blob: 1c2b54589675ef83ca873434ac174b87f2034652 (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
|
#
# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
#
# CDDL HEADER START
#
# The contents of this file are subject to the terms of the
# Common Development and Distribution License (the "License").
# You may not use this file except in compliance with the License.
#
# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
# or http://www.opensolaris.org/os/licensing.
# See the License for the specific language governing permissions
# and limitations under the License.
#
# When distributing Covered Code, include this CDDL HEADER in each
# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
# If applicable, add the following below this CDDL HEADER, with the
# fields enclosed by brackets "[]" replaced with your own identifying
# information: Portions Copyright [yyyy] [name of copyright owner]
#
# CDDL HEADER END
#
# DO NOT EDIT -- this file is generated by the Event Registry.
#
#
# General-purpose messages
#
msgid "syslog-msgs-message-template"
msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n"
#
# Fault-related messages
#
#
#
# code: FMD-8000-0W
# keys: defect.sunos.fmd.nosub
#
msgid "FMD-8000-0W.type"
msgstr "Defect"
msgid "FMD-8000-0W.severity"
msgstr "Minor"
msgid "FMD-8000-0W.description"
msgstr "The Solaris Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed. Refer to %s for more information."
msgid "FMD-8000-0W.response"
msgstr "Error reports from the component will be logged for examination by Sun."
msgid "FMD-8000-0W.impact"
msgstr "Automated diagnosis and response for these events will not occur."
msgid "FMD-8000-0W.action"
msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support."
#
# code: FMD-8000-11
# keys: defect.sunos.fmd.nodiagcode
#
msgid "FMD-8000-11.type"
msgstr "Defect"
msgid "FMD-8000-11.severity"
msgstr "Minor"
msgid "FMD-8000-11.description"
msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists. Refer to %s for more information."
msgid "FMD-8000-11.response"
msgstr "The diagnosis has been saved in the fault log for examination by Sun."
msgid "FMD-8000-11.impact"
msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
msgid "FMD-8000-11.action"
msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly."
#
# code: FMD-8000-2K
# keys: defect.sunos.fmd.module
#
msgid "FMD-8000-2K.type"
msgstr "Defect"
msgid "FMD-8000-2K.severity"
msgstr "Minor"
msgid "FMD-8000-2K.description"
msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled. Refer to %s for more information."
msgid "FMD-8000-2K.response"
msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis."
msgid "FMD-8000-2K.impact"
msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
msgid "FMD-8000-2K.action"
msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm reset <module> to reset the module."
#
# code: FMD-8000-3F
# keys: defect.sunos.fmd.config
#
msgid "FMD-8000-3F.type"
msgstr "Defect"
msgid "FMD-8000-3F.severity"
msgstr "Minor"
msgid "FMD-8000-3F.description"
msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file. Refer to %s for more information."
msgid "FMD-8000-3F.response"
msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis."
msgid "FMD-8000-3F.impact"
msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
msgid "FMD-8000-3F.action"
msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm load <module> to load the module after repairing its configuration."
#
# code: FMD-8000-4M
# keys: list.repaired
#
msgid "FMD-8000-4M.type"
msgstr "Repair"
msgid "FMD-8000-4M.severity"
msgstr "Minor"
msgid "FMD-8000-4M.description"
msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information."
msgid "FMD-8000-4M.response"
msgstr "Some system components offlined because of the original fault may have been brought back online."
msgid "FMD-8000-4M.impact"
msgstr "Performance degradation of the system due to the original fault may have been recovered."
msgid "FMD-8000-4M.action"
msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
#
# code: FMD-8000-58
# keys: list.updated
#
msgid "FMD-8000-58.type"
msgstr "Update"
msgid "FMD-8000-58.severity"
msgstr "Minor"
msgid "FMD-8000-58.description"
msgstr "Some faults associated with an event id have been addressed.\n Refer to %s for more information."
msgid "FMD-8000-58.response"
msgstr "Some system components offlined because of the original fault may have been brought back online."
msgid "FMD-8000-58.impact"
msgstr "Performance degradation of the system due to the original fault may have been recovered."
msgid "FMD-8000-58.action"
msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired."
#
# code: FMD-8000-6U
# keys: list.resolved
#
msgid "FMD-8000-6U.type"
msgstr "Resolved"
msgid "FMD-8000-6U.severity"
msgstr "Minor"
msgid "FMD-8000-6U.description"
msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information."
msgid "FMD-8000-6U.response"
msgstr "All system components offlined because of the original fault have been brought back online."
msgid "FMD-8000-6U.impact"
msgstr "Performance degradation of the system due to the original fault has been recovered."
msgid "FMD-8000-6U.action"
msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
|