summaryrefslogtreecommitdiff
path: root/usr/src/man/man1m/svadm.1m
blob: 1f923fc99d5b266796b0c0fd74ef08f203fada19 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
'\" te
.\"  Copyright (c) 2007, Sun Microsystems, Inc.  All rights reserved.
.\" The contents of this file are subject to the terms of the Common Development and Distribution License (the "License").  You may not use this file except in compliance with the License.
.\" You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE or http://www.opensolaris.org/os/licensing.  See the License for the specific language governing permissions and limitations under the License.
.\" When distributing Covered Code, include this CDDL HEADER in each file and include the License file at usr/src/OPENSOLARIS.LICENSE.  If applicable, add the following below this CDDL HEADER, with the fields enclosed by brackets "[]" replaced with your own identifying information: Portions Copyright [yyyy] [name of copyright owner]
.TH SVADM 1M "Oct 2, 2007"
.SH NAME
svadm \- command line interface to control Availability Suite Storage Volume
operations
.SH SYNOPSIS
.LP
.nf
\fBsvadm\fR \fB-h\fR
.fi

.LP
.nf
\fBsvadm\fR \fB-v\fR
.fi

.LP
.nf
\fBsvadm\fR [\fB-C\fR \fItag\fR]
.fi

.LP
.nf
\fBsvadm\fR [\fB-C\fR \fItag\fR] \fB-i\fR
.fi

.LP
.nf
\fBsvadm\fR [\fB-C\fR \fItag\fR] \fB-e\fR {\fB-f\fR \fIconfig_file\fR | volume}
.fi

.LP
.nf
\fBsvadm\fR [\fB-C\fR \fItag\fR] \fB-d\fR {\fB-f\fR \fIconfig_file\fR | volume}
.fi

.LP
.nf
\fBsvadm\fR [\fB-C\fR \fItag\fR] \fB-r\fR {\fB-f\fR \fIconfig_file\fR | volume}
.fi

.SH DESCRIPTION
.sp
.LP
The \fBsvadm\fR command controls the Storage Volume (SV) driver by providing
facilities to enable and disable the SV driver for specified volumes, and to
dynamically reconfigure the system.
.SH OPTIONS
.sp
.LP
If you specify no arguments to an \fBsvadm\fR command, the utility displays the
list of volumes currently under SV control. \fBsvadm\fR supports the following
options:
.sp
.ne 2
.na
\fB\fB-C\fR \fItag\fR\fR
.ad
.sp .6
.RS 4n
On a clustered node, limits operations to only those volumes belonging to the
cluster resource group, or disk group name, specified by tag. This option is
illegal on a system that is not clustered. The special \fItag\fR, \fBlocal\fR,
can be used to limit operations to only those volumes that cannot switch over
to other nodes in the cluster.
.RE

.sp
.ne 2
.na
\fB\fB-d\fR\fR
.ad
.sp .6
.RS 4n
Disables the SV devices specified on the command line or in the configuration
file. If \fB-C\fR tag is specified with this option, then the volume should be
in this cluster disk group.
.RE

.sp
.ne 2
.na
\fB\fB-e\fR\fR
.ad
.sp .6
.RS 4n
Enables the SV devices specified on the command line or in the configuration
file. Details of the volume are saved in the current configuration. See
\fBdscfg\fR(1M). If \fB-C\fR tag is specified with this option, then the volume
should be in this cluster disk group.
.RE

.sp
.ne 2
.na
\fB\fB-f\fR \fIconfig_file\fR\fR
.ad
.sp .6
.RS 4n
Specifies a configuration file that contains a list of volumes. A command reads
this volume list and then perform the operation. The format of the
\fIconfig_file\fR is a simple list of volume pathnames, one per line. Blank
lines and lines starting with the comment character (#) are ignored.
.RE

.sp
.ne 2
.na
\fB\fB-h\fR\fR
.ad
.sp .6
.RS 4n
Displays the \fBsvadm\fR usage summary.
.RE

.sp
.ne 2
.na
\fB\fB-i\fR\fR
.ad
.sp .6
.RS 4n
Displays extended status for the volumes currently under SV control.
.RE

.sp
.ne 2
.na
\fB\fB-r\fR\fR
.ad
.sp .6
.RS 4n
When a \fIconfig_file\fR is specified, reconfigure the running system to match
the configuration specified in the \fIconfig_file\fR. When the \fB-C\fR option
is specified, compare the cluster tag for each volume and change it to
\fIcluster_tag\fR. If a volume is specified with this option, it is valid only
to reconfigure the cluster tag associated with the volume. The \fB-e\fR or
\fB-d\fR options should be used to enable or disable single volumes.
.RE

.sp
.ne 2
.na
\fB\fB-v\fR\fR
.ad
.sp .6
.RS 4n
Displays the SV version number.
.RE

.SH USAGE
.sp
.LP
When an SV volume is enabled, normal system call access to the device (see
\fBintro\fR(2)) is redirected into the StoreEdge architecture software. This
allows standard applications to use StorageTek features such as Sun StorageTek
Point-in-Time Copy and Remote Mirror Software.
.sp
.LP
The \fBsvadm\fR command generates an entry in the Availability Suite log file,
\fB/var/adm/ds.log\fR (see \fBds.log\fR(4)), when performing enable (\fB-e\fR)
and disable (\fB-d\fR) operations.
.SH ATTRIBUTES
.sp
.LP
See \fBattributes\fR(5) for descriptions of the following attributes:
.sp

.sp
.TS
box;
c | c
l | l .
ATTRIBUTE TYPE	ATTRIBUTE VALUE
_
Interface Stability	Evolving
.TE

.SH SEE ALSO
.sp