/dr/Makefile create mode 100644 usr/src/uts/sun4u/opl/drmach/Makefile create mode 100644 usr/src/uts/sun4u/opl/genassym/Makefile create mode 100644 usr/src/uts/sun4u/opl/io/dm2s.c create mode 100644 usr/src/uts/sun4u/opl/io/dm2s.conf create mode 100644 usr/src/uts/sun4u/opl/io/dr.conf create mode 100644 usr/src/uts/sun4u/opl/io/dr_mem.c create mode 100644 usr/src/uts/sun4u/opl/io/drmach.c create mode 100644 usr/src/uts/sun4u/opl/io/mc-opl.c create mode 100644 usr/src/uts/sun4u/opl/io/mc-opl.conf create mode 100644 usr/src/uts/sun4u/opl/io/oplkmdrv.c create mode 100644 usr/src/uts/sun4u/opl/io/oplkmdrv.conf create mode 100644 usr/src/uts/sun4u/opl/io/oplmsu/oplmsu.c create mode 100644 usr/src/uts/sun4u/opl/io/oplmsu/oplmsu_cmn_func.c create mode 100644 usr/src/uts/sun4u/opl/io/oplmsu/oplmsu_ioctl_lrp.c create mode 100644 usr/src/uts/sun4u/opl/io/oplmsu/oplmsu_ioctl_uwp.c create mode 100644 usr/src/uts/sun4u/opl/io/oplpanel/oplpanel.c create mode 100644 usr/src/uts/sun4u/opl/io/oplpanel/oplpanel.conf create mode 100644 usr/src/uts/sun4u/opl/io/options.conf create mode 100644 usr/src/uts/sun4u/opl/io/pcicmu/pcicmu.c create mode 100644 usr/src/uts/sun4u/opl/io/pcicmu/pcmu_cb.c create mode 100644 usr/src/uts/sun4u/opl/io/pcicmu/pcmu_counters.c create mode 100644 usr/src/uts/sun4u/opl/io/pcicmu/pcmu_ecc.c create mode 100644 usr/src/uts/sun4u/opl/io/pcicmu/pcmu_ib.c create mode 100644 usr/src/uts/sun4u/opl/io/pcicmu/pcmu_intr.c create mode 100644 usr/src/uts/sun4u/opl/io/pcicmu/pcmu_pbm.c create mode 100644 usr/src/uts/sun4u/opl/io/pcicmu/pcmu_util.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scf_os_interface.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scfconf.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scfd.conf create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scfdebug.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scfdscp.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scfhandler.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scfinit.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scfiomp.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scfkstat.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scfops.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scfostoescf.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scfparam.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scfreg.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scfsnap.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scftimer.c create mode 100644 usr/src/uts/sun4u/opl/io/scfd/scftrace.c create mode 100644 usr/src/uts/sun4u/opl/mc-opl/Makefile create mode 100644 usr/src/uts/sun4u/opl/ml/drmach.il.cpp create mode 100644 usr/src/uts/sun4u/opl/ml/drmach_asm.s create mode 100644 usr/src/uts/sun4u/opl/ml/drmach_offsets.in create mode 100644 usr/src/uts/sun4u/opl/olympus_c/Makefile create mode 100644 usr/src/uts/sun4u/opl/oplkmdrv/Makefile create mode 100644 usr/src/uts/sun4u/opl/oplmsu/Makefile create mode 100644 usr/src/uts/sun4u/opl/oplpanel/Makefile create mode 100644 usr/src/uts/sun4u/opl/options/Makefile create mode 100644 usr/src/uts/sun4u/opl/os/opl.c create mode 100644 usr/src/uts/sun4u/opl/pcicmu/Makefile create mode 100644 usr/src/uts/sun4u/opl/platmod/Makefile create mode 100644 usr/src/uts/sun4u/opl/scfd/Makefile create mode 100644 usr/src/uts/sun4u/opl/sys/Makefile create mode 100644 usr/src/uts/sun4u/opl/sys/dm2s.h create mode 100644 usr/src/uts/sun4u/opl/sys/drmach.h create mode 100644 usr/src/uts/sun4u/opl/sys/fiomp.h create mode 100644 usr/src/uts/sun4u/opl/sys/mc-opl.h create mode 100644 usr/src/uts/sun4u/opl/sys/opl_hwdesc.h create mode 100644 usr/src/uts/sun4u/opl/sys/oplkm.h create mode 100644 usr/src/uts/sun4u/opl/sys/oplkm_msg.h create mode 100644 usr/src/uts/sun4u/opl/sys/oplmsu/oplmsu.h create mode 100644 usr/src/uts/sun4u/opl/sys/oplmsu/oplmsu_proto.h create mode 100644 usr/src/uts/sun4u/opl/sys/pcicmu/pcicmu.h create mode 100644 usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_cb.h create mode 100644 usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_counters.h create mode 100644 usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_ecc.h create mode 100644 usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_err.h create mode 100644 usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_ib.h create mode 100644 usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_pbm.h create mode 100644 usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_types.h create mode 100644 usr/src/uts/sun4u/opl/sys/pcicmu/pcmu_util.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/iomp_drv.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/opcio.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/scfdebug.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/scfdscp.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/scfdscpif.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/scfio32.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/scfkstat.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/scfostoescf.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/scfparam.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/scfreg.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/scfsnap.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/scfstate.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/scfsys.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/scftimer.h create mode 100644 usr/src/uts/sun4u/opl/sys/scfd/scftrace.h create mode 100644 usr/src/uts/sun4u/opl/unix/Makefile create mode 100644 usr/src/uts/sun4u/opl_cfg/Makefile create mode 100644 usr/src/uts/sun4u/opl_pcbe/Makefile create mode 100644 usr/src/uts/sun4u/pcbe/opl_pcbe.c create mode 100644 usr/src/uts/sun4u/sys/cpu_impl.h create mode 100644 usr/src/uts/sun4u/sys/opl.h create mode 100644 usr/src/uts/sun4u/sys/opl_cfg.h create mode 100644 usr/src/uts/sun4u/sys/opl_module.h create mode 100644 usr/src/uts/sun4u/sys/opl_olympus_regs.h create mode 100644 usr/src/uts/sun4u/todopl/Makefile diff --git a/deleted_files/usr/src/cmd/sckmd/sparc/sun4u/sckm.sh b/deleted_files/usr/src/cmd/sckmd/sparc/sun4u/sckm.sh new file mode 100644 index 0000000000..f9fe17758c --- /dev/null +++ b/deleted_files/usr/src/cmd/sckmd/sparc/sun4u/sckm.sh @@ -0,0 +1,52 @@ +#! /sbin/sh +# +# CDDL HEADER START +# +# The contents of this file are subject to the terms of the +# Common Development and Distribution License, Version 1.0 only +# (the "License"). You may not use this file except in compliance +# with the License. +# +# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE +# or http://www.opensolaris.org/os/licensing. +# See the License for the specific language governing permissions +# and limitations under the License. +# +# When distributing Covered Code, include this CDDL HEADER in each +# file and include the License file at usr/src/OPENSOLARIS.LICENSE. +# If applicable, add the following below this CDDL HEADER, with the +# fields enclosed by brackets "[]" replaced with your own identifying +# information: Portions Copyright [yyyy] [name of copyright owner] +# +# CDDL HEADER END +# +# +#pragma ident "%Z%%M% %I% %E% SMI" +# +# Copyright (c) 2000 by Sun Microsystems, Inc. +# All rights reserved. +# +# Startup script for Sun Fire 15000 Key Management Daemon +# + +case "$1" in +'start') + platform=${_INIT_UTS_PLATFORM:-`/sbin/uname -i`} + starcat="SUNW,Sun-Fire-15000" + if [ ${platform} = "${starcat}" ]; then + if [ -x /usr/platform/${platform}/lib/sckmd ]; then + /usr/platform/${platform}/lib/sckmd + fi + fi + ;; + +'stop') + /usr/bin/pkill -9 -x -u 0 sckmd + ;; + +*) + echo "Usage: $0 { start | stop }" + exit 1 + ;; +esac +exit 0 diff --git a/usr/src/Makefile b/usr/src/Makefile index 9bb3ce8da2..1feef8e6ce 100644 --- a/usr/src/Makefile +++ b/usr/src/Makefile @@ -275,6 +275,7 @@ EXPORT_SRC: @cd $(CLOSED)/uts/sun4u/lw2plus; pwd; $(MAKE) EXPORT_SRC @cd uts/sun4u/lw8; pwd; $(MAKE) EXPORT_SRC @cd uts/sun4u/mpxu; pwd; $(MAKE) EXPORT_SRC + @cd uts/sun4u/opl; pwd; $(MAKE) EXPORT_SRC @cd uts/sun4u/serengeti; pwd; $(MAKE) EXPORT_SRC @cd uts/sun4u/starcat; pwd; $(MAKE) EXPORT_SRC @cd uts/sun4u/taco; pwd; $(MAKE) EXPORT_SRC diff --git a/usr/src/Makefile.lint b/usr/src/Makefile.lint index db6904d8a2..a3c57b9c20 100644 --- a/usr/src/Makefile.lint +++ b/usr/src/Makefile.lint @@ -407,10 +407,12 @@ sparc_SUBDIRS= \ cmd/datadm \ cmd/dcs \ cmd/fruadm \ + cmd/prtdscp \ cmd/prtfru \ cmd/sckmd \ cmd/wrsmconf \ cmd/wrsmstat \ + lib/libdscp \ lib/libwrsmconf \ lib/wrsm \ lib/libpcp \ diff --git a/usr/src/cmd/Makefile b/usr/src/cmd/Makefile index 580a2f51ff..6c39c9b938 100644 --- a/usr/src/cmd/Makefile +++ b/usr/src/cmd/Makefile @@ -450,6 +450,7 @@ sparc_SUBDIRS= \ cvcd \ dcs \ fruadm \ + prtdscp \ prtfru \ scadm \ sckmd \ @@ -687,6 +688,7 @@ $(CLOSED_BUILD)MSGSUBDIRS += \ sparc_MSGSUBDIRS= \ fruadm \ + prtdscp \ prtfru \ stmsboot \ wrsmconf \ diff --git a/usr/src/cmd/dcs/sparc/sun4u/dcs.c b/usr/src/cmd/dcs/sparc/sun4u/dcs.c index c926ad5f82..2748217737 100644 --- a/usr/src/cmd/dcs/sparc/sun4u/dcs.c +++ b/usr/src/cmd/dcs/sparc/sun4u/dcs.c @@ -145,6 +145,7 @@ int (*dcs_cmd[])(rdr_msg_hdr_t *, cfga_params_t *) = { * strictly decreasing. */ dcs_ver_t ver_supp[] = { + { 1, 1 }, { 1, 0 } }; @@ -160,6 +161,8 @@ int standalone = 0; /* control standalone mode */ boolean_t inetd = B_FALSE; /* control daemon mode */ ulong_t max_sessions = DCS_MAX_SESSIONS; /* control maximum active sessions */ int dcsfd = STDIN_FILENO; /* fd for the DCS reserved port */ +int use_libdscp = 0; /* control use of libdscp */ +sa_family_t use_family = AF_INET6; /* control use of AF_INET/AF_INET6 */ /* * Array of acceptable -a, -e and -u arguments. @@ -287,6 +290,11 @@ main(int argc, char **argv) break; + case 'l': + use_libdscp = 1; + use_family = AF_INET; + break; + default: if (optopt == 'a' || optopt == 'e' || optopt == 'u') dcs_log_bad_alg(optopt, optarg); @@ -476,7 +484,7 @@ init_server(struct pollfd *pfd, uint8_t ah_auth_alg, uint8_t esp_encr_alg, if (inetd == B_FALSE || standalone) { /* in standalone mode, init fd for reserved port */ - if ((dcsfd = rdr_open(AF_INET6)) == -1) { + if ((dcsfd = rdr_open(use_family)) == -1) { DCS_DBG(DBG_ALL, "rdr_open failed"); return (-1); } @@ -531,16 +539,24 @@ init_server(struct pollfd *pfd, uint8_t ah_auth_alg, uint8_t esp_encr_alg, req_port = se->s_port; } - /* initialize our local address */ - sin6 = (struct sockaddr_in6 *)&ss; - (void) memset(sin6, 0, sizeof (*sin6)); - sin6->sin6_family = AF_INET6; - sin6->sin6_port = htons(req_port); - sin6->sin6_addr = in6addr_any; + (void) memset(&ss, 0, sizeof (ss)); + if (use_family == AF_INET) { + /* initialize our local address */ + sin = (struct sockaddr_in *)&ss; + sin->sin_family = AF_INET; + sin->sin_port = htons(req_port); + sin->sin_addr.s_addr = htonl(INADDR_ANY); + } else { + /* initialize our local address */ + sin6 = (struct sockaddr_in6 *)&ss; + sin6->sin6_family = AF_INET6; + sin6->sin6_port = htons(req_port); + sin6->sin6_addr = in6addr_any; + } num_sock_opts = sizeof (sock_opts) / sizeof (*sock_opts); - init_status = rdr_init(pfd->fd, (struct sockaddr *)sin6, + init_status = rdr_init(pfd->fd, (struct sockaddr *)&ss, sock_opts, num_sock_opts, DCS_BACKLOG); if (init_status != RDR_OK) { diff --git a/usr/src/cmd/dcs/sparc/sun4u/dcs.h b/usr/src/cmd/dcs/sparc/sun4u/dcs.h index b8a328c68b..aa5d8dcb27 100644 --- a/usr/src/cmd/dcs/sparc/sun4u/dcs.h +++ b/usr/src/cmd/dcs/sparc/sun4u/dcs.h @@ -2,9 +2,8 @@ * CDDL HEADER START * * The contents of this file are subject to the terms of the - * Common Development and Distribution License, Version 1.0 only - * (the "License"). You may not use this file except in compliance - * with the License. + * Common Development and Distribution License (the "License"). + * You may not use this file except in compliance with the License. * * You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE * or http://www.opensolaris.org/os/licensing. @@ -20,7 +19,7 @@ * CDDL HEADER END */ /* - * Copyright 2005 Sun Microsystems, Inc. All rights reserved. + * Copyright 2006 Sun Microsystems, Inc. All rights reserved. * Use is subject to license terms. */ @@ -121,8 +120,9 @@ typedef struct dcs_alg { * -a control the IPsec AH algorithm ("none", "md5", or "sha1") * -e control the IPsec ESP encr algorithm ("none", "des", or "3des") * -u control the IPsec ESP auth algorithm ("none", "md5", or "sha1") + * -l control the use of libdscp for endpoint authentication. */ -#define OPT_STR "d:Ss:a:e:u:" +#define OPT_STR "d:Ss:a:e:u:l" #else /* DCS_DEBUG */ @@ -133,8 +133,9 @@ typedef struct dcs_alg { * -a control the IPsec AH algorithm ("none", "md5", or "sha1") * -e control the IPsec ESP encr algorithm ("none", "des", or "3des") * -u control the IPsec ESP auth algorithm ("none", "md5", or "sha1") + * -l control the use of libdscp for endpoint authentication. */ -#define OPT_STR "s:a:e:u:" +#define OPT_STR "s:a:e:u:l" #endif /* DCS_DEBUG */ @@ -273,6 +274,7 @@ typedef enum { extern ulong_t dcs_debug; extern int standalone; extern ulong_t max_sessions; +extern int use_libdscp; /* diff --git a/usr/src/cmd/dcs/sparc/sun4u/rdr_messages.c b/usr/src/cmd/dcs/sparc/sun4u/rdr_messages.c index f672887a17..51b836a57b 100644 --- a/usr/src/cmd/dcs/sparc/sun4u/rdr_messages.c +++ b/usr/src/cmd/dcs/sparc/sun4u/rdr_messages.c @@ -2,9 +2,8 @@ * CDDL HEADER START * * The contents of this file are subject to the terms of the - * Common Development and Distribution License, Version 1.0 only - * (the "License"). You may not use this file except in compliance - * with the License. + * Common Development and Distribution License (the "License"). + * You may not use this file except in compliance with the License. * * You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE * or http://www.opensolaris.org/os/licensing. @@ -20,7 +19,7 @@ * CDDL HEADER END */ /* - * Copyright 2005 Sun Microsystems, Inc. All rights reserved. + * Copyright 2006 Sun Microsystems, Inc. All rights reserved. * Use is subject to license terms. */ @@ -56,10 +55,14 @@ #include #include #include +#include #include +#include #include +#include #include +#include "dcs.h" #include "remote_cfg.h" #include "rdr_param_types.h" #include "rdr_messages.h" @@ -85,7 +88,6 @@ typedef struct { int function_pad_sz; } rdr_variable_message_info_t; - /* * A table of maximum sizes for each message type. Message size is * validated when the message header is first received. This prevents @@ -131,6 +133,30 @@ struct { static const int RDR_ALIGN_64_BIT = 8; /* 8 bytes */ +/* + * Interfaces for dynamic use of libdscp. + */ + +#define LIBDSCP_PATH "/usr/platform/%s/lib/libdscp.so.1" + +#define LIBDSCP_BIND "dscpBind" +#define LIBDSCP_SECURE "dscpSecure" +#define LIBDSCP_AUTH "dscpAuth" + +typedef enum { + LIBDSCP_UNKNOWN = 0, + LIBDSCP_AVAILABLE, + LIBDSCP_UNAVAILABLE +} dscp_status_t; + +typedef struct { + dscp_status_t status; + int (*bind)(int, int, int); + int (*secure)(int, int); + int (*auth)(int, struct sockaddr *, int); +} libdscp_t; + +static libdscp_t libdscp; /* * Static Function Declarations @@ -143,6 +169,10 @@ static int rdr_setopt(int fd, int name, int level); static int rdr_bind(int fd, struct sockaddr *addr); +static int rdr_secure(int fd, struct sockaddr *addr); + +static int rdr_auth(struct sockaddr *addr, int len); + static int rdr_snd(int fd, rdr_msg_hdr_t *hdr, char *data, int data_sz, int timeout); static int rdr_snd_raw(int fd, char *msg, int data_sz, int timeout); @@ -151,7 +181,6 @@ static int rdr_rcv(int fd, rdr_msg_hdr_t *hdr, char **data, int timeout); static int rdr_rcv_raw(int fd, char *msg, int data_size, int timeout); - /* * Data Validation Routines */ @@ -270,7 +299,7 @@ static int pack_rsrc_info_request(rsrc_info_params_t *params, char **buf, static int unpack_rsrc_info_request(rsrc_info_params_t *params, const char *buf); static int pack_rsrc_info_reply(rsrc_info_params_t *params, char **buf, - int *buf_size); + int *buf_size, int encoding); static int unpack_rsrc_info_reply(rsrc_info_params_t *params, const char *buf); /* @@ -312,6 +341,11 @@ static int cleanup_errstring(char **errstring); static void cleanup_variable_ap_id_info( rdr_variable_message_info_t *var_msg_info); +/* + * Functions for loading libdscp. + */ +static int load_libdscp(libdscp_t *libdscp); + /* * Public Functions */ @@ -360,6 +394,11 @@ rdr_init(int fd, struct sockaddr *addr, int *opts, int num_opts, int blog) num_opts = 0; } + /* turn on security features */ + if (rdr_secure(fd, addr) != RDR_OK) { + return (RDR_NET_ERR); + } + /* bind the address, if is not already bound */ if (rdr_bind(fd, addr) != RDR_OK) { return (RDR_NET_ERR); @@ -457,11 +496,18 @@ rdr_connect_srv(int fd) struct sockaddr_storage faddr; + /* accept the connection */ faddr_len = sizeof (faddr); if ((newfd = accept(fd, (struct sockaddr *)&faddr, &faddr_len)) == -1) { return (RDR_BAD_FD); } + /* if the peer doesn't authenticate properly, reject */ + if (rdr_auth((struct sockaddr *)&faddr, faddr_len) != RDR_OK) { + (void) close(newfd); + return (RDR_BAD_FD); + } + return (newfd); } @@ -486,7 +532,7 @@ rdr_reject(int fd) } /* then close it */ - close(fd); + (void) close(fd); return (RDR_OK); } @@ -500,7 +546,7 @@ rdr_reject(int fd) int rdr_close(int fd) { - close(fd); + (void) close(fd); return (RDR_OK); } @@ -718,8 +764,16 @@ rdr_snd_msg(int fd, rdr_msg_hdr_t *hdr, cfga_params_t *param, int timeout) err = pack_rsrc_info_request(rparam, &pack_buf, &pack_buf_sz); } else { - err = pack_rsrc_info_reply(rparam, &pack_buf, - &pack_buf_sz); + if ((hdr->major_version == 1) && + (hdr->minor_version == 0)) { + err = pack_rsrc_info_reply(rparam, + &pack_buf, &pack_buf_sz, + NV_ENCODE_NATIVE); + } else { + err = pack_rsrc_info_reply(rparam, + &pack_buf, &pack_buf_sz, + NV_ENCODE_XDR); + } } break; } @@ -1290,6 +1344,69 @@ rdr_bind(int fd, struct sockaddr *addr) } +/* + * rdr_secure: + * + * Activate security features for a socket. + * + * Some platforms have libdscp, which provides additional + * security features. An attempt is made to load libdscp + * and use these features. + * + * Nothing is done if libdscp is not available. + */ +static int +rdr_secure(int fd, struct sockaddr *addr) +{ + struct sockaddr_in *sin; + int port; + int error; + + if (use_libdscp == 0) { + return (RDR_OK); + } + + if (load_libdscp(&libdscp) != 1) { + return (RDR_ERROR); + } + + /* LINTED E_BAD_PTR_CAST_ALIGN */ + sin = (struct sockaddr_in *)addr; + port = ntohs(sin->sin_port); + error = libdscp.bind(0, fd, port); + + if ((error != DSCP_OK) && (error != DSCP_ERROR_ALREADY)) { + return (RDR_ERROR); + } + + if (libdscp.secure(0, fd) != DSCP_OK) { + return (RDR_ERROR); + } + return (RDR_OK); +} + +/* + * rdr_auth: + * + * Authenticate if a connection is really from the service + * processor. This is dependent upon functionality from + * libdscp, so an attempt to load and use libdscp is made. + * + * Without libdscp, this function does nothing. + */ +static int +rdr_auth(struct sockaddr *addr, int len) +{ + if (use_libdscp != 0) { + if ((load_libdscp(&libdscp) == 0) || + (libdscp.auth(0, addr, len) != DSCP_OK)) { + return (RDR_ERROR); + } + } + + return (RDR_OK); +} + /* * rdr_snd: * @@ -3916,7 +4033,8 @@ unpack_rsrc_info_request(rsrc_info_params_t *params, const char *buf) * Handle packing a resource info reply message. */ static int -pack_rsrc_info_reply(rsrc_info_params_t *params, char **buf, int *buf_size) +pack_rsrc_info_reply(rsrc_info_params_t *params, char **buf, int *buf_size, + int encoding) { char *bufptr; rdr_rsrc_info_reply_t rsrc_info_data; @@ -3932,7 +4050,8 @@ pack_rsrc_info_reply(rsrc_info_params_t *params, char **buf, int *buf_size) /* * Pack snapshot handle data. */ - pack_status = ri_pack(params->hdl, &rsrc_info_bufp, &rsrc_info_size); + pack_status = ri_pack(params->hdl, &rsrc_info_bufp, &rsrc_info_size, + encoding); if (pack_status != 0) { return (RDR_ERROR); } @@ -4363,3 +4482,76 @@ cleanup_variable_ap_id_info(rdr_variable_message_info_t *var_msg_info) } } } + +/* + * load_libdscp: + * + * Try to dynamically link with libdscp. + * + * Returns: 0 if libdscp not available, + * 1 if libdscp is available. + */ +static int +load_libdscp(libdscp_t *libdscp) +{ + int len; + void *lib; + static char platform[100]; + static char pathname[MAXPATHLEN]; + + /* + * Only try to load libdscp once. Use the saved + * status in the libdscp interface to know the + * results of previous attempts. + */ + if (libdscp->status == LIBDSCP_AVAILABLE) { + return (1); + } + if (libdscp->status == LIBDSCP_UNAVAILABLE) { + return (0); + } + + /* + * Construct a platform specific pathname for libdscp. + */ + len = sysinfo(SI_PLATFORM, platform, sizeof (platform)); + if ((len < 0) || (len > sizeof (platform))) { + return (0); + } + len = snprintf(pathname, MAXPATHLEN, LIBDSCP_PATH, platform); + if (len >= MAXPATHLEN) { + libdscp->status = LIBDSCP_UNAVAILABLE; + return (0); + } + + /* + * Try dynamically loading libdscp. + */ + if ((lib = dlopen(pathname, RTLD_LAZY)) == NULL) { + libdscp->status = LIBDSCP_UNAVAILABLE; + return (0); + } + + /* + * Try to resolve all the symbols. + */ + libdscp->bind = (int (*)(int, int, int))dlsym(lib, LIBDSCP_BIND); + libdscp->secure = (int (*)(int, int))dlsym(lib, LIBDSCP_SECURE); + libdscp->auth = (int (*)(int, struct sockaddr *, int))dlsym(lib, + LIBDSCP_AUTH); + + if ((libdscp->bind == NULL) || + (libdscp->secure == NULL) || + (libdscp->auth == NULL)) { + (void) dlclose(lib); + libdscp->status = LIBDSCP_UNAVAILABLE; + return (0); + } + + /* + * Success. + * Update the status to indicate libdscp is available. + */ + libdscp->status = LIBDSCP_AVAILABLE; + return (1); +} diff --git a/usr/src/cmd/dcs/sparc/sun4u/rsrc_info.c b/usr/src/cmd/dcs/sparc/sun4u/rsrc_info.c index 3f5239f26d..2587613f89 100644 --- a/usr/src/cmd/dcs/sparc/sun4u/rsrc_info.c +++ b/usr/src/cmd/dcs/sparc/sun4u/rsrc_info.c @@ -2,9 +2,8 @@ * CDDL HEADER START * * The contents of this file are subject to the terms of the - * Common Development and Distribution License, Version 1.0 only - * (the "License"). You may not use this file except in compliance - * with the License. + * Common Development and Distribution License (the "License"). + * You may not use this file except in compliance with the License. * * You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE * or http://www.opensolaris.org/os/licensing. @@ -20,8 +19,8 @@ * CDDL HEADER END */ /* - * Copyright (c) 2000-2001 by Sun Microsystems, Inc. - * All rights reserved. + * Copyright 2006 Sun Microsystems, Inc. All rights reserved. + * Use is subject to license terms. */ #pragma ident "%Z%%M% %I% %E% SMI" @@ -36,19 +35,19 @@ #include "rsrc_info.h" #include "rsrc_info_impl.h" -static int ap_list_pack(ri_ap_t *, char **, size_t *); +static int ap_list_pack(ri_ap_t *, char **, size_t *, int); static int ap_list_unpack(char *, size_t, ri_ap_t **); -static int ap_pack(ri_ap_t *, char **, size_t *); +static int ap_pack(ri_ap_t *, char **, size_t *, int); static int ap_unpack(char *, size_t, ri_ap_t *); -static int dev_list_pack(ri_dev_t *, char **, size_t *); +static int dev_list_pack(ri_dev_t *, char **, size_t *, int); static int dev_list_unpack(char *, size_t, ri_dev_t **); -static int dev_pack(ri_dev_t *, char **, size_t *); +static int dev_pack(ri_dev_t *, char **, size_t *, int); static int dev_unpack(char *, size_t, ri_dev_t *); -static int client_list_pack(ri_client_t *, char **, size_t *); +static int client_list_pack(ri_client_t *, char **, size_t *, int); static int client_list_unpack(char *, size_t, ri_client_t **); -static int client_pack(ri_client_t *, char **, size_t *); +static int client_pack(ri_client_t *, char **, size_t *, int); static int client_unpack(char *, size_t, ri_client_t *); -static int pack_add_byte_array(nvlist_t *, char *, nvlist_t *); +static int pack_add_byte_array(nvlist_t *, char *, nvlist_t *, int); static int lookup_unpack_byte_array(nvlist_t *, char *, nvlist_t **); static void ri_ap_free(ri_ap_t *); @@ -132,7 +131,7 @@ ri_client_free(ri_client_t *client) * Pack everything contained in the handle up inside out. */ int -ri_pack(ri_hdl_t *hdl, caddr_t *bufp, size_t *sizep) +ri_pack(ri_hdl_t *hdl, caddr_t *bufp, size_t *sizep, int encoding) { nvlist_t *nvl = NULL; char *buf = NULL; @@ -162,27 +161,29 @@ ri_pack(ri_hdl_t *hdl, caddr_t *bufp, size_t *sizep) goto fail; } - if (ap_list_pack(hdl->aps, &buf, &size) != 0 || + if (ap_list_pack(hdl->aps, &buf, &size, encoding) != 0 || nvlist_add_byte_array(nvl, RI_HDL_APS, (uchar_t *)buf, size) != 0) { goto fail; } s_free(buf); - if (client_list_pack(hdl->cpu_cap_clients, &buf, &size) != 0 || + if (client_list_pack(hdl->cpu_cap_clients, &buf, &size, + encoding) != 0 || nvlist_add_byte_array(nvl, RI_HDL_CPU_CAPS, (uchar_t *)buf, size) != 0) { goto fail; } s_free(buf); - if (client_list_pack(hdl->mem_cap_clients, &buf, &size) != 0 || + if (client_list_pack(hdl->mem_cap_clients, &buf, &size, + encoding) != 0 || nvlist_add_byte_array(nvl, RI_HDL_MEM_CAPS, (uchar_t *)buf, size) != 0) { goto fail; } s_free(buf); - if (nvlist_pack(nvl, &buf, &size, NV_ENCODE_NATIVE, 0) != 0) { + if (nvlist_pack(nvl, &buf, &size, encoding, 0) != 0) { dprintf((stderr, "nvlist_pack fail\n")); goto fail; } @@ -205,7 +206,7 @@ fail: * Pack a list of attachment point handles. */ static int -ap_list_pack(ri_ap_t *aplist, char **bufp, size_t *sizep) +ap_list_pack(ri_ap_t *aplist, char **bufp, size_t *sizep, int encoding) { nvlist_t *nvl = NULL; char *buf = NULL; @@ -223,7 +224,7 @@ ap_list_pack(ri_ap_t *aplist, char **bufp, size_t *sizep) while (aplist != NULL) { s_free(buf); - if (ap_pack(aplist, &buf, &size) != 0) + if (ap_pack(aplist, &buf, &size, encoding) != 0) goto fail; if (nvlist_add_byte_array(nvl, RI_AP_T, (uchar_t *)buf, @@ -236,7 +237,7 @@ ap_list_pack(ri_ap_t *aplist, char **bufp, size_t *sizep) } s_free(buf); - if (nvlist_pack(nvl, &buf, &size, NV_ENCODE_NATIVE, 0) != 0) { + if (nvlist_pack(nvl, &buf, &size, encoding, 0) != 0) { dprintf((stderr, "nvlist_pack fail\n")); goto fail; } @@ -259,7 +260,7 @@ fail: * Pack a list of ri_dev_t's. */ static int -dev_list_pack(ri_dev_t *devlist, char **bufp, size_t *sizep) +dev_list_pack(ri_dev_t *devlist, char **bufp, size_t *sizep, int encoding) { nvlist_t *nvl = NULL; char *buf = NULL; @@ -277,7 +278,7 @@ dev_list_pack(ri_dev_t *devlist, char **bufp, size_t *sizep) while (devlist != NULL) { s_free(buf); - if (dev_pack(devlist, &buf, &size) != 0) + if (dev_pack(devlist, &buf, &size, encoding) != 0) goto fail; if (nvlist_add_byte_array(nvl, RI_DEV_T, (uchar_t *)buf, @@ -290,7 +291,7 @@ dev_list_pack(ri_dev_t *devlist, char **bufp, size_t *sizep) } s_free(buf); - if (nvlist_pack(nvl, &buf, &size, NV_ENCODE_NATIVE, 0) != 0) { + if (nvlist_pack(nvl, &buf, &size, encoding, 0) != 0) { dprintf((stderr, "nvlist_pack fail\n")); goto fail; } @@ -313,7 +314,8 @@ fail: * Pack a list of ri_client_t's. */ static int -client_list_pack(ri_client_t *client_list, char **bufp, size_t *sizep) +client_list_pack(ri_client_t *client_list, char **bufp, size_t *sizep, + int encoding) { nvlist_t *nvl = NULL; char *buf = NULL; @@ -331,7 +333,7 @@ client_list_pack(ri_client_t *client_list, char **bufp, size_t *sizep) while (client_list != NULL) { s_free(buf); - if (client_pack(client_list, &buf, &size) != 0) + if (client_pack(client_list, &buf, &size, encoding) != 0) goto fail; if (nvlist_add_byte_array(nvl, RI_CLIENT_T, (uchar_t *)buf, @@ -344,7 +346,7 @@ client_list_pack(ri_client_t *client_list, char **bufp, size_t *sizep) } s_free(buf); - if (nvlist_pack(nvl, &buf, &size, NV_ENCODE_NATIVE, 0) != 0) { + if (nvlist_pack(nvl, &buf, &size, encoding, 0) != 0) { dprintf((stderr, "nvlist_pack fail\n")); goto fail; } @@ -364,7 +366,7 @@ fail: } static int -ap_pack(ri_ap_t *ap, char **bufp, size_t *sizep) +ap_pack(ri_ap_t *ap, char **bufp, size_t *sizep, int encoding) { nvlist_t *nvl = NULL; char *buf = NULL; @@ -375,10 +377,11 @@ ap_pack(ri_ap_t *ap, char **bufp, size_t *sizep) return (-1); } - if (pack_add_byte_array(ap->conf_props, RI_AP_PROPS, nvl) != 0) + if (pack_add_byte_array(ap->conf_props, RI_AP_PROPS, nvl, + encoding) != 0) goto fail; - if (dev_list_pack(ap->cpus, &buf, &size) != 0) + if (dev_list_pack(ap->cpus, &buf, &size, encoding) != 0) goto fail; if (nvlist_add_byte_array(nvl, RI_AP_CPUS, (uchar_t *)buf, @@ -388,7 +391,7 @@ ap_pack(ri_ap_t *ap, char **bufp, size_t *sizep) } s_free(buf); - if (dev_list_pack(ap->mems, &buf, &size) != 0) + if (dev_list_pack(ap->mems, &buf, &size, encoding) != 0) goto fail; if (nvlist_add_byte_array(nvl, RI_AP_MEMS, (uchar_t *)buf, @@ -398,7 +401,7 @@ ap_pack(ri_ap_t *ap, char **bufp, size_t *sizep) } s_free(buf); - if (dev_list_pack(ap->ios, &buf, &size) != 0) + if (dev_list_pack(ap->ios, &buf, &size, encoding) != 0) goto fail; if (nvlist_add_byte_array(nvl, RI_AP_IOS, (uchar_t *)buf, @@ -408,7 +411,7 @@ ap_pack(ri_ap_t *ap, char **bufp, size_t *sizep) } s_free(buf); - if (nvlist_pack(nvl, &buf, &size, NV_ENCODE_NATIVE, 0) != 0) { + if (nvlist_pack(nvl, &buf, &size, encoding, 0) != 0) { dprintf((stderr, "nvlist_pack fail\n")); goto fail; } @@ -428,7 +431,7 @@ fail: } static int -dev_pack(ri_dev_t *dev, char **bufp, size_t *sizep) +dev_pack(ri_dev_t *dev, char **bufp, size_t *sizep, int encoding) { nvlist_t *nvl = NULL; char *buf = NULL; @@ -439,10 +442,11 @@ dev_pack(ri_dev_t *dev, char **bufp, size_t *sizep) return (-1); } - if (pack_add_byte_array(dev->conf_props, RI_DEV_PROPS, nvl) != 0) + if (pack_add_byte_array(dev->conf_props, RI_DEV_PROPS, nvl, + encoding) != 0) goto fail; - if (client_list_pack(dev->rcm_clients, &buf, &size) != 0) + if (client_list_pack(dev->rcm_clients, &buf, &size, encoding) != 0) goto fail; if (nvlist_add_byte_array(nvl, RI_DEV_CLIENTS, (uchar_t *)buf, @@ -453,7 +457,7 @@ dev_pack(ri_dev_t *dev, char **bufp, size_t *sizep) } s_free(buf); - if (nvlist_pack(nvl, &buf, &size, NV_ENCODE_NATIVE, 0) != 0) { + if (nvlist_pack(nvl, &buf, &size, encoding, 0) != 0) { dprintf((stderr, "nvlist_pack fail\n")); goto fail; } @@ -473,7 +477,7 @@ fail: } static int -client_pack(ri_client_t *client, char **bufp, size_t *sizep) +client_pack(ri_client_t *client, char **bufp, size_t *sizep, int encoding) { nvlist_t *nvl = NULL; char *buf = NULL; @@ -485,7 +489,7 @@ client_pack(ri_client_t *client, char **bufp, size_t *sizep) } if (pack_add_byte_array(client->usg_props, RI_CLIENT_USAGE_PROPS, - nvl) != 0) { + nvl, encoding) != 0) { goto fail; } @@ -494,11 +498,11 @@ client_pack(ri_client_t *client, char **bufp, size_t *sizep) * in the call to ri_init. */ if (client->v_props != NULL && pack_add_byte_array(client->v_props, - RI_CLIENT_VERB_PROPS, nvl) != 0) { + RI_CLIENT_VERB_PROPS, nvl, encoding) != 0) { goto fail; } - if (nvlist_pack(nvl, &buf, &size, NV_ENCODE_NATIVE, 0) != 0) { + if (nvlist_pack(nvl, &buf, &size, encoding, 0) != 0) { dprintf((stderr, "nvlist_pack fail\n")); goto fail; } @@ -521,12 +525,13 @@ fail: * Pack nvlist_t and add as byte array to another nvlist_t. */ static int -pack_add_byte_array(nvlist_t *nvl_packme, char *name, nvlist_t *nvl) +pack_add_byte_array(nvlist_t *nvl_packme, char *name, nvlist_t *nvl, + int encoding) { char *buf = NULL; size_t size = 0; - if (nvlist_pack(nvl_packme, &buf, &size, NV_ENCODE_NATIVE, 0) != 0) { + if (nvlist_pack(nvl_packme, &buf, &size, encoding, 0) != 0) { dprintf((stderr, "nvlist_pack fail (%s)\n", name)); s_free(buf); return (-1); diff --git a/usr/src/cmd/dcs/sparc/sun4u/rsrc_info.h b/usr/src/cmd/dcs/sparc/sun4u/rsrc_info.h index dfedebfe62..d663e9dcbf 100644 --- a/usr/src/cmd/dcs/sparc/sun4u/rsrc_info.h +++ b/usr/src/cmd/dcs/sparc/sun4u/rsrc_info.h @@ -2,9 +2,8 @@ * CDDL HEADER START * * The contents of this file are subject to the terms of the - * Common Development and Distribution License, Version 1.0 only - * (the "License"). You may not use this file except in compliance - * with the License. + * Common Development and Distribution License (the "License"). + * You may not use this file except in compliance with the License. * * You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE * or http://www.opensolaris.org/os/licensing. @@ -20,8 +19,8 @@ * CDDL HEADER END */ /* - * Copyright (c) 2000 by Sun Microsystems, Inc. - * All rights reserved. + * Copyright 2006 Sun Microsystems, Inc. All rights reserved. + * Use is subject to license terms. */ #ifndef _RSRC_INFO_H @@ -147,7 +146,7 @@ int ri_init(uint_t, int, char **, int, ri_hdl_t **); #else int ri_init(int, char **, int, ri_hdl_t **); #endif /* SMSLIB_TARGET */ -int ri_pack(ri_hdl_t *, caddr_t *, size_t *); +int ri_pack(ri_hdl_t *, caddr_t *, size_t *, int encoding); int ri_unpack(caddr_t, size_t, ri_hdl_t **); void ri_fini(ri_hdl_t *); ri_ap_t *ri_ap_next(ri_hdl_t *, ri_ap_t *); diff --git a/usr/src/cmd/dcs/sparc/sun4u/svc-dcs b/usr/src/cmd/dcs/sparc/sun4u/svc-dcs index 5245357f96..52e0897ef7 100644 --- a/usr/src/cmd/dcs/sparc/sun4u/svc-dcs +++ b/usr/src/cmd/dcs/sparc/sun4u/svc-dcs @@ -1,14 +1,13 @@ #!/sbin/sh # -# Copyright 2005 Sun Microsystems, Inc. All rights reserved. +# Copyright 2006 Sun Microsystems, Inc. All rights reserved. # Use is subject to license terms. # # CDDL HEADER START # # The contents of this file are subject to the terms of the -# Common Development and Distribution License, Version 1.0 only -# (the "License"). You may not use this file except in compliance -# with the License. +# Common Development and Distribution License (the "License"). +# You may not use this file except in compliance with the License. # # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE # or http://www.opensolaris.org/os/licensing. @@ -48,17 +47,27 @@ getproparg() { DCS=/usr/lib/dcs platform=`/sbin/uname -i` -starfire="SUNW,Ultra-Enterprise-10000" -starcat="SUNW,Sun-Fire-15000" +e10k="SUNW,Ultra-Enterprise-10000" +sf15k="SUNW,Sun-Fire-15000" +opl="SUNW,SPARC-Enterprise" +fjopl="FJSV,SPARC-Enterprise" +tmpopl="SUNW,OPL-Enterprise" args="" -if [ $platform = "$starcat" ]; then +if [ $platform = "$sf15k" ]; then args="$args `getproparg -a dcs/ah_auth`" args="$args `getproparg -e dcs/esp_encr`" args="$args `getproparg -u dcs/esp_auth`" +elif [ $platform = "$opl" -o \ + $platform = "$fjopl" -o \ + $platform = "$tmpopl" ]; then + args="-l" fi -if [ $platform = "$starfire" -o $platform = "$starcat" ]; then +if [ $platform = "$e10k" -o $platform = "$sf15k" -o \ + $platform = "$opl" -o \ + $platform = "$fjopl" -o \ + $platform = "$tmpopl" ]; then $DCS $args # Fail if can't execute exit # Use dcs's exit status else diff --git a/usr/src/cmd/devfsadm/misc_link.c b/usr/src/cmd/devfsadm/misc_link.c index d446392618..a8f0ef5d71 100644 --- a/usr/src/cmd/devfsadm/misc_link.c +++ b/usr/src/cmd/devfsadm/misc_link.c @@ -2,9 +2,8 @@ * CDDL HEADER START * * The contents of this file are subject to the terms of the - * Common Development and Distribution License, Version 1.0 only - * (the "License"). You may not use this file except in compliance - * with the License. + * Common Development and Distribution License (the "License"). + * You may not use this file except in compliance with the License. * * You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE * or http://www.opensolaris.org/os/licensing. @@ -20,7 +19,7 @@ * CDDL HEADER END */ /* - * Copyright 2005 Sun Microsystems, Inc. All rights reserved. + * Copyright 2006 Sun Microsystems, Inc. All rights reserved. * Use is subject to license terms. */ @@ -58,6 +57,7 @@ static int zcons_create(di_minor_t minor, di_node_t node); static int cpuid(di_minor_t minor, di_node_t node); static int glvc(di_minor_t minor, di_node_t node); static int ses_callback(di_minor_t minor, di_node_t node); +static int kmdrv_create(di_minor_t minor, di_node_t node); static devfsadm_create_t misc_cbt[] = { { "pseudo", "ddi_pseudo", "(^pts$)|(^sad$)", @@ -146,7 +146,10 @@ static devfsadm_create_t misc_cbt[] = { TYPE_EXACT | DRV_EXACT, ILEVEL_0, gpio }, { "pseudo", "ddi_pseudo", "sckmdrv", - TYPE_EXACT | DRV_RE, ILEVEL_0, minor_name, + TYPE_EXACT | DRV_RE, ILEVEL_0, kmdrv_create, + }, + { "pseudo", "ddi_pseudo", "oplkmdrv", + TYPE_EXACT | DRV_RE, ILEVEL_0, kmdrv_create, }, { "av", "^ddi_av:(isoch|async)$", NULL, TYPE_RE, ILEVEL_0, av_create, @@ -169,6 +172,9 @@ static devfsadm_create_t misc_cbt[] = { { "pseudo", "ddi_pseudo", "glvc", TYPE_EXACT | DRV_EXACT, ILEVEL_0, glvc, }, + { "pseudo", "ddi_pseudo", "dm2s", + TYPE_EXACT | DRV_EXACT, ILEVEL_0, minor_name, + }, }; DEVFSADM_CREATE_INIT_V0(misc_cbt); @@ -658,3 +664,16 @@ glvc(di_minor_t minor, di_node_t node) } return (DEVFSADM_CONTINUE); } + +/* + * Handles links of the form: + * type=ddi_pseudo;name=sckmdrv kmdrv\M0 + * type=ddi_pseudo;name=oplkmdrv kmdrv\M0 + */ +static int +kmdrv_create(di_minor_t minor, di_node_t node) +{ + + (void) devfsadm_mklink("kmdrv", node, minor, 0); + return (DEVFSADM_CONTINUE); +} diff --git a/usr/src/cmd/fm/dicts/SUN4U.dict b/usr/src/cmd/fm/dicts/SUN4U.dict index 236373e354..91b46e4b29 100644 --- a/usr/src/cmd/fm/dicts/SUN4U.dict +++ b/usr/src/cmd/fm/dicts/SUN4U.dict @@ -1,13 +1,12 @@ # -# Copyright 2005 Sun Microsystems, Inc. All rights reserved. +# Copyright 2006 Sun Microsystems, Inc. All rights reserved. # Use is subject to license terms. # # CDDL HEADER START # # The contents of this file are subject to the terms of the -# Common Development and Distribution License, Version 1.0 only -# (the "License"). You may not use this file except in compliance -# with the License. +# Common Development and Distribution License (the "License"). +# You may not use this file except in compliance with the License. # # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE # or http://www.opensolaris.org/os/licensing. @@ -23,8 +22,11 @@ # CDDL HEADER END # #ident "%Z%%M% %I% %E% SMI" +# +# DO NOT EDIT -- this file is generated by the Event Registry. +# -FMDICT: name=SUN4U version=1 maxkey=7 +FMDICT: name=SUN4U version=1 maxkey=7 dictid=0x3455 fault.memory.page=1 fault.memory.dimm=2 @@ -255,3 +257,7 @@ fault.asic.dx.dp=226 fault.asic.sdi.dp=227 fault.asic.cp.dp=228 fault.asic.rp.dp=229 +fault.io.oberon=230 +fault.cpu.SPARC64-VI.chip=231 +fault.cpu.SPARC64-VI.core=232 +fault.cpu.SPARC64-VI.strand=233 diff --git a/usr/src/cmd/fm/dicts/SUN4U.po b/usr/src/cmd/fm/dicts/SUN4U.po index b5f62c1f1e..95ec5cd8a9 100644 --- a/usr/src/cmd/fm/dicts/SUN4U.po +++ b/usr/src/cmd/fm/dicts/SUN4U.po @@ -1,13 +1,12 @@ # -# Copyright 2005 Sun Microsystems, Inc. All rights reserved. +# Copyright 2006 Sun Microsystems, Inc. All rights reserved. # Use is subject to license terms. # # CDDL HEADER START # # The contents of this file are subject to the terms of the -# Common Development and Distribution License, Version 1.0 only -# (the "License"). You may not use this file except in compliance -# with the License. +# Common Development and Distribution License (the "License"). +# You may not use this file except in compliance with the License. # # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE # or http://www.opensolaris.org/os/licensing. @@ -23,7 +22,9 @@ # CDDL HEADER END # #ident "%Z%%M% %I% %E% SMI" - +# +# DO NOT EDIT -- this file is generated by the Event Registry. +# # # code: SUN4U-8000-1A # keys: fault.memory.page @@ -47,7 +48,7 @@ msgstr "No repair action is recommended at this time." msgid "SUN4U-8000-2S.type" msgstr "Fault" msgid "SUN4U-8000-2S.severity" -msgstr "Minor" +msgstr "Major" msgid "SUN4U-8000-2S.description" msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-2S.response" @@ -55,7 +56,7 @@ msgstr "Pages of memory associated with this memory module are being removed fro msgid "SUN4U-8000-2S.impact" msgstr "Total system memory capacity will be reduced as pages are retired." msgid "SUN4U-8000-2S.action" -msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u to identify the module." +msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u to identify the module." # # code: SUN4U-8000-35 # keys: fault.memory.bank @@ -63,7 +64,7 @@ msgstr "Schedule a repair procedure to replace the affected memory module. Use msgid "SUN4U-8000-35.type" msgstr "Fault" msgid "SUN4U-8000-35.severity" -msgstr "Minor" +msgstr "Critical" msgid "SUN4U-8000-35.description" msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-35.response" @@ -71,7 +72,7 @@ msgstr "Pages of memory associated with this memory module are being removed fro msgid "SUN4U-8000-35.impact" msgstr "Total system memory capacity will be reduced as pages are retired." msgid "SUN4U-8000-35.action" -msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u to identify the module." +msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u to identify the module." # # code: SUN4U-8000-4Y # keys: fault.cpu.ultraSPARC-III.dcache @@ -81,13 +82,13 @@ msgstr "Fault" msgid "SUN4U-8000-4Y.severity" msgstr "Major" msgid "SUN4U-8000-4Y.description" -msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." +msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-4Y.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-4Y.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-4Y.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-53 # keys: fault.cpu.ultraSPARC-III.icache @@ -97,13 +98,13 @@ msgstr "Fault" msgid "SUN4U-8000-53.severity" msgstr "Major" msgid "SUN4U-8000-53.description" -msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." +msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-53.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-53.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-53.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-6H # keys: fault.cpu.ultraSPARC-III.l2cachedata @@ -115,11 +116,11 @@ msgstr "Major" msgid "SUN4U-8000-6H.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-6H.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-6H.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-6H.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-7D # keys: fault.cpu.ultraSPARC-III.l2cachetag @@ -131,11 +132,11 @@ msgstr "Major" msgid "SUN4U-8000-7D.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-7D.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-7D.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-7D.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-84 # keys: fault.cpu.ultraSPARC-IIIi.dcache @@ -147,11 +148,11 @@ msgstr "Major" msgid "SUN4U-8000-84.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-84.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-84.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance system may be affected." msgid "SUN4U-8000-84.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-9R # keys: fault.cpu.ultraSPARC-IIIi.icache @@ -163,11 +164,11 @@ msgstr "Major" msgid "SUN4U-8000-9R.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-9R.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-9R.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-9R.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-AC # keys: fault.cpu.ultraSPARC-IIIi.l2cachedata @@ -179,11 +180,11 @@ msgstr "Major" msgid "SUN4U-8000-AC.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-AC.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-AC.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-AC.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-CQ # keys: fault.cpu.ultraSPARC-IIIi.l2cachetag @@ -195,11 +196,11 @@ msgstr "Major" msgid "SUN4U-8000-CQ.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-CQ.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-CQ.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-CQ.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-DE # keys: fault.cpu.ultraSPARC-IIIplus.dcache @@ -211,11 +212,11 @@ msgstr "Major" msgid "SUN4U-8000-DE.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-DE.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-DE.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-DE.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-EJ # keys: fault.cpu.ultraSPARC-IIIplus.icache @@ -227,11 +228,11 @@ msgstr "Major" msgid "SUN4U-8000-EJ.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-EJ.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-EJ.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-EJ.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-F2 # keys: fault.cpu.ultraSPARC-IIIplus.l2cachedata @@ -243,11 +244,11 @@ msgstr "Major" msgid "SUN4U-8000-F2.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-F2.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-F2.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-F2.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-GX # keys: fault.cpu.ultraSPARC-IIIplus.l2cachetag @@ -261,9 +262,9 @@ msgstr "The number of errors associated with this CPU has exceeded acceptable le msgid "SUN4U-8000-GX.response" msgstr "An attempt will be made to remove the affected CPU from service." msgid "SUN4U-8000-GX.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-GX.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." # # code: SUN4U-8000-H5 # keys: fault.cpu.ultraSPARC-IV.dcache @@ -275,11 +276,11 @@ msgstr "Major" msgid "SUN4U-8000-H5.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-H5.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-H5.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-H5.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-JS # keys: fault.cpu.ultraSPARC-IV.icache @@ -291,11 +292,11 @@ msgstr "Major" msgid "SUN4U-8000-JS.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-JS.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-JS.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-JS.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-KA # keys: fault.cpu.ultraSPARC-IV.l2cachedata @@ -307,11 +308,11 @@ msgstr "Major" msgid "SUN4U-8000-KA.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-KA.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-KA.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-KA.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-LP # keys: fault.cpu.ultraSPARC-IV.l2cachetag @@ -323,11 +324,11 @@ msgstr "Major" msgid "SUN4U-8000-LP.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-LP.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-LP.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-LP.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-MD # keys: fault.cpu.ultraSPARC-III.fpu @@ -339,11 +340,11 @@ msgstr "Major" msgid "SUN4U-8000-MD.description" msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." msgid "SUN4U-8000-MD.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-MD.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-MD.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-NH # keys: fault.cpu.ultraSPARC-IIIi.fpu @@ -355,11 +356,11 @@ msgstr "Major" msgid "SUN4U-8000-NH.description" msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." msgid "SUN4U-8000-NH.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-NH.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-NH.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-P3 # keys: fault.cpu.ultraSPARC-IIIplus.fpu @@ -371,11 +372,11 @@ msgstr "Major" msgid "SUN4U-8000-P3.description" msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." msgid "SUN4U-8000-P3.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-P3.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-P3.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-QY # keys: fault.cpu.ultraSPARC-IV.fpu @@ -387,11 +388,11 @@ msgstr "Major" msgid "SUN4U-8000-QY.description" msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." msgid "SUN4U-8000-QY.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-QY.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-QY.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-RQ # keys: fault.cpu.ultraSPARC-IVplus.fpu @@ -403,11 +404,11 @@ msgstr "Major" msgid "SUN4U-8000-RQ.description" msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." msgid "SUN4U-8000-RQ.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-RQ.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-RQ.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-SC # keys: fault.cpu.ultraSPARC-IVplus.dcache @@ -419,11 +420,11 @@ msgstr "Major" msgid "SUN4U-8000-SC.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-SC.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-SC.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-SC.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-TR # keys: fault.cpu.ultraSPARC-IVplus.icache @@ -435,11 +436,11 @@ msgstr "Major" msgid "SUN4U-8000-TR.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-TR.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-TR.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-TR.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-U4 # keys: fault.cpu.ultraSPARC-IVplus.pcache @@ -451,11 +452,11 @@ msgstr "Major" msgid "SUN4U-8000-U4.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-U4.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-U4.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-U4.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-VX # keys: fault.cpu.ultraSPARC-IVplus.dtlb @@ -467,11 +468,11 @@ msgstr "Major" msgid "SUN4U-8000-VX.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-VX.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-VX.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-VX.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-W2 # keys: fault.cpu.ultraSPARC-IVplus.itlb @@ -483,11 +484,11 @@ msgstr "Major" msgid "SUN4U-8000-W2.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-W2.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-W2.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-W2.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-XJ # keys: fault.cpu.ultraSPARC-IVplus.l2cachedata @@ -499,11 +500,11 @@ msgstr "Major" msgid "SUN4U-8000-XJ.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-XJ.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-XJ.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-XJ.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-YE # keys: fault.cpu.ultraSPARC-IVplus.l2cachetag @@ -515,11 +516,11 @@ msgstr "Major" msgid "SUN4U-8000-YE.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-YE.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-YE.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8000-YE.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8001-0J # keys: fault.cpu.ultraSPARC-IVplus.l3cachedata @@ -531,11 +532,11 @@ msgstr "Major" msgid "SUN4U-8001-0J.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8001-0J.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8001-0J.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8001-0J.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8001-1E # keys: fault.cpu.ultraSPARC-IVplus.l3cachetag @@ -547,11 +548,11 @@ msgstr "Major" msgid "SUN4U-8001-1E.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8001-1E.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8001-1E.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8001-1E.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8001-2X # keys: defect.ultraSPARC-II.memory.nodiag @@ -561,7 +562,7 @@ msgstr "Defect" msgid "SUN4U-8001-2X.severity" msgstr "Minor" msgid "SUN4U-8001-2X.description" -msgstr "The Solaris Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable. Refer to %s for more information" +msgstr "The Solaris Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable. Refer to %s for more information." msgid "SUN4U-8001-2X.response" msgstr "The error information has been saved for examination by Sun." msgid "SUN4U-8001-2X.impact" @@ -593,13 +594,13 @@ msgstr "Fault" msgid "SUN4U-8001-4R.severity" msgstr "Critical" msgid "SUN4U-8001-4R.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-4R.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-4R.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-4R.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-54 # keys: defect.io.pci.driver fault.io.datapath @@ -609,13 +610,13 @@ msgstr "Fault" msgid "SUN4U-8001-54.severity" msgstr "Critical" msgid "SUN4U-8001-54.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-54.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-54.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-54.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-6Q # keys: fault.io.datapath fault.io.pci.bus @@ -625,13 +626,13 @@ msgstr "Fault" msgid "SUN4U-8001-6Q.severity" msgstr "Critical" msgid "SUN4U-8001-6Q.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-6Q.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-6Q.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-6Q.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-7C # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus @@ -641,13 +642,13 @@ msgstr "Fault" msgid "SUN4U-8001-7C.severity" msgstr "Critical" msgid "SUN4U-8001-7C.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-7C.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-7C.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-7C.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-83 # keys: fault.io.datapath fault.io.pci.device @@ -657,13 +658,13 @@ msgstr "Fault" msgid "SUN4U-8001-83.severity" msgstr "Critical" msgid "SUN4U-8001-83.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-83.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-83.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-83.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-9Y # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device @@ -673,13 +674,13 @@ msgstr "Fault" msgid "SUN4U-8001-9Y.severity" msgstr "Critical" msgid "SUN4U-8001-9Y.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-9Y.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-9Y.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-9Y.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-AD # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device @@ -689,13 +690,13 @@ msgstr "Fault" msgid "SUN4U-8001-AD.severity" msgstr "Critical" msgid "SUN4U-8001-AD.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-AD.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-AD.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-AD.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-CH # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device @@ -705,13 +706,13 @@ msgstr "Fault" msgid "SUN4U-8001-CH.severity" msgstr "Critical" msgid "SUN4U-8001-CH.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-CH.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-CH.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-CH.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-DA # keys: fault.io.hbus @@ -721,13 +722,13 @@ msgstr "Fault" msgid "SUN4U-8001-DA.severity" msgstr "Critical" msgid "SUN4U-8001-DA.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-DA.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-DA.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-DA.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-EP # keys: defect.io.pci.driver fault.io.hbus @@ -737,13 +738,13 @@ msgstr "Fault" msgid "SUN4U-8001-EP.severity" msgstr "Critical" msgid "SUN4U-8001-EP.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-EP.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-EP.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-EP.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-F5 # keys: fault.io.hbus fault.io.pci.bus @@ -753,13 +754,13 @@ msgstr "Fault" msgid "SUN4U-8001-F5.severity" msgstr "Critical" msgid "SUN4U-8001-F5.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-F5.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-F5.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-F5.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-GS # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus @@ -769,13 +770,13 @@ msgstr "Fault" msgid "SUN4U-8001-GS.severity" msgstr "Critical" msgid "SUN4U-8001-GS.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-GS.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-GS.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-GS.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-H2 # keys: fault.io.hbus fault.io.pci.device @@ -785,13 +786,13 @@ msgstr "Fault" msgid "SUN4U-8001-H2.severity" msgstr "Critical" msgid "SUN4U-8001-H2.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-H2.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-H2.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-H2.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-JX # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device @@ -801,13 +802,13 @@ msgstr "Fault" msgid "SUN4U-8001-JX.severity" msgstr "Critical" msgid "SUN4U-8001-JX.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-JX.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-JX.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-JX.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-KE # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device @@ -817,13 +818,13 @@ msgstr "Fault" msgid "SUN4U-8001-KE.severity" msgstr "Critical" msgid "SUN4U-8001-KE.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-KE.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-KE.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-KE.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-LJ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device @@ -833,13 +834,13 @@ msgstr "Fault" msgid "SUN4U-8001-LJ.severity" msgstr "Critical" msgid "SUN4U-8001-LJ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-LJ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-LJ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-LJ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-MC # keys: fault.io.datapath fault.io.hbus @@ -849,13 +850,13 @@ msgstr "Fault" msgid "SUN4U-8001-MC.severity" msgstr "Critical" msgid "SUN4U-8001-MC.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-MC.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-MC.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-MC.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-NQ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus @@ -865,13 +866,13 @@ msgstr "Fault" msgid "SUN4U-8001-NQ.severity" msgstr "Critical" msgid "SUN4U-8001-NQ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-NQ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-NQ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-NQ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-P4 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus @@ -881,13 +882,13 @@ msgstr "Fault" msgid "SUN4U-8001-P4.severity" msgstr "Critical" msgid "SUN4U-8001-P4.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-P4.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-P4.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-P4.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-QR # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus @@ -897,13 +898,13 @@ msgstr "Fault" msgid "SUN4U-8001-QR.severity" msgstr "Critical" msgid "SUN4U-8001-QR.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-QR.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-QR.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-QR.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-RH # keys: fault.io.datapath fault.io.hbus fault.io.pci.device @@ -913,13 +914,13 @@ msgstr "Fault" msgid "SUN4U-8001-RH.severity" msgstr "Critical" msgid "SUN4U-8001-RH.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-RH.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-RH.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-RH.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-SD # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device @@ -929,13 +930,13 @@ msgstr "Fault" msgid "SUN4U-8001-SD.severity" msgstr "Critical" msgid "SUN4U-8001-SD.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-SD.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-SD.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-SD.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-TY # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device @@ -945,13 +946,13 @@ msgstr "Fault" msgid "SUN4U-8001-TY.severity" msgstr "Critical" msgid "SUN4U-8001-TY.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-TY.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-TY.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-TY.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-U3 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device @@ -961,13 +962,13 @@ msgstr "Fault" msgid "SUN4U-8001-U3.severity" msgstr "Critical" msgid "SUN4U-8001-U3.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-U3.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-U3.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-U3.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-VS # keys: fault.io.schizo @@ -977,13 +978,13 @@ msgstr "Fault" msgid "SUN4U-8001-VS.severity" msgstr "Critical" msgid "SUN4U-8001-VS.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-VS.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-VS.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-VS.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-W5 # keys: defect.io.pci.driver fault.io.schizo @@ -993,13 +994,13 @@ msgstr "Fault" msgid "SUN4U-8001-W5.severity" msgstr "Critical" msgid "SUN4U-8001-W5.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-W5.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-W5.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-W5.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-XP # keys: fault.io.pci.bus fault.io.schizo @@ -1009,13 +1010,13 @@ msgstr "Fault" msgid "SUN4U-8001-XP.severity" msgstr "Critical" msgid "SUN4U-8001-XP.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-XP.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-XP.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-XP.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-YA # keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo @@ -1025,13 +1026,13 @@ msgstr "Fault" msgid "SUN4U-8001-YA.severity" msgstr "Critical" msgid "SUN4U-8001-YA.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-YA.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-YA.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-YA.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-0R # keys: fault.io.pci.device fault.io.schizo @@ -1041,13 +1042,13 @@ msgstr "Fault" msgid "SUN4U-8002-0R.severity" msgstr "Critical" msgid "SUN4U-8002-0R.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-0R.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-0R.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-0R.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-14 # keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo @@ -1057,13 +1058,13 @@ msgstr "Fault" msgid "SUN4U-8002-14.severity" msgstr "Critical" msgid "SUN4U-8002-14.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-14.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-14.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-14.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-2Q # keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1073,13 +1074,13 @@ msgstr "Fault" msgid "SUN4U-8002-2Q.severity" msgstr "Critical" msgid "SUN4U-8002-2Q.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-2Q.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-2Q.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-2Q.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-3C # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1089,13 +1090,13 @@ msgstr "Fault" msgid "SUN4U-8002-3C.severity" msgstr "Critical" msgid "SUN4U-8002-3C.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-3C.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-3C.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-3C.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-4J # keys: fault.io.datapath fault.io.schizo @@ -1105,13 +1106,13 @@ msgstr "Fault" msgid "SUN4U-8002-4J.severity" msgstr "Critical" msgid "SUN4U-8002-4J.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-4J.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-4J.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-4J.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-5E # keys: defect.io.pci.driver fault.io.datapath fault.io.schizo @@ -1121,13 +1122,13 @@ msgstr "Fault" msgid "SUN4U-8002-5E.severity" msgstr "Critical" msgid "SUN4U-8002-5E.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-5E.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-5E.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-5E.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-6X # keys: fault.io.datapath fault.io.pci.bus fault.io.schizo @@ -1137,13 +1138,13 @@ msgstr "Fault" msgid "SUN4U-8002-6X.severity" msgstr "Critical" msgid "SUN4U-8002-6X.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-6X.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-6X.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-6X.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-72 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo @@ -1153,13 +1154,13 @@ msgstr "Fault" msgid "SUN4U-8002-72.severity" msgstr "Critical" msgid "SUN4U-8002-72.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-72.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-72.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-72.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-8A # keys: fault.io.datapath fault.io.pci.device fault.io.schizo @@ -1169,13 +1170,13 @@ msgstr "Fault" msgid "SUN4U-8002-8A.severity" msgstr "Critical" msgid "SUN4U-8002-8A.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-8A.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-8A.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-8A.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-9P # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo @@ -1185,13 +1186,13 @@ msgstr "Fault" msgid "SUN4U-8002-9P.severity" msgstr "Critical" msgid "SUN4U-8002-9P.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-9P.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-9P.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-9P.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-A5 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1201,13 +1202,13 @@ msgstr "Fault" msgid "SUN4U-8002-A5.severity" msgstr "Critical" msgid "SUN4U-8002-A5.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-A5.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-A5.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-A5.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-CS # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1217,13 +1218,13 @@ msgstr "Fault" msgid "SUN4U-8002-CS.severity" msgstr "Critical" msgid "SUN4U-8002-CS.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-CS.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-CS.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-CS.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-D3 # keys: fault.io.hbus fault.io.schizo @@ -1233,13 +1234,13 @@ msgstr "Fault" msgid "SUN4U-8002-D3.severity" msgstr "Critical" msgid "SUN4U-8002-D3.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-D3.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-D3.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-D3.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-EY # keys: defect.io.pci.driver fault.io.hbus fault.io.schizo @@ -1249,13 +1250,13 @@ msgstr "Fault" msgid "SUN4U-8002-EY.severity" msgstr "Critical" msgid "SUN4U-8002-EY.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-EY.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-EY.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-EY.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-FD # keys: fault.io.hbus fault.io.pci.bus fault.io.schizo @@ -1265,13 +1266,13 @@ msgstr "Fault" msgid "SUN4U-8002-FD.severity" msgstr "Critical" msgid "SUN4U-8002-FD.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-FD.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-FD.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-FD.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-GH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo @@ -1281,13 +1282,13 @@ msgstr "Fault" msgid "SUN4U-8002-GH.severity" msgstr "Critical" msgid "SUN4U-8002-GH.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-GH.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-GH.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-GH.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-HC # keys: fault.io.hbus fault.io.pci.device fault.io.schizo @@ -1297,13 +1298,13 @@ msgstr "Fault" msgid "SUN4U-8002-HC.severity" msgstr "Critical" msgid "SUN4U-8002-HC.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-HC.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-HC.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-HC.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-JQ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo @@ -1313,13 +1314,13 @@ msgstr "Fault" msgid "SUN4U-8002-JQ.severity" msgstr "Critical" msgid "SUN4U-8002-JQ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-JQ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-JQ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-JQ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-K4 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1329,13 +1330,13 @@ msgstr "Fault" msgid "SUN4U-8002-K4.severity" msgstr "Critical" msgid "SUN4U-8002-K4.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-K4.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-K4.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-K4.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-LR # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1345,13 +1346,13 @@ msgstr "Fault" msgid "SUN4U-8002-LR.severity" msgstr "Critical" msgid "SUN4U-8002-LR.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-LR.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-LR.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-LR.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-M2 # keys: fault.io.datapath fault.io.hbus fault.io.schizo @@ -1361,13 +1362,13 @@ msgstr "Fault" msgid "SUN4U-8002-M2.severity" msgstr "Critical" msgid "SUN4U-8002-M2.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-M2.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-M2.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-M2.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-NX # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo @@ -1377,13 +1378,13 @@ msgstr "Fault" msgid "SUN4U-8002-NX.severity" msgstr "Critical" msgid "SUN4U-8002-NX.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-NX.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-NX.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-NX.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-PE # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo @@ -1393,13 +1394,13 @@ msgstr "Fault" msgid "SUN4U-8002-PE.severity" msgstr "Critical" msgid "SUN4U-8002-PE.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-PE.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-PE.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-PE.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-QJ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo @@ -1409,13 +1410,13 @@ msgstr "Fault" msgid "SUN4U-8002-QJ.severity" msgstr "Critical" msgid "SUN4U-8002-QJ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-QJ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-QJ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-QJ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-RS # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo @@ -1425,13 +1426,13 @@ msgstr "Fault" msgid "SUN4U-8002-RS.severity" msgstr "Critical" msgid "SUN4U-8002-RS.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-RS.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-RS.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-RS.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-S5 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo @@ -1441,13 +1442,13 @@ msgstr "Fault" msgid "SUN4U-8002-S5.severity" msgstr "Critical" msgid "SUN4U-8002-S5.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-S5.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-S5.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-S5.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-TP # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1457,13 +1458,13 @@ msgstr "Fault" msgid "SUN4U-8002-TP.severity" msgstr "Critical" msgid "SUN4U-8002-TP.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-TP.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-TP.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-TP.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-UA # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1473,13 +1474,13 @@ msgstr "Fault" msgid "SUN4U-8002-UA.severity" msgstr "Critical" msgid "SUN4U-8002-UA.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-UA.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-UA.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-UA.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-VH # keys: fault.io.xmits @@ -1489,13 +1490,13 @@ msgstr "Fault" msgid "SUN4U-8002-VH.severity" msgstr "Critical" msgid "SUN4U-8002-VH.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-VH.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-VH.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-VH.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-WD # keys: defect.io.pci.driver fault.io.xmits @@ -1505,13 +1506,13 @@ msgstr "Fault" msgid "SUN4U-8002-WD.severity" msgstr "Critical" msgid "SUN4U-8002-WD.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-WD.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-WD.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-WD.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-XY # keys: fault.io.pci.bus fault.io.xmits @@ -1521,13 +1522,13 @@ msgstr "Fault" msgid "SUN4U-8002-XY.severity" msgstr "Critical" msgid "SUN4U-8002-XY.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-XY.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-XY.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-XY.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-Y3 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.xmits @@ -1537,13 +1538,13 @@ msgstr "Fault" msgid "SUN4U-8002-Y3.severity" msgstr "Critical" msgid "SUN4U-8002-Y3.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-Y3.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-Y3.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-Y3.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-0Y # keys: fault.io.pci.device fault.io.xmits @@ -1553,13 +1554,13 @@ msgstr "Fault" msgid "SUN4U-8003-0Y.severity" msgstr "Critical" msgid "SUN4U-8003-0Y.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-0Y.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-0Y.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-0Y.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-13 # keys: defect.io.pci.driver fault.io.pci.device fault.io.xmits @@ -1569,13 +1570,13 @@ msgstr "Fault" msgid "SUN4U-8003-13.severity" msgstr "Critical" msgid "SUN4U-8003-13.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-13.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-13.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-13.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-2H # keys: fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1585,13 +1586,13 @@ msgstr "Fault" msgid "SUN4U-8003-2H.severity" msgstr "Critical" msgid "SUN4U-8003-2H.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-2H.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-2H.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-2H.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-3D # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1601,13 +1602,13 @@ msgstr "Fault" msgid "SUN4U-8003-3D.severity" msgstr "Critical" msgid "SUN4U-8003-3D.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-3D.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-3D.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-3D.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-4P # keys: fault.io.datapath fault.io.xmits @@ -1617,13 +1618,13 @@ msgstr "Fault" msgid "SUN4U-8003-4P.severity" msgstr "Critical" msgid "SUN4U-8003-4P.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-4P.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-4P.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-4P.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-5A # keys: defect.io.pci.driver fault.io.datapath fault.io.xmits @@ -1633,13 +1634,13 @@ msgstr "Fault" msgid "SUN4U-8003-5A.severity" msgstr "Critical" msgid "SUN4U-8003-5A.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-5A.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-5A.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-5A.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-6S # keys: fault.io.datapath fault.io.pci.bus fault.io.xmits @@ -1649,13 +1650,13 @@ msgstr "Fault" msgid "SUN4U-8003-6S.severity" msgstr "Critical" msgid "SUN4U-8003-6S.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-6S.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-6S.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-6S.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-75 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.xmits @@ -1665,13 +1666,13 @@ msgstr "Fault" msgid "SUN4U-8003-75.severity" msgstr "Critical" msgid "SUN4U-8003-75.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-75.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-75.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-75.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-8E # keys: fault.io.datapath fault.io.pci.device fault.io.xmits @@ -1681,13 +1682,13 @@ msgstr "Fault" msgid "SUN4U-8003-8E.severity" msgstr "Critical" msgid "SUN4U-8003-8E.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-8E.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-8E.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-8E.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-9J # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.xmits @@ -1697,13 +1698,13 @@ msgstr "Fault" msgid "SUN4U-8003-9J.severity" msgstr "Critical" msgid "SUN4U-8003-9J.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-9J.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-9J.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-9J.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-A2 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1713,13 +1714,13 @@ msgstr "Fault" msgid "SUN4U-8003-A2.severity" msgstr "Critical" msgid "SUN4U-8003-A2.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-A2.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-A2.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-A2.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-CX # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1729,13 +1730,13 @@ msgstr "Fault" msgid "SUN4U-8003-CX.severity" msgstr "Critical" msgid "SUN4U-8003-CX.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-CX.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-CX.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-CX.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-D4 # keys: fault.io.hbus fault.io.xmits @@ -1745,13 +1746,13 @@ msgstr "Fault" msgid "SUN4U-8003-D4.severity" msgstr "Critical" msgid "SUN4U-8003-D4.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-D4.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-D4.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-D4.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-ER # keys: defect.io.pci.driver fault.io.hbus fault.io.xmits @@ -1761,13 +1762,13 @@ msgstr "Fault" msgid "SUN4U-8003-ER.severity" msgstr "Critical" msgid "SUN4U-8003-ER.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-ER.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-ER.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-ER.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-FC # keys: fault.io.hbus fault.io.pci.bus fault.io.xmits @@ -1777,13 +1778,13 @@ msgstr "Fault" msgid "SUN4U-8003-FC.severity" msgstr "Critical" msgid "SUN4U-8003-FC.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-FC.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-FC.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-FC.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-GQ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.xmits @@ -1793,13 +1794,13 @@ msgstr "Fault" msgid "SUN4U-8003-GQ.severity" msgstr "Critical" msgid "SUN4U-8003-GQ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-GQ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-GQ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-GQ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-HD # keys: fault.io.hbus fault.io.pci.device fault.io.xmits @@ -1809,13 +1810,13 @@ msgstr "Fault" msgid "SUN4U-8003-HD.severity" msgstr "Critical" msgid "SUN4U-8003-HD.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-HD.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-HD.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-HD.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-JH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.xmits @@ -1825,13 +1826,13 @@ msgstr "Fault" msgid "SUN4U-8003-JH.severity" msgstr "Critical" msgid "SUN4U-8003-JH.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-JH.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-JH.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-JH.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-K3 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1841,13 +1842,13 @@ msgstr "Fault" msgid "SUN4U-8003-K3.severity" msgstr "Critical" msgid "SUN4U-8003-K3.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-K3.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-K3.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-K3.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-LY # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1857,13 +1858,13 @@ msgstr "Fault" msgid "SUN4U-8003-LY.severity" msgstr "Critical" msgid "SUN4U-8003-LY.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-LY.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-LY.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-LY.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-M5 # keys: fault.io.datapath fault.io.hbus fault.io.xmits @@ -1873,13 +1874,13 @@ msgstr "Fault" msgid "SUN4U-8003-M5.severity" msgstr "Critical" msgid "SUN4U-8003-M5.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-M5.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-M5.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-M5.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-NS # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.xmits @@ -1889,13 +1890,13 @@ msgstr "Fault" msgid "SUN4U-8003-NS.severity" msgstr "Critical" msgid "SUN4U-8003-NS.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-NS.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-NS.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-NS.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-PA # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits @@ -1905,13 +1906,13 @@ msgstr "Fault" msgid "SUN4U-8003-PA.severity" msgstr "Critical" msgid "SUN4U-8003-PA.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-PA.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-PA.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-PA.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-QP # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits @@ -1921,13 +1922,13 @@ msgstr "Fault" msgid "SUN4U-8003-QP.severity" msgstr "Critical" msgid "SUN4U-8003-QP.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-QP.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-QP.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-QP.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-RX # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits @@ -1937,13 +1938,13 @@ msgstr "Fault" msgid "SUN4U-8003-RX.severity" msgstr "Critical" msgid "SUN4U-8003-RX.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-RX.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-RX.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-RX.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-S2 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits @@ -1953,13 +1954,13 @@ msgstr "Fault" msgid "SUN4U-8003-S2.severity" msgstr "Critical" msgid "SUN4U-8003-S2.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-S2.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-S2.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-S2.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-TJ # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1969,13 +1970,13 @@ msgstr "Fault" msgid "SUN4U-8003-TJ.severity" msgstr "Critical" msgid "SUN4U-8003-TJ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-TJ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-TJ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-TJ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-UE # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1985,13 +1986,13 @@ msgstr "Fault" msgid "SUN4U-8003-UE.severity" msgstr "Critical" msgid "SUN4U-8003-UE.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-UE.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-UE.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-UE.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-VQ # keys: fault.io.schizo fault.io.xmits @@ -2001,13 +2002,13 @@ msgstr "Fault" msgid "SUN4U-8003-VQ.severity" msgstr "Critical" msgid "SUN4U-8003-VQ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-VQ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-VQ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-VQ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-WC # keys: defect.io.pci.driver fault.io.schizo fault.io.xmits @@ -2017,13 +2018,13 @@ msgstr "Fault" msgid "SUN4U-8003-WC.severity" msgstr "Critical" msgid "SUN4U-8003-WC.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-WC.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-WC.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-WC.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-XR # keys: fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2033,13 +2034,13 @@ msgstr "Fault" msgid "SUN4U-8003-XR.severity" msgstr "Critical" msgid "SUN4U-8003-XR.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-XR.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-XR.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-XR.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-Y4 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2049,13 +2050,13 @@ msgstr "Fault" msgid "SUN4U-8003-Y4.severity" msgstr "Critical" msgid "SUN4U-8003-Y4.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-Y4.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-Y4.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-Y4.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-0A # keys: fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2065,13 +2066,13 @@ msgstr "Fault" msgid "SUN4U-8004-0A.severity" msgstr "Critical" msgid "SUN4U-8004-0A.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-0A.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-0A.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-0A.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-1P # keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2081,13 +2082,13 @@ msgstr "Fault" msgid "SUN4U-8004-1P.severity" msgstr "Critical" msgid "SUN4U-8004-1P.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-1P.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-1P.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-1P.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-25 # keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2097,13 +2098,13 @@ msgstr "Fault" msgid "SUN4U-8004-25.severity" msgstr "Critical" msgid "SUN4U-8004-25.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-25.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-25.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-25.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-3S # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2113,13 +2114,13 @@ msgstr "Fault" msgid "SUN4U-8004-3S.severity" msgstr "Critical" msgid "SUN4U-8004-3S.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-3S.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-3S.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-3S.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-43 # keys: fault.io.datapath fault.io.schizo fault.io.xmits @@ -2129,13 +2130,13 @@ msgstr "Fault" msgid "SUN4U-8004-43.severity" msgstr "Critical" msgid "SUN4U-8004-43.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-43.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-43.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-43.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-5Y # keys: defect.io.pci.driver fault.io.datapath fault.io.schizo fault.io.xmits @@ -2145,13 +2146,13 @@ msgstr "Fault" msgid "SUN4U-8004-5Y.severity" msgstr "Critical" msgid "SUN4U-8004-5Y.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-5Y.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-5Y.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-5Y.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-6D # keys: fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2161,13 +2162,13 @@ msgstr "Fault" msgid "SUN4U-8004-6D.severity" msgstr "Critical" msgid "SUN4U-8004-6D.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-6D.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-6D.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-6D.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-7H # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2177,13 +2178,13 @@ msgstr "Fault" msgid "SUN4U-8004-7H.severity" msgstr "Critical" msgid "SUN4U-8004-7H.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-7H.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-7H.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-7H.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-8R # keys: fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2193,13 +2194,13 @@ msgstr "Fault" msgid "SUN4U-8004-8R.severity" msgstr "Critical" msgid "SUN4U-8004-8R.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-8R.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-8R.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-8R.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-94 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2209,13 +2210,13 @@ msgstr "Fault" msgid "SUN4U-8004-94.severity" msgstr "Critical" msgid "SUN4U-8004-94.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-94.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-94.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-94.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-AQ # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2225,13 +2226,13 @@ msgstr "Fault" msgid "SUN4U-8004-AQ.severity" msgstr "Critical" msgid "SUN4U-8004-AQ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-AQ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-AQ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-AQ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-CC # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2241,13 +2242,13 @@ msgstr "Fault" msgid "SUN4U-8004-CC.severity" msgstr "Critical" msgid "SUN4U-8004-CC.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-CC.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-CC.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-CC.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-DJ # keys: fault.io.hbus fault.io.schizo fault.io.xmits @@ -2257,13 +2258,13 @@ msgstr "Fault" msgid "SUN4U-8004-DJ.severity" msgstr "Critical" msgid "SUN4U-8004-DJ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-DJ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-DJ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-DJ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-EE # keys: defect.io.pci.driver fault.io.hbus fault.io.schizo fault.io.xmits @@ -2273,13 +2274,13 @@ msgstr "Fault" msgid "SUN4U-8004-EE.severity" msgstr "Critical" msgid "SUN4U-8004-EE.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-EE.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-EE.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-EE.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-FX # keys: fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2289,13 +2290,13 @@ msgstr "Fault" msgid "SUN4U-8004-FX.severity" msgstr "Critical" msgid "SUN4U-8004-FX.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-FX.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-FX.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-FX.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-G2 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2305,13 +2306,13 @@ msgstr "Fault" msgid "SUN4U-8004-G2.severity" msgstr "Critical" msgid "SUN4U-8004-G2.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-G2.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-G2.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-G2.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-HS # keys: fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2321,13 +2322,13 @@ msgstr "Fault" msgid "SUN4U-8004-HS.severity" msgstr "Critical" msgid "SUN4U-8004-HS.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-HS.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-HS.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-HS.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-J5 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2337,13 +2338,13 @@ msgstr "Fault" msgid "SUN4U-8004-J5.severity" msgstr "Critical" msgid "SUN4U-8004-J5.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-J5.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-J5.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-J5.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-KP # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2353,13 +2354,13 @@ msgstr "Fault" msgid "SUN4U-8004-KP.severity" msgstr "Critical" msgid "SUN4U-8004-KP.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-KP.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-KP.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-KP.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-LA # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2369,13 +2370,13 @@ msgstr "Fault" msgid "SUN4U-8004-LA.severity" msgstr "Critical" msgid "SUN4U-8004-LA.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-LA.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-LA.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-LA.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-MH # keys: fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits @@ -2385,13 +2386,13 @@ msgstr "Fault" msgid "SUN4U-8004-MH.severity" msgstr "Critical" msgid "SUN4U-8004-MH.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-MH.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-MH.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-MH.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-ND # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits @@ -2401,13 +2402,13 @@ msgstr "Fault" msgid "SUN4U-8004-ND.severity" msgstr "Critical" msgid "SUN4U-8004-ND.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-ND.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-ND.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-ND.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-PY # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2417,13 +2418,13 @@ msgstr "Fault" msgid "SUN4U-8004-PY.severity" msgstr "Critical" msgid "SUN4U-8004-PY.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-PY.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-PY.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-PY.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-Q3 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2433,13 +2434,13 @@ msgstr "Fault" msgid "SUN4U-8004-Q3.severity" msgstr "Critical" msgid "SUN4U-8004-Q3.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-Q3.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-Q3.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-Q3.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-RC # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2449,13 +2450,13 @@ msgstr "Fault" msgid "SUN4U-8004-RC.severity" msgstr "Critical" msgid "SUN4U-8004-RC.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-RC.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-RC.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-RC.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-SQ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2465,13 +2466,13 @@ msgstr "Fault" msgid "SUN4U-8004-SQ.severity" msgstr "Critical" msgid "SUN4U-8004-SQ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-SQ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-SQ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-SQ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-T4 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2481,13 +2482,13 @@ msgstr "Fault" msgid "SUN4U-8004-T4.severity" msgstr "Critical" msgid "SUN4U-8004-T4.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-T4.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-T4.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-T4.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-UR # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2497,13 +2498,13 @@ msgstr "Fault" msgid "SUN4U-8004-UR.severity" msgstr "Critical" msgid "SUN4U-8004-UR.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-UR.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-UR.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-UR.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-V2 # keys: fault.io.psycho @@ -2513,13 +2514,13 @@ msgstr "Fault" msgid "SUN4U-8004-V2.severity" msgstr "Critical" msgid "SUN4U-8004-V2.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-V2.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-V2.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-V2.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-WX # keys: defect.io.pci.driver fault.io.psycho @@ -2529,13 +2530,13 @@ msgstr "Fault" msgid "SUN4U-8004-WX.severity" msgstr "Critical" msgid "SUN4U-8004-WX.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-WX.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-WX.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-WX.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-XE # keys: fault.io.datapath fault.io.psycho @@ -2545,13 +2546,13 @@ msgstr "Fault" msgid "SUN4U-8004-XE.severity" msgstr "Critical" msgid "SUN4U-8004-XE.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-XE.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-XE.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-XE.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-YJ # keys: defect.io.pci.driver fault.io.datapath fault.io.psycho @@ -2561,13 +2562,13 @@ msgstr "Fault" msgid "SUN4U-8004-YJ.severity" msgstr "Critical" msgid "SUN4U-8004-YJ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-YJ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-YJ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-YJ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-0E # keys: fault.io.hbus fault.io.psycho @@ -2577,13 +2578,13 @@ msgstr "Fault" msgid "SUN4U-8005-0E.severity" msgstr "Critical" msgid "SUN4U-8005-0E.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-0E.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-0E.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-0E.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-1J # keys: defect.io.pci.driver fault.io.hbus fault.io.psycho @@ -2593,13 +2594,13 @@ msgstr "Fault" msgid "SUN4U-8005-1J.severity" msgstr "Critical" msgid "SUN4U-8005-1J.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-1J.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-1J.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-1J.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-22 # keys: fault.io.datapath fault.io.hbus fault.io.psycho @@ -2609,13 +2610,13 @@ msgstr "Fault" msgid "SUN4U-8005-22.severity" msgstr "Critical" msgid "SUN4U-8005-22.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-22.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-22.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-22.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-3X # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.psycho @@ -2625,13 +2626,13 @@ msgstr "Fault" msgid "SUN4U-8005-3X.severity" msgstr "Critical" msgid "SUN4U-8005-3X.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-3X.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-3X.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-3X.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-44 # keys: fault.io.pci.bus fault.io.psycho @@ -2641,13 +2642,13 @@ msgstr "Fault" msgid "SUN4U-8005-44.severity" msgstr "Critical" msgid "SUN4U-8005-44.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-44.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-44.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-44.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-5R # keys: defect.io.pci.driver fault.io.pci.bus fault.io.psycho @@ -2657,13 +2658,13 @@ msgstr "Fault" msgid "SUN4U-8005-5R.severity" msgstr "Critical" msgid "SUN4U-8005-5R.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-5R.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-5R.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-5R.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-6C # keys: fault.io.datapath fault.io.pci.bus fault.io.psycho @@ -2673,13 +2674,13 @@ msgstr "Fault" msgid "SUN4U-8005-6C.severity" msgstr "Critical" msgid "SUN4U-8005-6C.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-6C.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-6C.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-6C.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-7Q # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.psycho @@ -2689,13 +2690,13 @@ msgstr "Fault" msgid "SUN4U-8005-7Q.severity" msgstr "Critical" msgid "SUN4U-8005-7Q.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-7Q.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-7Q.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-7Q.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-8Y # keys: fault.io.hbus fault.io.pci.bus fault.io.psycho @@ -2705,13 +2706,13 @@ msgstr "Fault" msgid "SUN4U-8005-8Y.severity" msgstr "Critical" msgid "SUN4U-8005-8Y.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-8Y.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-8Y.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-8Y.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-93 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.psycho @@ -2721,13 +2722,13 @@ msgstr "Fault" msgid "SUN4U-8005-93.severity" msgstr "Critical" msgid "SUN4U-8005-93.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-93.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-93.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-93.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-AH # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho @@ -2737,13 +2738,13 @@ msgstr "Fault" msgid "SUN4U-8005-AH.severity" msgstr "Critical" msgid "SUN4U-8005-AH.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-AH.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-AH.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-AH.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-CD # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho @@ -2753,13 +2754,13 @@ msgstr "Fault" msgid "SUN4U-8005-CD.severity" msgstr "Critical" msgid "SUN4U-8005-CD.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-CD.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-CD.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-CD.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-DP # keys: fault.io.pci.device fault.io.psycho @@ -2769,13 +2770,13 @@ msgstr "Fault" msgid "SUN4U-8005-DP.severity" msgstr "Critical" msgid "SUN4U-8005-DP.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-DP.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-DP.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-DP.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-EA # keys: defect.io.pci.driver fault.io.pci.device fault.io.psycho @@ -2785,13 +2786,13 @@ msgstr "Fault" msgid "SUN4U-8005-EA.severity" msgstr "Critical" msgid "SUN4U-8005-EA.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-EA.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-EA.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-EA.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-FS # keys: fault.io.datapath fault.io.pci.device fault.io.psycho @@ -2801,13 +2802,13 @@ msgstr "Fault" msgid "SUN4U-8005-FS.severity" msgstr "Critical" msgid "SUN4U-8005-FS.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-FS.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-FS.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-FS.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-G5 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.psycho @@ -2817,13 +2818,13 @@ msgstr "Fault" msgid "SUN4U-8005-G5.severity" msgstr "Critical" msgid "SUN4U-8005-G5.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-G5.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-G5.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-G5.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-HX # keys: fault.io.hbus fault.io.pci.device fault.io.psycho @@ -2833,13 +2834,13 @@ msgstr "Fault" msgid "SUN4U-8005-HX.severity" msgstr "Critical" msgid "SUN4U-8005-HX.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-HX.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-HX.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-HX.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-J2 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.psycho @@ -2849,13 +2850,13 @@ msgstr "Fault" msgid "SUN4U-8005-J2.severity" msgstr "Critical" msgid "SUN4U-8005-J2.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-J2.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-J2.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-J2.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-KJ # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho @@ -2865,13 +2866,13 @@ msgstr "Fault" msgid "SUN4U-8005-KJ.severity" msgstr "Critical" msgid "SUN4U-8005-KJ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-KJ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-KJ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-KJ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-LE # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho @@ -2881,13 +2882,13 @@ msgstr "Fault" msgid "SUN4U-8005-LE.severity" msgstr "Critical" msgid "SUN4U-8005-LE.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-LE.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-LE.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-LE.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-MQ # keys: fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2897,13 +2898,13 @@ msgstr "Fault" msgid "SUN4U-8005-MQ.severity" msgstr "Critical" msgid "SUN4U-8005-MQ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-MQ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-MQ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-MQ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-NC # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2913,13 +2914,13 @@ msgstr "Fault" msgid "SUN4U-8005-NC.severity" msgstr "Critical" msgid "SUN4U-8005-NC.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-NC.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-NC.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-NC.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-PR # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2929,13 +2930,13 @@ msgstr "Fault" msgid "SUN4U-8005-PR.severity" msgstr "Critical" msgid "SUN4U-8005-PR.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-PR.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-PR.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-PR.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-Q4 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2945,13 +2946,13 @@ msgstr "Fault" msgid "SUN4U-8005-Q4.severity" msgstr "Critical" msgid "SUN4U-8005-Q4.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-Q4.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-Q4.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-Q4.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-RD # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2961,13 +2962,13 @@ msgstr "Fault" msgid "SUN4U-8005-RD.severity" msgstr "Critical" msgid "SUN4U-8005-RD.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-RD.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-RD.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-RD.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-SH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2977,13 +2978,13 @@ msgstr "Fault" msgid "SUN4U-8005-SH.severity" msgstr "Critical" msgid "SUN4U-8005-SH.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-SH.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-SH.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-SH.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-T3 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2993,13 +2994,13 @@ msgstr "Fault" msgid "SUN4U-8005-T3.severity" msgstr "Critical" msgid "SUN4U-8005-T3.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-T3.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-T3.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-T3.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-UY # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -3009,13 +3010,13 @@ msgstr "Fault" msgid "SUN4U-8005-UY.severity" msgstr "Critical" msgid "SUN4U-8005-UY.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-UY.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-UY.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-UY.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-V5 # keys: fault.io.tomatillo @@ -3025,13 +3026,13 @@ msgstr "Fault" msgid "SUN4U-8005-V5.severity" msgstr "Critical" msgid "SUN4U-8005-V5.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-V5.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-V5.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-V5.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-WS # keys: defect.io.pci.driver fault.io.tomatillo @@ -3041,13 +3042,13 @@ msgstr "Fault" msgid "SUN4U-8005-WS.severity" msgstr "Critical" msgid "SUN4U-8005-WS.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-WS.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-WS.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-WS.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-XA # keys: fault.io.datapath fault.io.tomatillo @@ -3057,13 +3058,13 @@ msgstr "Fault" msgid "SUN4U-8005-XA.severity" msgstr "Critical" msgid "SUN4U-8005-XA.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-XA.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-XA.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-XA.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-YP # keys: defect.io.pci.driver fault.io.datapath fault.io.tomatillo @@ -3073,13 +3074,13 @@ msgstr "Fault" msgid "SUN4U-8005-YP.severity" msgstr "Critical" msgid "SUN4U-8005-YP.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-YP.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-YP.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-YP.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-04 # keys: fault.io.hbus fault.io.tomatillo @@ -3089,13 +3090,13 @@ msgstr "Fault" msgid "SUN4U-8006-04.severity" msgstr "Critical" msgid "SUN4U-8006-04.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-04.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-04.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-04.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-1R # keys: defect.io.pci.driver fault.io.hbus fault.io.tomatillo @@ -3105,13 +3106,13 @@ msgstr "Fault" msgid "SUN4U-8006-1R.severity" msgstr "Critical" msgid "SUN4U-8006-1R.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-1R.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-1R.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-1R.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-2C # keys: fault.io.datapath fault.io.hbus fault.io.tomatillo @@ -3121,13 +3122,13 @@ msgstr "Fault" msgid "SUN4U-8006-2C.severity" msgstr "Critical" msgid "SUN4U-8006-2C.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-2C.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-2C.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-2C.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-3Q # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.tomatillo @@ -3137,13 +3138,13 @@ msgstr "Fault" msgid "SUN4U-8006-3Q.severity" msgstr "Critical" msgid "SUN4U-8006-3Q.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-3Q.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-3Q.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-3Q.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-4E # keys: fault.io.pci.bus fault.io.tomatillo @@ -3153,13 +3154,13 @@ msgstr "Fault" msgid "SUN4U-8006-4E.severity" msgstr "Critical" msgid "SUN4U-8006-4E.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-4E.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-4E.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-4E.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-5J # keys: defect.io.pci.driver fault.io.pci.bus fault.io.tomatillo @@ -3169,13 +3170,13 @@ msgstr "Fault" msgid "SUN4U-8006-5J.severity" msgstr "Critical" msgid "SUN4U-8006-5J.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-5J.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-5J.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-5J.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-62 # keys: fault.io.datapath fault.io.pci.bus fault.io.tomatillo @@ -3185,13 +3186,13 @@ msgstr "Fault" msgid "SUN4U-8006-62.severity" msgstr "Critical" msgid "SUN4U-8006-62.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-62.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-62.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-62.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-7X # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.tomatillo @@ -3201,13 +3202,13 @@ msgstr "Fault" msgid "SUN4U-8006-7X.severity" msgstr "Critical" msgid "SUN4U-8006-7X.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-7X.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-7X.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-7X.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-8P # keys: fault.io.hbus fault.io.pci.bus fault.io.tomatillo @@ -3217,13 +3218,13 @@ msgstr "Fault" msgid "SUN4U-8006-8P.severity" msgstr "Critical" msgid "SUN4U-8006-8P.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-8P.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-8P.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-8P.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-9A # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.tomatillo @@ -3233,13 +3234,13 @@ msgstr "Fault" msgid "SUN4U-8006-9A.severity" msgstr "Critical" msgid "SUN4U-8006-9A.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-9A.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-9A.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-9A.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-AS # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo @@ -3249,13 +3250,13 @@ msgstr "Fault" msgid "SUN4U-8006-AS.severity" msgstr "Critical" msgid "SUN4U-8006-AS.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-AS.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-AS.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-AS.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-C5 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo @@ -3265,13 +3266,13 @@ msgstr "Fault" msgid "SUN4U-8006-C5.severity" msgstr "Critical" msgid "SUN4U-8006-C5.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-C5.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-C5.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-C5.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-DY # keys: fault.io.pci.device fault.io.tomatillo @@ -3281,13 +3282,13 @@ msgstr "Fault" msgid "SUN4U-8006-DY.severity" msgstr "Critical" msgid "SUN4U-8006-DY.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-DY.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-DY.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-DY.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-E3 # keys: defect.io.pci.driver fault.io.pci.device fault.io.tomatillo @@ -3297,13 +3298,13 @@ msgstr "Fault" msgid "SUN4U-8006-E3.severity" msgstr "Critical" msgid "SUN4U-8006-E3.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-E3.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-E3.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-E3.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-FH # keys: fault.io.datapath fault.io.pci.device fault.io.tomatillo @@ -3313,13 +3314,13 @@ msgstr "Fault" msgid "SUN4U-8006-FH.severity" msgstr "Critical" msgid "SUN4U-8006-FH.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-FH.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-FH.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-FH.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-GD # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.tomatillo @@ -3329,13 +3330,13 @@ msgstr "Fault" msgid "SUN4U-8006-GD.severity" msgstr "Critical" msgid "SUN4U-8006-GD.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-GD.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-GD.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-GD.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-HQ # keys: fault.io.hbus fault.io.pci.device fault.io.tomatillo @@ -3345,13 +3346,13 @@ msgstr "Fault" msgid "SUN4U-8006-HQ.severity" msgstr "Critical" msgid "SUN4U-8006-HQ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-HQ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-HQ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-HQ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-JC # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.tomatillo @@ -3361,13 +3362,13 @@ msgstr "Fault" msgid "SUN4U-8006-JC.severity" msgstr "Critical" msgid "SUN4U-8006-JC.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-JC.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-JC.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-JC.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-KR # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo @@ -3377,13 +3378,13 @@ msgstr "Fault" msgid "SUN4U-8006-KR.severity" msgstr "Critical" msgid "SUN4U-8006-KR.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-KR.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-KR.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-KR.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-L4 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo @@ -3393,13 +3394,13 @@ msgstr "Fault" msgid "SUN4U-8006-L4.severity" msgstr "Critical" msgid "SUN4U-8006-L4.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-L4.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-L4.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-L4.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-MX # keys: fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3409,13 +3410,13 @@ msgstr "Fault" msgid "SUN4U-8006-MX.severity" msgstr "Critical" msgid "SUN4U-8006-MX.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-MX.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-MX.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-MX.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-N2 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3425,13 +3426,13 @@ msgstr "Fault" msgid "SUN4U-8006-N2.severity" msgstr "Critical" msgid "SUN4U-8006-N2.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-N2.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-N2.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-N2.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-PJ # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3441,13 +3442,13 @@ msgstr "Fault" msgid "SUN4U-8006-PJ.severity" msgstr "Critical" msgid "SUN4U-8006-PJ.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-PJ.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-PJ.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-PJ.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-QE # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3457,13 +3458,13 @@ msgstr "Fault" msgid "SUN4U-8006-QE.severity" msgstr "Critical" msgid "SUN4U-8006-QE.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-QE.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-QE.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-QE.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-R5 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3473,13 +3474,13 @@ msgstr "Fault" msgid "SUN4U-8006-R5.severity" msgstr "Critical" msgid "SUN4U-8006-R5.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-R5.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-R5.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-R5.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-SS # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3489,13 +3490,13 @@ msgstr "Fault" msgid "SUN4U-8006-SS.severity" msgstr "Critical" msgid "SUN4U-8006-SS.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-SS.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-SS.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-SS.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-TA # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3505,13 +3506,13 @@ msgstr "Fault" msgid "SUN4U-8006-TA.severity" msgstr "Critical" msgid "SUN4U-8006-TA.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-TA.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-TA.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-TA.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-UP # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3521,13 +3522,13 @@ msgstr "Fault" msgid "SUN4U-8006-UP.severity" msgstr "Critical" msgid "SUN4U-8006-UP.description" -msgstr "A problem has been detected in the PCI subsystem. Refer to %s for more information." +msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-UP.response" -msgstr "One or more device instances may be disabled" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-UP.impact" -msgstr "Loss of services provided by the device instances associated with this fault" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-UP.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-VD # keys: fault.cpu.ultraSPARC-IIIiplus.dcache @@ -3537,13 +3538,13 @@ msgstr "Fault" msgid "SUN4U-8006-VD.severity" msgstr "Major" msgid "SUN4U-8006-VD.description" -msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." +msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8006-VD.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8006-VD.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8006-VD.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8006-WH # keys: fault.cpu.ultraSPARC-IIIiplus.icache @@ -3553,13 +3554,13 @@ msgstr "Fault" msgid "SUN4U-8006-WH.severity" msgstr "Major" msgid "SUN4U-8006-WH.description" -msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." +msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8006-WH.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8006-WH.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8006-WH.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8006-X3 # keys: fault.cpu.ultraSPARC-IIIiplus.l2cachedata @@ -3569,13 +3570,13 @@ msgstr "Fault" msgid "SUN4U-8006-X3.severity" msgstr "Major" msgid "SUN4U-8006-X3.description" -msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." +msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8006-X3.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8006-X3.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8006-X3.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8006-YY # keys: fault.cpu.ultraSPARC-IIIiplus.l2cachetag @@ -3585,13 +3586,13 @@ msgstr "Fault" msgid "SUN4U-8006-YY.severity" msgstr "Major" msgid "SUN4U-8006-YY.description" -msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." +msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8006-YY.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8006-YY.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8006-YY.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8007-03 # keys: fault.cpu.ultraSPARC-IIIiplus.fpu @@ -3601,13 +3602,13 @@ msgstr "Fault" msgid "SUN4U-8007-03.severity" msgstr "Major" msgid "SUN4U-8007-03.description" -msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." +msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8007-03.response" -msgstr "An attempt will be made to remove the affected CPU from service." +msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8007-03.impact" -msgstr "Performance of this system may be affected." +msgstr "System performance may be affected." msgid "SUN4U-8007-03.action" -msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." +msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8007-1Y # keys: fault.asic.cds.dp @@ -3617,13 +3618,13 @@ msgstr "Fault" msgid "SUN4U-8007-1Y.severity" msgstr "Critical" msgid "SUN4U-8007-1Y.description" -msgstr "A hardware problem was detected on the datapath interconnect. Refer to %s for more information." +msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." msgid "SUN4U-8007-1Y.response" -msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled." +msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" msgid "SUN4U-8007-1Y.impact" -msgstr "System performace may be affected." +msgstr "System performace may be affected.\n" msgid "SUN4U-8007-1Y.action" -msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative." +msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative.\n" # # code: SUN4U-8007-2D # keys: fault.asic.dx.dp @@ -3633,13 +3634,13 @@ msgstr "Fault" msgid "SUN4U-8007-2D.severity" msgstr "Critical" msgid "SUN4U-8007-2D.description" -msgstr "A hardware problem was detected on the datapath interconnect. Refer to %s for more information." +msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." msgid "SUN4U-8007-2D.response" -msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled." +msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" msgid "SUN4U-8007-2D.impact" -msgstr "System performace may be affected." +msgstr "System performace may be affected.\n" msgid "SUN4U-8007-2D.action" -msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative." +msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative.\n" # # code: SUN4U-8007-3H # keys: fault.asic.sdi.dp @@ -3649,13 +3650,13 @@ msgstr "Fault" msgid "SUN4U-8007-3H.severity" msgstr "Critical" msgid "SUN4U-8007-3H.description" -msgstr "A hardware problem was detected on the datapath interconnect. Refer to %s for more information." +msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." msgid "SUN4U-8007-3H.response" -msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled." +msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" msgid "SUN4U-8007-3H.impact" -msgstr "System performace may be affected." +msgstr "System performace may be affected.\n" msgid "SUN4U-8007-3H.action" -msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative." +msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative.\n" # # code: SUN4U-8007-4A # keys: fault.asic.cp.dp @@ -3665,13 +3666,13 @@ msgstr "Fault" msgid "SUN4U-8007-4A.severity" msgstr "Critical" msgid "SUN4U-8007-4A.description" -msgstr "A hardware problem was detected on the datapath interconnect. Refer to %s for more information." +msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." msgid "SUN4U-8007-4A.response" -msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled." +msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" msgid "SUN4U-8007-4A.impact" -msgstr "System performace may be affected." +msgstr "System performace may be affected.\n" msgid "SUN4U-8007-4A.action" -msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative." +msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative.\n" # # code: SUN4U-8007-5P # keys: fault.asic.rp.dp @@ -3681,10 +3682,74 @@ msgstr "Fault" msgid "SUN4U-8007-5P.severity" msgstr "Critical" msgid "SUN4U-8007-5P.description" -msgstr "A hardware problem was detected on the datapath interconnect. Refer to %s for more information." +msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." msgid "SUN4U-8007-5P.response" -msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled." +msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" msgid "SUN4U-8007-5P.impact" -msgstr "System performace may be affected." +msgstr "System performace may be affected.\n" msgid "SUN4U-8007-5P.action" -msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative." +msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative.\n" +# +# code: SUN4U-8007-65 +# keys: fault.io.oberon +# +msgid "SUN4U-8007-65.type" +msgstr "Fault" +msgid "SUN4U-8007-65.severity" +msgstr "Critical" +msgid "SUN4U-8007-65.description" +msgstr "Oberon PCI-Express hostbridge fault\n Refer to %s for more information." +msgid "SUN4U-8007-65.response" +msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." +msgid "SUN4U-8007-65.impact" +msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." +msgid "SUN4U-8007-65.action" +msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +# +# code: SUN4U-8007-7S +# keys: fault.cpu.SPARC64-VI.chip +# +msgid "SUN4U-8007-7S.type" +msgstr "Fault" +msgid "SUN4U-8007-7S.severity" +msgstr "Critical" +msgid "SUN4U-8007-7S.description" +msgstr "The number of errors associated with this CHIP has exceeded acceptable levels.\nRefer to %s for more information.\n Refer to %s for more information." +msgid "SUN4U-8007-7S.response" +msgstr "An attempt will be made to remove the affected CHIP from service.\n" +msgid "SUN4U-8007-7S.impact" +msgstr "The system will not be functioning at the same performance level with the CHIP removal.\n" +msgid "SUN4U-8007-7S.action" +msgstr "Schedule a repair procedure to replace the affected CHIP. Use fmdump -v -u\n to identify the smallest CPU/Strand ID of the affected CORE on this\nCHIP.\n" +# +# code: SUN4U-8007-8J +# keys: fault.cpu.SPARC64-VI.core +# +msgid "SUN4U-8007-8J.type" +msgstr "Fault" +msgid "SUN4U-8007-8J.severity" +msgstr "Critical" +msgid "SUN4U-8007-8J.description" +msgstr "The number of errors associated with this CHIP has exceeded acceptable levels.\nRefer to %s for more information.\n Refer to %s for more information." +msgid "SUN4U-8007-8J.response" +msgstr "An attempt will be made to remove the affected CORE from service.\n" +msgid "SUN4U-8007-8J.impact" +msgstr "The system will not be functioning at the same performance level with the CORE removal.\n" +msgid "SUN4U-8007-8J.action" +msgstr "Schedule a repair procedure to replace the affected CORE. Use fmdump -v -u\n to identify the smallest CPU/Strand ID of the affected CORE on this\nCORE.\n" +# +# code: SUN4U-8007-9E +# keys: fault.cpu.SPARC64-VI.strand +# +msgid "SUN4U-8007-9E.type" +msgstr "Fault" +msgid "SUN4U-8007-9E.severity" +msgstr "Critical" +msgid "SUN4U-8007-9E.description" +msgstr "The number of errors associated with this STRAND has exceeded acceptable levels.\nRefer to %s for more information.\n Refer to %s for more information." +msgid "SUN4U-8007-9E.response" +msgstr "An attempt will be made to remove the affected STRAND from service.\n" +msgid "SUN4U-8007-9E.impact" +msgstr "The system will not be functioning at the same performance level with the STRAND removal.\n" +msgid "SUN4U-8007-9E.action" +msgstr "Schedule a repair procedure to replace the affected STRAND. Use fmdump -v -u\n to identify the smallest CPU/Strand ID of the affected CORE on this\nSTRAND.\n" diff --git a/usr/src/cmd/fm/eversholt/files/sparc/sun4u/Makefile b/usr/src/cmd/fm/eversholt/files/sparc/sun4u/Makefile index 51cc35a7c4..630ed0348e 100644 --- a/usr/src/cmd/fm/eversholt/files/sparc/sun4u/Makefile +++ b/usr/src/cmd/fm/eversholt/files/sparc/sun4u/Makefile @@ -2,9 +2,8 @@ # CDDL HEADER START # # The contents of this file are subject to the terms of the -# Common Development and Distribution License, Version 1.0 only -# (the "License"). You may not use this file except in compliance -# with the License. +# Common Development and Distribution License (the "License"). +# You may not use this file except in compliance with the License. # # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE # or http://www.opensolaris.org/os/licensing. @@ -20,7 +19,7 @@ # CDDL HEADER END # # -# Copyright 2005 Sun Microsystems, Inc. All rights reserved. +# Copyright 2006 Sun Microsystems, Inc. All rights reserved. # Use is subject to license terms. # #ident "%Z%%M% %I% %E% SMI" @@ -28,7 +27,7 @@ include ../sun4/Makefile.sun4 EFT_PLAT= sun4u -SUN4UEFTFILES= schizo.eft psycho.eft tomatillo.eft xmits.eft +SUN4UEFTFILES= schizo.eft psycho.eft tomatillo.eft xmits.eft oberon.eft EFT_PLAT_FILES= $(SUN4UEFTFILES) $(SUN4EFTFILES) include ../../Makefile.com diff --git a/usr/src/cmd/fm/eversholt/files/sparc/sun4u/oberon.esc b/usr/src/cmd/fm/eversholt/files/sparc/sun4u/oberon.esc new file mode 100644 index 0000000000..6bf20dc659 --- /dev/null +++ b/usr/src/cmd/fm/eversholt/files/sparc/sun4u/oberon.esc @@ -0,0 +1,155 @@ +/* + * CDDL HEADER START + * + * The contents of this file are subject to the terms of the + * Common Development and Distribution License (the "License"). + * You may not use this file except in compliance with the License. + * + * You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE + * or http://www.opensolaris.org/os/licensing. + * See the License for the specific language governing permissions + * and limitations under the License. + * + * When distributing Covered Code, include this CDDL HEADER in each + * file and include the License file at usr/src/OPENSOLARIS.LICENSE. + * If applicable, add the following below this CDDL HEADER, with the + * fields enclosed by brackets "[]" replaced with your own identifying + * information: Portions Copyright [yyyy] [name of copyright owner] + * + * CDDL HEADER END + */ +/* + * Copyright 2006 Sun Microsystems, Inc. All rights reserved. + * Use is subject to license terms. + */ + +#pragma ident "%Z%%M% %I% %E% SMI" + +/* + * Eversholt rules for Oberon ASICs + */ + +#pragma dictionary "SUN4U" + +#define HB_FIT 1000 + +/* + * Test for primary or secondary ereports + */ +#define IS_PRIMARY (payloadprop("primary")) +#define IS_SECONDARY (! payloadprop("primary")) + +event error.io.oberon.pec.secondary@hostbridge/pciexrc; +event error.io.oberon.pec.fabric_error@hostbridge/pciexrc; + +/* + * Ereports derived from the + * UBC Status Clear Register + * + * dmarduea-channel DMA read uncorrectable error (UE) in leaf A + * dmawtuea DMA write UE in leaf A + * memrdaxa Memory read invalid address error in leaf A + * memwtaxa Memory write invalid address error in leaf A + * dmardueb-channel DMA read uncorrectable error (UE) in leaf B + * dmawtueb DMA write UE in leaf B + * memrdaxb Memory read invalid address error in leaf B + * memwtaxb Memory write invalid address error in leaf B + * piowtue-channel PIO write UE + * piowbeue-channel PIO write byte enable UE + * piorbeue-channel PIO read byte enable UE + */ +event ereport.io.oberon.ubc.dmarduea-channel@hostbridge/pciexrc{within(5s)}; +event ereport.io.oberon.ubc.dmawtuea@hostbridge/pciexrc{within(5s)}; +event ereport.io.oberon.ubc.memrdaxa@hostbridge/pciexrc{within(5s)}; +event ereport.io.oberon.ubc.memwtaxa@hostbridge/pciexrc{within(5s)}; +event ereport.io.oberon.ubc.dmardueb-channel@hostbridge/pciexrc{within(5s)}; +event ereport.io.oberon.ubc.dmawtueb@hostbridge/pciexrc{within(5s)}; +event ereport.io.oberon.ubc.memrdaxb@hostbridge/pciexrc{within(5s)}; +event ereport.io.oberon.ubc.memwtaxb@hostbridge/pciexrc{within(5s)}; +event ereport.io.oberon.ubc.piowtue-channel@hostbridge/pciexrc{within(5s)}; +event ereport.io.oberon.ubc.piowbeue-channel@hostbridge/pciexrc{within(5s)}; +event ereport.io.oberon.ubc.piorbeue-channel@hostbridge/pciexrc{within(5s)}; + +/* + * tlueitmo TLU Egress Issue Timeout + */ +event ereport.io.oberon.pec.tlueitmo@hostbridge/pciexrc{within(5s)}; + +/* + * TLU Uncorrectable and Correctable ereports + * + * ecrc End-to-end CRC error + */ +event ereport.io.oberon.pec.ecrc@hostbridge/pciexrc{within(5s)}; + +/* + * A faulty Oberon may cause; + * + * - DMA write internal RAM UE: dmawtuea, dmawtueb + * - TLU ECRC + * + * Errors marked with * may cause PCI-E abort + */ + +fru hostbridge/pciexrc; +asru hostbridge/pciexrc; +event fault.io.oberon@hostbridge/pciexrc, + FITrate=HB_FIT, FRU=hostbridge/pciexrc, ASRU=hostbridge/pciexrc; +prop fault.io.oberon@hostbridge/pciexrc (0)-> + ereport.io.oberon.ubc.dmawtuea@hostbridge/pciexrc, + ereport.io.oberon.ubc.dmawtueb@hostbridge/pciexrc, + ereport.io.oberon.pec.ecrc@hostbridge/pciexrc { IS_PRIMARY }; + +/* + * A faulty PX nexus driver can cause + * - Jbus unmapped error + * - mmu invalid, out of range, protection etc. all except data parity + * - invalid pio r/w + * - unsolicited read or interrupt return + * - msg received to unenabled queue + */ + +event defect.io.fire.pciex.driver@hostbridge/pciexrc; + +prop defect.io.fire.pciex.driver@hostbridge/pciexrc (0)-> + ereport.io.oberon.ubc.memrdaxa@hostbridge/pciexrc, + ereport.io.oberon.ubc.memrdaxb@hostbridge/pciexrc, + ereport.io.oberon.ubc.memwtaxa@hostbridge/pciexrc, + ereport.io.oberon.ubc.memwtaxb@hostbridge/pciexrc; + +/* + * Secondary errors of the ereport that the device is at fault. + * Undiagnosed the secondary errors since the payload is invalid. + */ +prop error.io.oberon.pec.secondary@hostbridge/pciexrc (0) -> + ereport.io.oberon.pec.ecrc@hostbridge/pciexrc{ IS_SECONDARY }; + +/* + * For logging purpose only. + * The px nexus driver generates equivalent pciex ereports for the + * common pciex rules to diagnose. + */ +prop error.io.oberon.pec.fabric_error@hostbridge/pciexrc(0) -> + ereport.io.oberon.pec.ecrc@hostbridge/pciexrc; + +event ereport.io.oberon.nodiag@hostbridge; + +/* + * Upset used to hide ereports that are not currently diagnosed. + */ +engine serd.io.oberon.nodiag@hostbridge, + N=1000, T=1s, method=persistent, + trip=ereport.io.oberon.nodiag@hostbridge; + +event upset.io.oberon.nodiag@hostbridge, + engine=serd.io.oberon.nodiag@hostbridge; + +prop upset.io.oberon.nodiag@hostbridge (0)-> + ereport.io.oberon.ubc.dmarduea-channel@hostbridge/pciexrc, + ereport.io.oberon.ubc.dmardueb-channel@hostbridge/pciexrc, + ereport.io.oberon.ubc.piowtue-channel@hostbridge/pciexrc, + ereport.io.oberon.ubc.piowbeue-channel@hostbridge/pciexrc, + ereport.io.oberon.ubc.piorbeue-channel@hostbridge/pciexrc, + ereport.io.oberon.pec.tlueitmo@hostbridge/pciexrc, + error.io.oberon.pec.fabric_error@hostbridge/pciexrc, + ereport.io.oberon.nodiag@hostbridge; diff --git a/usr/src/cmd/fm/modules/Makefile b/usr/src/cmd/fm/modules/Makefile index ab5810ea52..ae81c5585a 100644 --- a/usr/src/cmd/fm/modules/Makefile +++ b/usr/src/cmd/fm/modules/Makefile @@ -2,9 +2,8 @@ # CDDL HEADER START # # The contents of this file are subject to the terms of the -# Common Development and Distribution License, Version 1.0 only -# (the "License"). You may not use this file except in compliance -# with the License. +# Common Development and Distribution License (the "License"). +# You may not use this file except in compliance with the License. # # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE # or http://www.opensolaris.org/os/licensing. @@ -20,12 +19,12 @@ # CDDL HEADER END # # -# Copyright 2005 Sun Microsystems, Inc. All rights reserved. +# Copyright 2006 Sun Microsystems, Inc. All rights reserved. # Use is subject to license terms. # #ident "%Z%%M% %I% %E% SMI" -sparc_SUBDIRS = sun4u sun4v +sparc_SUBDIRS = sun4u sun4v SUNW,SPARC-Enterprise i386_SUBDIRS = SUBDIRS = common $($(MACH)_SUBDIRS) diff --git a/usr/src/cmd/fm/modules/SUNW,SPARC-Enterprise/Makefile b/usr/src/cmd/fm/modules/SUNW,SPARC-Enterprise/Makefile new file mode 100644 index 0000000000..5772a37f9f --- /dev/null +++ b/usr/src/cmd/fm/modules/SUNW,SPARC-Enterprise/Makefile @@ -0,0 +1,29 @@ +# +# CDDL HEADER START +# +# The contents of this file are subject to the terms of the +# Common Development and Distribution License (the "License"). +# You may not use this file except in compliance with the License. +# +# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE +# or http://www.opensolaris.org/os/licensing. +# See the License for the specific language governing permissions +# and limitations under the License. +# +# When distributing Covered Code, include this CDDL HEADER in each +# file and include the License file at usr/src/OPENSOLARIS.LICENSE. +# If applicable, add the following below this CDDL HEADER, with the +# fields enclosed by brackets "[]" replaced with your own identifying +# information: Portions Copyright [yyyy] [name of copyright owner] +# +# CDDL HEADER END +# +# +# Copyright 2006 Sun Microsystems, Inc. All rights reserved. +# Use is subject to license terms. +# +#ident "%Z%%M% %I% %E% SMI" + +SUBDIRS = event-transport + +include ../../Makefile.subdirs diff --git a/usr/src/cmd/fm/modules/SUNW,SPARC-Enterprise/event-transport/Makefile b/usr/src/cmd/fm/modules/SUNW,SPARC-Enterprise/event-transport/Makefile new file mode 100644 index 0000000000..c45119ca68 --- /dev/null +++ b/usr/src/cmd/fm/modules/SUNW,SPARC-Enterprise/event-transport/Makefile @@ -0,0 +1,36 @@ +# +# CDDL HEADER START +# +# The contents of this file are subject to the terms of the +# Common Development and Distribution License (the "License"). +# You may not use this file except in compliance with the License. +# +# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE +# or http://www.opensolaris.org/os/licensing. +# See the License for the specific language governing permissions +# and limitations under the License. +# +# When distributing Covered Code, include this CDDL HEADER in each +# file and include the License file at usr/src/OPENSOLARIS.LICENSE. +# If applicable, add the following below this CDDL HEADER, with the +# fields enclosed by brackets "[]" replaced with your own identifying +# information: Portions Copyright [yyyy] [name of copyright owner] +# +# CDDL HEADER END +# +# +# Copyright 2006 Sun Microsystems, Inc. All rights reserved. +# Use is subject to license terms. +# +#ident "%Z%%M% %I% %E% SMI" + +PLATFORMS = SUNW,SPARC-Enterprise + +$(PLATFORMS)_SRCS = ex_dscp.c + +LIBDIRS = $(ROOT)/usr/platform/$(PLATFORMS)/lib +LIBFLAGS = \$$ORIGIN/../../../../lib +XPORTLIBS = -lsocket -lnsl -ldscp + +include ../../common/event-transport/Makefile.etm + diff --git a/usr/src/cmd/fm/modules/SUNW,SPARC-Enterprise/event-transport/event-transport.conf b/usr/src/cmd/fm/modules/SUNW,SPARC-Enterprise/event-transport/event-transport.conf new file mode 100644 index 0000000000..f7875fc840 --- /dev/null +++ b/usr/src/cmd/fm/modules/SUNW,SPARC-Enterprise/event-transport/event-transport.conf @@ -0,0 +1,80 @@ +# +# CDDL HEADER START +# +# The contents of this file are subject to the terms of the +# Common Development and Distribution License (the "License"). +# You may not use this file except in compliance with the License. +# +# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE +# or http://www.opensolaris.org/os/licensing. +# See the License for the specific language governing permissions +# and limitations under the License. +# +# When distributing Covered Code, include this CDDL HEADER in each +# file and include the License file at usr/src/OPENSOLARIS.LICENSE. +# If applicable, add the following below this CDDL HEADER, with the +# fields enclosed by brackets "[]" replaced with your own identifying +# information: Portions Copyright [yyyy] [name of copyright owner] +# +# CDDL HEADER END +# +# +# Copyright 2006 Sun Microsystems, Inc. All rights reserved. +# Use is subject to license terms. +# +#ident "%Z%%M% %I% %E% SMI" +# +# fmd configuration file for the event-transport.so plugin module. +# +# The following configuration options are valid: +# +# setprop reconnect_timeout