summaryrefslogtreecommitdiff
path: root/usr/src/tools/scripts/bfu.sh
blob: 9e9f1ff478f54c652c89a7b85d39e16bf5bfbb95 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
4243
4244
4245
4246
4247
4248
4249
4250
4251
4252
4253
4254
4255
4256
4257
4258
4259
4260
4261
4262
4263
4264
4265
4266
4267
4268
4269
4270
4271
4272
4273
4274
4275
4276
4277
4278
4279
4280
4281
4282
4283
4284
4285
4286
4287
4288
4289
4290
4291
4292
4293
4294
4295
4296
4297
4298
4299
4300
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
4317
4318
4319
4320
4321
4322
4323
4324
4325
4326
4327
4328
4329
4330
4331
4332
4333
4334
4335
4336
4337
4338
4339
4340
4341
4342
4343
4344
4345
4346
4347
4348
4349
4350
4351
4352
4353
4354
4355
4356
4357
4358
4359
4360
4361
4362
4363
4364
4365
4366
4367
4368
4369
4370
4371
4372
4373
4374
4375
4376
4377
4378
4379
4380
4381
4382
4383
4384
4385
4386
4387
4388
4389
4390
4391
4392
4393
4394
4395
4396
4397
4398
4399
4400
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4417
4418
4419
4420
4421
4422
4423
4424
4425
4426
4427
4428
4429
4430
4431
4432
4433
4434
4435
4436
4437
4438
4439
4440
4441
4442
4443
4444
4445
4446
4447
4448
4449
4450
4451
4452
4453
4454
4455
4456
4457
4458
4459
4460
4461
4462
4463
4464
4465
4466
4467
4468
4469
4470
4471
4472
4473
4474
4475
4476
4477
4478
4479
4480
4481
4482
4483
4484
4485
4486
4487
4488
4489
4490
4491
4492
4493
4494
4495
4496
4497
4498
4499
4500
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4517
4518
4519
4520
4521
4522
4523
4524
4525
4526
4527
4528
4529
4530
4531
4532
4533
4534
4535
4536
4537
4538
4539
4540
4541
4542
4543
4544
4545
4546
4547
4548
4549
4550
4551
4552
4553
4554
4555
4556
4557
4558
4559
4560
4561
4562
4563
4564
4565
4566
4567
4568
4569
4570
4571
4572
4573
4574
4575
4576
4577
4578
4579
4580
4581
4582
4583
4584
4585
4586
4587
4588
4589
4590
4591
4592
4593
4594
4595
4596
4597
4598
4599
4600
4601
4602
4603
4604
4605
4606
4607
4608
4609
4610
4611
4612
4613
4614
4615
4616
4617
4618
4619
4620
4621
4622
4623
4624
4625
4626
4627
4628
4629
4630
4631
4632
4633
4634
4635
4636
4637
4638
4639
4640
4641
4642
4643
4644
4645
4646
4647
4648
4649
4650
4651
4652
4653
4654
4655
4656
4657
4658
4659
4660
4661
4662
4663
4664
4665
4666
4667
4668
4669
4670
4671
4672
4673
4674
4675
4676
4677
4678
4679
4680
4681
4682
4683
4684
4685
4686
4687
4688
4689
4690
4691
4692
4693
4694
4695
4696
4697
4698
4699
4700
4701
4702
4703
4704
4705
4706
4707
4708
4709
4710
4711
4712
4713
4714
4715
4716
4717
4718
4719
4720
4721
4722
4723
4724
4725
4726
4727
4728
4729
4730
4731
4732
4733
4734
4735
4736
4737
4738
4739
4740
4741
4742
4743
4744
4745
4746
4747
4748
4749
4750
4751
4752
4753
4754
4755
4756
4757
4758
4759
4760
4761
4762
4763
4764
4765
4766
4767
4768
4769
4770
4771
4772
4773
4774
4775
4776
4777
4778
4779
4780
4781
4782
4783
4784
4785
4786
4787
4788
4789
4790
4791
4792
4793
4794
4795
4796
4797
4798
4799
4800
4801
4802
4803
4804
4805
4806
4807
4808
4809
4810
4811
4812
4813
4814
4815
4816
4817
4818
4819
4820
4821
4822
4823
4824
4825
4826
4827
4828
4829
4830
4831
4832
4833
4834
4835
4836
4837
4838
4839
4840
4841
4842
4843
4844
4845
4846
4847
4848
4849
4850
4851
4852
4853
4854
4855
4856
4857
4858
4859
4860
4861
4862
4863
4864
4865
4866
4867
4868
4869
4870
4871
4872
4873
4874
4875
4876
4877
4878
4879
4880
4881
4882
4883
4884
4885
4886
4887
4888
4889
4890
4891
4892
4893
4894
4895
4896
4897
4898
4899
4900
4901
4902
4903
4904
4905
4906
4907
4908
4909
4910
4911
4912
4913
4914
4915
4916
4917
4918
4919
4920
4921
4922
4923
4924
4925
4926
4927
4928
4929
4930
4931
4932
4933
4934
4935
4936
4937
4938
4939
4940
4941
4942
4943
4944
4945
4946
4947
4948
4949
4950
4951
4952
4953
4954
4955
4956
4957
4958
4959
4960
4961
4962
4963
4964
4965
4966
4967
4968
4969
4970
4971
4972
4973
4974
4975
4976
4977
4978
4979
4980
4981
4982
4983
4984
4985
4986
4987
4988
4989
4990
4991
4992
4993
4994
4995
4996
4997
4998
4999
5000
5001
5002
5003
5004
5005
5006
5007
5008
5009
5010
5011
5012
5013
5014
5015
5016
5017
5018
5019
5020
5021
5022
5023
5024
5025
5026
5027
5028
5029
5030
5031
5032
5033
5034
5035
5036
5037
5038
5039
5040
5041
5042
5043
5044
5045
5046
5047
5048
5049
5050
5051
5052
5053
5054
5055
5056
5057
5058
5059
5060
5061
5062
5063
5064
5065
5066
5067
5068
5069
5070
5071
5072
5073
5074
5075
5076
5077
5078
5079
5080
5081
5082
5083
5084
5085
5086
5087
5088
5089
5090
5091
5092
5093
5094
5095
5096
5097
5098
5099
5100
5101
5102
5103
5104
5105
5106
5107
5108
5109
5110
5111
5112
5113
5114
5115
5116
5117
5118
5119
5120
5121
5122
5123
5124
5125
5126
5127
5128
5129
5130
5131
5132
5133
5134
5135
5136
5137
5138
5139
5140
5141
5142
5143
5144
5145
5146
5147
5148
5149
5150
5151
5152
5153
5154
5155
5156
5157
5158
5159
5160
5161
5162
5163
5164
5165
5166
5167
5168
5169
5170
5171
5172
5173
5174
5175
5176
5177
5178
5179
5180
5181
5182
5183
5184
5185
5186
5187
5188
5189
5190
5191
5192
5193
5194
5195
5196
5197
5198
5199
5200
5201
5202
5203
5204
5205
5206
5207
5208
5209
5210
5211
5212
5213
5214
5215
5216
5217
5218
5219
5220
5221
5222
5223
5224
5225
5226
5227
5228
5229
5230
5231
5232
5233
5234
5235
5236
5237
5238
5239
5240
5241
5242
5243
5244
5245
5246
5247
5248
5249
5250
5251
5252
5253
5254
5255
5256
5257
5258
5259
5260
5261
5262
5263
5264
5265
5266
5267
5268
5269
5270
5271
5272
5273
5274
5275
5276
5277
5278
5279
5280
5281
5282
5283
5284
5285
5286
5287
5288
5289
5290
5291
5292
5293
5294
5295
5296
5297
5298
5299
5300
5301
5302
5303
5304
5305
5306
5307
5308
5309
5310
5311
5312
5313
5314
5315
5316
5317
5318
5319
5320
5321
5322
5323
5324
5325
5326
5327
5328
5329
5330
5331
5332
5333
5334
5335
5336
5337
5338
5339
5340
5341
5342
5343
5344
5345
5346
5347
5348
5349
5350
5351
5352
5353
5354
5355
5356
5357
5358
5359
5360
5361
5362
5363
5364
5365
5366
5367
5368
5369
5370
5371
5372
5373
5374
5375
5376
5377
5378
5379
5380
5381
5382
5383
5384
5385
5386
5387
5388
5389
5390
5391
5392
5393
5394
5395
5396
5397
5398
5399
5400
5401
5402
5403
5404
5405
5406
5407
5408
5409
5410
5411
5412
5413
5414
5415
5416
5417
5418
5419
5420
5421
5422
5423
5424
5425
5426
5427
5428
5429
5430
5431
5432
5433
5434
5435
5436
5437
5438
5439
5440
5441
5442
5443
5444
5445
5446
5447
5448
5449
5450
5451
5452
5453
5454
5455
5456
5457
5458
5459
5460
5461
5462
5463
5464
5465
5466
5467
5468
5469
5470
5471
5472
5473
5474
5475
5476
5477
5478
5479
5480
5481
5482
5483
5484
5485
5486
5487
5488
5489
5490
5491
5492
5493
5494
5495
5496
5497
5498
5499
5500
5501
5502
5503
5504
5505
5506
5507
5508
5509
5510
5511
5512
5513
5514
5515
5516
5517
5518
5519
5520
5521
5522
5523
5524
5525
5526
5527
5528
5529
5530
5531
5532
5533
5534
5535
5536
5537
5538
5539
5540
5541
5542
5543
5544
5545
5546
5547
5548
5549
5550
5551
5552
5553
5554
5555
5556
5557
5558
5559
5560
5561
5562
5563
5564
5565
5566
5567
5568
5569
5570
5571
5572
5573
5574
5575
5576
5577
5578
5579
5580
5581
5582
5583
5584
5585
5586
5587
5588
5589
5590
5591
5592
5593
5594
5595
5596
5597
5598
5599
5600
5601
5602
5603
5604
5605
5606
5607
5608
5609
5610
5611
5612
5613
5614
5615
5616
5617
5618
5619
5620
5621
5622
5623
5624
5625
5626
5627
5628
5629
5630
5631
5632
5633
5634
5635
5636
5637
5638
5639
5640
5641
5642
5643
5644
5645
5646
5647
5648
5649
5650
5651
5652
5653
5654
5655
5656
5657
5658
5659
5660
5661
5662
5663
5664
5665
5666
5667
5668
5669
5670
5671
5672
5673
5674
5675
5676
5677
5678
5679
5680
5681
5682
5683
5684
5685
5686
5687
5688
5689
5690
5691
5692
5693
5694
5695
5696
5697
5698
5699
5700
5701
5702
5703
5704
5705
5706
5707
5708
5709
5710
5711
5712
5713
5714
5715
5716
5717
5718
5719
5720
5721
5722
5723
5724
5725
5726
5727
5728
5729
5730
5731
5732
5733
5734
5735
5736
5737
5738
5739
5740
5741
5742
5743
5744
5745
5746
5747
5748
5749
5750
5751
5752
5753
5754
5755
5756
5757
5758
5759
5760
5761
5762
5763
5764
5765
5766
5767
5768
5769
5770
5771
5772
5773
5774
5775
5776
5777
5778
5779
5780
5781
5782
5783
5784
5785
5786
5787
5788
5789
5790
5791
5792
5793
5794
5795
5796
5797
5798
5799
5800
5801
5802
5803
5804
5805
5806
5807
5808
5809
5810
5811
5812
5813
5814
5815
5816
5817
5818
5819
5820
5821
5822
5823
5824
5825
5826
5827
5828
5829
5830
5831
5832
5833
5834
5835
5836
5837
5838
5839
5840
5841
5842
5843
5844
5845
5846
5847
5848
5849
5850
5851
5852
5853
5854
5855
5856
5857
5858
5859
5860
5861
5862
5863
5864
5865
5866
5867
5868
5869
5870
5871
5872
5873
5874
5875
5876
5877
5878
5879
5880
5881
5882
5883
5884
5885
5886
5887
5888
5889
5890
5891
5892
5893
5894
5895
5896
5897
5898
5899
5900
5901
5902
5903
5904
5905
5906
5907
5908
5909
5910
5911
5912
5913
5914
5915
5916
5917
5918
5919
5920
5921
5922
5923
5924
5925
5926
5927
5928
5929
5930
5931
5932
5933
5934
5935
5936
5937
5938
5939
5940
5941
5942
5943
5944
5945
5946
5947
5948
5949
5950
5951
5952
5953
5954
5955
5956
5957
5958
5959
5960
5961
5962
5963
5964
5965
5966
5967
5968
5969
5970
5971
5972
5973
5974
5975
5976
5977
5978
5979
5980
5981
5982
5983
5984
5985
5986
5987
5988
5989
5990
5991
5992
5993
5994
5995
5996
5997
5998
5999
6000
6001
6002
6003
6004
6005
6006
6007
6008
6009
6010
6011
6012
6013
6014
6015
6016
6017
6018
6019
6020
6021
6022
6023
6024
6025
6026
6027
6028
6029
6030
6031
6032
6033
6034
6035
6036
6037
6038
6039
6040
6041
6042
6043
6044
6045
6046
6047
6048
6049
6050
6051
6052
6053
6054
6055
6056
6057
6058
6059
6060
6061
6062
6063
6064
6065
6066
6067
6068
6069
6070
6071
6072
6073
6074
6075
6076
6077
6078
6079
6080
6081
6082
6083
6084
6085
6086
6087
6088
6089
6090
6091
6092
6093
6094
6095
6096
6097
6098
6099
6100
6101
6102
6103
6104
6105
6106
6107
6108
6109
6110
6111
6112
6113
6114
6115
6116
6117
6118
6119
6120
6121
6122
6123
6124
6125
6126
6127
6128
6129
6130
6131
6132
6133
6134
6135
6136
6137
6138
6139
6140
6141
6142
6143
6144
6145
6146
6147
6148
6149
6150
6151
6152
6153
6154
6155
6156
6157
6158
6159
6160
6161
6162
6163
6164
6165
6166
6167
6168
6169
6170
6171
6172
6173
6174
6175
6176
6177
6178
6179
6180
6181
6182
6183
6184
6185
6186
6187
6188
6189
6190
6191
6192
6193
6194
6195
6196
6197
6198
6199
6200
6201
6202
6203
6204
6205
6206
6207
6208
6209
6210
6211
6212
6213
6214
6215
6216
6217
6218
6219
6220
6221
6222
6223
6224
6225
6226
6227
6228
6229
6230
6231
6232
6233
6234
6235
6236
6237
6238
6239
6240
6241
6242
6243
6244
6245
6246
6247
6248
6249
6250
6251
6252
6253
6254
6255
6256
6257
6258
6259
6260
6261
6262
6263
6264
6265
6266
6267
6268
6269
6270
6271
6272
6273
6274
6275
6276
6277
6278
6279
6280
6281
6282
6283
6284
6285
6286
6287
6288
6289
6290
6291
6292
6293
6294
6295
6296
6297
6298
6299
6300
6301
6302
6303
6304
6305
6306
6307
6308
6309
6310
6311
6312
6313
6314
6315
6316
6317
6318
6319
6320
6321
6322
6323
6324
6325
6326
6327
6328
6329
6330
6331
6332
6333
6334
6335
6336
6337
6338
6339
6340
6341
6342
6343
6344
6345
6346
6347
6348
6349
6350
6351
6352
6353
6354
6355
6356
6357
6358
6359
6360
6361
6362
6363
6364
6365
6366
6367
6368
6369
6370
6371
6372
6373
6374
6375
6376
6377
6378
6379
6380
6381
6382
6383
6384
6385
6386
6387
6388
6389
6390
6391
6392
6393
6394
6395
6396
6397
6398
6399
6400
6401
6402
6403
6404
6405
6406
6407
6408
6409
6410
6411
6412
6413
6414
6415
6416
6417
6418
6419
6420
6421
6422
6423
6424
6425
6426
6427
6428
6429
6430
6431
6432
6433
6434
6435
6436
6437
6438
6439
6440
6441
6442
6443
6444
6445
6446
6447
6448
6449
6450
6451
6452
6453
6454
6455
6456
6457
6458
6459
6460
6461
6462
6463
6464
6465
6466
6467
6468
6469
6470
6471
6472
6473
6474
6475
6476
6477
6478
6479
6480
6481
6482
6483
6484
6485
6486
6487
6488
6489
6490
6491
6492
6493
6494
6495
6496
6497
6498
6499
6500
6501
6502
6503
6504
6505
6506
6507
6508
6509
6510
6511
6512
6513
6514
6515
6516
6517
6518
6519
6520
6521
6522
6523
6524
6525
6526
6527
6528
6529
6530
6531
6532
6533
6534
6535
6536
6537
6538
6539
6540
6541
6542
6543
6544
6545
6546
6547
6548
6549
6550
6551
6552
6553
6554
6555
6556
6557
6558
6559
6560
6561
6562
6563
6564
6565
6566
6567
6568
6569
6570
6571
6572
6573
6574
6575
6576
6577
6578
6579
6580
6581
6582
6583
6584
6585
6586
6587
6588
6589
6590
6591
6592
6593
6594
6595
6596
6597
6598
6599
6600
6601
6602
6603
6604
6605
6606
6607
6608
6609
6610
6611
6612
6613
6614
6615
6616
6617
6618
6619
6620
6621
6622
6623
6624
6625
6626
6627
6628
6629
6630
6631
6632
6633
6634
6635
6636
6637
6638
6639
6640
6641
6642
6643
6644
6645
6646
6647
6648
6649
6650
6651
6652
6653
6654
6655
6656
6657
6658
6659
6660
6661
6662
6663
6664
6665
6666
6667
6668
6669
6670
6671
6672
6673
6674
6675
6676
6677
6678
6679
6680
6681
6682
6683
6684
6685
6686
6687
6688
6689
6690
6691
6692
6693
6694
6695
6696
6697
6698
6699
6700
6701
6702
6703
6704
6705
6706
6707
6708
6709
6710
6711
6712
6713
6714
6715
6716
6717
6718
6719
6720
6721
6722
6723
6724
6725
6726
6727
6728
6729
6730
6731
6732
6733
6734
6735
6736
6737
6738
6739
6740
6741
6742
6743
6744
6745
6746
6747
6748
6749
6750
6751
6752
6753
6754
6755
6756
6757
6758
6759
6760
6761
6762
6763
6764
6765
6766
6767
6768
6769
6770
6771
6772
6773
6774
6775
6776
6777
6778
6779
6780
6781
6782
6783
6784
6785
6786
6787
6788
6789
6790
6791
6792
6793
6794
6795
6796
6797
6798
6799
6800
6801
6802
6803
6804
6805
6806
6807
6808
6809
6810
6811
6812
6813
6814
6815
6816
6817
6818
6819
6820
6821
6822
6823
6824
6825
6826
6827
6828
6829
6830
6831
6832
6833
6834
6835
6836
6837
6838
6839
6840
6841
6842
6843
6844
6845
6846
6847
6848
6849
6850
6851
6852
6853
6854
6855
6856
6857
6858
6859
6860
6861
6862
6863
6864
6865
6866
6867
6868
6869
6870
6871
6872
6873
6874
6875
6876
6877
6878
6879
6880
6881
6882
6883
6884
6885
6886
6887
6888
6889
6890
6891
6892
6893
6894
6895
6896
6897
6898
6899
6900
6901
6902
6903
6904
6905
6906
6907
6908
6909
6910
6911
6912
6913
6914
6915
6916
6917
6918
6919
6920
6921
6922
6923
6924
6925
6926
6927
6928
6929
6930
6931
6932
6933
6934
6935
6936
6937
6938
6939
6940
6941
6942
6943
6944
6945
6946
6947
6948
6949
6950
6951
6952
6953
6954
6955
6956
6957
6958
6959
6960
6961
6962
6963
6964
6965
6966
6967
6968
6969
6970
6971
6972
6973
6974
6975
6976
6977
6978
6979
6980
6981
6982
6983
6984
6985
6986
6987
6988
6989
6990
6991
6992
6993
6994
6995
6996
6997
6998
6999
7000
7001
7002
7003
7004
7005
7006
7007
7008
7009
7010
7011
7012
7013
7014
7015
7016
7017
7018
7019
7020
7021
7022
7023
7024
7025
7026
7027
7028
7029
7030
7031
7032
7033
7034
7035
7036
7037
7038
7039
7040
7041
7042
7043
7044
7045
7046
7047
7048
7049
7050
7051
7052
7053
7054
7055
7056
7057
7058
7059
7060
7061
7062
7063
7064
7065
7066
7067
7068
7069
7070
7071
7072
7073
7074
7075
7076
7077
7078
7079
7080
7081
7082
7083
7084
7085
7086
7087
7088
7089
7090
7091
7092
7093
7094
7095
7096
7097
7098
7099
7100
7101
7102
7103
7104
7105
7106
7107
7108
7109
7110
7111
7112
7113
7114
7115
7116
7117
7118
7119
7120
7121
7122
7123
7124
7125
7126
7127
7128
7129
7130
7131
7132
7133
7134
7135
7136
7137
7138
7139
7140
7141
7142
7143
7144
7145
7146
7147
7148
7149
7150
7151
7152
7153
7154
7155
7156
7157
7158
7159
7160
7161
7162
7163
7164
7165
7166
7167
7168
7169
7170
7171
7172
7173
7174
7175
7176
7177
7178
7179
7180
7181
7182
7183
7184
7185
7186
7187
7188
7189
7190
7191
7192
7193
7194
7195
7196
7197
7198
7199
7200
7201
7202
7203
7204
7205
7206
7207
7208
7209
7210
7211
7212
7213
7214
7215
7216
7217
7218
7219
7220
7221
7222
7223
7224
7225
7226
7227
7228
7229
7230
7231
7232
7233
7234
7235
7236
7237
7238
7239
7240
7241
7242
7243
7244
7245
7246
7247
7248
7249
7250
7251
7252
7253
7254
7255
7256
7257
7258
7259
7260
7261
7262
7263
7264
7265
7266
7267
7268
7269
7270
7271
7272
7273
7274
7275
7276
7277
7278
7279
7280
7281
7282
7283
7284
7285
7286
7287
7288
7289
7290
7291
7292
7293
7294
7295
7296
7297
7298
7299
7300
7301
7302
7303
7304
7305
7306
7307
7308
7309
7310
7311
7312
7313
7314
7315
7316
7317
7318
7319
7320
7321
7322
7323
7324
7325
7326
7327
7328
7329
7330
7331
7332
7333
7334
7335
7336
7337
7338
7339
7340
7341
7342
7343
7344
7345
7346
7347
7348
7349
7350
7351
7352
7353
7354
7355
7356
7357
7358
7359
7360
7361
7362
7363
7364
7365
7366
7367
7368
7369
7370
7371
7372
7373
7374
7375
7376
7377
7378
7379
7380
7381
7382
7383
7384
7385
7386
7387
7388
7389
7390
7391
7392
7393
7394
7395
7396
7397
7398
7399
7400
7401
7402
7403
7404
7405
7406
7407
7408
7409
7410
7411
7412
7413
7414
7415
7416
7417
7418
7419
7420
7421
7422
7423
7424
7425
7426
7427
7428
7429
7430
7431
7432
7433
7434
7435
7436
7437
7438
7439
7440
7441
7442
7443
7444
7445
7446
7447
7448
7449
7450
7451
7452
7453
7454
7455
7456
7457
7458
7459
7460
7461
7462
7463
7464
7465
7466
7467
7468
7469
7470
7471
7472
7473
7474
7475
7476
7477
7478
7479
7480
7481
7482
7483
7484
7485
7486
7487
7488
#!/bin/ksh
#
# CDDL HEADER START
#
# The contents of this file are subject to the terms of the
# Common Development and Distribution License (the "License").
# You may not use this file except in compliance with the License.
#
# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
# or http://www.opensolaris.org/os/licensing.
# See the License for the specific language governing permissions
# and limitations under the License.
#
# When distributing Covered Code, include this CDDL HEADER in each
# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
# If applicable, add the following below this CDDL HEADER, with the
# fields enclosed by brackets "[]" replaced with your own identifying
# information: Portions Copyright [yyyy] [name of copyright owner]
#
# CDDL HEADER END
#

#
# Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
# Use is subject to license terms.
#
# ident	"%Z%%M%	%I%	%E% SMI"
#
# Upgrade a machine from a cpio archive area in about 5 minutes.
# By Roger Faulkner and Jeff Bonwick, April 1993.
# (bfu == Bonwick/Faulkner Upgrade, a.k.a. Blindingly Fast Upgrade)
#
# Usage: bfu    [-f] <archive_dir> [root-dir]	# for normal machines
#        bfu -c [-f] <archive_dir> <exec-dir>	# for diskless clients
#
# The -f flag is to override the built-in safety check which requires
# that the starting-point OS be a least a certain revision.
#
# You have to be super-user.  It's safest to run this from the
# system console, although I've run it under OW and even via
# remote login with no problems.
#
# You will have to reboot the system when the upgrade is complete.
#
# You should add any administrative files you care about to this list.
# Warning: there had better be no leading '/' on any of these filenames.

#
# The CDPATH variable causes ksh's `cd' builtin to emit messages to stdout
# under certain circumstances, which can really screw things up; unset it.
#
unset CDPATH

export LC_ALL="C"

if [ -z "$GATEPATH" ]; then
	GATEPATH=/ws/onnv-gate
	test -d $GATEPATH || GATEPATH=/net/onnv.eng/export/gate
fi
if [ -z "$ARCHIVEPATH" ]; then
	ARCHIVEPATH=/ws/onnv-gate
	test -d $ARCHIVEPATH || ARCHIVEPATH=/net/onnv.eng/export
fi
export GATE=${GATEPATH}
export ARCHIVE=${ARCHIVEPATH}

#
# NOTE:	Entries in *_files must expand to either the exact files required,
#	or to directories that will be scoured for files.  Any directories
#	(and subdirectories) resulting from a wildcard expansion will be
#	fully recursed by BFU's searching for files.  (E.g. /etc/inet/* will
#	include all files in any of its directories, as well as any files in
#	/etc/inet/ itself.
#
#	These lists should really be generated automatically from the
#	pkgmap(4) metadata.
#

#
# First list: files to be saved in global and non-global zones.
#
all_zones_files="
	etc/.login
	etc/acct/holidays
	etc/acctadm.conf
	etc/auto_*
	etc/cron.d/at.deny
	etc/cron.d/cron.deny
	etc/crypto/pkcs11.conf
	etc/default/*
	etc/dev/reserved_devnames
	etc/dfs/dfstab
	etc/dumpdates
	etc/ftpd/*
	etc/ftpusers
	etc/group
	etc/gss/gsscred.conf
	etc/gss/mech
	etc/gss/qop
	etc/inet/*
	etc/init.d/*
	etc/inittab
	etc/ipf/ipf.conf
	etc/iu.ap
	etc/krb5/kadm5.acl
	etc/krb5/kdc.conf
	etc/krb5/kpropd.acl
	etc/krb5/krb5.conf
	etc/krb5/warn.conf
	etc/ksh.kshrc
	etc/logadm.conf
	etc/logindevperm
	etc/lp/Systems
	etc/mail/*.cf
	etc/mail/*.hf
	etc/mail/*.rc
	etc/mail/aliases
	etc/mail/helpfile
	etc/mail/local-host-names
	etc/mail/trusted-users
	etc/named.conf
	etc/net/*/services
	etc/netconfig
	etc/nfs/nfslog.conf
	etc/nfssec.conf
	etc/nscd.conf
	etc/nsswitch.*
	etc/pam.conf
	etc/passwd
	etc/policy.conf
	etc/printers.conf
	etc/profile
	etc/project
	etc/publickey
	etc/remote
	etc/resolv.conf
	etc/rmmount.conf
	etc/rpc
	etc/rpld.conf
	etc/saf/_sactab
	etc/saf/_sysconfig
	etc/saf/zsmon/_pmtab
	etc/security/audit_class
	etc/security/audit_control
	etc/security/audit_event
	etc/security/audit_startup
	etc/security/audit_user
	etc/security/audit_warn
	etc/security/auth_attr
	etc/security/crypt.conf
	etc/security/exec_attr
	etc/security/policy.conf
	etc/security/prof_attr
	etc/sfw/openssl/openssl.cnf
	etc/shadow
	etc/skel/.profile
	etc/skel/local.*
	etc/smartcard/.keys
	etc/smartcard/desktop.properties
	etc/smartcard/ocf.classpath
	etc/smartcard/opencard.properties
	etc/ssh/ssh_config
	etc/ssh/sshd_config
	etc/syslog.conf
	etc/ttydefs
	etc/ttysrch
	etc/user_attr
	etc/uucp/[A-Z]*
	etc/vfstab
	var/spool/cron/crontabs/*
	var/yp/Makefile
	var/yp/aliases
	var/yp/nicknames
"

#
# Second list: files to be saved in the global zone only.
#
global_zone_only_files="
	boot/grub/menu.lst
	boot/solaris/bootenv.rc
	boot/solaris/devicedb/master
	boot/solaris/filelist.ramdisk
	etc/aggregation.conf
	etc/dladm/*
	etc/bootrc
	etc/crypto/kcf.conf
	etc/datalink.conf
	etc/devlink.tab
	etc/driver_aliases
	etc/driver_classes
	etc/lvm/devpath
	etc/lvm/lock
	etc/lvm/md.cf
	etc/lvm/md.ctlrmap
	etc/lvm/md.tab
	etc/lvm/mddb.cf
	etc/lvm/runtime.cf
	etc/mach
	etc/minor_perm
	etc/name_to_major
	etc/name_to_sysnum
	etc/nca/nca.if
	etc/nca/ncakmod.conf
	etc/nca/ncalogd.conf
	etc/nca/ncaport.conf
	etc/openwin/server/etc/OWconfig
	etc/path_to_inst
	etc/power.conf
	etc/ppp/chap-secrets
	etc/ppp/options
	etc/ppp/pap-secrets
	etc/security/device_policy
	etc/security/extra_privs
	etc/security/tsol/tnrhdb
	etc/security/tsol/tnrhtp
	etc/security/tsol/tnzonecfg
	etc/security/tsol/label_encodings
	etc/security/tsol/relabel
	etc/security/tsol/devalloc_defaults
	etc/system
	etc/zones/index
	kernel/drv/elxl.conf
	kernel/drv/md.conf
	kernel/drv/options.conf
	kernel/drv/ra.conf
	kernel/drv/scsa2usb.conf
	kernel/drv/scsi_vhci.conf
	kernel/drv/sd.conf
	kernel/drv/mpt.conf
	platform/*/kernel/drv/*ppm.conf
	platform/i86pc/kernel/drv/aha.conf
	platform/i86pc/kernel/drv/asy.conf
	platform/sun4u/boot.conf
"

#
# Third list: files extracted from generic.root but which belong in the global
# zone only: they are superfluous (and some even harmful) in nonglobal zones.
#
# (note: as /etc/init.d scripts are converted to smf(5) "Greenline" services,
# they (and their /etc/rc?.d hardlinks) should be removed from this list when
# they are added to smf_obsolete_rc_files, below)
#
superfluous_nonglobal_zone_files="
	dev/dsk
	dev/fd
	dev/pts
	dev/rdsk
	dev/rmt
	dev/stderr
	dev/stdin
	dev/stdout
	dev/swap
	dev/term
	devices
	etc/dacf.conf
	etc/dat
	etc/default/metassist.xml
	etc/default/power
	etc/flash/postdeployment/svm.cleanup
	etc/flash/predeployment/svm.save
	etc/inet/ipqosconf.1.sample
	etc/inet/ipqosconf.2.sample
	etc/inet/ipqosconf.3.sample
	etc/inet/sock2path
	etc/init.d/devlinks
	etc/init.d/dodatadm.udaplt
	etc/init.d/drvconfig
	etc/init.d/llc2
	etc/init.d/ncakmod
	etc/init.d/ncalogd
	etc/init.d/pcmcia
	etc/init.d/pppd
	etc/init.d/wrsmcfg
	etc/llc2
	etc/lvm
	etc/nca
	etc/openwin
	etc/ppp
	etc/rc0.d/K34ncalogd
	etc/rc0.d/K50pppd
	etc/rc0.d/K52llc2
	etc/rc1.d/K34ncalogd
	etc/rc1.d/K50pppd
	etc/rc1.d/K52llc2
	etc/rc2.d/S40llc2
	etc/rc2.d/S42ncakmod
	etc/rc2.d/S47pppd
	etc/rc2.d/S81dodatadm.udaplt
	etc/rc2.d/S94ncalogd
	etc/rcS.d/K34ncalogd
	etc/rcS.d/K44wrsmcfg
	etc/rcS.d/K50pppd
	etc/rcS.d/K52llc2
	etc/rcS.d/S29wrsmcfg
	etc/rcm
	etc/sock2path
	etc/usb
	etc/wrsm
	etc/zones
	kernel
	lib/libmeta.so
	lib/libmeta.so.1
	lib/svc/method/sf880dr
	lib/svc/method/svc-cvcd
	lib/svc/method/svc-dcs
	lib/svc/method/svc-drd
	lib/svc/method/svc-dscp
	lib/svc/method/svc-dumpadm
	lib/svc/method/svc-intrd
	lib/svc/method/svc-hal
	lib/svc/method/svc-labeld
	lib/svc/method/svc-mdmonitor
	lib/svc/method/svc-metainit
	lib/svc/method/svc-metasync
	lib/svc/method/svc-oplhpd
	lib/svc/method/svc-poold
	lib/svc/method/svc-pools
	lib/svc/method/svc-power
	lib/svc/method/svc-resource-mgmt
	lib/svc/method/svc-rmvolmgr
	lib/svc/method/svc-scheduler
	lib/svc/method/svc-sckmd
	lib/svc/method/svc-syseventd
	lib/svc/method/svc-tnctl
	lib/svc/method/svc-tnd
	lib/svc/method/svc-vntsd
	lib/svc/method/svc-zones
	platform/*/kernel
	platform/SUNW,Sun-Fire-15000/lib/cvcd
	platform/SUNW,Ultra-Enterprise-10000/lib/cvcd
	platform/i86pc/biosint
	platform/i86pc/multiboot
	platform/sun4u/cprboot
	platform/sun4u/lib/libwrsmconf.so
	platform/sun4u/lib/libwrsmconf.so.1
	platform/sun4u/lib/sparcv9/libwrsmconf.so
	platform/sun4u/lib/sparcv9/libwrsmconf.so.1
	platform/sun4u/sbin
	platform/sun4u/ufsboot
	platform/sun4u/wanboot
	platform/sun4v/ufsboot
	platform/sun4v/wanboot
	sbin/metadb
	sbin/metadevadm
	sbin/metainit
	sbin/metarecover
	sbin/metastat
	usr/include/sys/dcam
	usr/lib/devfsadm/linkmod/SUNW_dcam1394_link.so
	usr/lib/ldoms
	usr/platform/SUNW,SPARC-Enterprise/lib/dscp.ppp.options
	usr/platform/SUNW,SPARC-Enterprise/lib/libdscp.so
	usr/platform/SUNW,SPARC-Enterprise/lib/libdscp.so.1
	usr/platform/SUNW,SPARC-Enterprise/lib/llib-ldscp.ln
	usr/platform/SUNW,SPARC-Enterprise/sbin/prtdscp
	var/adm/pool
	var/log/pool
	var/svc/manifest/network/rpc/mdcomm.xml
	var/svc/manifest/network/rpc/meta.xml
	var/svc/manifest/network/rpc/metamed.xml
	var/svc/manifest/network/rpc/metamh.xml
	var/svc/manifest/network/tnctl.xml
	var/svc/manifest/network/tnd.xml
	var/svc/manifest/platform/i86pc/eeprom.xml
	var/svc/manifest/platform/sun4u/dcs.xml
	var/svc/manifest/platform/sun4u/dscp.xml
	var/svc/manifest/platform/sun4u/efdaemon.xml
	var/svc/manifest/platform/sun4u/oplhpd.xml
	var/svc/manifest/platform/sun4u/sckmd.xml
	var/svc/manifest/platform/sun4u/sf880drd.xml
	var/svc/manifest/platform/sun4v
	var/svc/manifest/system/cvc.xml
	var/svc/manifest/system/dumpadm.xml
	var/svc/manifest/system/fmd.xml
	var/svc/manifest/system/hal.xml
	var/svc/manifest/system/intrd.xml
	var/svc/manifest/system/labeld.xml
	var/svc/manifest/system/mdmonitor.xml
	var/svc/manifest/system/metainit.xml
	var/svc/manifest/system/metasync.xml
	var/svc/manifest/system/picl.xml
	var/svc/manifest/system/poold.xml
	var/svc/manifest/system/pools.xml
	var/svc/manifest/system/power.xml
	var/svc/manifest/system/resource-mgmt.xml
	var/svc/manifest/system/scheduler.xml
	var/svc/manifest/system/sysevent.xml
	var/svc/manifest/system/zones.xml
	var/svc/manifest/system/filesystem/rmvolmgr.xml
"

#
# Fourth list: files to be preserved, ie unconditionally restored to
# "child" versions
#
preserve_files="
	kernel/misc/amd64/sysinit
	kernel/misc/amd64/usbs49_fw
	kernel/misc/sparcv9/usbs49_fw
	kernel/misc/sysinit
	kernel/misc/usbs49_fw
	var/adm/aculog
	var/adm/spellhist
	var/adm/utmpx
	var/adm/wtmpx
	var/log/authlog
	var/log/syslog
	var/saf/zsmon/log
"

realmode_files="
	boot/solaris/bootenv.rc
	boot/solaris/devicedb/master
"

fail() {
	print "$*" >& 2
	print "bfu aborting" >& 2
	rm -f "$bfu_zone_list"
	exit 1
}

filelist() {
	files="$all_zones_files $preserve_files"
	if [ $1 = "global" ]; then
		files="$global_zone_only_files $files"
	fi
	find $files -depth -type f ! -name core -print 2>/dev/null | sort -u || {
		#
		# Force cpio to return non-zero by printing an error message
		# to stdout that it won't be able to lstat().
		#
		echo 'filelist: sort failed'
		fail "sort failed"
	}
}

realmode_filelist() {
	find $realmode_files -depth -type f ! -name core -print 2>/dev/null | sort
}

smf_inetd_conversions="
	100134
	100150
	100155
	100229
	100230
	100234
	100242
	100422
	chargen
	comsat
	daytime
	discard
	echo
	eklogin
	exec
	finger
	ftp
	gssd
	klogin
	krb5_prop
	kshell
	ktkt_warnd
	login
	metad
	metamedd
	metamhd
	name
	ocfserv
	printer
	rexd
	rquotad
	rstatd
	rusersd
	shell
	smserverd
	sprayd
	sun-dr
	talk
	telnet
	time
	uucp
	walld
"

enable_next_boot () {
	if [ -x /tmp/bfubin/svccfg ]; then
	    svcadm disable -t $1
	    [ $? = 0 ] || echo "warning: unable to temporarily disable $1"
	    svccfg -s $1 setprop general/enabled = true
	    [ $? = 0 ] || echo "warning: unable to enable $1 for next boot"
	fi
}

smf_inetd_disable() {
	inetconf=$rootprefix/etc/inet/inetd.conf
	inettmp=/tmp/inetd.tmp.$$

	sed "$(for i in $smf_inetd_conversions; do 
		echo "s:^[ 	]*$i[ 	/]:#SMFbfu# &:"
	done)" $inetconf > $inettmp && ! cmp -s $inettmp $inetconf &&
	    cp $inettmp $inetconf

	rm -f -- $inettmp
}

smf_inetd_reenable() {
	inetconf=$rootprefix/etc/inet/inetd.conf
	inettmp=/tmp/inetd.tmp.$$

	sed 's/^#SMFbfu# //' $inetconf > $inettmp && cp $inettmp $inetconf

	rm -f -- $inettmp
}

smf_tftp_reinstall() {
	inetconf=$rootprefix/etc/inet/inetd.conf
	inettmp=/tmp/inetd.tmp.$$

	if grep '^#SMFbfu# tftp' $inetconf >/dev/null ; then
		# BFU previously commented out, put it back in place
	    	sed 's/^#SMFbfu# tftp/tftp/' $inetconf > $inettmp &&
		    cp $inettmp $inetconf
	elif ! grep '^[#	 ]*tftp' $inetconf >/dev/null; then
		# No entry, append to end
		cat >>$inetconf <<EOF
# TFTPD - tftp server (primarily used for booting)
#tftp	dgram	udp6	wait	root	/usr/sbin/in.tftpd	in.tftpd -s /tftpboot
EOF
	fi

	rm -f -- $inettmp
}

inetd_conf_svm_hack() {
	# Since inetd.conf is updated by SUNWmdr's postinstall script,
	# we will update the actual inetd.conf here to reflect the postinstall
	# changes.

	inetconf=$rootprefix/etc/inet/inetd.conf
	inettmp=/tmp/inetd.tmp.$$
	inetnew=/tmp/inetd.new.$$

	#
	# only change inetd.conf if the rpc.metad entry is out of date
	#

	if ! grep "^[# 	]*100229/1-2" $inetconf > /dev/null ; then

		# Grab existing rpc entries for rpc.metad
		# and convert spaces to tabs within the rpc entry, as well as
		# the transport method; 
		# or add a new entry in case there was none.
		if grep "^[# 	]*100229/1" $inetconf > /dev/null ; then
			grep "^# METAD - SLVM metadb" $inetconf > $inettmp
			grep "^[# 	]*100229/1" $inetconf | \
			    sed -e 's/[ 	][ 	]*/	/g' \
				-e 's?100229/1?100229/1-2?' >> $inettmp
		else
			echo '# METAD - SVM metadb Daemon' > $inettmp
			echo "100229/1-2\ttli\trpc/tcp\twait\troot\t/usr/sbin/rpc.metad\trpc.metad" >> $inettmp
		fi

		grep -v '^# METAD - SLVM metadb' $inetconf | \
		    grep -v '^[# 	]*100229/1' > $inetnew
		cat $inettmp >> $inetnew

		if ! diff $inetnew $inetconf > /dev/null ; then
			print "Updating inet.conf metad entry ... \c"
			if cp $inetnew $inetconf ; then
				print "done."
			else
				print "failed."
			fi
		fi
		rm -f $inettmp $inetnew
	fi

	#
	# only change inetd.conf if the rpc.mdcommd entry is out of date
	#

	if ! grep "^[# 	]*100422/1" $inetconf > /dev/null ; then

		# Grab existing rpc entries for rpc.mdcommd
		# and convert spaces to tabs within the rpc entry,
		# or add a new entry in case there was none.
		if grep "^[#    ]*100422/1" $inetconf > /dev/null ; then
			grep "^# MDMN_COMMD - SVM Multi node" $inetconf > $inettmp
			grep "^[#       ]*100422/1" $inetconf | \
				sed -e 's/[         ][      ]*/     /g' >> $inettmp 
		else
			echo '# MDMN_COMMD - SVM Multi node communication daemon' >$inettmp
			echo '100422/1\ttli\trpc/tcp\twait\troot\t/usr/sbin/rpc.mdcommd\trpc.mdcommd' >> $inettmp
		fi

		grep -v '^# MDMN_COMMD - SVM Multi node' $inetconf | \
		grep -v '^[#        ]*100422/1' > $inetnew
		cat $inettmp >> $inetnew

		if ! diff $inetnew $inetconf > /dev/null ; then
			print "Updating inetd.conf rpc.mdcommd entry ... \c"
			if cp $inetnew $inetconf; then
				print "done."
			else
				print "failed."
			fi
		fi

		rm -f $inettmp $inetnew
	fi
}

# update x86 version mpt.conf for property tape
mpttapeprop='[ 	]*tape[ 	]*=[ 	]*"sctp"[ 	]*;'
update_mptconf_i386()
{
	conffile=$rootprefix/kernel/drv/mpt.conf
	test -f $conffile || return
	egrep -s "$mpttapeprop" $conffile
	if [ $? -ne 0 ] ; then
	    echo 'tape="sctp";' >> $conffile
	fi
}

update_policy_conf() {
	# update /etc/security/policy.conf with the default
	# Solaris crypt(3c) policy.
	
	dest=$rootprefix/etc/security/policy.conf

	grep 'CRYPT_' $dest > /dev/null 2>&1
	if [ $? = 1 ] ; then
		print "Updating entries for crypt(3c), see policy.conf(4)"
	cat >> $dest <<EOM

# crypt(3c) Algorithms Configuration
#
# CRYPT_ALGORITHMS_ALLOW specifies the algorithms that are allowed to
# be used for new passwords.  This is enforced only in crypt_gensalt(3c).
#
CRYPT_ALGORITHMS_ALLOW=1,2a,md5

# To deprecate use of the traditional unix algorithm, uncomment below
# and change CRYPT_DEFAULT= to another algorithm.  For example,
# CRYPT_DEFAULT=1 for BSD/Linux MD5.
#
#CRYPT_ALGORITHMS_DEPRECATE=__unix__

# The Solaris default is the traditional UNIX algorithm.  This is not
# listed in crypt.conf(4) since it is internal to libc.  The reserved
# name __unix__ is used to refer to it.
#
CRYPT_DEFAULT=__unix__
EOM
	fi
	grep PRIV_ $dest >/dev/null 2>&1
	if [ $? = 1 ]; then
		echo "Updating entries for privileges(5)," \
		     "see policy.conf(4) for details."
cat >> $dest <<EOM
#
# These settings determine the default privileges users have.  If not set,
# the default privileges are taken from the inherited set.
# There are two different settings; PRIV_DEFAULT determines the default
# set on login; PRIV_LIMIT defines the Limit set on login.
# Individual users can have privileges assigned or taken away through
# user_attr.  Privileges can also be assigned to profiles in which case
# the users with those profiles can use those privileges through pfexec(1m).
# For maximum future compatibility, the specifications should
# always include "basic" or "all"; privileges should then be removed using
# the negation.  E.g., PRIV_LIMIT=all,!sys_linkdir takes away only the
# sys_linkdir privilege, regardless of future additional privileges.
# Similarly, PRIV_DEFAULT=basic,!file_link_any takes away only the
# file_link_any privilege from the basic privilege set; only that notation
# is immune from a future addition of currently unprivileged operations to
# the basic privilege set.
# NOTE: removing privileges from the the Limit set requires EXTREME care
# as any set-uid root program may suddenly fail because it lacks certain
# privilege(s).
#
#PRIV_DEFAULT=basic
#PRIV_LIMIT=all
EOM
	fi

}

#
# Cleanup nfsmapid configuration before extracting
# root bits.  Remove if they exist:
#	nfsmapid entry in inetd.conf
#	nfsmapid entry in /etc/net/ti*/services
#
# Going forward neither should exist, but no harm if services entry exists
# Going way backwards (pre-04/28/2004), inetd.conf must exist but will
# be a conflict that should be merged in
#
nfsmapid_cfg() {
	inetdconf=$rootprefix/etc/inet/inetd.conf
	tmpinetcf=/tmp/inetd.conf.$$
	cp -pf ${inetdconf} ${tmpinetcf}
	cat /dev/null > ${inetdconf} 2>&1
       	sed -e "/^#[#	 ]*NFSv4/d"		\
	    -e "/^[#	 ]*100166\/1/d"		\
	    ${tmpinetcf} > ${inetdconf} 2>&1
	rm -f ${tmpinetcf}

	tmpservices=/tmp/services.$$

	services=$rootprefix/etc/net/ticotsord/services
	cp -pf ${services} ${tmpservices}
	cat /dev/null > ${services} 2>&1
       	sed -e "/^[#	 ]*nfsmapid/d"		\
	    ${tmpservices} > ${services} 2>&1
	rm -f ${tmpservices}

	services=$rootprefix/etc/net/ticots/services
	cp -pf ${services} ${tmpservices}
	cat /dev/null > ${services} 2>&1
       	sed -e "/^[#	 ]*nfsmapid/d"		\
	    ${tmpservices} > ${services} 2>&1
	rm -f ${tmpservices}

	services=$rootprefix/etc/net/ticlts/services
	cp -pf ${services} ${tmpservices}
	cat /dev/null > ${services} 2>&1
       	sed -e "/^[#	 ]*nfsmapid/d"		\
	    ${tmpservices} > ${services} 2>&1
	rm -f ${tmpservices}
}

#
# Define global variables
#
CALL_DEVID_DESTROY=""
#
# List of SDS commands that must be deleted.
#
SDSCMDLIST="
growfs
metaclear
metadb
metadetach
metahs
metainit
metaoffline
metaonline
metaparam
metarename
metareplace
metaroot
metaset
metastat
metasync
metattach
rpc.metad
rpc.metamhd
"
#
# List of SDS configuration files that must be deleted.
#
SDSCONFIGLIST="
lock
md.cf
mddb.cf
md.tab
devpath
md.ctlrmap
"
#
# List of rc scripts that must be deleted.
#
RCLIST="
etc/init.d/SUNWmd.init
etc/init.d/SUNWmd.sync
etc/init.d/lvm.init
etc/init.d/lvm.sync
etc/rcS.d/S35SUNWmd.init
etc/rcS.d/S35lvm.init
etc/rc2.d/S95SUNWmd.sync
etc/rc2.d/S95lvm.sync
etc/rcS.d/S35slvm.init
etc/rc2.d/S95slvm.sync
etc/init.d/slvm.init
etc/init.d/slvm.sync
etc/init.d/init.mdlogd
etc/rc3.d/S25mdlogd
"
#
# List of flashprom-related files that must be deleted.
#
FLASHPROMLIST="
etc/rc2.d/S75flashprom
etc/init.d/flashprom
usr/platform/SUNW,Ultra-2/lib/flash-update.sh
usr/platform/SUNW,Ultra-4/lib/flash-update.sh
usr/platform/SUNW,Ultra-Enterprise/lib/flash-update.sh
usr/platform/sun4u/doc/flashupdate.txt
usr/platform/sun4u/lib/flash-update.sh
usr/platform/sun4u/lib/prom/SUNW,Ultra-2
usr/platform/sun4u/lib/prom/SUNW,Ultra-4
usr/platform/sun4u/lib/prom/SUNW,Ultra-Enterprise
"

#
# delete the entries associated with bootlist from /etc/system
#

delete_system_bootlist() {
	sed -e /"Begin MDD database info"/,/"End MDD database info"/d \
	    < ${SYSTEM_FILE} > /tmp/system.$$
	cp /tmp/system.$$ ${SYSTEM_FILE} || \
	    echo "copy error: /tmp/system.$$ to ${SYSTEM_FILE}"
}

#
# Add entries in md.conf for bootlist
#

fix_mdconf() {
	cp ${mdconf} /tmp/md.conf.$$
	echo >> /tmp/md.conf.$$
	echo "# Begin MDD database info (do not edit)" >> /tmp/md.conf.$$
	sed -e 's/^set md://' -e 's/$/;/' ${SYSTEM_FILE} | \
	    grep mddb_bootlist >> /tmp/md.conf.$$
	echo "# End MDD database info (do not edit)" >> /tmp/md.conf.$$
	cp /tmp/md.conf.$$ ${mdconf} || \
	    echo "copy error: /tmp/md.conf.$$ to ${mdconf}"
}

#
# add_devid_destroy(filename)
# returns contents in filename
# md_devid_destroy property is required when upgrading
# from pre SVM to SVM releases or when the device ID returned from
# the driver changes.
# It is specifically placed between
# # Begin MDD database info and # End MDD database info because
# on the subsequent reboot, this line will be removed automatically when
# metadevadm is run in rc2.d.
#
add_devid_destroy() {
	cat $1 | awk '{
		if ( $2 == "End" && $4 == "database") {
			print "md_devid_destroy=1;"
		}
		print $0
	}' >> /tmp/t$$
	mv /tmp/t$$ $1
}

#
# Reads existing configuration values in /etc/rcap.conf and puts 
# them in repository upon reboot(via /var/svc/profile/upgrade).
#
migrate_rcap_conf() {
	RCAP_CONF="${rootprefix}/etc/rcap.conf"
	PROFILE_UPGRADE="${rootprefix}/var/svc/profile/upgrade"
	SVCCFG="/usr/sbin/svccfg"
	RCAP_FMRI="svc:/system/rcap:default"
	PG="config"

	pressure=`awk '$1 == "RCAPD_MEMORY_CAP_ENFORCEMENT_PRESSURE" \
	    && NF == 3 {print $3}' $RCAP_CONF`

	reconfig_int=`awk '$1 == "RCAPD_RECONFIGURATION_INTERVAL" \
	    && NF == 3 {print $3}' $RCAP_CONF`

	walk_int=`awk '$1 == "RCAPD_PROC_WALK_INTERVAL" && \
	    NF == 3 {print $3}' $RCAP_CONF`

	report_int=`awk '$1 == "RCAPD_REPORT_INTERVAL" && \
	    NF == 3 {print $3}' $RCAP_CONF`

	rss_sample_int=`awk '$1 == "RCAPD_RSS_SAMPLE_INTERVAL" && \
	    NF == 3 {print $3}' $RCAP_CONF`

	# Blindly update default configuration values with
	# pre-existing values
	#
	echo "# Migrating pre-existing rcap configuration" >> \
	    $PROFILE_UPGRADE

	echo "$SVCCFG -s $RCAP_FMRI setprop ${PG}/pressure = " \
	    "$pressure" >> $PROFILE_UPGRADE

	echo "$SVCCFG -s $RCAP_FMRI " \
	    "setprop ${PG}/reconfig_interval = $reconfig_int" >> \
	    $PROFILE_UPGRADE

	echo "$SVCCFG -s $RCAP_FMRI " \
	    "setprop ${PG}/walk_interval = $walk_int" >> \
	    $PROFILE_UPGRADE

	echo "$SVCCFG -s $RCAP_FMRI " \
	    "setprop ${PG}/report_interval = $report_int" >> \
	    $PROFILE_UPGRADE

	echo "$SVCCFG -s $RCAP_FMRI " \
	    "setprop ${PG}/rss_sample_interval = $rss_sample_int" >> \
	    $PROFILE_UPGRADE

	echo "/usr/sbin/svcadm refresh $RCAP_FMRI" >> \
	    $PROFILE_UPGRADE

	echo "rm /etc/rcap.conf" >> \
	    $PROFILE_UPGRADE
}

#
# smf(5) "Greenline" doesn't install the init.d or rc*.d scripts for
# converted services.  Clean up previous scripts for such services.
#
smf_obsolete_rc_files="
	etc/init.d/ANNOUNCE
	etc/init.d/MOUNTFSYS
	etc/init.d/RMTMPFILES
	etc/init.d/audit
	etc/init.d/autofs
	etc/init.d/coreadm
	etc/init.d/cron
	etc/init.d/cryptosvc
	etc/init.d/cvc
	etc/init.d/devfsadm
	etc/init.d/dhcp
	etc/init.d/dhcpagent
	etc/init.d/domainname
	etc/init.d/efcode
	etc/init.d/inetd
	etc/init.d/inetinit
	etc/init.d/inetsvc
	etc/init.d/initboot
	etc/init.d/ipfboot
	etc/init.d/kdc
	etc/init.d/kdc.master
	etc/init.d/keymap
	etc/init.d/ldap.client
	etc/init.d/libc.mount
	etc/init.d/network
	etc/init.d/nfs.client
	etc/init.d/nodename
	etc/init.d/nscd
	etc/init.d/perf
	etc/init.d/picld
	etc/init.d/power
	etc/init.d/rcapd
	etc/init.d/rootusr
	etc/init.d/rpc
	etc/init.d/savecore
	etc/init.d/sckm
	etc/init.d/sf880dr
	etc/init.d/slpd
	etc/init.d/sshd
	etc/init.d/standardmounts
	etc/init.d/svm.init
	etc/init.d/svm.sync
	etc/init.d/sysid.net
	etc/init.d/sysid.sys
	etc/init.d/syslog
	etc/init.d/utmpd
	etc/init.d/volmgt
	etc/init.d/xntpd
	etc/init.d/zones
	etc/rc0.d/K00ANNOUNCE
	etc/rc0.d/K01zones
	etc/rc0.d/K03sshd
	etc/rc0.d/K05volmgt
	etc/rc0.d/K07snmpdx
	etc/rc0.d/K10rcapd
	etc/rc0.d/K21dhcp
	etc/rc0.d/K28kdc
	etc/rc0.d/K28kdc.master
	etc/rc0.d/K28nfs.server
	etc/rc0.d/K32cryptosvc
	etc/rc0.d/K33audit
	etc/rc0.d/K33efcode
	etc/rc0.d/K34svm.sync
	etc/rc0.d/K36sendmail
	etc/rc0.d/K36utmpd
	etc/rc0.d/K37power
	etc/rc0.d/K40cron
	etc/rc0.d/K40inetd
	etc/rc0.d/K40nscd
	etc/rc0.d/K40sf880dr
	etc/rc0.d/K40slpd
	etc/rc0.d/K40syslog
	etc/rc0.d/K40xntpd
	etc/rc0.d/K41autofs
	etc/rc0.d/K41ldap.client
	etc/rc0.d/K41nfs.client
	etc/rc0.d/K41rpc
	etc/rc0.d/K42sckm
	etc/rc0.d/K43inet
	etc/rc0.d/K68picld
	etc/rc0.d/K83devfsadm
	etc/rc0.d/K90dhcpagent
	etc/rc1.d/K00ANNOUNCE
	etc/rc1.d/K01zones
	etc/rc1.d/K03sshd
	etc/rc1.d/K05volmgt
	etc/rc1.d/K07snmpdx
	etc/rc1.d/K10rcapd
	etc/rc1.d/K21dhcp
	etc/rc1.d/K28kdc
	etc/rc1.d/K28kdc.master
	etc/rc1.d/K28nfs.server
	etc/rc1.d/K33audit
	etc/rc1.d/K33efcode
	etc/rc1.d/K34svm.sync
	etc/rc1.d/K36sendmail
	etc/rc1.d/K36utmpd
	etc/rc1.d/K37power
	etc/rc1.d/K40cron
	etc/rc1.d/K40inetd
	etc/rc1.d/K40nscd
	etc/rc1.d/K40sf880dr
	etc/rc1.d/K40slpd
	etc/rc1.d/K40syslog
	etc/rc1.d/K40xntpd
	etc/rc1.d/K41autofs
	etc/rc1.d/K41ldap.client
	etc/rc1.d/K41rpc
	etc/rc1.d/K42sckm
	etc/rc1.d/K43inet
	etc/rc1.d/K99libc.mount
	etc/rc1.d/S01MOUNTFSYS
	etc/rc2.d/K01zones
	etc/rc2.d/K03sshd
	etc/rc2.d/K05volmgt
	etc/rc2.d/K07snmpdx
	etc/rc2.d/K21dhcp
	etc/rc2.d/K28kdc
	etc/rc2.d/K28kdc.master
	etc/rc2.d/K28nfs.server
	etc/rc2.d/S01MOUNTFSYS
	etc/rc2.d/S05RMTMPFILES
	etc/rc2.d/S21perf
	etc/rc2.d/S30sysid.net
	etc/rc2.d/S65ipfboot
	etc/rc2.d/S69domainname
	etc/rc2.d/S69inet
	etc/rc2.d/S70sckm
	etc/rc2.d/S71ldap.client
	etc/rc2.d/S71rpc
	etc/rc2.d/S71sysid.sys
	etc/rc2.d/S72inetsvc
	etc/rc2.d/S72slpd
	etc/rc2.d/S73nfs.client
	etc/rc2.d/S74autofs
	etc/rc2.d/S74syslog
	etc/rc2.d/S74xntpd
	etc/rc2.d/S75cron
	etc/rc2.d/S75savecore
	etc/rc2.d/S76nscd
	etc/rc2.d/S77inetd
	etc/rc2.d/S77sf880dr
	etc/rc2.d/S85power
	etc/rc2.d/S88sendmail
	etc/rc2.d/S88utmpd
	etc/rc2.d/S95svm.sync
	etc/rc2.d/S98efcode
	etc/rc2.d/S98libc.mount
	etc/rc2.d/S99audit
	etc/rc2.d/S99rcapd
	etc/rc3.d/S13kdc.master
	etc/rc3.d/S14kdc
	etc/rc3.d/S15nfs.server
	etc/rc3.d/S34dhcp
	etc/rc3.d/S76snmpdx
	etc/rc3.d/S81volmgt
	etc/rc3.d/S89sshd
	etc/rc3.d/S99zones
	etc/rcS.d/K01zones
	etc/rcS.d/K03sshd
	etc/rcS.d/K05volmgt
	etc/rcS.d/K07snmpdx
	etc/rcS.d/K10rcapd
	etc/rcS.d/K21dhcp
	etc/rcS.d/K28kdc
	etc/rcS.d/K28kdc.master
	etc/rcS.d/K28nfs.server
	etc/rcS.d/K33audit
	etc/rcS.d/K33efcode
	etc/rcS.d/K34svm.sync
	etc/rcS.d/K36sendmail
	etc/rcS.d/K36utmpd
	etc/rcS.d/K37power
	etc/rcS.d/K40cron
	etc/rcS.d/K40inetd
	etc/rcS.d/K40nscd
	etc/rcS.d/K40sf880dr
	etc/rcS.d/K40slpd
	etc/rcS.d/K40syslog
	etc/rcS.d/K40xntpd
	etc/rcS.d/K41autofs
	etc/rcS.d/K41ldap.client
	etc/rcS.d/K41rpc
	etc/rcS.d/K42sckm
	etc/rcS.d/K43inet
	etc/rcS.d/K99libc.mount
	etc/rcS.d/S10cvc
	etc/rcS.d/S28network.sh
	etc/rcS.d/S29nodename.sh
	etc/rcS.d/S30rootusr.sh
	etc/rcS.d/S33keymap.sh
	etc/rcS.d/S35svm.init
	etc/rcS.d/S40standardmounts.sh
	etc/rcS.d/S42coreadm
	etc/rcS.d/S45initboot
	etc/rcS.d/S50devfsadm
	etc/rcS.d/S72cryptosvc
	etc/rcS.d/S95picld
"

# Obsolete smf manifests
smf_obsolete_manifests="
	var/svc/manifest/application/print/cleanup.xml
	var/svc/manifest/network/tftp.xml
	var/svc/manifest/network/lp.xml
	var/svc/manifest/system/filesystem/volfs.xml
	var/svc/manifest/network/pfil.xml
	var/svc/manifest/platform/sun4u/mpxio-upgrade.xml
	var/svc/manifest/network/tname.xml
"

# smf services whose manifests have been renamed
smf_renamed_manifests="
	var/svc/manifest/milestone/name-service.xml
	var/svc/manifest/system/filesystem/boot-archive.xml
"

# Obsolete smf methods
smf_obsolete_methods="
	lib/svc/method/print-cleanup
	lib/svc/method/print-server
	lib/svc/method/svc-volfs
	lib/svc/method/pfil
"

smf_cleanup () {
	(
		cd $root;
		print "Removing obsolete rc.d scripts ... \c"
		rm -f $smf_obsolete_rc_files
		print "done."
	)
}

smf_new_profiles () {
	[[ "$bfu_isa" = "sparc" ]] || return 0

	[[ -x /tmp/bfubin/svccfg ]] || return 0

	print "Clearing platform profile hash ..."

	# platform_SUNW,Sun-Fire.xml (and other new and
	# corrected platforms) were delivered in Build 68.
	if [ ! -f \
		$rootprefix/var/svc/profile/platform_SUNW,Sun-Fire.xml \
		]; then
		for pfx in " " "v"; do
			for plname in \
			    none \
			    SUNW_Sun_Fire_880 \
			    SUNW_Sun_Fire_V890 \
			    SUNW_Sun_Fire_15000 \
			    SUNW_UltraEnterprise_10000; do
				svccfg -f - <<EOF
select smf/manifest
delpg ${pfx}ar_svc_profile_platform_${plname}_xml
exit
EOF
			done
		done
	fi
}

smf_handle_new_services () {
	#
	# Detect, prior to extraction the arrival of new,
	# default-enabled-in-profile services.  If so, add a command
	# such that they are enabled.
	#
	if [ ! -f $rootprefix/var/svc/profile/system/sac.xml ]; then
		echo /usr/sbin/svcadm enable system/sac >> \
		    $rootprefix/var/svc/profile/upgrade
	fi
	if [[ $zone = global &&
            ! -f $rootprefix/var/svc/manifest/system/intrd.xml ]]; then
		echo /usr/sbin/svcadm enable system/intrd >> \
		    $rootprefix/var/svc/profile/upgrade
	fi
	if [[ $zone = global &&
	    ! -f $rootprefix/var/svc/manifest/system/scheduler.xml ]]; then
		echo /usr/sbin/svcadm enable system/scheduler >> \
		    $rootprefix/var/svc/profile/upgrade
	fi
	if [[ $zone = global &&
	    ! -f $rootprefix/var/svc/manifest/system/hal.xml ]]; then
		echo /usr/sbin/svcadm enable system/hal >> \
		    $rootprefix/var/svc/profile/upgrade
	fi
	if [[ $zone = global &&
	    ! -f $rootprefix/var/svc/manifest/system/filesystem/rmvolmgr.xml ]]; then
		echo /usr/sbin/svcadm enable system/filesystem/rmvolmgr >> \
		    $rootprefix/var/svc/profile/upgrade
	fi
	if [[ $zone = global &&
	    ! -f $rootprefix/var/svc/manifest/network/ipsec/manual-key.xml &&
	    -f $rootprefix/etc/inet/secret/ipseckeys ]]; then
		smf_enable svc:/network/ipsec/manual-key:default
	fi
	if [[ $zone = global &&
	    ! -f $rootprefix/var/svc/manifest/network/ipsec/ike.xml &&
	    -f $rootprefix/etc/inet/ike/config ]]; then
		smf_enable svc:/network/ipsec/ike:default
	fi
	if [[ $zone = global &&
	    ! -f $rootprefix/var/svc/manifest/system/pools.xml &&
	    -f $rootprefix/etc/pooladm.conf ]]; then
		smf_enable svc:/system/pools:default
	fi
}

smf_copy_manifest() {
	mfstbase=`basename $1`
	mymfs=$rootprefix/var/svc/manifest/$2/$mfstbase
	if [[ ! -f $mymfs ]] || ! cmp -s $manifest_src/$1 $mymfs ; then
		cp $manifest_src/$1 $mymfs ||
		    echo "bfu: could not copy $manifest_src/$1"
	fi
}

smf_copy_method() {
	cp $manifest_src/$1 $rootprefix/lib/svc/method ||
	    echo "bfu: could not copy $manifest_src/$1"
}

smf_cleanup_initd() {
	rm -f $rootprefix/etc/rc?.d/[SK]??$1
}

smf_delete_manifest() {
	(
		mfst=$1
		cd $root
		[ -f $mfst ] || return;
		if [ -r /etc/svc/volatile/repository_door ]; then
			ENTITIES=`/tmp/bfubin/svccfg inventory $mfst`
			for fmri in $ENTITIES; do
				/tmp/bfubin/svccfg delete -f $fmri
			done
		fi
		rm $mfst
	)
}

smf_delete_methods() {
	(
		cd $root;
		rm -f $smf_obsolete_methods
	)
}	

smf_delete_renamed_manifests() {
	(
		cd $root;
		rm -f $smf_renamed_manifests
	)
}

smf_gldv3_manifests="
	var/svc/manifest/network/aggregation.xml
	var/svc/manifest/network/datalink.xml
	var/svc/manifest/network/datalink-init.xml
"
smf_gldv3_methods="
	lib/svc/method/aggregation
	lib/svc/method/datalink
	lib/svc/method/datalink-init
"
smf_cleanup_gldv3() {
	(
		for f in $smf_gldv3_manifests; do
			smf_delete_manifest $f
		done
		cd $root;
		rm -f $smf_gldv3_methods
	)
}

old_mfst_dir="var/svc/manifest.orig"
new_mfst_dir="var/svc/manifest"

smf_enable() {
	echo "svcadm enable $*" >> $rootprefix/var/svc/profile/upgrade
}

smf_check_repository() {
	repository=etc/svc/repository.db
	[[ -f $rootprefix/$repository ]] || return

	print -n "$rootprefix/$repository: " >&2

	sqlite="${SQLITEBIN-$GATE/public/bin/$bfu_isa/sqlite}"
	[[ -x $sqlite ]] || sqlite=/lib/svc/bin/sqlite
	if [[ ! -x $sqlite ]]; then
		echo "no sqlite binary: skipped integrity check" >&2
		return
	fi

	rm -f /tmp/bfurepo.db;
	cp $rootprefix/$repository /tmp/bfurepo.db
	bad_errors=`echo "PRAGMA integrity_check;" |
	    $sqlite /tmp/bfurepo.db 2>&1 | grep -v '^ok$'`
	if [[ $? -eq 0 ]]; then
		echo "integrity check failed:" >&2
		echo "$bad_errors" >&2
		echo >&2
		if [[ $force_override = no ]]; then
			cat >&2 <<EOF
Reseed the repository (see http://greenline.eng/quickstart.shtml#newrep)
before BFUing (or use the -f flag to force BFU to continue).  Re-seeding
will lose all smf(5) customizations.
EOF
			echo >&2
			exit 2;
		else
			echo "driving on anyway" >&2
		fi
	else
		echo "passed integrity check" >&2;
	fi
}

smf_bkbfu_warning() {
	print ""
	print "*************************************************************"
	print " WARNING: BFU'ing $1 backwards across 5090532."
	print " Fixes have been made but the services cannot be refreshed"
	print " on the $1's inactive repository. Next boot for the"
	print " $1 will probably result in maintenance mode due to"
	print " dependency cycles. If so, at the $1's console, run:"
	print ""
	print " /usr/sbin/svcadm refresh system/sysidtool:system"
	print " /usr/sbin/svcadm refresh system/sysidtool:net"
	print " /usr/sbin/svcadm clear milestone/single-user"
	print " /usr/sbin/svcadm clear system/sysidtool:system"
	print " /usr/sbin/svcadm clear system/sysidtool:net"
	print ""
	print " to resolve."
	print " To avoid these problems, reseed the zone's repository."
	print " See http://greenline.eng/quickstart.shtml#newrep ."
	print " Note: Re-seeding will lose all smf(5) customization."
	print "*************************************************************"
	print ""
}

smf_is_sysconfig() {
	#
	# Return success if going to post-5090532, i.e. post-sysconfig bits
	#
	# By now, we're going to post-smf bits - so multi-user.xml must
	# exist (since it was introduced by first SMF putback).
	# 
	# Function return status is return status of last command executed.
	# So, no need to check return status from grep below.

	grep sysconfig $rootprefix/var/svc/manifest/milestone/multi-user.xml \
		>/dev/null 2>&1
}

smf_bkbfu_past_sysconfig() {
	#
	# Check if bfu'ing back from post-5090532 to pre-5090532 bits.
	#
	if [[ -f $rootprefix/var/svc/manifest/milestone/sysconfig.xml ]] &&
	    ! smf_is_sysconfig ; then
		return 0
	fi
	return 1
}

smf_bkbfu_repair_sysconfig() {
	#
	# Perform the necessary corrections when bfu'ing backwards
	# from post-5090532 to pre-5090532 bits.
	#
	# Get the pre-5090532 non-ON manifests, and issue minimal fixes
	# to the repository, to enable re-boot.
	#
	smf_copy_manifest pre-5090532/sysidtool.xml system
	if [[ $zone = global && $karch = i86pc ]]; then
		smf_copy_manifest pre-5090532/kdmconfig.xml platform/i86pc
	fi
	#
	# Now, remove sysidtool:{system, net}'s dependency on
	# single-user and filesystem-local.
	#
	# If $rootprefix is not empty, this could be the global zone,
	# with an alternate root BFU, or a non-global zone. For either
	# case, the repository to be updated is not the live one: use
	# SVCCFG_REPOSITORY to point to the repository to be updated.
	#
	# Note that in the alternate-root case, doing this seems better
	# than forcing the user to re-seed, or to dis-allow it. The
	# issue of svccfg and the repository not matching seems remote,
	# given that from initial SMF integration (on10_64) to on10_74,
	# there was no mismatch. In the remote possibility that there is a
	# mis-match (in the future) causing these calls to be suspect,
	# the user is already being advised, via the warning message, to
	# reseed the repository in case of trouble. If a mis-match is ever
	# introduced, code such as this would have to be fixed, so this
	# aspect of the warning is useful only during the interim period.
	#
	# NOTE that this is not an issue for non-global zones'
	# repositories - they couldn't be out-of-sync with
	# /tmp/bfubin/svccfg.
	#
	if [[ -n $rootprefix ]]; then
		export SVCCFG_REPOSITORY=$rootprefix/etc/svc/repository.db
		if [[ $zone = global ]]; then
			smf_bkbfu_warning "alternate root"
		else
			smf_bkbfu_warning "zone"
		fi
	fi
	#
	# Using the newer "-s" option to svccfg in the following is OK
	# since its introduction preceded 5090532 (and this routine wouldn't
	# be called unless the machine is running post-5090532 bits).
	#
	/tmp/bfubin/svccfg -s system/sysidtool:net delpg single-user
	/tmp/bfubin/svccfg -s system/sysidtool:system delpg single-user
	/tmp/bfubin/svccfg -s system/sysidtool:net delpg filesystem_local
	/tmp/bfubin/svccfg -s system/sysidtool:system delpg filesystem_local

	#
	# On a live system, issue the refresh; For alternate root or non-global
	# zone, the user was asked to issue the refreshes and "clear"s in the
	# message above after a post-bfu reboot.
	#
	if [[ -z $rootprefix ]]; then
		/tmp/bfubin/svcadm refresh system/sysidtool:system \
		    system/sysidtool:net
	fi

	#
	# Now, reset SVCCFG_REPOSITORY, if it was set
	#
	[[ -n $rootprefix ]] && unset SVCCFG_REPOSITORY

	#
	# Remove the sysconfig.xml manifest when going back.  So backward
	# bfu check continues to work, and all manifests are correct.
	#
	cat >> $rootprefix/var/svc/profile/upgrade <<-EOF
	rm -f /var/svc/manifest/milestone/sysconfig.xml
	EOF
}

#
# Return true if $file exists in $archive.  $file may also be a pattern.
#
archive_file_exists()
{
	archive=$1
	file=$2

	$ZCAT $cpiodir/${archive}${ZFIX} | cpio -it 2>/dev/null | \
	    egrep -s "$file"
}

#
# If we're no longer delivering the eeprom service, remove it from the system,
# as eeprom -I is removed as well.
#
smf_fix_i86pc_profile () {
	mfst="var/svc/manifest/platform/i86pc/eeprom.xml"
	profile="var/svc/profile/platform_i86pc.xml"

	if [ ! "$karch" = "i86pc" ]; then
		return
	fi

	if ! archive_file_exists generic.root "^$profile"; then
		rm -f $rootprefix/$profile
		rm -f $rootprefix/var/svc/profile/platform.xml
	fi

	if [ ! -f $rootprefix/$mfst ]; then
		return
	fi

	if archive_file_exists generic.root "^$mfst"; then
		return
	fi

	rm -f $rootprefix/$mfst

	#
	# we must disable via svccfg directly, as manifest-import runs after
	# this service tries to run
	#
	[[ -n "$rootprefix" ]] &&
	    export SVCCFG_REPOSITORY=$rootprefix/etc/svc/repository.db
	/tmp/bfubin/svccfg delete -f platform/i86pc/eeprom
	[[ -n "$rootprefix" ]] && unset SVCCFG_REPOSITORY
}

smf_apply_conf () {
	#
	# Go thru the original manifests and move any that were unchanged
	# (or are not system-provided) back to their proper location.  This
	# will avoid superfluous re-import on reboot, as the inode and mtime
	# are both part of the hash.
	#
	if [ -d $rootprefix/$old_mfst_dir ]; then
		for f in `cd $rootprefix/$old_mfst_dir ; find . -type f`
		do
			old=$rootprefix/$old_mfst_dir/$f
			new=$rootprefix/$new_mfst_dir/$f
			if [ ! -f $new ]; then
				mkdir -m 0755 -p `dirname $new`
				mv $old $new
				continue
			fi
			cmp -s $old $new && mv $old $new
		done
		rm -rf $rootprefix/$old_mfst_dir
	fi

	if [ -f $rootprefix/etc/init.d/inetd ]; then
		#
		# BFUing to non-SMF system -- undo our previous changes,
		# run an old hack, and skip the remainder of this function.
		#
		smf_inetd_reenable
		smf_tftp_reinstall

		# Update inetd.conf only if we find rpc.metad file.
		[ -f $usr/sbin/rpc.metad ] &&
		    inetd_conf_svm_hack

		return
	fi

	#
	# At this point, the archive in question is a SMF version.  If
	# the smf(5) repository does not yet exist, create it by copying
	# the appropriate seed repository.  Since updating of non-global
	# zones only occurs when the live system is bfu'ed, the
	# appropriate seed is guaranteed to exist under the /lib
	# directory.
	#
	repository=$rootprefix/etc/svc/repository.db
	if [ ! -f $repository ]; then
		print "Initializing service configuration repository ..."
		if [ $zone = global ]; then
			cp $rootprefix/lib/svc/seed/global.db $repository
		else
			cp /lib/svc/seed/nonglobal.db $repository
		fi
		chmod 0600 $repository
		chown root:sys $repository
	fi

	print "Removing obsolete smf services ..."
	for f in $smf_obsolete_manifests; do
		smf_delete_manifest $f
	done
	smf_delete_methods
	smf_delete_renamed_manifests
	if [ $need_datalink = no ]; then
		smf_cleanup_gldv3
	fi

	print "Disabling unneeded inetd.conf entries ..."
	smf_inetd_disable
	smf_tftp_reinstall

	print "Connecting platform and name service profiles ..."

	rm -f $rootprefix/var/svc/profile/name_service.xml

	grep ldap $rootprefix/etc/nsswitch.conf >/dev/null 2>&1
	is_ldap=$?
	grep nisplus $rootprefix/etc/nsswitch.conf >/dev/null 2>&1
	is_nisplus=$?
	grep nis $rootprefix/etc/nsswitch.conf >/dev/null 2>&1
	is_nis=$?

	if [ $is_ldap  = 0 ]; then
		ns_profile=ns_ldap.xml
	elif [ $is_nisplus = 0  ]; then
		ns_profile=ns_nisplus.xml
	elif [ $is_nis = 0 ]; then
		ns_profile=ns_nis.xml
	else
		ns_profile=ns_files.xml
	fi

	ln -s $ns_profile $rootprefix/var/svc/profile/name_service.xml

	rm -f $rootprefix/var/svc/profile/inetd_services.xml
	ln -s inetd_upgrade.xml $rootprefix/var/svc/profile/inetd_services.xml

	print "Marking converted services as enabled ..."

	[ -f $rootprefix/etc/resolv.conf ] && smf_enable network/dns/client
	[ -f $rootprefix/etc/inet/dhcpsvc.conf ] && \
	    smf_enable network/dhcp-server
  
	# Not concerned about enabling/disabling rcap but will migrate
	# configuration parameters if rcap.conf exists
	#
	if [ -f $rootprefix/etc/rcap.conf ]; then
		migrate_rcap_conf
	fi

	if [ $zone = global ]; then
		if [ -f $rootprefix/etc/dfs/dfstab ] &&
		    grep '^[ 	]*[^# 	]' $rootprefix/etc/dfs/dfstab \
		    > /dev/null; then
		    	smf_enable network/nfs/server
		fi
	else
		echo "/usr/sbin/svcadm disable network/nfs/server" >> \
		    $rootprefix/var/svc/profile/upgrade
	fi

	[ -f $rootprefix/etc/inet/ntp.conf ] && smf_enable network/ntp


	domainname=`cat $rootprefix/etc/defaultdomain 2>/dev/null`
        if [ ! -z "$domainname" -a -d $rootprefix/var/yp/$domainname ]; then
		smf_enable network/nis/server

		# Determining whether we're a NIS master requires
		# looking through the maps.
		cat >>$rootprefix/var/svc/profile/upgrade <<\_EOF
# Determine whether we are a YP master.
domain=`/usr/bin/domainname`
hostname=`uname -n | cut -d. -f1 | tr '[A-Z]' '[a-z]'`

if [ -x /usr/sbin/makedbm ]; then
	if [ -f /var/yp/NISLDAPmapping ]; then
		master=`/usr/sbin/makedbm -u /var/yp/\$domain/LDAP_passwd.byname | grep YP_MASTER_NAME | nawk '{ print $2 }'`
	else
		master=`/usr/sbin/makedbm -u /var/yp/\$domain/passwd.byname | grep YP_MASTER_NAME | nawk '{ print $2 }'`
	fi
fi

# If we are the master server, enable appropriate services.
if [ "$master" = "$hostname" -a "$YP_SERVER" = "TRUE" ]; then
	/usr/sbin/svcadm enable network/nis/xfr
	/usr/sbin/svcadm enable network/nis/passwd

	if [ ! -f /var/yp/NISLDAPmapping ]; then
		[ -f /var/yp/updaters ] && \
		    /usr/svc/svcadm enable network/nis/update
	fi
fi
_EOF
	fi

	# Check if mddbs don't exist on the image.  If so, disable SVM services.
	MDDB_STATUS=1
	if [ -f $rootprefix/kernel/drv/md.conf ]; then
		sed -e 's/#.*$//' $rootprefix/kernel/drv/md.conf | \
		    egrep '^[        ]*mddb_bootlist' >/dev/null 2>&1
		MDDB_STATUS=$?
	fi

	if [ $MDDB_STATUS -ne 0 ]; then
		for svc in metainit mdmonitor; do
		    echo "/usr/sbin/svcadm disable system/$svc:default" >> \
			$rootprefix/var/svc/profile/upgrade
		done

		for svc in meta mdcomm metamed metamh; do
		    echo "/usr/sbin/svcadm disable network/rpc/$svc:default" \
			>> $rootprefix/var/svc/profile/upgrade
		done
	fi

	# Workaround inetd's handling of "tcp6/udp6" when no IPv6 interfaces
	# are configured.
	for svc in meta mdcomm metamed metamh; do
	    echo "/usr/sbin/inetadm -m network/rpc/$svc:default proto=tcp" \
		">/dev/null 2>&1" >> $rootprefix/var/svc/profile/upgrade
	done

	manifest_src=${MANIFEST_SRC-$GATE/public/smf}
	[[ -d $manifest_src ]] ||
	    manifest_src=/net/onnv.eng/export/gate/public/smf
	[[ -d $manifest_src ]] || manifest_src=/net/greenline.eng/meta0/smf

	if smf_bkbfu_past_sysconfig ; then
		echo "BFU'ing backwards across 5090532! Now repairing..."
		smf_bkbfu_repair_sysconfig
	fi

	#
	# If bfu'ing milestone/sysconfig bits or onwards, update the
	# corresponding non-ON manifests - sysidtool and kdmconfig.
	#
	sysidmfst=$rootprefix/var/svc/manifest/system/sysidtool.xml
	kdmmfst=$rootprefix/var/svc/manifest/platform/i86pc/kdmconfig.xml
	if smf_is_sysconfig ; then
		if [[ ! -f $sysidmfst ]]; then
			#
			# if WOS build on machine is pre-greenline, and
			# we're bfu'ing to the sysconfig bits.
			#
			smf_copy_manifest post-5090532/sysidtool.xml system
			if [[ $zone = global ]]; then
				smf_copy_method sysidtool-net
				smf_copy_method sysidtool-system
			fi
			echo "Converted system/sysidtool (post-5090532)"
		else
			#
			# If sysidtool.xml already exists, update it
			# if necessary. Future updates of sysidtool.xml
			# must occur in the dir: $manifest_src/post-5090532
			#
			smf_copy_manifest post-5090532/sysidtool.xml system
		fi
		if [[ $zone = global && $karch = i86pc ]]; then
			if [[ ! -f $kdmmfst ]]; then
				#
				# if WOS build on machine is pre-greenline, and
				# we're bfu'ing to the sysconfig bits.
				#
				smf_copy_manifest post-5090532/kdmconfig.xml \
				    platform/i86pc
				smf_copy_method   svc-kdmconfig
				smf_cleanup_initd kdmconfig
				echo "Converted platform/i86pc/kdmconfig"
				echo "(post-5090532)"
			else
				#
				# If kdmconfig.xml already exists, update
				# it if necessary. Future updates of
				# kdmconfig.xml must occur in the dir:
				# $manifest_src/post-5090532
				#
				smf_copy_manifest post-5090532/kdmconfig.xml \
				    platform/i86pc
			fi
		fi
	else
		if [[ ! -f $sysidmfst ]]; then
			smf_copy_manifest pre-5090532/sysidtool.xml system
			if [[ $zone = global ]]; then
				smf_copy_method sysidtool-net
				smf_copy_method sysidtool-system
			fi
			echo "Converted system/sysidtool"
		fi
		if [[ $zone = global && $karch = i86pc && ! -f $kdmmfst ]];
		then
			smf_copy_manifest pre-5090532/kdmconfig.xml \
			    platform/i86pc
			smf_copy_method   svc-kdmconfig
			smf_cleanup_initd kdmconfig
			echo "Converted platform/i86pc/kdmconfig"
		fi
	fi

	# If we've still got the old dtlogin manifest delivered by earlier
	# versions of bfu, delete it, as it was broken and should have
	# never been delivered.  A new version delivered by the CDE
	# consolidation should be left alone.
	if [[ -f $rootprefix/var/svc/manifest/application/dtlogin.xml &&
	    `grep -c GLXXX \
	    $rootprefix/var/svc/manifest/application/dtlogin.xml` -gt 0 &&
	    -x /tmp/bfubin/svccfg ]]; then

		# Delete the obsolete manifest.
		rm -f $rootprefix/var/svc/manifest/application/dtlogin.xml

		# Delete the service from repository, then use dtconfig -e to
		# revert to whatever the WOS bits are using if dtlogin was
		# enabled.
		cat >> $rootprefix/var/svc/profile/upgrade <<-EOFA
if /usr/bin/svcprop -q application/cde-login; then
	if [ \`/usr/bin/svcprop -p general/enabled \
		application/cde-login:default\` = "true" ]; then
		do_dtconfig=1;
	else
		do_dtconfig=0;
	fi

	/usr/sbin/svccfg delete -f application/cde-login
	type instance_refresh 2>&1 > /dev/null
	if [ \$? = 0 ]; then
		instance_refresh system/console-login
	else
		/usr/sbin/svcadm refresh system/console-login
	fi

	if [ \$do_dtconfig -eq 1 -a -x /usr/dt/bin/dtconfig ]; then
		/usr/dt/bin/dtconfig -e
	fi
fi
EOFA
	fi


	# Enable the inetd-upgrade service to convert any changes to inetd.conf
	smf_enable network/inetd-upgrade

	# If global zone, and bfu'ing from smf, and the inetd-upgrade
	# service has an obsolete dependency, then add a clear of inetd
	# and inetd-upgrade to the upgrade file as either may drop into
	# maintenance due to a dependency loop resulting from the new
	# inetd manifest
	if [[ $zone = global && -x /tmp/bfubin/svccfg ]]; then
		/tmp/bfubin/svcprop -q -p network/entities network/inetd-upgrade
		if [[ $? = 0 ]]; then
		    	echo "/usr/sbin/svcadm clear network/inetd" >> \
			    $rootprefix/var/svc/profile/upgrade
			echo "/usr/sbin/svcadm clear network/inetd-upgrade" >> \
			    $rootprefix/var/svc/profile/upgrade
		fi
	fi

	# If we're in the global zone, and using an alternate root, see if
	# we are in an smf root.  If so, import name-service-cache. If we're
	# not bfu'ing an alternate root, and we're post-smf, import
	# name-service-cache.  This is to get name-service-cache(with correct
	# dependencies) in the repository before reboot.  If we're bfu'ing
	# from pre-smf, this isn't an issue, as name-service-cache will be
	# installed with correct dependencies.
	if [[ $zone = global &&
	    -f $rootprefix/var/svc/manifest/system/name-service-cache.xml ]];
	    then
		if [[ -n $rootprefix ]]; then
			if [ -x /usr/sbin/svccfg ]; then
			SVCCFG_REPOSITORY=$rootprefix/etc/svc/repository.db
			/usr/sbin/svccfg import \
		    $rootprefix/var/svc/manifest/system/name-service-cache.xml
			else
			echo "Warning: This system does not have SMF, so I "
			echo "cannot ensure the pre-import of "
			echo "name-service-cache.  If name-service-cache does "
			echo "not work, reboot your alternate root to fix it."
			fi
		elif [ -x /tmp/bfubin/svccfg ]; then
			/tmp/bfubin/svccfg import \
			    /var/svc/manifest/system/name-service-cache.xml
		fi
	fi

	# If we're in the global zone, and using an alternate root, see if
	# we are in an smf root.  If so, import datalink and aggregation svcs.
	# If we're not bfu'ing an alternate root, and we're post-smf,
	# import datalink and aggregation.  This is to get them 
	# in the repository before reboot.  If we're bfu'ing from pre-smf,
	# this isn't an issue, as they are in the seed repository.
	if [[ $zone = global &&
	    -f $rootprefix/var/svc/manifest/network/datalink.xml ]]; then
		if [[ -n $rootprefix ]]; then
			if [ -x /usr/sbin/svccfg ]; then
			SVCCFG_REPOSITORY=$rootprefix/etc/svc/repository.db
			sed -e "s/enabled='true'/enabled='false'/" \
			 $rootprefix/var/svc/manifest/network/aggregation.xml \
			    | svccfg import -
			sed -e "s/enabled='true'/enabled='false'/" \
			    $rootprefix/var/svc/manifest/network/datalink.xml \
			    | svccfg import -
			sed -e "s/enabled='true'/enabled='false'/" \
		       $rootprefix/var/svc/manifest/network/datalink-init.xml \
			    | svccfg import -
			else
			echo "Warning: This system does not have SMF, so I"
			echo "cannot ensure the pre-import of datalink and"
			echo "network aggregation.  If they do not work"
			echo "reboot your alternate root to fix it."
			fi
		elif [ -x /tmp/bfubin/svccfg ]; then
			sed -e "s/enabled='true'/enabled='false'/" \
			    /var/svc/manifest/network/aggregation.xml | \
			    svccfg import -
			sed -e "s/enabled='true'/enabled='false'/" \
			    /var/svc/manifest/network/datalink.xml | \
			    svccfg import -
			sed -e "s/enabled='true'/enabled='false'/" \
			    /var/svc/manifest/network/datalink-init.xml | \
			    svccfg import -
		fi

		#
		# Make sure the services are enabled after reboot.
		#
		enable_next_boot svc:/network/aggregation:default
		enable_next_boot svc:/network/datalink:default
		enable_next_boot svc:/network/datalink-init:default
	fi

	# Enable new NFS status and nlockmgr services if client is enabled
	cat >> $rootprefix/var/svc/profile/upgrade <<-EOF
	    cl="svc:/network/nfs/client:default"
	    if [ \`/usr/bin/svcprop -p general/enabled \$cl\` = "true" ]; then
		/usr/sbin/svcadm enable svc:/network/nfs/status:default
		/usr/sbin/svcadm enable svc:/network/nfs/nlockmgr:default
	    fi

EOF

	kpmani="$rootprefix/var/svc/manifest/network/security/krb5_prop.xml"
	if grep svc-kdc.slave $kpmani > /dev/null 2>&1; then
		cat >> $rootprefix/var/svc/profile/upgrade <<EOF
		# We are deleting and reimporting kpropd's manifest, because we
		# need to change the restarter.
		kpfmri="svc:/network/security/krb5_prop"
		kkfmri="svc:/network/security/krb5kdc:default"
		lkpmani="/var/svc/manifest/network/security/krb5_prop.xml"
		restarter=\`svcprop -c -p general/restarter \$kpfmri 2>&1\`
		case \$restarter in
			*network/inetd:default)
				kken=\`svcprop -c -p general/enabled \$kkfmri\`
				svccfg delete -f \$kpfmri
				svccfg import \$lkpmani 
				# Enable kpropd if krb5kdc is enabled, since
				# krb5kdc would have run kpropd
				if [ \$kken = "true" ]; then
					svcadm enable \$kpfmri
				fi
				;;
		esac
EOF
	fi

	# Enable print server if there are local queues
	queues=`echo $rootprefix/etc/lp/printers/*/configuration`
	if [ "$queues" != "$rootprefix/etc/lp/printers/*/configuration" ]; then
		smf_enable application/print/server
	fi

	# Enable rarpd and bootparamd if they would have been running pre-SMF
	if [ -d $rootprefix/tftpboot ] || [ -d $rootprefix/rplboot ]; then
		smf_enable network/rarp
		smf_enable network/rpc/bootparams
	fi

	# To handle the transition from pre-smf ipfilter to smf-aware ipfilter,
	# check if ipfilter had been enabled with at least one rule, and if so
	# enable the smf instance.
	if grep '^[ \t]*[^# \t]' $rootprefix/etc/ipf/ipf.conf >/dev/null 2>&1 &&
	    [[ $zone = global ]]; then
		smf_enable network/ipfilter
	fi

	touch $rootprefix/var/svc/profile/.upgrade_prophist

	cat >> $rootprefix/var/svc/profile/upgrade <<EOF
	# We are deleting and reimporting dcs's manifest, because we
	# need to change the restarter.
	dcsfmri="svc:/platform/sun4u/dcs:default"
	dcsmani="/var/svc/manifest/platform/sun4u/dcs.xml"
	restarter=\`svcprop -c -p general/restarter \$dcsfmri 2>&1\`
	case \$restarter in
		*network/inetd:default)
			en=\`svcprop -c -p general/enabled \$dcsfmri\`
			svccfg delete -f \$dcsfmri
			svccfg import \$dcsmani
			if [ \$en = "true" ]; then
				svcadm enable \$dcsfmri
			fi
			;;
	esac
EOF

	smf_fix_i86pc_profile
}

#
# The directboot putback moved the console property from
# /boot/solaris/bootenv.rc to /boot/grub/menu.lst.  It should be kept in both.
#
cleanup_eeprom_console()
{
	bootenvrc="$root/boot/solaris/bootenv.rc"
	menu_console=`eeprom console 2>/dev/null | \
	    grep -v 'data not available' | cut -d= -f2-`
	bootenv_console=`grep '^setprop[	 ]\{1,\}console\>' $bootenvrc`
	if [ -n "$menu_console" ] && [ -z "$bootenv_console" ]; then
		echo "setprop console '$menu_console'" >> $bootenvrc
	fi
}

EXTRACT_LOG=/tmp/bfu-extract-log.$$

rm -f $EXTRACT_LOG

extraction_error() {
	echo error $* >> $EXTRACT_LOG
}

#
# Make a local copy of bfu in /tmp and execute that instead.
# This makes us immune to loss of networking and/or changes
# to the original copy that might occur during execution.
#
cd .
abspath=`[[ $0 = /* ]] && print $0 || print $PWD/$0`
if [[ $abspath != /tmp/* ]]; then
	localpath=/tmp/bfu.$$
	print "Copying $abspath to $localpath"
	cp $abspath $localpath
	chmod +x $localpath
	print "Executing $localpath $*\n"
	exec $localpath $*
fi

export PATH=/usr/bin:/usr/sbin:/sbin

usage() {
	echo "Usage:"
	echo "    bfu    [-fh] <archive_dir> [root-dir]"
	echo "\tUpdate a single machine by loading archives on root-dir."
	echo "\troot-dir defaults to / (a live bfu).\n"
	echo "    bfu -c [-fh] <archive_dir> <exec-dir>"
	echo "\tUpdate all diskless clients by loading archives on each client"
	echo "\tthat mounts exec-dir as /usr.  <exec-dir> must start with"
	echo "\t/export/exec and each client's root must be in /export/root.\n"
	echo "\t-f        force bfu to continue even if it doesn't seem safe"
	fail "\t-h|-help  print this usage message and exit\n"
}

diskless=no
force_override=no
while [ $# -gt 0 ]; do
	case $1 in
		-c)		diskless=yes;;
		-f)		force_override=yes;;
		-h|-help)	usage;;
		*)      	break;;
	esac
	shift
done

# Variables for x86 platforms
boot_is_pcfs=no
have_realmode=no
is_pcfs_boot=no
need_datalink=no
new_dladm=no

# Set when moving to either directboot or multiboot
multi_or_direct=no

#
# Shows which type of archives we have, which type of system we are
# running on (before the bfu), and what the failsafe archives are
# (again, before the bfu).  failsafe_type is only needed on diskful
# bfu's, so it's not set in the diskless case.
# Possible values: unknown, dca, multiboot, directboot, xpv
#
archive_type=unknown
system_type=unknown
failsafe_type=unknown

test $# -ge 1 || usage

if [ -x /usr/bin/ppriv ]; then
	# We prefer to use ppriv, as it is a more accurate test, and also
	# has the benefit of preventing use from within a nonglobal zone.
	ppriv $$ | grep -w "E: all" > /dev/null 2>&1 || \
	    fail "bfu requires all privileges"
else
	# Fall back to old id check if system does not yet have ppriv.
	uid=`id | nawk '{print $1}'`
	[ "$uid" = "uid=0(root)" ] || \
	    fail "You must be super-user to run this script."
fi

bfu_isa=`uname -p`
target_isa=$bfu_isa
karch=`uname -m`
plat=`uname -i`

cpiodir=$1

if [ "$cpiodir" = again ]; then
	cpiodir=`nawk '/^bfu.ed from / { print $3; exit }' /etc/motd`
fi

[[ "$cpiodir" = */* ]] || cpiodir=$ARCHIVE/archives/$target_isa/$1

[[ "$cpiodir" = /* ]] || fail "archive-dir must be an absolute path"

cd $cpiodir
case `echo generic.root*` in
	generic.root)		ZFIX="";	ZCAT="cat";;
	generic.root.gz)	ZFIX=".gz";	ZCAT="gzip -d -c";;
	generic.root.Z)		ZFIX=".Z";	ZCAT="zcat";;
	*) fail "generic.root missing or in unknown compression format";;
esac

#
# Determine what kind of archives we're installing, using the following rules:
#
# 1. If i86xpv archives exist, the archives are xpv
# 2. If strap.com is present, the archives are pre-multiboot
# 3. If symdef is present, the archives are directboot
# 4. Otherwise, the archives are multiboot
#
if [ $target_isa = i386 ]; then
	if [ -f $cpiodir/i86xpv.root$ZFIX ]; then
		archive_type=xpv
		multi_or_direct=yes
	elif [ -f $cpiodir/i86pc.boot$ZFIX ] && \
	    archive_file_exists i86pc.boot "strap.com"; then
		archive_type=dca
	elif [ -f $cpiodir/i86pc.root$ZFIX ] && \
	    archive_file_exists i86pc.boot symdef; then
		archive_type=directboot
		multi_or_direct=yes
	else
		archive_type=multiboot
		multi_or_direct=yes
	fi
fi

if [ $diskless = no ]; then
	root=${2:-/}
	[[ "$root" = /* ]] || fail "root-dir must be an absolute path"
	usrroot=$root
	usr=${usrroot%/}/usr
	rootlist=$root

	[[ -f $root/etc/system ]] || \
	    fail "$root/etc/system not found; nonglobal zone target not allowed"

	# Make sure we extract the sun4u-us3 libc_psr.so.1
	if [ -d $root/platform/sun4u -a \
	   ! -d $root/platform/sun4u-us3 ]
	then
		mkdir $root/platform/sun4u-us3
		chmod 755 $root/platform/sun4u-us3
		chown root $root/platform/sun4u-us3
		chgrp sys $root/platform/sun4u-us3
	fi

	if [ $target_isa = i386 -a $archive_type = xpv ]; then
		#
		# On i386, we want to apply the archives for both platforms
		# (i86pc and i86xpv) if they exist.  We force the platform
		# to i86xpv so that both will be applied.
		#
		karch=i86pc
		plat=i86xpv
	fi

	if [ $karch != $plat -a -f ${cpiodir}/${plat}.usr$ZFIX ]; then
		usrarchs="$karch $plat"
	else
		usrarchs="$karch"
	fi
	if [ $karch != $plat -a -f ${cpiodir}/${plat}.root$ZFIX ]; then
		rootarchs="$karch $plat"
	else
		rootarchs="$karch"
	fi

	if [ -h ${root}/platform/${plat} ]; then
		rm -f ${root}/platform/${plat}
	fi
	if [ -h ${usr}/platform/${plat} ]; then
		rm -f ${usr}/platform/${plat}
	fi

	if [ $plat != $karch -a -f ${cpiodir}/${plat}.root$ZFIX \
	    -a -f ${cpiodir}/${plat}.usr$ZFIX ]
	then
		cd $cpiodir
		#
		#  Look through all the archives we build and match
		#  the names of built archives with the names of
		#  directories installed on this machine.  We assume
		#  here that we can get the names of all architectures
		#  by pattern matching the names of .root archives - so
		#  if we ever had a case where we had only a .usr archive
		#  we wouldn't find that archive.
		#
		for i in *.root*
		do
			platname=${i%.root*}
			if [ -z "${platname}" -o ${platname} = $karch -o \
			    $platname = generic -o ${platname} = $plat ]; then
				continue;
			fi
			if [ -d ${root}/platform/${platname} -o \
			    -h ${root}/platform/${platname} ]; then
				rootarchs="${rootarchs} ${platname}"
			fi
			if [ -d ${usr}/platform/${platname} -o \
			    -h ${usr}/platform/${platname} ]; then
				usrarchs="${usrarchs} ${platname}"
			fi
			if [ -h ${root}/platform/${platname} ]; then
				rm -f ${root}/platform/${platname}
			fi
			if [ -h ${usr}/platform/${platname} ]; then
				rm -f ${usr}/platform/${platname}
			fi
		done
	fi
	rootslice=`df -k $root | nawk 'NR > 1 { print $1 }' | sed s/dsk/rdsk/`
	print "Loading $cpiodir on $root"
else
	usrroot=$2
	usr=$2/usr
	[[ "$usr" = /export/exec/* ]] || fail "exec-dir $usrroot sounds bogus"
	case $2 in
	    *sparc*)
		target_isa=sparc ;;
	    *i386*)
		target_isa=i386 ;;
	esac
	cd $cpiodir
	test -f generic.root$ZFIX || fail "$cpiodir/generic.root$ZFIX missing"
	allarchs=$(echo $(ls *.root$ZFIX | grep -v generic.root$ZFIX | \
		sed -e 's/.root.*//'))

	if [ $target_isa = i386 -a $archive_type = xpv ]; then
		#
		# On i386, we want to apply the archives for both platforms
		# (i86pc and i86xpv) if they exist.  We force the platform
		# to i86xpv so that both will be applied.
		#
		karch=i86pc
		plat=i86xpv
	else
		# XXX Pick karch as last available root arch
		karch=${allarchs##* }
		# XXX Pick plat as first available root arch
		plat=${allarchs%% *}
	fi

	rootlist=""
	for root in /export/root/*
	do
		test -f $root/etc/vfstab &&
			egrep -s $usrroot $root/etc/vfstab &&
			rootlist="$rootlist $root"
	done
	test -n "$rootlist" || fail "no clients to upgrade"
	print "Loading $cpiodir usr archives on:\n\t$usr\n"
	print "Loading $cpiodir root archives on:"
	for root in $rootlist
	do
		print "\t$root"
	done
fi

if grep '^[ 	]*zfsroot:' $root/etc/system >/dev/null && \
	    archive_file_exists i86pc.boot boot/grub/zfs_stage1_5; then
	echo "Cannot BFU a system with the mountroot version"\
		"of zfs boot support."
	echo "For information on how to transition this system to the new"
	echo "zfs boot support, see:"
	echo "http://www.opensolaris.org/os/community/zfs/boot/zfsboot-manual/mntroot-transition/"
	fail ""
fi

nss_lib="$usr/lib/mps/libnss3.so"
nss_lib64="$usr/lib/mps/64/libnss3.so"
valid_rpath="\$ORIGIN:/usr/lib/mps/secv1:/usr/lib/mps"
rpath_msg="R(UN)?PATH from file ${nss_lib}\)"
if [ ! -x /usr/bin/ldd ]; then
	if [ "$force_override" = yes ]; then
		echo "/usr/bin/ldd is missing but -f is set; continuing."
	else
		echo "/usr/bin/ldd is missing."
		fail "Install the SUNWtoo package."
	fi
fi
nss_rpath=`ldd -s $nss_lib | egrep "$rpath_msg" | head -1 | cut -d'=' -f2 | \
		awk '{print $1}'`
update_script="/ws/onnv-gate/public/bin/update_nsspkgs"
if [ $valid_rpath != "$nss_rpath" ]; then
	if [ "$force_override" = yes ]; then
		echo "$nss_lib is not valid but -f is set; continuing."
	else
		echo "$nss_lib is not valid."
		fail "Run $update_script to update the SUNWtls package."
	fi
fi
if [ $target_isa = i386 -a ! -f $nss_lib64 ]; then
	echo "$nss_lib64 does not exist."
	fail "Run $update_script to update the NSS packages."
fi

update_script="/ws/onnv-gate/public/bin/migrate_bind9"
if [[ ! -f $usr/lib/dns/libdns.so ]] && ! $ZCAT $cpiodir/generic.usr$ZFIX | \
	    cpio -it 2>/dev/null |  egrep -s '^usr/sbin/ndc' ; then
	if [ "$force_override" = yes ]; then
		echo "BIND 9 has not been installed, but -f is set; continuing."
	else
		echo "BIND 8 has been removed from ON; BIND 9 is available from SFW."
		fail "Run $update_script to migrate to BIND 9."
	fi
fi

update_script="/ws/onnv-gate/public/bin/update_ce"
if ifconfig -a | egrep '^ce' >/dev/null 2>/dev/null; then
	# CE version 1.148 or later is required
	cever=`modinfo | grep 'CE Ethernet' | sed 's/.*v1\.//' | tr -d ')' | \
	    nawk '{ if ($1 < 148) print "BAD"; else print $1 }'`
	if [ "$cever" = "BAD" ]; then
		fail "You must run $update_script to upgrade your ce driver."
	fi
fi

update_script="/ws/onnv-gate/public/bin/update_dbus"
if [ ! -x $usr/lib/dbus-daemon ]; then
	fail "Run $update_script to update D-Bus."
fi

#
# We need biosdev if we're moving from pre-multiboot to multiboot or directboot
# kernels.  If we already have an i86xpv kernel, then we must already be a
# directboot kernel, and can therefore skip the check.
#
if [ $target_isa = i386 ] && [ $multi_or_direct = yes ] && \
    [ $diskless = no ] && [ ! -d /platform/i86xpv/ ]; then
	prtconf -v | grep biosdev >/dev/null 2>&1
	if [ $? -ne 0 ] && [ ! -f $rootprefix/platform/i86pc/multiboot ]; then
		echo "biosdev cannot be run on this machine."
		echo "Transitioning from classic to multiboot requires a"
		echo "bootconf which is compatible with biosdev."
		echo "bfu to onnv_12 first, then to a build with multiboot."
		fail ""
	fi
fi

if $ZCAT $cpiodir/generic.root$ZFIX | cpio -it 2>/dev/null | \
    grep datalink.conf > /dev/null 2>&1 ; then
	need_datalink=yes
fi

#
# Check whether the archives have an etc/dladm directory; this is
# later used to determine if aggregation.conf needs to be moved.
#
if $ZCAT $cpiodir/generic.root$ZFIX | cpio -it 2>/dev/null | \
    grep etc/dladm > /dev/null 2>&1 ; then
	new_dladm=yes
fi

time_ref=/tmp/bfu.time_ref.$$
rm -f $time_ref
touch $time_ref || fail "$time_ref: Unable to create time reference."
time_ref_seconds=$SECONDS

print "\nCreating bfu execution environment ..."

#
# Save off a few critical libraries and commands, so that bfu will
# continue to function properly even in the face of major
# kernel/library/command incompatibilities during a live upgrade.
#
bfucmd="
	/usr/bin/awk
	/usr/bin/cat
	/usr/bin/chgrp
	/usr/bin/chmod
	/usr/bin/chown
	/usr/bin/cmp
	/usr/bin/cp
	/usr/bin/cpio
	/usr/bin/csh
	/usr/bin/cut
	/usr/bin/date
	/usr/bin/dd
	/usr/bin/df
	/usr/bin/diff
	/usr/bin/du
	/usr/bin/echo
	/usr/bin/ed
	/usr/bin/egrep
	/usr/bin/env
	/usr/bin/ex
	/usr/bin/expr
	/usr/bin/false
	/usr/bin/fgrep
	/usr/bin/file
	/usr/bin/find
	/usr/bin/gettext
	/usr/bin/grep
	/usr/bin/head
	/usr/bin/id
	/usr/bin/ksh
	/usr/bin/line
	/usr/bin/ln
	/usr/bin/ls
	/usr/bin/mkdir
	/usr/bin/mktemp
	/usr/bin/more
	/usr/bin/mv
	/usr/bin/nawk
	/usr/bin/pgrep
	/usr/bin/pkginfo
	/usr/bin/pkill
	/usr/bin/printf
	/usr/bin/ps
	/usr/bin/ptree
	/usr/bin/rm
	/usr/bin/rmdir
	/usr/bin/sed
	/usr/bin/sh
	/usr/bin/sleep
	/usr/bin/sort
	/usr/bin/strings
	/usr/bin/stty
	/usr/bin/su
	/usr/bin/sum
	/usr/bin/tail
	/usr/bin/tee
	/usr/bin/touch
	/usr/bin/tr
	/usr/bin/true
	/usr/bin/truss
	/usr/bin/tty
	/usr/bin/uname
	/usr/bin/uniq
	/usr/bin/uptime
	/usr/bin/vi
	/usr/bin/w
	/usr/bin/wc
	/usr/bin/xargs
	/usr/bin/zcat
	/usr/sbin/add_drv
	/usr/sbin/chroot
	/usr/sbin/halt
	/usr/sbin/lockfs
	/usr/sbin/lofiadm
	/usr/sbin/mkfile
	/usr/sbin/mkfs
	/usr/sbin/mknod
	/usr/sbin/mount
	/usr/sbin/newfs
	/usr/sbin/pkgrm
	/usr/sbin/prtconf
	/usr/sbin/reboot
	/usr/sbin/sync
	/usr/sbin/tar
	/usr/sbin/uadmin
	/usr/sbin/umount
	/usr/sbin/wall
	/usr/sbin/zonecfg
	${FASTFS-$GATE/public/bin/$bfu_isa/fastfs}
	${GZIPBIN-$GATE/public/bin/$bfu_isa/gzip}
"

#
# Scripts needed by BFU. These must be modified to use the interpreters in
# /tmp/bfubin. The interpreters in /usr/bin may not be compatible with the
# libraries in the archives being extracted.
#
bfuscr="
	${ACR-${GATE}/public/bin/acr}
"

#
# basename and dirname may be ELF executables, not shell scripts;
# make sure they go into the right list.
#
if `file /usr/bin/basename | grep ELF >/dev/null`
then	bfucmd="$bfucmd /usr/bin/basename"
else	bfuscr="$bfuscr /usr/bin/basename"
fi

if `file /usr/bin/dirname | grep ELF >/dev/null`
then	bfucmd="$bfucmd /usr/bin/dirname"
else	bfuscr="$bfuscr /usr/bin/dirname"
fi

rm -rf /tmp/bfubin
mkdir /tmp/bfubin
set $bfucmd
isalist=`isalist`
while [ $# -gt 0 ]
do
	dir=${1%/*}
	cmd=${1##*/}
	cd $dir
	isacmd=`(find $isalist -name $cmd 2>/dev/null; echo $cmd) | head -1`
	cp $dir/$isacmd /tmp/bfubin || fail "cannot copy $dir/$isacmd"
	shift
done

#
# Optional commands.  We warn, but do not abort, if we are crossing a
# feature boundary (where a command is not present in the parent).
# Clauses requiring these commands must explicitly test for their
# presence in /tmp/bfubin.
#
bfuoptcmd="
	/sbin/biosdev
	/sbin/bootadm
	/sbin/installgrub
	/usr/sbin/fdisk
	/usr/sbin/metastat
	/usr/bin/mkisofs
	/usr/sbin/svcadm
	/usr/sbin/svccfg
	/usr/bin/svcprop
"

set $bfuoptcmd
isalist=`isalist`
while [ $# -gt 0 ]
do
	dir=${1%/*}
	cmd=${1##*/}
	cd $dir
	isacmd=`(find $isalist -name $cmd 2>/dev/null; echo $cmd) | head -1`
	cp $dir/$isacmd /tmp/bfubin 2>/dev/null
	shift
done

#
# set up installgrub and friends if transitioning to multiboot or directboot
# do this now so ldd can determine library dependencies
#
# We split the binaries into two groups: the type where we want to make any
# effort to get the newest version (like symdef and bootadm), and the type
# where any old version will do (like installgrub and biosdev).
#
# If we're bfu'ing across the directboot/multiboot boundary, we need the new
# bootadm and symdef to properly handle menu.lst changes.  If the system is
# directboot, we can use the local copies.  If the system is multiboot but
# the archives are directboot, we extract the binaries early.  Otherwise,
# we're not crossing the boundary, and which one we use doesn't matter.
#
# NB - if bootadm or symdef is ever changed to require a new library, the
# early extraction will blow up horribly.
#
# For testing purposes, a user can set DIRECTBOOT_BIN_DIR in the environment,
# and we'll use that instead.
#
MULTIBOOT_BIN_DIR=${MULTIBOOT_BIN_DIR:=${GATE}/public/multiboot}
have_new_bootadm=unknown

if [ -f "$root/platform/i86xpv/kernel/unix" ]; then
	root_is_xpv=yes
	root_is_directboot=yes
elif [ -x "$root/boot/solaris/bin/symdef" ] && \
    "$root"/boot/solaris/bin/symdef "$root/platform/i86pc/kernel/unix" \
    dboot_image; then
	root_is_xpv=no
	root_is_directboot=yes
else
	root_is_xpv=no
	root_is_directboot=no
fi

#
# A comma-separated list of the command and the archive it's in
#
multiboot_new_cmds="
	sbin/bootadm,generic.sbin
	boot/solaris/bin/symdef,i86pc.boot
"

if [ $multi_or_direct = yes ]; then
	for line in $multiboot_new_cmds
	do
		cmd=${line%,*}
		file=${cmd##*/}
		archive=${line#*,}
		if [ -n "$DIRECTBOOT_BIN_DIR" ] && \
		    [ -f $DIRECTBOOT_BIN_DIR/$file ]; then
			cp $DIRECTBOOT_BIN_DIR/$file /tmp/bfubin/
		else
			if [ $root_is_xpv = yes ] ||
			    [ $root_is_directboot = yes ] &&
			    [ $archive_type = multiboot ]; then
				cp $root/$cmd /tmp/bfubin/
				have_new_bootadm=yes
			elif [ $archive_type = directboot ] || \
			    [ $archive_type = xpv ]; then
				DBOOT_TMPDIR=/tmp/dboot.$$
				trap "rm -rf $DBOOT_TMPDIR" EXIT
				OLD_PWD=$(pwd)
				rm -rf $DBOOT_TMPDIR
				mkdir $DBOOT_TMPDIR
				cd $DBOOT_TMPDIR
				$ZCAT $cpiodir/${archive}$ZFIX | \
				    cpio -id "$cmd" 2>/dev/null
				if [ -x $cmd ]; then
					cp $cmd /tmp/bfubin/
					have_new_bootadm=yes
				fi
				cd $OLD_PWD
				rm -rf $DBOOT_TMPDIR
				trap - EXIT
			fi
		fi

		#
		# If all else fails, grab the local version
		#
		if [ ! -x /tmp/bfubin/$file ]; then
			[ -x /$cmd ] && cp /$cmd /tmp/bfubin
		fi
	done
	if [ $archive_type = directboot ] && [ $root_is_directboot = yes ]; then
		cleanup_eeprom_console
	fi
fi

multiboot_cmds="
	/sbin/biosdev
	/sbin/installgrub
"
copying_mboot_cmds=no
if [ $multi_or_direct = yes ]; then
	for cmd in $multiboot_cmds
	do
		file=`basename $cmd`
		if [ -f $cmd ]; then
			cp $cmd /tmp/bfubin
		elif [ -n "$DIRECTBOOT_BIN_DIR" ] &&
		    [ -d $DIRECTBOOT_BIN_DIR ] &&
		    [ -x $DIRECTBOOT_BIN_DIR/$file ]; then
			cp $DIRECTBOOT_BIN_DIR/$file /tmp/bfubin/
		else
			if [ ! -d $MULTIBOOT_BIN_DIR ]; then
				echo "$MULTIBOOT_BIN_DIR: not found"
			elif [ ! -f $MULTIBOOT_BIN_DIR/$file ]; then
				echo "$MULTIBOOT_BIN_DIR/$file: not found"
			fi
			if [ $copying_mboot_cmds = no ]; then
				echo "installing files from $MULTIBOOT_BIN_DIR"
				copying_mboot_cmds=yes
			fi
			cp $MULTIBOOT_BIN_DIR/$file /tmp/bfubin
		fi

	done
fi

#
# If available, use ldd to determine which libraries bfu depends on.
# Otherwise, just make an educated guess.
#
if [ -x /usr/bin/ldd ]; then
	bfulib="`ldd /tmp/bfubin/* | nawk '$3 ~ /lib/ { print $3 }' | sort -u`"
else
	bfulib="
		/lib/libc.so.1
		/lib/libm.so.2
		/lib/libdoor.so.1
		/lib/libm.so.2
		/lib/libmd.so.1
		/lib/libmd5.so.1
		/lib/libnvpair.so.1
		/lib/libscf.so.1
		/lib/libuutil.so.1
		/usr/lib/libbsm.so.1
		/usr/lib/libc2.so
		/usr/lib/libdl.so.1
		/usr/lib/libelf.so.1
		/usr/lib/libkstat.so.1
		/usr/lib/libmapmalloc.so.1
		/usr/lib/libmp.so.1
		/usr/lib/libnsl.so.1
		/usr/lib/libpam.so.1
		/usr/lib/libsec.so.1
		/usr/lib/libsocket.so.1
		/usr/lib/libtecla.so.1
	"
fi

# add dlopen()'ed stuff
bfulib="
	$bfulib
	/lib/ld.so.1
	/usr/lib/nss_*
"

# add libc_psr.so.1, if available and not empty
if [ -s /platform/`uname -i`/lib/libc_psr.so.1 ]; then
	bfulib="
		$bfulib
		/platform/`uname -i`/lib/libc_psr.so.1
	"
fi

rm -rf /tmp/bfulib /tmp/bl
mkdir /tmp/bfulib /tmp/bl

#
# Create 64 bit directory structure and determine 64 bit arch name.
#
if [ -h /usr/lib/64 ]
then
	link=`ls -dl /usr/lib/64  | awk '{print $NF}'`
	ln -s $link /tmp/bfulib/64
	ln -s $link /tmp/bl/64
	mkdir /tmp/bfulib/$link /tmp/bl/$link
	bfulib="$bfulib /usr/lib/64/nss_*"
	#
	# Copy libraries to proper directories
	#
	for lib in $bfulib
	do
		case $lib in
		*/64/* | */$link/*)
			cp $lib /tmp/bfulib/64;;
		*)
			cp $lib /tmp/bfulib;;
		esac
	done
	#
	# Private 64 bit runtime linker.
	#
	cp /lib/64/ld.so.1 /tmp/bfulib/64/bf.1
	cp /lib/64/ld.so.1 /tmp/bl/64/bf.1
else
	cp $bfulib /tmp/bfulib
fi
cp /lib/ld.so.1 /tmp/bfulib/bf.1	# bfu's private runtime linker
cp /lib/ld.so.1 /tmp/bl/bf.1

${BFULD-$GATE/public/bin/$bfu_isa/bfuld} /tmp/bfubin/* || fail "bfuld failed"

for x in $bfuscr
do
	sed -e 's/\/usr\/bin\//\/tmp\/bfubin\//g' \
	    -e 's/\/bin\//\/tmp\/bfubin\//g' < $x > /tmp/bfubin/`basename $x`
	chmod +x /tmp/bfubin/`basename $x`
done

#
# scripts used together with multiboot
#
multiboot_scr="
	/boot/solaris/bin/create_ramdisk
	/boot/solaris/bin/create_diskmap
	/boot/solaris/bin/root_archive
"

if [ $multi_or_direct = yes ]; then
	for cmd in $multiboot_scr
	do
		file=`basename $cmd`
		if [ -f $cmd ]; then
			cp $cmd /tmp/bfubin
		else
			if [ ! -d $MULTIBOOT_BIN_DIR ]; then
				echo "$MULTIBOOT_BIN_DIR: not found"
				fail ""
			fi

			if [ ! -f $MULTIBOOT_BIN_DIR/$file ]; then
				echo "$MULTIBOOT_BIN_DIR/$file: not found"
				fail ""
			fi
			echo "copying $file from $MULTIBOOT_BIN_DIR"
			cp $MULTIBOOT_BIN_DIR/$file /tmp/bfubin
		fi

		#
		# We do two substitutions here to replace references to
		# both /usr/bin/ and /bin/ with /tmp/bfubin/
		#
		mv /tmp/bfubin/${file} /tmp/bfubin/${file}-
		sed -e 's/\/usr\/bin\//\/tmp\/bfubin\//g' \
		    -e 's/\/bin\//\/tmp\/bfubin\//g' \
		    < /tmp/bfubin/${file}- > /tmp/bfubin/${file}
		chmod +x /tmp/bfubin/${file}
	done
fi

#
# For directboot archives, /boot/platform/i86pc/kernel/unix will be
# overwritten, which could cause a mis-match with the failsafe
# miniroot.  Extract unix from the miniroot and save it off for now.
#
if [ $archive_type = directboot ] && [ $diskless = no ]; then
	if gunzip -c "$root/boot/x86.miniroot-safe" \
	    >/tmp/bfubin/miniroot-unzipped; then
		lofifile=/tmp/bfubin/miniroot-unzipped
	else
		# Shouldn't happen?  See if someone already unzipped it.
		lofifile="$root/boot/x86.miniroot-safe"
	fi
	lofidev=`lofiadm -a $lofifile 2>/dev/null`
	if [ -n "$lofidev" ]; then
		mkdir /tmp/bfubin/mnt
		mount -r $lofidev /tmp/bfubin/mnt

		unix=/tmp/bfubin/mnt/boot/platform/i86pc/kernel/unix
		if [ -f $unix ]; then
			cp $unix /tmp/bfubin/unix
			failsafe_type=directboot
		elif [ -f /tmp/bfubin/mnt/platform/i86pc/multiboot ]
		then
			failsafe_type=multiboot
		fi

		umount /tmp/bfubin/mnt
		rmdir /tmp/bfubin/mnt
		lofiadm -d $lofidev
	fi
	rm -f /tmp/bfubin/miniroot-unzipped
fi

create_datalink_conf()
{
	# /etc/datalink.conf needs to be populated.
	drivers="bge rge xge"
	conf=$rootprefix/etc/datalink.conf

	if [ ! -f $conf ]; then
		# nothing to do if we bfu'ed from an archive that doesn't
		# provide /etc/datalink.conf
		return
	fi

	ls -1 $rootprefix/etc | egrep -e '^hostname.|^hostname6.|^dhcp.' | \
	    cut -d . -f2 | sort -u > /tmp/ifnames.$$

	for driver in $drivers
	do
		grep $driver /tmp/ifnames.$$ | \
		while read ifname
		do
			devnum=`echo $ifname | sed "s/$driver//g"`
			if [ "$driver$devnum" != $ifname -o \
			    -n "`echo $devnum | tr -d '[0-9]'`" ]; then
				echo "skipping invalid interface $ifname"
				continue
			fi

			vid=`expr $devnum / 1000`
			inst=`expr $devnum % 1000`

			awk '{ print $1 }' $conf | grep $ifname > /dev/null
			if [ $? -ne 0 ]; then 
				# An entry for that interface does not exist
				printf \
				    "$ifname\t$driver$inst\t0\t$vid\n" \
				    >> $conf
			fi
		done
	done

	rm -f /tmp/ifnames.$$
}

revert_aggregation_conf()
{
	aggrconf=$rootprefix/etc/aggregation.conf
	nawk '
		/^[ \t]*#/ || /^[ \t]*$/ || $4 ~ "/0" {
			print;
			next;
		}

		{
			OFS="\t";
			gsub(/[^,]*/, "&/0", $4);
			print;
		}' $aggrconf > $aggrconf.bfutmp
	mv -f $aggrconf.bfutmp $aggrconf
}

remove_initd_links()
{
	# If we're delivering a new version of an existing /etc/init.d script,
	# remove all hard links to the existing file in /etc/rc?.d whose
	# names begin with [SK][0-9][0-9].  Additionally, in case an S or K
	# file was previously delivered as a symbolic link or the hard link
	# was broken, remove any file in /etc/rc?.d whose name is
	# [SK][0-9][0-9] followed by the basename of the file we're going
	# to update in /etc/init.d.

	print "Removing init.d links ... \c"
	scripts=`$ZCAT $cpiodir/generic.root$ZFIX |
		cpio -it 2>/dev/null | grep '^etc/init\.d/'`
	if [ -n "$scripts" ]; then
		inodes=`ls -li $scripts 2>/dev/null | \
			nawk '{ print "-inum " $1 " -o " }'`
		names=`ls -1 $scripts 2>/dev/null | \
			nawk -F/ '{ print "-name [SK][0-9][0-9]" $NF }'`
		find etc/rc?.d \( $inodes $names \) -print | xargs rm -f
	fi
	print "done."
}

#
# Remove the old 5.005_03 version of perl.
#
remove_perl_500503()
{
	# Packages to remove.
	typeset -r perl_pkgs='SUNWopl5m SUNWopl5p SUNWopl5u'
	typeset pkg

	#
	# First, attempt to remove the packages cleanly if possible.
	#
	printf 'Removing perl 5.005_03 packages'
	for pkg in $perl_pkgs
	do
		if pkginfo $pkgroot -q $pkg; then
			printf ' %s' $pkg
			pkgrm $pkgroot -n $pkg >/dev/null 2>&1
		fi
	done
	printf '\n'

	#
	# In case that didn't work, do it manually.
	#
	printf 'Removing perl 5.005_03 from %s/var/sadm/install/contents' \
	    $rootprefix
	for pkg in $PKGS
	do
		printf ' %s' $pkg
		if [ -d $rootprefix/var/sadm/pkg/$pkg ]; then
			rm -rf $rootprefix/var/sadm/pkg/$pkg
			grep -vw $pkg $rootprefix/var/sadm/install/contents > \
			    /tmp/contents.$$
			cp /tmp/contents.$$ /var/sadm/install/contents.$$
			rm /tmp/contents.$$
		fi
	done
	printf '\n'

	#
	# Remove any remaining 5.005_03 files,
	#
	printf 'Removing perl 5.005_03 from %s/perl5\n' $usr

	# Directories.
	rm -rf $usr/perl5/5.00503
	rm -rf $usr/perl5/site_perl/5.005
}

#
# Remove Wildcat (aka Sun Fire Link)
#
remove_eof_wildcat()
{
	# Packages to remove
	typeset -r wildcat_pkgs='SUNWwrsa SUNWwrsd SUNWwrsu SUNWwrsm'
	typeset pkg

	#
	# First, attempt to remove the packages cleanly if possible.
	# Use a custom "admin" file to specify that removal scripts
	# in the packages being removed should be run even if they
	# will run as root.
	#
	typeset -r admfile='/tmp/wcat_eof.$$'
	echo "action=nocheck" > $admfile

	printf 'Removing Wildcat packages...'
	for pkg in $wildcat_pkgs
	do
		if pkginfo $pkgroot -q $pkg; then
			printf ' %s' $pkg
			pkgrm $pkgroot -n -a $admfile $pkg >/dev/null 2>&1
		fi
	done
	printf '\n'

	#
	# In case that didn't work, do it manually.
	#
	printf 'Removing Wildcat from %s/var/sadm/install/contents...' \
	    $rootprefix
	for pkg in $wildcat_pkgs
	do
		printf ' %s' $pkg
		if [ -d $rootprefix/var/sadm/pkg/$pkg ]; then
			rm -rf $rootprefix/var/sadm/pkg/$pkg
			grep -vw $pkg $rootprefix/var/sadm/install/contents > \
			    /tmp/contents.$$
			cp /tmp/contents.$$ \
			    $rootprefix/var/sadm/install/contents
			rm /tmp/contents.$$
		fi
	done
	printf '\n'

	#
	# Cleanup any remaining Wildcat files, symlinks, and directories.
	#
	rm -f $usr/platform/sun4u/include/sys/wci_common.h
	rm -f $usr/platform/sun4u/include/sys/wci_regs.h
	rm -f $usr/platform/sun4u/include/sys/wci_offsets.h
	rm -f $usr/platform/sun4u/include/sys/wci_cmmu.h
	rm -f $usr/platform/sun4u/include/sys/wrsm.h
	rm -f $usr/platform/sun4u/include/sys/wrsm_common.h
	rm -f $usr/platform/sun4u/include/sys/wrsm_config.h
	rm -f $usr/platform/sun4u/include/sys/wrsm_types.h
	rm -f $usr/platform/sun4u/include/sys/wrsm_plat.h
	rm -f $usr/platform/sun4u/include/sys/wrsm_plugin.h
	rm -f $usr/platform/sun4u/include/sys/wrsmconf.h

	rm -f $usr/platform/sun4u/lib/mdb/kvm/sparcv9/wrsm.so
	rm -f $usr/platform/sun4u/lib/mdb/kvm/sparcv9/wrsmd.so

	rm -f $rootprefix/platform/SUNW,Sun-Fire-15000/kernel/misc/sparcv9/gptwo_wci

	rm -f $rootprefix/platform/sun4u/kernel/kmdb/sparcv9/wrsm
	rm -f $rootprefix/platform/sun4u/kernel/kmdb/sparcv9/wrsmd

	rm -f $admfile
}

#
# Remove ASET
#
remove_eof_aset()
{
	# Packages to remove
	typeset -r aset_pkgs='SUNWast'
	typeset pkg

	printf 'Removing ASET... '

	#
	# First, attempt to remove the packages cleanly if possible.
	#
	for pkg in $aset_pkgs
	do
		if pkginfo $pkgroot -q $pkg; then
			printf ' %s' $pkg
			pkgrm $pkgroot -n $pkg >/dev/null 2>&1
		fi
	done
	printf '\n'

	#
	# In case that didn't work, do it manually.
	# Remove ASET from $rootprefix/var/sadm/install/contents
	#
	for pkg in $aset_pkgs
	do
		if [ -d $rootprefix/var/sadm/pkg/$pkg ]; then
			rm -rf $rootprefix/var/sadm/pkg/$pkg
			grep -vw $pkg $rootprefix/var/sadm/install/contents > \
			    /tmp/contents.$$
			cp /tmp/contents.$$ $rootprefix/var/sadm/install/contents.$$
			rm /tmp/contents.$$
		fi
	done

	#
	# Cleanup any remaining ASET files, symlinks, and directories.
	#
	rm -rf $usr/aset
}

#
# Remove BIND 8 named server/tools packages
#
remove_eof_bind8()
{
	# Packages to remove
	typeset -r bind8_pkg='SUNWinamd'
	typeset pkg

	printf 'Removing BIND 8 named server/tools... '

	#
	# We cann't pkgrm SUNWinamd at this time as the BIND 9 binaries are
	# already in /usr/sbin.
	# Remove BIND 8 packages from $rootprefix/var/sadm/install/contents
	#
	for pkg in $bind8_pkgs
	do
		if [ -d $rootprefix/var/sadm/pkg/$pkg ]; then
			rm -rf $rootprefix/var/sadm/pkg/$pkg
			grep -vw $pkg $rootprefix/var/sadm/install/contents > \
			    /tmp/contents.$$
			cp /tmp/contents.$$ /var/sadm/install/contents.$$
			rm /tmp/contents.$$
		fi
	done

	#
	# Cleanup any BIND 8 specific files, symlinks.
	#

	# files and symlinks.
	rm -f $usr/sbin/named-xfer
	rm -f $usr/lib/nslookup.help
	rm -f $usr/sbin/dnskeygen
	rm -f $usr/sbin/named-bootconf
	rm -f $usr/sbin/nstest
	rm -rf $rootprefix/var/run/ndc.d
	printf 'done.\n'
}

#
# Remove the 5.8.3 version of perl.
#
remove_perl_583()
{
	#
	# Copy perl 5.8.3 into the new 5.8.4 locations.  This will preserve
	# any add-on modules that might have been installed, and any 5.8.3
	# core files that get copied over will be replaced by the new 5.8.4
	# versions when the cpio archives are subsequently extracted.
	#
	printf 'Preserving user-installed perl modules...\n'
	mkdir -p $usr/perl5/5.8.4
	cp -rp $usr/perl5/5.8.3/* \
	    $usr/perl5/5.8.4
	mkdir -p $usr/perl5/site_perl/5.8.4
	cp -rp $usr/perl5/site_perl/5.8.3/* \
	    $usr/perl5/site_perl/5.8.4
	mkdir -p $usr/perl5/vendor_perl/5.8.4
	cp -rp $usr/perl5/vendor_perl/5.8.3/* \
	    $usr/perl5/vendor_perl/5.8.4

	#
	# Update the #! lines in any scripts in /usr/perl5/5.8.4/bin to refer
	# to 5.8.4 instead of 5.8.3.  Take care to edit only scripts.
	#
	typeset bindir="$usr/perl5/5.8.4/bin"
	typeset script
	for script in $(ls $bindir); do
		script="$bindir/$script"
		if [[ $script = "$usr/perl5/5.8.4/bin/perl5.8.3" ]]; then
			rm -f $script
		elif file $script | \
		    egrep -s 'executable .*perl .*script'; then
			sed -e \
			    's!/usr/perl5/5.8.3/bin/perl!/usr/perl5/5.8.4/bin/perl!g' \
			    < $script > $script.tmp
			mv -f $script.tmp $script
		fi
	done

	#
	# Packages to remove.
	#
	typeset -r perl_pkgs='SUNWperl583man SUNWperl583usr SUNWperl583root'

	#
	# First, attempt to remove the packages cleanly if possible.
	#
	typeset pkg
	printf 'Removing perl 5.8.3 packages'
	for pkg in $perl_pkgs
	do
		if pkginfo $pkgroot -q $pkg; then
			printf ' %s' $pkg
			pkgrm $pkgroot -n $pkg >/dev/null 2>&1
		fi
	done
	printf '\n'

	#
	# In case that didn't work, do it manually.
	#
	printf 'Removing perl 5.8.3 from %s/var/sadm/install/contents' \
	    $rootprefix
	for pkg in $PKGS
	do
		printf ' %s' $pkg
		if [ -d $rootprefix/var/sadm/pkg/$pkg ]; then
			rm -rf $rootprefix/var/sadm/pkg/$pkg
			grep -vw $pkg $rootprefix/var/sadm/install/contents > \
			    /tmp/contents.$$
			cp /tmp/contents.$$ /var/sadm/install/contents.$$
			rm /tmp/contents.$$
		fi
	done
	printf '\n'

	#
	# Remove any remaining 5.8.3 files,
	# and fix up the symlinks if necessary.
	#
	printf 'Removing perl 5.8.3 from %s/perl5\n' $usr

	# Directories.
	rm -rf $usr/perl5/5.8.3
	rm -rf $usr/perl5/site_perl/5.8.3
	rm -rf $usr/perl5/vendor_perl/5.8.3

	# bin symlink.
	rm -f $usr/perl5/bin
	ln -s ./5.8.4/bin $usr/perl5/bin

	# pod symlink.
	rm -f $usr/perl5/pod
	ln -s ./5.8.4/lib/pod $usr/perl5/pod

	#
	# man symlink.  In earlier S10 builds the man symlink mistakenly points
	# to the 5.6.1 manpages, instead of 5.8.3.  Fix to point to 5.8.4.
	#
	rm -f $usr/perl5/man
	ln -s ./5.8.4/man $usr/perl5/man

	# Symlink /bin/perl to 5.8.4.
	rm -f $usr/bin/perl
	ln -s ../perl5/5.8.4/bin/perl $usr/bin/perl
}

#
# Remove FNS/XFN packages
#
remove_eof_fns()
{
	# Packages to remove
	typeset -r fns_pkgs='SUNWfnx5x SUNWfnsx5 SUNWfnsx SUNWfns'
	typeset pkg

	printf 'Removing FNS/XFN ... '

	#
	# First, attempt to remove the packages cleanly if possible.
	#
	for pkg in $fns_pkgs
	do
		if pkginfo $pkgroot -q $pkg; then
			printf ' %s' $pkg
			pkgrm $pkgroot -n $pkg >/dev/null 2>&1
		fi
	done
	printf '\n'

	#
	# In case that didn't work, do it manually.
	# Remove FNS/XFN from $rootprefix/var/sadm/install/contents
	#
	for pkg in $fns_pkgs
	do
		if [ -d $rootprefix/var/sadm/pkg/$pkg ]; then
			rm -rf $rootprefix/var/sadm/pkg/$pkg
			grep -vw $pkg $rootprefix/var/sadm/install/contents > \
			    /tmp/contents.$$
			cp /tmp/contents.$$ $rootprefix/var/sadm/install/contents.$$
			rm /tmp/contents.$$
		fi
	done

	#
	# Cleanup if any remaining FNS/XFN files, symlinks, and directories.
	#

	# directories.
	rm -rf $rootprefix/etc/fn
	rm -rf $usr/include/xfn
	rm -rf $usr/lib/fn
	rm -rf $rootprefix/var/fn

	# files and symlinks.
	rm -f $rootprefix/etc/fn.conf
	rm -f $usr/bin/fnattr
	rm -f $usr/bin/fnbind
	rm -f $usr/bin/fncreate_printer
	rm -f $usr/bin/fnlist
	rm -f $usr/bin/fnlookup
	rm -f $usr/bin/fnrename
	rm -f $usr/bin/fnsearch
	rm -f $usr/bin/fnunbind
	rm -f $usr/sbin/fncheck
	rm -f $usr/sbin/fncopy
	rm -f $usr/sbin/fncreate
	rm -f $usr/sbin/fncreate_fs
	rm -f $usr/sbin/fndestroy
	rm -f $usr/sbin/fnselect
	rm -f $usr/sbin/fnsypd
	rm -f $usr/lib/libfn_p.so
	rm -f $usr/lib/libfn_p.so.1
	rm -f $usr/lib/libfn_spf.so
	rm -f $usr/lib/libfn_spf.so.1
	rm -f $usr/lib/libxfn.so
	rm -f $usr/lib/libxfn.so.1
	rm -f $usr/lib/libxfn.so.2
	rm -f $usr/lib/sparcv9/libfn_p.so
	rm -f $usr/lib/sparcv9/libfn_p.so.1
	rm -f $usr/lib/sparcv9/libfn_spf.so
	rm -f $usr/lib/sparcv9/libfn_spf.so.1
	rm -f $usr/lib/sparcv9/libxfn.so
	rm -f $usr/lib/sparcv9/libxfn.so.1
	rm -f $usr/lib/sparcv9/libxfn.so.2
}

remove_eof_face() {
	# Packages to remove
	typeset -r face_pkgs='SUNWfac'
	typeset pkg

	printf 'Removing AT&T FACE... '

	#
	# First, attempt to remove the packages cleanly if possible.
	#
	for pkg in $face_pkgs
	do
		if pkginfo $pkgroot -q $pkg; then
			printf ' %s' $pkg
			pkgrm $pkgroot -n $pkg >/dev/null 2>&1
		fi
	done
	printf '\n'

	#
	# In case that didn't work, do it manually.
	# Remove FACE from $rootprefix/var/sadm/install/contents
	#
	for pkg in $face_pkgs
	do
		if [ -d $rootprefix/var/sadm/pkg/$pkg ]; then
			rm -rf $rootprefix/var/sadm/pkg/$pkg
			grep -vw $pkg $rootprefix/var/sadm/install/contents > \
			    /tmp/contents.$$
			cp /tmp/contents.$$ $rootprefix/var/sadm/install/contents.$$
			rm /tmp/contents.$$
		fi
	done

	#
	# Cleanup any remaining FACE files, symlinks, and directories.
	#
	rm -rf $usr/oasys
	rm -rf $usr/vmsys
}

remove_eof_dmi() {
	# Packages to remove
	typeset -r dmi_pkgs='SUNWsadmi'
	typeset pkg

	printf 'Removing DMI... '

	#
	# First, attempt to remove the packages cleanly if possible.
	#
	for pkg in $dmi_pkgs
	do
		if pkginfo $pkgroot -q $pkg; then
			printf ' %s' $pkg
			pkgrm $pkgroot -n $pkg >/dev/null 2>&1
		fi
	done
	printf '\n'

	#
	# In case that didn't work, do it manually.
	# Remove DMI from $rootprefix/var/sadm/install/contents
	#
	for pkg in $dmi_pkgs
	do
		if [ -d $rootprefix/var/sadm/pkg/$pkg ]; then
			rm -rf $rootprefix/var/sadm/pkg/$pkg
			grep -vw $pkg $rootprefix/var/sadm/install/contents > \
			    /tmp/contents.$$
			cp /tmp/contents.$$ $rootprefix/var/sadm/install/contents.$$
			rm /tmp/contents.$$
		fi
	done

	#
	# Cleanup any remaining DMI files, symlinks, and directories.
	#
	rm -rf $usr/lib/dmi
	rm -rf $rootprefix/var/dmi
	rm -rf $rootprefix/etc/dmi
	rm -f $usr/lib/libdmi.so
	rm -f $usr/lib/libdmici.so
	rm -f $usr/lib/libdmimi.so
	rm -f $usr/lib/libdmi.so.1
	rm -f $usr/lib/libdmici.so.1
	rm -f $usr/lib/libdmimi.so.1
	rm -f $usr/lib/sparcv9/libdmi.so
	rm -f $usr/lib/sparcv9/libdmici.so
	rm -f $usr/lib/sparcv9/libdmimi.so
	rm -f $usr/lib/sparcv9/libdmi.so.1
	rm -f $usr/lib/sparcv9/libdmici.so.1
	rm -f $usr/lib/sparcv9/libdmimi.so.1
	rm -f $usr/lib/amd64/libdmi.so
	rm -f $usr/lib/amd64/libdmici.so
	rm -f $usr/lib/amd64/libdmimi.so
	rm -f $usr/lib/amd64/libdmi.so.1
	rm -f $usr/lib/amd64/libdmici.so.1
	rm -f $usr/lib/amd64/libdmimi.so.1
	rm -f $usr/sbin/dmi_cmd
	rm -f $usr/sbin/dmiget
	rm -f $rootprefix/etc/init.d/init.dmi
	rm -f $rootprefix/etc/rc0.d/K07dmi
	rm -f $rootprefix/etc/rc1.d/K07dmi
	rm -f $rootprefix/etc/rc2.d/K07dmi
	rm -f $rootprefix/etc/rcS.d/K07dmi
	rm -f $rootprefix/etc/rc3.d/S77dmi
}

#
# Remove vold
#
remove_eof_vold()
{
	printf 'Removing vold... '

	rm -rf $usr/lib/vold
	rm -rf $usr/lib/rmmount
	rm -f $usr/lib/fs/hsfs/ident_hsfs.so.1
	rm -f $usr/lib/fs/pcfs/ident_pcfs.so.1
	rm -f $usr/lib/fs/udfs/ident_udfs.so.1
	rm -f $usr/lib/fs/ufs/ident_ufs.so.1
	rm -f $usr/sbin/vold
	rm -f $usr/kernel/drv/vol
	rm -f $usr/kernel/drv/amd64/vol
	rm -f $usr/kernel/drv/sparcv9/vol
	rm -f $usr/include/rmmount.h
	rm -f $usr/include/vol.h
	rm -f $rootprefix/etc/vold.conf
	rm -f $rootprefix/etc/rmmount.conf

	printf '\n'
}

#
# Remove the obsolete Mobile IP packages
#
remove_eof_mobileip() {
	typeset -r mip_pkgs='SUNWmipr SUNWmipu'
	typeset pkg

	printf 'Removing Mobile IP... '

	for pkg in $mip_pkgs
	do
		if pkginfo $pkgroot -q $pkg; then
			printf ' %s' $pkg
			pkgrm $pkgroot -n $pkg >/dev/null 2>&1
		fi
	done

	# In case that did not work, do it manually.
	if [[ -d $rootprefix/var/sadm/pkg/SUNWmipr ]]; then
		rm -f "$rootprefix/etc/inet/mipagent.conf-sample"
		rm -f "$rootprefix/etc/inet/mipagent.conf.fa-sample"
		rm -f "$rootprefix/etc/inet/mipagent.conf.ha-sample"
		rm -f "$rootprefix/etc/init.d/mipagent"
		rm -f "$rootprefix/etc/rc0.d/K06mipagent"
		rm -f "$rootprefix/etc/rc1.d/K06mipagent"
		rm -f "$rootprefix/etc/rc2.d/K06mipagent"
		rm -f "$rootprefix/etc/rc3.d/S80mipagent"
		rm -f "$rootprefix/etc/rcS.d/K06mipagent"
		rm -f "$rootprefix/etc/snmp/conf/mipagent.acl"
		rm -f "$rootprefix/etc/snmp/conf/mipagent.reg"
	fi
	if [[ -d $rootprefix/var/sadm/pkg/SUNWmipu ]]; then
		rm -f "$rootprefix/usr/lib/inet/mipagent"
		rm -f "$rootprefix/usr/sbin/mipagentconfig"
		rm -f "$rootprefix/usr/sbin/mipagentstat"
	fi
	printf '\n'
}

remove_properties() {

	#
	# Remove obsolete smartii setprop from bootenv.rc
	#
	srcbootenvrc=$root/boot/solaris/bootenv.rc
	tmpbootenvrc=/tmp/tmp.bootenvrc.$$

	# Don't touch bootenv.rc unless it contains obsolete property
	egrep -s 'target-driver-for-smartii' $srcbootenvrc 2>/dev/null
	res=$?
	if [ -f $srcbootenvrc -a $res -eq 0 ]; then
		egrep -v "target-driver-for-smartii"\
			$srcbootenvrc > $tmpbootenvrc 2>/dev/null
		cp $tmpbootenvrc $srcbootenvrc
	fi
	rm -f $tmpbootenvrc
}

rbac_cleanup()
{
# This is a copy of the RBAC portions of the SUNWcsr postinstall
# We need to ensure that the RBAC profiles are self-consistent
# as refinements are made that add granularity to the profiles

	print "Cleaning up old RBAC profiles... \c"
	auth_attr=$rootprefix/etc/security/auth_attr
	exec_attr=$rootprefix/etc/security/exec_attr

	if [ -f $auth_attr ]; then
		sed '/^solaris\.\*/d' $auth_attr > /tmp/a.$$
		cp /tmp/a.$$ $auth_attr
		rm -f /tmp/a.$$
	fi

	if [ -f $exec_attr ]; then
		sed -e '/^Network Security.*sbin\/ipsec.*/ D' \
		-e '/^Network Security.*sbin\/ike.*/ D' \
		-e '/^Network Security.*inet\/in\.iked.*/ D' \
		-e '/^Network Security.*inet\/cert.*/ D' $exec_attr > /tmp/e.$$
		cp /tmp/e.$$ $exec_attr
		rm -f /tmp/e.$$
	fi
	print "\n"
}

enable_crypto_unlimited()
{
# This is a "copy" of the SUNWcry* postinstall scripts.
# We enable the encryption kit aes256, arcfour2048, and blowfish448 modules.
# This is needed to ensure bfu users continue to have the full strength of
# cryptographic algorithms they use.

	print "Simulating SUNWcry* installation...\c"
	kcfconf=$rootprefix/etc/crypto/kcf.conf
	ipsecalgs=$rootprefix/etc/inet/ipsecalgs

	cp $kcfconf ${kcfconf}.tmp

	sed -e 's/^aes:/aes256:/' -e 's/^blowfish:/blowfish448:/' -e \
	    's/^arcfour:/arcfour2048:/'\
        	$kcfconf > ${kcfconf}.tmp

	mv -f ${kcfconf}.tmp $kcfconf

	cp $ipsecalgs ${ipsecalgs}.tmp

	sed -e 's/_CBC|128\/32-128,8/_CBC|128\/32-448,8/' \
	    -e 's/AES_CBC|128|/AES_CBC|128\/128-256,64|/' \
	    $ipsecalgs > ${ipsecalgs}.tmp

	mv -f ${ipsecalgs}.tmp $ipsecalgs

	# Since we do that for the kernel we do it for userland as well.

	# "Clone" the policy for pkcs11_softtoken to the encryption kit version
	# and "disable" pkcs11_softoken.

	pkcs11conf=$rootprefix/etc/crypto/pkcs11.conf

	cp $pkcs11conf ${pkcs11conf}.tmp

	sed 's/pkcs11_softtoken\.so/pkcs11_softtoken_extra.so/' \
        	$pkcs11conf > ${pkcs11conf}.tmp

	mv -f ${pkcs11conf}.tmp $pkcs11conf
	print "\n"

}

#
# Add metaslot configuration to pkcs11.conf if it doesn't already exist
#
enable_crypto_metaslot()
{
	pkcs11conf=$rootprefix/etc/crypto/pkcs11.conf
	egrep '^metaslot' ${pkcs11conf} > /dev/null 2>& 1
	if [ $? != 0 ] ; then
		print "Adding cryptographic framework's meta slot feature"
		cp $pkcs11conf ${pkcs11conf}.tmp
		export metaslot_config=\
"metaslot:metaslot_status=enabled;metaslot_auto_key_migrate=enabled;"\
"metaslot_token=Sun Software PKCS#11 softtoken;"\
"metaslot_slot=Sun Crypto Softtoken"
		nawk '/^# End SUNWcsr/ \
			{ print ENVIRON["metaslot_config"] } \
			{ print } \
		' ${pkcs11conf}	> ${pkcs11conf}.tmp
		mv -f ${pkcs11conf}.tmp $pkcs11conf
		print "\n"
	fi
}

cleanup_kerberos_mechanisms()
{
#
# This checks to see if the old 'gl' and 'do' directories
# for the Kerberos GSS-API mechanisms can be deleted.
# If the mechanism exists in /usr/lib/gss, then the old
# subdirs may be deleted.
#
	print "Cleaning up old Kerberos GSS-API mechanisms...\c"

	kerneldir=kernel/misc/kgss
	kerneldir_sparc=kernel/misc/kgss/sparcv9

	newmech=no;
	if [ -f $usr/lib/gss/mech_krb5.so.1 ]; then
		#
		# There is a mech  in the "new" location, so
		# the old stuff can be deleted.
		#
		if [ -d $usr/lib/gss/gl ]; then
			rm -rf $usr/lib/gss/gl
		fi
		if [ -d $usr/lib/gss/do ]; then
			rm -rf $usr/lib/gss/do
		fi
		newmech=yes;
	fi
	if [ -f $usr/lib/sparcv9/gss/mech_krb5.so.1 ]; then
		if [ -d $usr/lib/sparcv9/gss/gl ]; then
			rm -rf $usr/lib/sparcv9/gss/gl
		fi
		if [ -d $usr/lib/sparcv9/gss/do ]; then
			rm -rf $usr/lib/sparcv9/gss/do
		fi
	fi
	#
	# Cleanup kernel mechanisms from default location
	#
	if [ -f $rootprefix/$kerneldir/kmech_krb5 ]; then
		if [ -f $rootprefix/$kerneldir/gl_kmech_krb5 ]; then
			rm -f $rootprefix/$kerneldir/gl_kmech_krb5
		fi
		if [ -f $rootprefix/$kerneldir/do_kmech_krb5 ]; then
			rm -f $rootprefix/$kerneldir/do_kmech_krb5
		fi
	fi
	#
	# For SPARC, cleanup from 2 locations.
	#
	# 1.  /kernel/misc/kgss/sparcv9
	#
	if [ -f $rootprefix/$kerneldir_sparc/kmech_krb5 ]; then
		if [ -f $rootprefix/$kerneldir_sparc/gl_kmech_krb5 ]; then
			rm -f $rootprefix/$kerneldir_sparc/gl_kmech_krb5
		fi
		if [ -f $rootprefix/$kerneldir_sparc/do_kmech_krb5 ]; then
			rm -f $rootprefix/$kerneldir_sparc/do_kmech_krb5
		fi
	fi
	#
	# 2.  /platform/sun4u/kernel/misc/kgss/sparcv9
	#
	kerneldir_sparc=platform/$karch/$kerneldir_sparc
	if [ -f $rootprefix/$kerneldir_sparc/kmech_krb5 ]; then
		if [ -f $rootprefix/$kerneldir_sparc/gl_kmech_krb5 ]; then
			rm -f $rootprefix/$kerneldir_sparc/gl_kmech_krb5
		fi
		if [ -f $rootprefix/$kerneldir_sparc/do_kmech_krb5 ]; then
			rm -f $rootprefix/$kerneldir_sparc/do_kmech_krb5
		fi
	fi
	#
	# Make sure the GSS mechanism configuration file is correct
	#
	if [ "$newmech" = "yes" ]; then
		gssmechconf=$rootprefix/etc/gss/mech

		sed -e 's/gl\/mech_krb5\.so/mech_krb5\.so/' \
		-e 's/do\/mech_krb5\.so/mech_krb5\.so/' \
		-e 's/gl_kmech_krb5/kmech_krb5/' \
		-e 's/do_kmech_krb5/kmech_krb5/'\
		$gssmechconf > ${gssmechconf}.tmp

		if [ $? -eq 0 ]; then
			mv -f ${gssmechconf}.tmp $gssmechconf
		else
			echo  "WARNING: update of $gssmechconf failed."
			return 1
		fi
	fi
	print "\n"
}

mpxiodisableno='^[ 	]*mpxio-disable[ 	]*=[ 	]*"no"[ 	]*;'
mpxiodisableyes='^[ 	]*mpxio-disable[ 	]*=[ 	]*"yes"[ 	]*;'

#
# fix up audit permissions
#
fix_up_audit()
{
	chmod 644 $root/etc/security/audit_control
	chmod 644 $root/etc/security/audit_user
}

#
# disable mpxio on fp(7D) ports using fp.conf
#
disable_mpxio_using_fpconf()
{
	conffile=$rootprefix/kernel/drv/fp.conf
	test -f $conffile || return
	egrep -s "$mpxiodisableyes" $conffile && return

	print "To preserve device names, disabled mpxio on fp(7D) ports by"

	if egrep -s "$mpxiodisableno" $conffile; then
		tmpfile=/tmp/fp.conf.$$
		sed "s/$mpxiodisableno/mpxio-disable=\"yes\";/" $conffile \
		    > $tmpfile
		cp $tmpfile $conffile
		rm -f $tmpfile
		print "changing the value of mpxio-disable to \"yes\" in" \
		  "$conffile"
	else
		echo 'mpxio-disable="yes";' >> $conffile
		print "adding mpxio-disable=\"yes\" entry to $conffile"
	fi
}

#
# enable mpxio in scsi_vhci
#
enable_mpxio_using_scsivhciconf()
{
	#
	# depending on whether the bfu restored the child's or parent's version
	# of scsi_vhci.conf file, we may already have the file with the change
	# we need in place. So make the change only if necessary.
	#

	conffile=$rootprefix/kernel/drv/scsi_vhci.conf
	egrep -s "$mpxiodisableno" $conffile && return

	print "To preserve device names, restored your current mpxio" \
	    "configuration by"

	if egrep -s "$mpxiodisableyes" $conffile; then
		tmpfile=/tmp/scsi_vhci.conf.$$
		sed "s/$mpxiodisableyes/mpxio-disable=\"no\";/" $conffile \
		    > $tmpfile
		cp $tmpfile $conffile
		rm -f $tmpfile
		print "changing the value of mpxio-disable to \"no\" in" \
		  "$conffile"
	else
		echo 'mpxio-disable="no";' >> $conffile
		print "adding mpxio-disable=\"no\" entry to $conffile"
	fi
}

#
# restore the pre-bfu MPxIO on/off setting to the post-bfued configuration
#
fixup_mpxio()
{
	conffile=$rootprefix/kernel/drv/scsi_vhci.conf
	parentconffile=$rootprefix/bfu.parent/kernel/drv/scsi_vhci.conf
	childconffile=$rootprefix/bfu.child/kernel/drv/scsi_vhci.conf
	ancestorconffile=$rootprefix/bfu.ancestor/kernel/drv/scsi_vhci.conf

	# if scsi_vhci.conf doesn't exist return
	test -f $conffile || return

	#
	# Determine the mpxio setting in the child. If the system was bfued
	# before and running with mpxio on by deafult bits, can't rely on the
	# mpxio-disable entry in the child's scsi_vhci.conf file as it may
	# contain stale left over entries.
	#
	mpxio_child=1
	if [ -f $ancestorconffile ]; then
		if egrep -s "$mpxiodisableyes" $ancestorconffile; then
			#
			# prior to the bfu the system was running with
			# mpxio off by default bits.
			#
			mpxio_child=0
			egrep -s "$mpxiodisableno" $childconffile && \
			    mpxio_child=1
		fi
	else
		egrep -s "$mpxiodisableyes" $childconffile && mpxio_child=0
	fi

	if egrep -s "$mpxiodisableyes" $parentconffile; then
		# these bits require explicit enabling of mpxio at in scsi_vhci
		if [ $mpxio_child -eq 1 ]; then
			egrep -s "$mpxiodisableyes" \
			    $rootprefix/kernel/drv/fp.conf || \
			    enable_mpxio_using_scsivhciconf
		fi
	else
		#
		# these bits have mpxio enabled by default in scsi_vhci.
		# if mpxio is disabled in the child, disable mpxio on all
		# fp(7D) ports using fp.conf.
		#
		[ $mpxio_child -eq 0 ] && disable_mpxio_using_fpconf
	fi
}


#
# Check to see if root in $1 has a mounted boot, and that
# it's mounted at the right place for bfu to handle it.
#
# Returns 0 (true) if bfu can handle the upgrade; fails if not
#

boot_is_upgradeable()
{
	ROOT=$1
	if [ "$ROOT" = "/" ] ; then ROOT=""; fi

        BOOTPARTDEV="$(grep -s -v '^#' ${ROOT}/etc/vfstab | \
	    grep "[ 	]/boot[ 	]*pcfs[ 	]" | \
	    awk '{print $1}')"

	# find out if, and where, boot is mounted

	if [ -n "$BOOTPARTDEV" ] ; then 
		if [ -n "$ROOT" ] ; then
		
			BOOTMNT=$(mount | grep "$BOOTPARTDEV" | \
			    awk '{print $1}')
		else
			BOOTMNT="/boot"
		fi
		if [ "$BOOTMNT" != ${ROOT}/boot ] ; then
			cat << BOOTMOUNTERR

${ROOT} refers to an x86 boot partition, but it's not mounted 
at ${ROOT}/boot.

BOOTMOUNTERR
			fail "Mount ${ROOT}s bootpart at ${ROOT}/boot.\n\n"
		fi
	fi

	return 0
}

# update the realmode boot programs at $1 (root) 
# from classic boot psm/stand/bootblks/ufs/i386/installboot.sh

install_boot_i386()
{
	PBOOT=$1
	BOOTBLK=$2
	DEVICE=$3
	if [ ! -f $PBOOT ]; then
		echo "$PBOOT: File not found"
		return 1
	fi
	if [ ! -f $BOOTBLK ]; then
		echo "$BOOTBLK: File not found"
		return 1
	fi
	if [ ! -c $DEVICE ]; then
		echo "$DEVICE: Not a character device"
		return 1
	fi
	if [ ! -w $DEVICE ]; then
		echo "$DEVICE: Not writeable"
		return 1
	fi

	# pboot at block 0, label at blocks 1 and 2, bootblk from block 3 on
	dd if=$PBOOT of=$DEVICE bs=1b count=1 conv=sync >/dev/null 2>&1

	dd if=$BOOTBLK of=$DEVICE bs=1b oseek=3 conv=sync >/dev/null 2>&1

	return 0
}

update_realmode_booters()
{
	ROOT=$1
	
	TMPDIR=/tmp/rmupdate.$$
	trap "rm -rf $TMPDIR" EXIT

	# go get new versions of boot files into TMPDIR

	OLD_PWD=$(pwd)
	mkdir $TMPDIR
	cd $TMPDIR

	# i86pc.boot archive
	REQFILES="boot/mdboot boot/strap.com"
	$ZCAT $cpiodir/i86pc.boot$ZFIX |  cpio -id $REQFILES 2>/dev/null 
	mv $REQFILES $TMPDIR

	# i86pc.usr archive
	REQFILES="usr/platform/i86pc/lib/fs/ufs/pboot"
	REQFILES="$REQFILES usr/platform/i86pc/lib/fs/ufs/bootblk"
	$ZCAT $cpiodir/i86pc.usr$ZFIX | cpio -id $REQFILES 2>/dev/null
	mv $REQFILES $TMPDIR

	cd $OLD_PWD

	grep -s -v '^#' ${ROOT}/etc/vfstab | \
	    grep "[ 	]/boot[ 	]*pcfs[ 	]" >/dev/null

	if [ $? -eq 0 ] ; then
		echo 'Updating /boot on x86 boot partition.'

		REQFILES="mdboot strap.com"
		for f in ${REQFILES}; do
			if [ ! -f ${TMPDIR}/$f ]; then
				fail "Missing $f, aborting."
			fi
		done

		MDBOOT=${TMPDIR}/mdboot
		STRAP=${TMPDIR}/strap.com

		LUBIN=/usr/lib/lu
		TMP_FDFILE1=${TMPDIR}/fdfile1.$$
		LOGFILE=${TMPDIR}/mkfs.log.$$
		DDCOPY=${TMPDIR}/.dd_x86_boot_copy

		DISKID="$(grep -s -v '^#' ${ROOT}/etc/vfstab | \
		    grep "[ 	]/boot[ 	]*pcfs[ 	]" |\
		    awk '{print $1}' | sed -e 's:p0\:boot::g')"

		DISKID="$(basename ${DISKID})"

		# Obtain the disk table; it will look something like the following:
		#
# * Id    Act  Bhead  Bsect  Bcyl    Ehead  Esect  Ecyl    Rsect    Numsect
#   130   128  27     28     0       242    9      553     1728     8897472
		# 
		# Delete all blank lines, and all lines that begin with *,
		# leaving only actual fdisk entries that we can scan
		# looking for the X86BOOT partition

		fdisk -W - /dev/rdsk/${DISKID}p0 | \
		    grep -v '^*' | grep -v '^$' > ${TMP_FDFILE1}

		num=1

		while read id act bhead bcyl ehead ecyl rsect numsect
		do
			# Ignore entry if not X86 /boot partition
			# ID '190' is the X86BOOT partition (see man fdisk(1M))

			if [ $id -ne "190" ] ; then
				num=$(expr $num + 1)
				continue
			fi

			# Found X86 boot partition - save contents to $DDCOPY
			BOOTPART=/dev/rdsk/${DISKID}p${num}
			echo "Boot device is <${BOOTPART}>"

			ERRMSG="$(dd if=${BOOTPART} of=${DDCOPY} 2>&1)"
			if [ $? -ne 0 ] ; then
				[ -n "${ERRMSG}" ] && echo "${ERRMSG}"
				fail "Unable to save copy of <${BOOTPART}>."
			fi

			# mount copy of old /boot partition 
			LOBOOTDEV=$(lofiadm -a ${DDCOPY} 2>&1)
			if [ $? -ne 0 ] ; then
				[ -n "${LOBOOTDEV}" ] && echo "${LOBOOTDEV}"
				fail "Unable to make lo-device <${DDCOPY}>"
			fi
			SOURCE_BOOT_DEV="${TMPDIR}/tmpbootdev.$$"
			mkdir ${SOURCE_BOOT_DEV}
			ERRMSG=$(mount -F pcfs ${LOBOOTDEV} \
			    ${SOURCE_BOOT_DEV})
			if [ $? -ne 0 ] ; then
				[ -n "${ERRMSG}" ] && echo "${ERRMSG}"
				fail "Unable to mount lo-device <${LOBOOTDEV}>."
			fi

			# recreate existing boot partition with updated 
			# boot files

			# umount ${ROOT}'s /boot if mounted

			BOOTMOUNTPT=$(mount | grep ${DISKID}p0:boot 2>&1 | \
			    awk '{print $1;}')

			if [ -n "${BOOTMOUNTPT}" ] ; then
				echo "unmounting /dev/dsk/${DISKID}p0:boot"
				ERRMSG=$(umount \
				    /dev/dsk/${DISKID}p0:boot 2>&1)
				if [ $? -ne 0 ] ; then
					[ -n "${ERRMSG}" ] && echo "${ERRMSG}"
					fail "Unable to umount X86 boot device."
				fi
			fi

			echo "Making new pcfs file system on ${DISKID}"

			echo y | /usr/lib/fs/pcfs/mkfs -F pcfs \
			    -o S,s,B=$MDBOOT,b=BOOT,i=$STRAP \
			    /dev/rdsk/${DISKID}p0:boot >> ${LOGFILE} 2>&1
			if [ $? -ne 0 ] ; then
				echo "Unable to make pcfs:"
				cat ${LOGFILE}
				fail ""
			fi

			echo "Copying x86 boot partition contents back\c"
			echo " to new /boot fs."

			OLD_PWD=$(pwd)

			echo "Remounting freshened /boot partition"

			if [ -z "${BOOTMOUNTPT}" ] ; then 
				# boot ptn wasn't mounted
				BOOTMOUNT="/tmp/bootpart"
				mkdir ${BOOTMOUNT}
			else
				BOOTMOUNT=${BOOTMOUNTPT}
			fi

			ERRMSG=$(mount -F pcfs \
			    /dev/dsk/${DISKID}p0:boot ${BOOTMOUNT} 2>&1)

			if [ $? -ne 0 ] ; then
				[ -n "${ERRMSG}" ] && echo "${ERRMSG}"
				fail "Unable to mount X86 boot device."
			fi

			# copy old /boot contents
			cd ${SOURCE_BOOT_DEV}
			find . -mount \! -type s -print | \
			    cpio -pcdum ${BOOTMOUNT} 2>&1 | \
			    ${LUBIN}/lustripcpioerr

			if [ $? -ne 0 ] ; then
				fail "Unable to copy boot partition contents."
			fi

			cd ${OLD_PWD}

			# unmount and rm our boot mount, if we created it
			if [ -z "${BOOTMOUNTPT}" ] ; then
				ERRMSG=$(umount ${BOOTMOUNT} 2>&1)
				if [ $? -ne 0 ] ; then
					[ -n "${ERRMSG}" ] && echo "${ERRMSG}"
					fail "Unable to umount <$BOOTMOUNT>." 
				fi
				rm -rf ${BOOTMOUNT}
			fi

			# unmount, un-lofi, and rm SOURCE_BOOT_DEV

			ERRMSG=$(umount ${SOURCE_BOOT_DEV} 2>&1)
			if [ $? -ne 0 ] ; then
				[ -n "${ERRMSG}" ] && echo "${ERRMSG}"
				fail "Cannot umount lo-device <${LOBOOTDEV}>." 
			fi

			ERRMSG=$(lofiadm -d ${DDCOPY} 2>&1)
			if [ $? -ne 0 ] ; then
				[ -n "${ERRMSG}" ] && echo "${ERRMSG}"
				fail "Cannot remove lo-device <${LOBOOTDEV}>." 
			fi
		
			rm -rf ${SOURCE_BOOT_DEV}

		done < ${TMP_FDFILE1}
		rm ${TMP_FDFILE1} ${LOGFILE} ${DDCOPY}

	else

		# non boot-partition: use installboot to get pboot and bootblk
		echo "Updating /boot on Solaris partition."

		if [ -z "${ROOT}" ] ; then SEARCH="/"; else SEARCH="${ROOT}"; fi

		ROOTRAWDEV=$(mount | grep "^${SEARCH} on " | \
		    awk '{print $3}' | sed 's;/dsk;/rdsk;')

		if [ -z "${ROOTRAWDEV}" ] ; then
			[ -n "${ROOTRAWDEV}" && echo "${ROOTRAWDEV}" ] 
			fail "${SEARCH} must be a mounted filesystem"
		fi

		echo "Updating Solaris partition ${ROOTRAWDEV} with installboot"
		REQFILES="pboot bootblk"
		for f in ${REQFILES}; do
			if [ ! -f ${TMPDIR}/$f ]; then
				fail "Missing $f, aborting."
			fi
		done
		PBOOT=${TMPDIR}/pboot
		BOOTBLK=${TMPDIR}/bootblk
		install_boot_i386 $PBOOT $BOOTBLK ${ROOTRAWDEV}
		if [ $? -ne 0 ] ; then
			fail "Unable to installboot to <${ROOTRAWDEV}>." 
		fi
	fi
}

print "Verifying archives ..."

for a in generic $allarchs $rootarchs
do
	test -r $cpiodir/$a.root$ZFIX ||
		fail "bfu archive $cpiodir/$a.root$ZFIX missing"
done

if [ ! -r $cpiodir/generic.lib$ZFIX -o ! -r $cpiodir/generic.kernel$ZFIX -o \
    ! -r $cpiodir/generic.sbin$ZFIX ]; then
	old_style_archives="true"
	$ZCAT $cpiodir/generic.root$ZFIX | cpio -it 2>/dev/null | \
	    egrep -s '^etc/zones' && \
		fail "bfu archive $cpiodir/generic.{kernel,lib,sbin}$ZFIX" \
		     "missing;\npossible mkbfu version mismatch: pre-zones" \
		     "style archives with zones files."
fi

for a in generic $allarchs $usrarchs
do
	test -r $cpiodir/$a.usr$ZFIX ||
		fail "bfu archive $cpiodir/$a.usr$ZFIX missing"
done

for root in $rootlist
do
	cd $root || fail "Cannot cd $root"
	prologue=${root%/}/bfu.prologue
	if [ -f $prologue ]; then
		print "Executing $prologue"
		$prologue || fail "$prologue failed with code $?"
	fi
done

print "Performing basic sanity checks ..."

for dir in $usr $rootlist
do
	test -d $dir || fail "$dir does not exist"
	test -w $dir || fail "$dir is not writable"
	cd $dir || fail "Cannot cd $dir"
done

RM_32BIT_KERNEL=0;
if [ "$karch" = "sun4u" ] &&
   ($ZCAT $cpiodir/sun4u.root$ZFIX | cpio -itv 2>&1 |
    grep "^l.*platform/sun4u/kernel/unix -> sparcv9/unix$" > /dev/null);
    then
	RM_32BIT_KERNEL=1;
	if [ "$force_override" = "no" ] && 
	   (prtconf -F 2>&1 | egrep '(cgthree|bwtwo)' > /dev/null);
	    then
		print "\n\nERROR: You are upgrading to a 64-bit-only OS. " \
		      "Your frame buffer does not have a 64-bit driver and " \
		      "will not work after reboot.  To proceed you must run " \
		      "bfu with the -f flag.";
		exit;
	fi;
fi;

if [ $plat = "SUNW,Ultra-1" ] && [ ! -f $cpiodir/SUNW,Ultra-1.root$ZFIX ] &&
   [ "$force_override" = "no" ];
   then
	print "\nERROR: These archives do not have Ultra-1 platform support." \
	      "\nProceeding with this BFU may render this machine unbootable." \
	      "\nTo proceed anyway, you must run bfu with the -f flag.\n";
	exit;
fi;

for root in $rootlist
do
	rootprefix=${root%/}
	smf_check_repository
done

MINIMUM_OS_REV=10

#
# Perform additional sanity checks if we are upgrading the live system.
#
if [ "$rootlist" = "/" ]
then
	#
	# Disallow from older releases
	#
	os_rev=`uname -r | sed -e s/5.//`
	if [ $os_rev -lt $MINIMUM_OS_REV -a "$force_override" = "no" ]; then
		fail "Cannot bfu from pre-Solaris $MINIMUM_OS_REV"
	fi
	if [ ! -x /usr/sbin/svcadm ]; then
		fail "This version of bfu cannot run on pre-Greenline " \
		    "(s10_64) systems"
	fi

	#
	# Filesystem space checks
	#
	set $root 4 $usr 6
	while [ $# -gt 0 ]
	do
		test "`df -b $1 | tail -1 | nawk '{ print $2 }'`" -ge ${2}000 ||
			fail "Less than $2 MB free on $1 -- bfu not safe."
		shift 2
	done
	#
	# Disable kernel module unloading
	#
	print "Disabling kernel module unloading ... \c"
	test -x /usr/bin/adb || fail "/usr/bin/adb not found: bfu not safe."
	echo "moddebug/W20000" | adb -kw /dev/ksyms /dev/mem | grep moddebug
	#
	# Load modules and drivers here not to reload them when you access
	# /devices or its subdirectories later.
	#
	nawk '$1 !~ /^#|^$/ {print $1}' /etc/name_to_major | \
	sed -e 's/#.*$//' | while read driver
	do
		modload -p drv/${driver} >/dev/null 2>&1
	done
	ls $cpiodir >>/dev/null		# loads elfexec and networking

	# exec/intpexec and sys/kaio are needed by lofi
	modload -p exec/intpexec >/dev/null 2>&1
	modload -p sys/kaio >/dev/null 2>&1

	# umount /lib/libc.so.1 if necessary
	if [ -n "`mount | grep '^/lib/libc.so.1'`" ]
	then
		print "Unmounting /lib/libc.so.1 ..."
		umount /lib/libc.so.1
	fi

	PLAT=`/usr/bin/uname -i`
	ARCH=`/usr/bin/uname -m`
	# umount /platform/$PLAT/lib/libc_psr.so.1 if necessary
	if [ -n "`mount | grep "^/platform/$PLAT/lib/libc_psr.so.1"`" ]
	then
		print "Unmounting /platform/$PLAT/lib/libc_psr.so.1 ..."
		umount /platform/$PLAT/lib/libc_psr.so.1
	else
		# umount /platform/$ARCH/lib/libc_psr.so.1 if necessary
		if [ -n "`mount | grep "^/platform/$ARCH/lib/libc_psr.so.1"`" ]
		then
			print "Unmounting /platform/$ARCH/lib/libc_psr.so.1 ..."
			umount /platform/$ARCH/lib/libc_psr.so.1
		fi
	fi

	# umount /platform/$PLAT/lib/sparcv9/libc_psr.so.1 if necessary
	if [ -n "`mount | grep "^/platform/$PLAT/lib/sparcv9/libc_psr.so.1"`" ]
	then
		print "Unmounting /platform/$PLAT/lib/sparcv9/libc_psr.so.1 ..."
		umount /platform/$PLAT/lib/sparcv9/libc_psr.so.1
	else
		# umount /platform/$ARCH/lib/sparcv9/libc_psr.so.1 if necessary
		if [ -n "`mount | grep \
		    "^/platform/$ARCH/lib/sparcv9/libc_psr.so.1"`" ]
		then
			print "Unmounting \c"
			print "/platform/$ARCH/lib/sparcv9/libc_psr.so.1 ..."
			umount /platform/$ARCH/lib/sparcv9/libc_psr.so.1
		fi
	fi

	# umount /platform/sun4u-us3/lib/libc_psr.so.1 if necessary
	if [ -n "`mount | grep '^/platform/sun4u-us3/lib/libc_psr.so.1'`" ]
	then
		print "Unmounting /platform/sun4u-us3/lib/libc_psr.so.1 ..."
		umount /platform/sun4u-us3/lib/libc_psr.so.1
	fi

	# umount /platform/sun4u-us3/lib/sparcv9/libc_psr.so.1 if necessary
	if [ -n "`mount | grep '^/platform/sun4u-us3/lib/sparcv9/libc_psr.so.1'`" ]
	then
		print "Unmounting /platform/sun4u-us3/lib/sparcv9/libc_psr.so.1 ..."
		umount /platform/sun4u-us3/lib/sparcv9/libc_psr.so.1
	fi

	if [ -x /usr/sbin/zoneadm ]; then
		#
		# Stop any running zones: the init script will print a
		# message if needed.
		#
		if [ -x /etc/init.d/zones ]; then
			/etc/init.d/zones stop
		elif [ -x /lib/svc/method/svc-zones ]; then
			#
			# We need all zones to be down before proceeding.
			# We can't accomplish this by just disabling the
			# zones service, since it might already be disabled.
			# So we pretend to be SMF, and invoke the stop method.
			#
			# When zones are someday independently managed as
			# service instances, this will need to be revised.
			#
			export SMF_FMRI="svc:/system/zones:default"
			/lib/svc/method/svc-zones stop
			unset SMF_FMRI
		fi

		[ -z `zoneadm list | grep -v global` ] || \
		    fail "zone(s) failed to halt"
		#
		# Determine the installed zones, which we will want to do
		# after we're done with the global zone.  This is done now
		# rather than later in case bfu'ing the global zone causes
		# the zone configuration to become unreadable (e.g., via a
		# DTD flag day).
		#
		bfu_zone_list=$root/.bfu_zone_list
		rm -f $bfu_zone_list

		zoneadm list -pi | nawk -F: '{
			if ($3 == "installed" &&
			    ($6 == "native" || $6 == "" || $6 == "sn1")) {
				printf "%s %s\n", $2, $4
			}
		}' > $bfu_zone_list
	fi

	#
	# Stop sendmail so that mail doesn't bounce during the interval
	# where /etc/mail/aliases is (effectively) empty.
	#
	# (note that unlike other services here, /etc/init.d/sendmail
	# remains post-smf(5) because it is a public interface.)
	#
	if [ -r /etc/svc/volatile/repository_door ]; then
		print "Disabling sendmail temporarily ..."
		svcadm disable -t network/smtp
	else
		print "Killing sendmail ..."
		/etc/init.d/sendmail stop
	fi

	print "Disabling remote logins ..."
	echo "bfu in progress -- remote logins disabled" >/etc/nologin

	#
	# Stop syslogd so it doesn't interfere with saving preserved files.
	#
	if [ -f /etc/init.d/syslog ]; then
		print "Killing syslogd ..."
		/etc/init.d/syslog stop
	elif [ -r /etc/svc/volatile/repository_door ]; then
		print "Disabling syslog temporarily ..."
		svcadm disable -t system/system-log
	fi

	#
	# Stop apache so it doesn't get upset when the entire world changes
	# out from underneath it.
	#
	if [ -f /etc/init.d/apache ]; then
		print "Killing httpd ..."
		/etc/init.d/apache stop
	elif [ -r /etc/svc/volatile/repository_door ]; then
		print "Disabling httpd temporarily ..."
		svcadm disable -t network/http
	fi

	#
	# Kill off fmd so it doesn't get upset when the entire world changes
	# out from underneath it.
	#
	if [ -f /etc/init.d/savecore ]; then
		print "Killing fmd ..."
		pkill -x fmd
	elif [ -r /etc/svc/volatile/repository_door ]; then
		print "Disabling fmd temporarily ..."
		svcadm disable -t system/fmd
	fi

	#
	# Stop nscd so it doesn't interfere with stuff.
	#
	if [ -x /etc/init.d/nscd ]; then
		print "Killing nscd ..."
		/etc/init.d/nscd stop
	elif [ -r /etc/svc/volatile/repository_door ]; then
		print "Disabling nscd temporarily ..."
		svcadm disable -t system/name-service-cache:default
	fi

	if grep -v "^#" $rootprefix/etc/vfstab | grep boot | \
		grep "[ 	]pcfs[ 	]" >/dev/null 2>&1
	then
		boot_is_pcfs=yes
	fi

	smf_new_profiles

else
	#
	# Check ${root}/etc/motd for SunOS value to get `uname -r`
	#
	os_rev=`head -1 ${root}/etc/motd | sed -e 's/^.*SunOS //' | \
		awk '{print $1}' | sed -e s/5.//`
	if [ $os_rev -lt $MINIMUM_OS_REV -a "$force_override" = "no" ]; then
		fail "Cannot bfu from pre-Solaris $MINIMUM_OS_REV"
	fi
	if [ ! -x /usr/sbin/svcadm ]; then
		fail "This version of bfu cannot run on pre-Greenline " \
		    "(s10_64) systems"
	fi
fi

export PATH=/tmp/bfubin:$PATH
export LD_LIBRARY_PATH=/tmp/bfulib

if [ -h /tmp/bfulib/64 ]
then
	ldlib64="LD_LIBRARY_PATH_64=/tmp/bfulib/64"
	export LD_LIBRARY_PATH_64=/tmp/bfulib/64
fi

# turn off auxiliary filters, since they can cause objects to be loaded
# from outside of the protected environment.
export LD_NOAUXFLTR=1

#
# Since we've turned off auxiliary filters, libc_psr will normally not
# be loaded at all.  But libc_psr was overriding broken code in libc
# for over a week before the fix for 6324631, so we need to explicitly
# LD_PRELOAD it to allow users to bfu from the broken libc.  This can be
# removed once there are no sun4u machines bfued to Nevada bits between
# 9/7/2005 and 9/15/2005.
#
if [ -f /tmp/bfulib/libc_psr.so.1 ]; then
	export LD_PRELOAD_32=/tmp/bfulib/libc_psr.so.1
fi

print "Turning on delayed i/o ..."
fastfs -f $rootlist $usr
fastfs $rootlist $usr

#
# The "| tee -a $EXTRACT_LOG" following do_extraction() is not pulled into the
# function itself because it interferes with the cpio exit status detection.
# pcfs boot is an exception, since its cpio exit status is expected to be bad,
# so a heuristic must be employed to infer whether or not any errors occurred.
#
do_extraction() {
	compressed_archive=$1
	shift
	$ZCAT $compressed_archive | cpio -idmucB $* 2>&1 \
		|| extraction_error "extracting archive $1"
}

do_pcfs_boot_extraction() {
	PCFS_BOOT_LOG=/tmp/bfu-pcfs-boot-log.$$
	$ZCAT $1 | cpio -idmucB 2>&1 | grep -v "error.s" | \
		grep -v "cpio: Cannot chown()" | \
		grep -v "cpio: Error during chown()" | tee $PCFS_BOOT_LOG
	cat $PCFS_BOOT_LOG >> $EXTRACT_LOG
	egrep -s -v blocks $PCFS_BOOT_LOG
	if [ $? -eq 0 ]; then
		extraction_error "extracting archive $1 ... see $PCFS_BOOT_LOG"
	else
		rm -f $PCFS_BOOT_LOG
	fi
}

#
# Usage: extract_archives (root|usr|lib|sbin|kernel) arch-list
#
extract_archives() {
	base=$1
	shift
	test $base = usr && cd $usrroot || cd $root
	for archive in $*
	do
		print "Extracting $archive.$base$ZFIX ... \c" \
			| tee -a $EXTRACT_LOG
		test -h platform/$archive && rm platform/$archive
		if [ $base = root ]; then
			exclude="-f dev/fd home proc etc/mnttab"

			#
			# We don't want to overwrite the sharetab if
			# it is a mount-point. We assume it is a
			# mount-point if it is not writable.
			#
			if [ -f etc/dfs/sharetab ]; then
				if [ ! -w etc/dfs/sharetab ]; then
					exclude="$exclude etc/dfs/sharetab"
				fi
			fi

			[ -d system/contract ] &&
				exclude="$exclude system/contract"
			[ -d system/object ] &&
				exclude="$exclude system/object"
			[ -f etc/svc/repository.db ] &&
				exclude="$exclude etc/svc/repository.db"
			[ -e etc/repository_door ] &&
				exclude="$exclude etc/repository_door"
			[ -f etc/svc/volatile ] &&
				exclude="$exclude etc/svc/volatile"
			do_extraction $cpiodir/$archive.$base$ZFIX $exclude |
				tee -a $EXTRACT_LOG
		elif [ $base = usr ]; then
			do_extraction $cpiodir/$archive.$base$ZFIX \
				-f "usr/openwin" | tee -a $EXTRACT_LOG
		else
			do_extraction $cpiodir/$archive.$base$ZFIX \
				| tee -a $EXTRACT_LOG
		fi
	done
	cd $root
}

extract_boot_archives() {
	base=$1
	shift
	cd $root
	for archive in $*
	do
		if [ ! -f $cpiodir/$archive.$base$ZFIX ]; then
			continue
		fi
		print "Extracting $archive.$base$ZFIX ... \c" \
			| tee -a $EXTRACT_LOG
		if [ $boot_is_pcfs = yes ]; then
			do_pcfs_boot_extraction $cpiodir/$archive.$base$ZFIX
		else
			do_extraction $cpiodir/$archive.$base$ZFIX | \
				tee -a $EXTRACT_LOG
		fi
		$ZCAT $cpiodir/$archive.$base$ZFIX | cpio -it 2>&1 | \
		    grep  "boot/solaris/devicedb/master" >/dev/null 2>&1
		if [ "$?" = "0" ]; then
			have_realmode=yes
		fi
	done
	cd $root
}

#
# Classic boot pboot and bootblk compatibility with old archives
#
setup_pboot()
{
	NEWPBOOTDIR=$GATE/public/pboot
	NEWPBOOT=${NEWPBOOTDIR}/pboot
	NEWBOOTBLK=${NEWPBOOTDIR}/bootblk
	PBOOTDIR=$usr/platform/$karch/lib/fs/ufs
	PBOOT=${PBOOTDIR}/pboot
	BOOTBLK=${PBOOTDIR}/bootblk

	# they should already be there, but...
	if [ -f $NEWPBOOT -a ! -f $PBOOT ]; then
		print "Installing pboot from $NEWPBOOTDIR"
		cp $NEWPBOOT $PBOOT
	fi
	if [ -f $NEWBOOTBLK -a ! -f $BOOTBLK ]; then
		print "Installing bootblk from $NEWPBOOTDIR"
		cp $NEWBOOTBLK $BOOTBLK
	fi

	if [ -f $NEWPBOOT -a -f $PBOOT ]; then
		LATEST=`ls -Lt $PBOOT $NEWPBOOT | head -1`
		if [ "$LATEST" = "$NEWPBOOT" ]; then
			print "Updating pboot from $NEWPBOOT"
			cp $NEWPBOOT $PBOOT
		fi
	fi
	if [ -f $NEWBOOTBLK -a -f $BOOTBLK ]; then
		LATEST=`ls -Lt $BOOTBLK $NEWBOOTBLK | head -1`
		if [ "$LATEST" = "$NEWBOOTBLK" ]; then
			print "Updating bootblk from $NEWBOOTBLK"
			cp $NEWBOOTBLK $BOOTBLK
		fi
	fi
	if [[ "$rootslice" = /dev/rdsk/* ]]; then
		print "Installing boot block."
		( cd $PBOOTDIR ;
		    install_boot_i386 ./pboot ./bootblk ${rootslice%??}s2 )
	fi
	#
	# Since /platform/i86pc/boot/solaris/boot.bin is moved
	# to /boot/solaris, remove the old one if it really
	# exists.
	#
	OLDBOOTDIR=${root}/platform/i86pc/boot/solaris
	OLDBOOTBIN=${OLDBOOTDIR}/boot.bin
	if [ ! -h ${OLDBOOTDIR} -a -f ${OLDBOOTBIN} ] ;
	then
		print "Removing old boot.bin."
		rm -rf ${OLDBOOTBIN}
	fi
}

#
# Multiboot support
#

saved_boot_files="
	solaris/bootenv.rc
	solaris/devicedb/master
"

#
# transition from multiboot to dca
#
check_multi_to_dca_boot()
{
	bootdev=`grep p0:boot $rootprefix/etc/vfstab | \
		grep pcfs | nawk '{print $1}'`
	if [ "$bootdev" != "" ]; then
		is_pcfs_boot=yes
	fi

	if [ $is_pcfs_boot = yes ]; then
		df -h | grep stubboot >/dev/null 2>&1
		if [ $? -eq 0 ]; then

			# save configurable files from /boot
			# before remounting /stubboot.
			# files are relative to /boot.
			for file in $saved_boot_files
			do
				dir="`dirname $rootprefix/stubboot/$file`"
				mkdir -p $dir
				cp $rootprefix/boot/$file $dir
			done

			echo "unmount $bootdev at $rootprefix/stubboot"
			ERRMSG=$(umount $bootdev 2>&1)
			if [ $? -ne 0 ] ; then
				[ -n "${ERRMSG}" ] && echo "${ERRMSG}"
				fail "Unable to umount $bootdev on $rootprefix/stubboot."
			fi

			# adjust vfstab
			sed -e "s/[ 	]\/stubboot[ 	]/	\/boot	/" \
			    <$rootprefix/etc/vfstab >$rootprefix/etc/vfstab+
			mv $rootprefix/etc/vfstab $rootprefix/etc/vfstab-
			mv $rootprefix/etc/vfstab+ $rootprefix/etc/vfstab

			ERRMSG=$(mount -F pcfs $bootdev $rootprefix/boot 2>&1)
			if [ $? -ne 0 ] ; then
				[ -n "${ERRMSG}" ] && echo "${ERRMSG}"
				fail "Unable to mount $bootdev on $rootprefix/boot."
			fi
		fi
	fi
}

check_dca_to_multiboot()
{
	bootdev=`grep p0:boot $rootprefix/etc/vfstab | \
	    grep pcfs | nawk '{print $1}'`
	if [ "$bootdev" != "" ]; then
		is_pcfs_boot=yes
	fi
	if [ $system_type != dca ]; then
		return
	fi

	# ensure bootpath is in $rootprefix/boot/solaris/bootenv.rc
	# It's ok to put a meta device path in there
	bootenvrc=$rootprefix/boot/solaris/bootenv.rc
	grep "^setprop[	 ]*bootpath[	 ]" $bootenvrc > /dev/null
	if [ $? != 0 ]; then
		rootdev=`grep -v "^#" $rootprefix/etc/vfstab | \
		    grep "[	 ]/[	 ]" | nawk '{print $1}'`
		bootpath=`ls -l $rootdev | nawk '{ print $NF }' |\
		    sed "s#../../devices##"`
		echo "setprop bootpath '$bootpath'" >> $bootenvrc
	fi

	rm -f $rootprefix/boot/mdboot
}

#
# Figure out the boot architecture of the current system:
# 1. If an i86xpv kernel exists, it's a xpv system
# 2. If dboot_image is in unix, it's a dboot system
# 3. Otherwise, if multiboot is present, it's a multiboot system
# 4. Otherwise, it's a pre-multiboot system
#
# This is called before we lay down the new archives.
#
check_system_type()
{
	if [ -f $root/platform/i86xpv/kernel/unix ]; then
		system_type=xpv
	elif [ -x $root/boot/solaris/bin/symdef ] && \
	    $root/boot/solaris/bin/symdef $root/platform/i86pc/kernel/unix \
	    dboot_image; then
		system_type=directboot
	elif [ -x $root/platform/i86pc/multiboot ]; then
		system_type=multiboot
	else
		system_type=dca
	fi
}

#
# Detect SVM root and return the list of raw devices under the mirror
#
get_rootdev_list()
{
	if [ -f $rootprefix/etc/lu/GRUB_slice ]; then
		grep '^PHYS_SLICE' $rootprefix/etc/lu/GRUB_slice | cut -d= -f2
	else
		metadev=`grep -v "^#" $rootprefix/etc/vfstab | \
			grep "[	 ]/[ 	]" | nawk '{print $2}'`
		if [[ $metadev = /dev/rdsk/* ]]; then
       		 	rootdevlist=`echo "$metadev" | sed -e "s#/dev/rdsk/##"`
		elif [[ $metadev = /dev/md/rdsk/* ]]; then
       		 	metavol=`echo "$metadev" | sed -e "s#/dev/md/rdsk/##"`
			rootdevlist=`metastat -p $metavol |\
			    grep -v "^$metavol[ 	]" | nawk '{print $4}'`
		fi
		for rootdev in $rootdevlist
		do
			echo /dev/rdsk/$rootdev
		done
	fi
}

#
# Done once per transition from classic (dca) to multi boot
#
setup_stubboot()
{
	bootdev=`grep -v "^#" $rootprefix/etc/vfstab | grep pcfs | \
		grep "[ 	]/boot[ 	]"`
	if [[ -n $bootdev ]] ; then

		bootdev=`echo "$bootdev" | nawk '{print $1}'`
		rbootdev=`echo "$bootdev" | sed -e "s/dev\/dsk/dev\/rdsk/"`

		# Remount boot partition as /stubboot, set up new /boot
		mkdir -p $rootprefix/stubboot

		ERRMSG=$(umount $bootdev 2>&1)
		if [ $? -ne 0 ] ; then
			[ -n "${ERRMSG}" ] && echo "${ERRMSG}"
			fail "Unable to umount $bootdev."
		fi
		ERRMSG=$(mount -F pcfs $bootdev $rootprefix/stubboot 2>&1)
		if [ $? -ne 0 ] ; then
			[ -n "${ERRMSG}" ] && echo "${ERRMSG}"
			fail "Unable to mount $bootdev on $rootprefix/stubboot."
		fi

		mkdir -p $rootprefix/boot
		cp -r $rootprefix/stubboot/* $rootprefix/boot
	
		# adjust /etc/vfstab
		sed <$rootprefix/etc/vfstab \
		    -e "s/[ 	]\/boot[ 	]/	\/stubboot	/" | \
			sed -n >$rootprefix/etc/vfstab+ '
			/p0:boot/ {
				s/[ 	]no/	yes/
				}
				p
			'

		mv $rootprefix/etc/vfstab $rootprefix/etc/vfstab-
		mv $rootprefix/etc/vfstab+ $rootprefix/etc/vfstab
	fi
}

#
# multiboot: install grub on the boot slice
#
install_grub()
{
	STAGE1=$rootprefix/boot/grub/stage1
	STAGE2=$rootprefix/boot/grub/stage2

	if [ -x $rootprefix/boot/solaris/bin/update_grub ]; then
		/tmp/bfubin/ksh $rootprefix/boot/solaris/bin/update_grub \
		    -R $root
	elif [ $is_pcfs_boot = no ]; then
		get_rootdev_list | while read rootdev
		do 
			print "Install grub on $rootdev"
			PATH=/tmp/bfubin /tmp/bfubin/installgrub \
				$STAGE1 $STAGE2 $rootdev
		done
	else
		# copy /boot grub & solaris to /stubboot
		cp -r $rootprefix/boot/grub $rootprefix/stubboot/grub
		cp -r $rootprefix/boot/solaris $rootprefix/stubboot/solaris

		# Adjust grub paths relative to pcfs filesystem
		rm -rf $rootprefix/stubboot/boot
		mkdir -p $rootprefix/stubboot/boot
		mv $rootprefix/stubboot/grub $rootprefix/stubboot/boot
		mv $rootprefix/stubboot/solaris $rootprefix/stubboot/boot

		#
		# Run installgrub after copying stubboot to avoid overwriting
		# /stubboot/boot/grub/stage2, which must stay untouched.
		#
		bootdev=`grep -v "^#" $rootprefix/etc/vfstab | grep pcfs | \
			grep "[ 	]/stubboot[ 	]" | nawk '{print $1}'`
		rbootdev=`echo "$bootdev" | sed -e "s/dev\/dsk/dev\/rdsk/"`
		if [ "$rbootdev" != "" ]; then
			print "Install grub on $rbootdev"
			PATH=/tmp/bfubin /tmp/bfubin/installgrub $STAGE1 $STAGE2 $rbootdev
		fi
	fi
}

#
# We check for several possibilites of a bootenv.rc line:
#
# 1. setprop name 'value'
# 2. setprop name "value"
# 3. setprop name value
#
parse_bootenv_line()
{
	line=$1
	value=`echo $line | grep "'" | cut -d\' -f2`
	if [ -z "$value" ]; then
		value=`echo $line | grep "\"" | cut -d\" -f2`
		if [ -z "$value" ]; then
			value=`echo $line | cut -d' ' -f3-`
		fi
	fi
	echo $value
}

update_bootenv()
{
	bootenvrc=$rootprefix/boot/solaris/bootenv.rc
	bootenvrc_updated=0

	# Note: the big space below is actually a space and tab
	boot_file=`grep '^setprop[ 	]\{1,\}boot-file\>' $bootenvrc`
	if [ -n "$boot_file" ]; then
		file=`parse_bootenv_line "$boot_file"`
		if [ -n "$file" ]; then
			PATH=/tmp/bfubin /tmp/bfubin/bootadm set-menu kernel="$file"
			bootenvrc_updated=1
		fi
	fi

	console=`grep '^setprop[ 	]\{1,\}console\>' $bootenvrc`
	if [ -z "$console" ]; then
		console=`grep '^setprop[ 	]\{1,\}input-device\>' \
		    $bootenvrc`
	fi
	if [ -n "$console" ]; then
		cons=`parse_bootenv_line "$console"`
	fi
	boot_args=`grep '^setprop[ 	]\{1,\}boot-args\>' $bootenvrc`
	if [ -n "boot_args" ]; then
		args=`parse_bootenv_line "$boot_args"`
	fi
	if [ -n "$cons" ] && [ -n "$args" ]; then
		# If args starts with a -B, remove it and add a comma instead
		if echo $args | grep '^-B ' >/dev/null; then
			new_args=`echo $args | sed 's/^-B //'`
			args_line="-B console=$cons,$new_args"
		else
			args_line="-B console=$cons $args"
		fi
	elif [ -n "$cons" ]; then
		args_line="-B console=$cons"
	elif [ -n "$args" ]; then
		args_line="$args"
	else
		args_line=""
	fi
	if [ -n "$args_line" ]; then
		PATH=/tmp/bfubin /tmp/bfubin/bootadm set-menu args="$args_line"
		bootenvrc_updated=1
	fi

	if [ $bootenvrc_updated = 1 ]; then
		egrep -v '^setprop[ 	]+(boot-file|boot-args)[ 	]' $bootenvrc > ${bootenvrc}.new
		[ -s ${bootenvrc}.new ] && mv ${bootenvrc}.new $bootenvrc
	fi
}

get_biosdisk()
{
	rootdev=$1
	rootphys=`ls -l $rootdev | nawk '{ print $NF }' | \
	    sed -e "s/\.\.\/\.\.\/devices//" -e "s/:[abcdefgh],raw//"`
	rbootdev=`echo "$rootdev" | sed -e "s/s[0-7]/p0/"`

	#
	# Use biosdev to get the bios disk number
	#
	biosdisk=`biosdev | grep $rootphys | \
		nawk '{print $1}' | sed -e "s/0x8//"`
}

#
# multiboot: set up initial grub menu
#
update_grub_menu()
{
	MENU=$rootprefix/boot/grub/menu.lst

	grubhd=$1

	if [ $archive_type = multiboot ]; then
		BOOT_PROG="kernel /platform/i86pc/multiboot"
		BOOT_ARCHIVE="module /platform/i86pc/boot_archive"
	else
		#
		# directboot archives
		#
		BOOT_PROG="kernel\$ /platform/i86pc/kernel/\$ISADIR/unix"
		BOOT_ARCHIVE="module\$ /platform/i86pc/\$ISADIR/boot_archive"
	fi

	#
	# The failsafe archives may be different than the boot archives
	#
	if [ -x /boot/platform/i86pc/kernel/unix ]; then
		BOOT_FAILSAFE_FILE="/boot/platform/i86pc/kernel/unix"
		BOOT_FAILSAFE_SUFFIX=""
	else
		BOOT_FAILSAFE_FILE="/boot/multiboot"
		BOOT_FAILSAFE_SUFFIX="kernel/unix"
	fi

	#
	# Append some useful entries to the existing menu
	#
	echo "Update GRUB menu $MENU with entries for $grubhd"

	grep ^default $MENU > /dev/null
	[ $? = 0 ] || echo "default=0" >> $MENU
	grep ^timeout $MENU > /dev/null
	[ $? = 0 ] || echo "timeout=10" >> $MENU

	echo "#serial --unit=0 --speed=9600" >> $MENU
	echo "#terminal serial" >> $MENU
	echo "#splashimage=$grubhd/boot/grub/splash.xpm.gz" >> $MENU
	echo "title Solaris" >> $MENU
	echo "	root $grubhd" >> $MENU
	echo "	${BOOT_PROG}" >> $MENU
	echo "	${BOOT_ARCHIVE}" >> $MENU

	echo "GRUB menu entry 'Solaris' boots to eeprom(1m) settings"

	if [ -f ${rootprefix}/$BOOT_FAILSAFE_FILE ] &&
	    [ -f ${rootprefix}/boot/x86.miniroot-safe ] ; then

		TTY=`grep "^setprop input-device" \
		    ${rootprefix}/boot/solaris/bootenv.rc | cut -f 2 -d \'`
		if [ -z "${TTY}" ] ; then
			TTY=`grep "^setprop console" \
			    ${rootprefix}/boot/solaris/bootenv.rc | \
			    cut -f 2 -d \'`
		fi

		if [ "${TTY}" = "ttya" ] || [ "${TTY}" = "ttyb" ] ; then
			FS_CONSOLE="-B console=${TTY}"
		fi

cat >>$MENU <<EOF
title Solaris failsafe
  root $grubhd
  kernel $BOOT_FAILSAFE_FILE $BOOT_FAILSAFE_SUFFIX $FS_CONSOLE -s
  module /boot/x86.miniroot-safe
EOF
	fi
}

bootadm_f_flag=""

install_failsafe()
{
	if [ "$root" != "/" ] || \
	    [ -f /boot/x86.miniroot-safe ] || \
	    [ ! -x ${GATEPATH}/public/bin/update_failsafe ]; then
		#
		# Either we're not bfu'ing /, or the failsafe archives were
		# already installed, or update_failsafe is not available.
		# If the old failsafe archives were multiboot, clear out the
		# directboot kernel.
		# 
		if [ $failsafe_type = multiboot ]; then
			rm -f $rootprefix/boot/platform/i86pc/kernel/unix
		elif [ $failsafe_type = directboot ]; then
			cp /tmp/bfubin/unix \
			    $rootprefix/boot/platform/i86pc/kernel/unix
		fi
	else
		echo "Updating failsafe archives"
		${GATEPATH}/public/bin/update_failsafe

		# Force bootadm to update the failsafe entry
		bootadm_f_flag="-f"
	fi
}

setup_grub_menu()
{
	MENU=$rootprefix/boot/grub/menu.lst

	get_rootdev_list | while read rootdev
	do
		rootphys=`ls -l $rootdev | nawk '{print $NF}' | \
		    sed -e "s/\.\.\/\.\.\/devices//"`
		gslice=`echo "$rootphys" | cut -f 2 -d : | sed s/,raw//`
		rootphys=`echo "$rootphys" | sed -e "s/:[abcdefgh],raw//"`
		rbootdev=`echo "$rootdev" | sed -e "s/s[0-7]/p0/"`

		#
		# Wallow through fdisk to get the active partition number
		# Partition numbering is zero-based
		#
		part=0
		fdisk -W - $rbootdev | grep -v '^*' | grep -v '^$' | \
		while read id act bhead bcyl ehead ecyl rsect numsect
		do
			# Find solaris partition, either older 130 or 191
			if [ $id -eq "191" -o $id -eq "130" ] ; then
				break
			fi
			part=`expr "$part" + 1`
		done

		get_biosdisk $rootdev
		grubhd="(hd${biosdisk},${part},${gslice})"

		#
		# update the grub menu if it doesn't exist or
		# doesn't have usable boot entries
		#
		if [ -f $MENU ]; then
			grep -v "^#" $MENU | grep $grubhd >/dev/null 2>&1
			if [ $? -eq 1 ]; then
				update_grub_menu $grubhd
			fi
		else
			update_grub_menu $grubhd
		fi
	done
}

#
# Build the multiboot boot archive
#
build_boot_archive()
{
	#
	# We should be able to run bootadm here but that's a
	# little more complicated than one would think
	#bootadm_args=${rootprefix:+-R $rootprefix}
	#PATH=/tmp/bfubin /tmp/bfubin/bootadm update $bootadm_args

	cr_args=${rootprefix:+ -R $rootprefix}
	LD_LIBRARY_PATH=/tmp/bfulib PATH=/tmp/bfubin \
	    /tmp/bfubin/ksh $rootprefix/boot/solaris/bin/create_ramdisk $cr_args

	#
	# Disable the boot-archive service on the first boot
	# to silence complaints about new files
	# svccfg -s system/boot-archive setprop start/exec = true

	mkdir -p $rootprefix/bfu.conflicts/lib/svc/method
	cp $rootprefix/lib/svc/method/boot-archive \
	    $rootprefix/bfu.conflicts/lib/svc/method/boot-archive
	cat >$rootprefix/lib/svc/method/boot-archive <<"EOF"
#!/sbin/sh
exit 0
EOF

	cat >$rootprefix/etc/rc2.d/S99postbfu <<EOF
#!/bin/sh
#
case "\$1" in
'start')
	cp /bfu.conflicts/lib/svc/method/boot-archive /lib/svc/method/boot-archive
	chmod +x /lib/svc/method/boot-archive
        rm -f /etc/rc2.d/S99postbfu
        ;;
*)
        echo "usage: \$0 start"
        exit 1
        ;;
esac
exit 0
EOF

	chmod +x $rootprefix/etc/rc2.d/S99postbfu
	chmod +x $rootprefix/lib/svc/method/boot-archive
	chmod +x $rootprefix/bfu.conflicts/lib/svc/method/boot-archive
}

disable_boot_service()
{
	svccfg -s system/boot-archive setprop start/exec = true
	cat >$rootprefix/lib/svc/method/boot-archive <<EOF
#!/sbin/sh
. /lib/svc/share/smf_include.sh
. /lib/svc/share/fs_include.sh
exit 0
EOF
}

dir_is_inherited() {
	dir=$1
	set -- `zonecfg -z $zone info inherit-pkg-dir dir=/$dir`
	[ "$3" = "/$dir" ] && return 0 || return 1
}

check_boot_env()
{
	if [ $multi_or_direct = yes ]; then
		if [ $archive_type != $system_type ]; then
			install_failsafe
			[ $system_type = dca ] && setup_grub_menu

			if [ $have_new_bootadm = yes ] || \
			    [ -x /tmp/bfubin/symdef ] && \
			    [ -x /tmp/bfubin/bootadm ] && \
			    /tmp/bfubin/symdef /tmp/bfubin/bootadm \
			    dboot_or_multiboot; then
				if [[ -z $rootprefix ]]; then
					PATH=/tmp/bfubin /tmp/bfubin/bootadm \
					    -m upgrade $bootadm_f_flag
				else
					PATH=/tmp/bfubin /tmp/bfubin/bootadm \
					    -m upgrade -R $rootprefix \
					    $bootadm_f_flag
				fi
				install_grub
				[ $archive_type = directboot ] && update_bootenv
			else
				install_grub
				cat >&2 <<EOF

WARNING: Cannot find new bootadm.  If bfu'ing across the multiboot/directboot
boundary, you will need to manually change menu.lst.  See
http://www.sun.com/msg/SUNOS-8000-CF for details.

EOF
			fi

			#
			# If we're going backwards, we need to remove the
			# symdef binary.
			#
			if [ -f $rootprefix/boot/solaris/bin/symdef ] && \
			    [ $archive_type = multiboot ]
			then
				rm -f $rootprefix/boot/solaris/bin/symdef \
				    $rootprefix/boot/solaris/bin/update_grub
			fi
		elif [ $failsafe_type = multiboot ]; then
			rm -f $rootprefix/boot/platform/i86pc/kernel/unix
		elif [ $failsafe_type = directboot ]; then
			cp /tmp/bfubin/unix \
			    $rootprefix/boot/platform/i86pc/kernel/unix
		fi
		build_boot_archive
	else
		disable_boot_service
	fi
}

mondo_loop() {
	typeset pkgroot
	typeset pkg
	root=$1
	zone=$2
	if [ $zone != global ]; then
		usrroot=$root
	fi

	# If the archives being installed contain i86pc.boot, 
	# check to see if it contains strap.com, one of the
	# four possibly-required booters.  If i86pc.boot does,
	# try to upgrade the realmode booters from the current 
	# archive set.
	#
	# Don't bother doing the upgrade for diskless bfu, as the boot
	# will be done with floppy or PXE, which must match the build
	# anyway (floppy must match or add_install_client must be 
	# rerun), and in any event we can't touch the boot bits
	# for diskless boot from here.  Also don't do this for
	# any zone but 'global'.

	cd $root || fail "Cannot cd $root"
	rootprefix=${root%/}
	pkgroot=${rootprefix:+-R $rootprefix}

	if [ "$karch" = "i86pc" -a "$diskless" = "no" -a "$zone" = "global" ]
	then
		remove_properties
		check_system_type
		if boot_is_upgradeable $root && \
		    [ $archive_type = dca ]; then
			check_multi_to_dca_boot
			print "\nUpdating realmode boot loaders\n"
			update_realmode_booters $root
			setup_pboot
		fi
		if [ $multi_or_direct = yes ]; then
			check_dca_to_multiboot
			if [ $is_pcfs_boot = yes ]; then
				setup_stubboot
			fi
		fi
	fi

	SECONDS=0		# time each iteration

	print "\nSaving configuration files in $rootprefix/bfu.child ... \c"
	cd $root
	rm -rf bfu.default bfu.restore	# historical
	rm -rf bfu.child bfu.conflicts
	mkdir bfu.child bfu.conflicts
	filelist $zone | cpio -pdmu bfu.child || \
	    fail 'failed to save config files'
	test -f etc/motd && mv etc/motd etc/motd.old

	#
	# If the var/sadm/system/admin/INST_RELEASE file still exists,
	# this system has never been bfu'd before.  Therefore, the
	# information in var/sadm/install/contents is still valid and
	# can be used to determine whether files have been modified
	# since installation (the bfu.ancestors directory serves this
	# purpose for systems that have already been bfu'd.)
	#
	if [ -f var/sadm/system/admin/INST_RELEASE ] ; then
		firstbfu=yes
	else
		firstbfu=no
	fi

	#
	# bfu'ed systems are not upgradeable; prevent suninstall from
	# even *presenting* the upgrade option by removing INST_RELEASE.
	#
	rm -f var/sadm/system/admin/INST_RELEASE

	#
	# Hacks to work around minor annoyances and make life more pleasant.
	# Part 1 of 2: pre-archive-extraction stuff
	#

	#
	# Do not remove remove_initd_links, since this makes sure things
	# work properly when init scripts are shuffled around.
	#
	remove_initd_links

	#
	# Remove rc.d scripts and things made superfluous by smf.
	# Backwards BFUs will resurrect them from the archives.
	#
	smf_cleanup

	#
	# New, enabled-by-default services need to be checked for, such
	# that their enabled status is not flipped by BFU after their
	# initial arrival.
	#
	smf_handle_new_services

      	# Reflect SUNWcsr's pre-install change, ensures
	# the i.hosts action script works during 'acr'	
	if [[ -f $rootprefix/etc/inet/ipnodes && \
			! -h $rootprefix/etc/inet/ipnodes ]]; then
		rm -f $rootprefix/etc/inet/ipnodes.hostsmerge
		cp -p $rootprefix/etc/inet/ipnodes \
			$rootprefix/etc/inet/ipnodes.hostsmerge
	fi

	#
	# Remove obsolete disassembler module
	#
	if [ $target_isa = sparc ]; then 
		rm -rf $usr/lib/mdb/disasm/*
		rm -f $root/kernel/kmdb/sparcv9/sparc
	fi

	#
	# Remove obsolete Sun-Fire-880 (daktari) FMA Fault Tree directory
	# and file.  Backwards BFUs will resurrect them from the archives.
	#
	if [ $target_isa = sparc ]; then
		rm -rf $usr/platform/SUNW,Sun-Fire-880/lib/fm
	fi

	#
	# Remove old ndpd header (moved to /usr/include per 6509782)
	#
	rm -f $usr/include/protocols/ndpd.h

	#
	# Remove old FMA dictionary files
	#
	rm -f $usr/lib/fm/FMD.dict
	rm -f $usr/lib/fm/SUN4U.dict
	rm -f $usr/lib/fm/SUNOS.dict

	# Remove unused SMF dictionary
	rm -f $root/usr/lib/fm/dict/SMF.dict
	rm -f $root/usr/lib/locale/C/LC_MESSAGES/SMF.mo

	#
	# Remove old FMA .eft files and directories
	#
	rm -f $usr/platform/sun4u/lib/fm/eft/pci-sun4u.eft
	rm -rf $usr/platform/SUNW,Serverblade1/lib/fm
	rm -rf $usr/platform/SUNW,Sun-Fire/lib/fm
	rm -rf $usr/platform/SUNW,Sun-Fire-15000/lib/fm

	#
	# Remove old FMA LDOMS files
	#
	rm -f $usr/platform/sun4v/lib/fm/fmd/libldom.so.1
	rm -f $usr/platform/sun4v/lib/fm/fmd/libldom.so
	rm -f $usr/platform/sun4v/lib/fm/fmd/llib-lldom
	rm -f $usr/platform/sun4v/lib/fm/fmd/llib-lldom.ln
	rm -f $usr/platform/sun4v/lib/fm/fmd/sparcv9/libldom.so.1
	rm -f $usr/platform/sun4v/lib/fm/fmd/sparcv9/libldom.so
	rm -f $usr/platform/sun4v/lib/fm/fmd/sparcv9/llib-lldom.ln

	#
	# Remove old topology data
	#
	rm -rf $usr/lib/fm/topo
	rm -f $usr/platform/*/lib/fm/topo/hc-topology.xml

	#
	# Remove old prtopo and obsoleted include file.
	#
	rm -f $usr/include/fm/libtopo_enum.h
	rm -f $usr/lib/fm/prtopo

	#
	# Remove obsolete buildmnttab script.  Backwards BFUs will
	# resurrect it by extracting it from the archives.
	#
	rm -f $root/etc/init.d/buildmnttab
	rm -f $root/etc/rcS.d/S70buildmnttab.sh

	#
	# Break-up of inetsvc, inetinit & network -- remove both the old
	# and new init scripts.  The correct ones will be extracted from
	# the archives whether bfu'ing backwards or forwards.
	#
	# old: need to remove going forwards:
	#
	rm -f $root/etc/rc0.d/K42inetsvc
	rm -f $root/etc/rc1.d/K42inetsvc
	rm -f $root/etc/rcS.d/K42inetsvc
	rm -f $root/etc/rcS.d/S29network.sh
	#
	# new: need to remove going backwards:
	#
	rm -f $root/etc/init.d/domainname
	rm -f $root/etc/init.d/inetd
	rm -f $root/etc/init.d/named
	rm -f $root/etc/init.d/nodename
	rm -f $root/etc/rc0.d/K40inetd
	rm -f $root/etc/rc0.d/K42named
	rm -f $root/etc/rc1.d/K40inetd
	rm -f $root/etc/rc1.d/K42named
	rm -f $root/etc/rc2.d/S69domainname
	rm -f $root/etc/rc2.d/S72named
	rm -f $root/etc/rc2.d/S77inetd
	rm -f $root/etc/rcS.d/K40inetd
	rm -f $root/etc/rcS.d/K42named
	rm -f $root/etc/rcS.d/S28network.sh
	rm -f $root/etc/rcS.d/S29nodename.sh

	#
	# Remove Zones init scripts: they will be extracted properly
	# going forwards; after going backwards, they will be gone,
	# thus preventing scary warnings on subsequent bfu's.
	#
	rm -f $root/etc/init.d/zones
	rm -f $root/etc/rc0.d/K01zones
	rm -f $root/etc/rc1.d/K01zones
	rm -f $root/etc/rc2.d/K01zones
	rm -f $root/etc/rc3.d/S99zones
	rm -f $root/etc/rcS.d/K01zones

	#
	# Remove <inet>6 STREAMS modules; these no longer exist (and
	# should never have existed in the first place).
	#
	rm -f $root/kernel/strmod/icmp6		\
	    $root/kernel/strmod/ip6		\
	    $root/kernel/strmod/tcp6		\
	    $root/kernel/strmod/udp6		\

	rm -f $root/kernel/strmod/sparcv9/icmp6 \
	    $root/kernel/strmod/sparcv9/ip6	\
	    $root/kernel/strmod/sparcv9/tcp6	\
	    $root/kernel/strmod/sparcv9/udp6	\

	#
	# Remove old ZFS binaries (back when it was three modules)
	#
	find $root/kernel/drv -name zpool 2> /dev/null | xargs rm -f
	rm -f $root/kernel/drv/zpool.conf
	rm -f $root/kernel/drv/zpool.cache

	find $root/kernel/drv -name zvol 2> /dev/null | xargs rm -f
	rm -f $root/kernel/drv/zvol.conf

	#
	# Remove /usr/lib/old_libthread since support for it has
	# been removed from the kernel in Solaris 10.  If this is
	# a backwards BFU, it will all be extracted again by cpio.
	rm -rf $usr/lib/old_libthread

	# Remove libconfig 
	rm -f $usr/lib/drv/config_md.so.1
	rm -f $usr/include/config_md.h
	# remove libssd
	rm -f $usr/lib/libssd.a
	rm -f $usr/lib/libssd.so
	rm -f $usr/lib/libssd.so.1
	# remove libap
	rm -f $usr/lib/libap_dmd.a
	rm -f $usr/lib/libap_dmd.so.1
	# remove libintpos
	rm -f $usr/lib/libintpos.a
	rm -f $usr/lib/libintpos.so.1

	# Remove obsolete abi subdirectories
	if [ -d $usr/platform/*/lib/abi ]; then
		rm -rf $usr/platform/*/lib/abi
	fi
	rm -rf $usr/lib/gss/abi
	rm -rf $usr/lib/krb5/abi
	rm -rf $usr/xpg4/lib/abi
	rm -rf $usr/ucblib/abi

	#
	# Remove old stuff related to libthread now that libthread has
	# been folded into libc and libthread_db has been renamed libc_db.
	# In addition, all the apptrace's tracing libraries (i.e., abi_*.so*),
	# spec2map and spec2trace are no longer needed, should be removed.
	rm -f	\
	    $usr/lib/mdb/proc/libthread.so		\
	    $usr/lib/mdb/proc/sparcv9/libthread.so	\
	    $usr/lib/abi/spec2map			\
	    $usr/lib/abi/spec2trace			\
	    $usr/lib/abi/abi_*.so*			\
	    $usr/lib/abi/sparcv9/abi_*.so*

	#
	# Remove the old symlink /lib => usr/lib, if necessary.
	# /lib is now a real directory in the root filesystem.
	# Remove all of the old static libraries and commands now
	# that we no longer build them.  If this is a backwards
	# BFU, all this will all be extracted again by cpio.
	rm $root/lib 2>/dev/null
	rm -rf $usr/lib/pics
	rm -rf $usr/sbin/static
	rm -f	\
	    $usr/ccs/lib/libcurses.a			\
	    $usr/ccs/lib/libform.a			\
	    $usr/ccs/lib/libgen.a			\
	    $usr/ccs/lib/libl.a				\
	    $usr/ccs/lib/libmalloc.a			\
	    $usr/ccs/lib/libmenu.a			\
	    $usr/ccs/lib/libpanel.a			\
	    $usr/ccs/lib/libtermcap.a			\
	    $usr/ccs/lib/libtermlib.a			\
	    $usr/ccs/lib/liby.a				\
	    $usr/lib/lib300.a				\
	    $usr/lib/lib300s.a				\
	    $usr/lib/lib4014.a				\
	    $usr/lib/lib450.a				\
	    $usr/lib/libTL.a				\
	    $usr/lib/libadm.a				\
	    $usr/lib/libadt_jni.a			\
	    $usr/lib/libbsdmalloc.a			\
	    $usr/lib/libbsm.a				\
	    $usr/lib/libc.a				\
	    $usr/lib/libc2.a				\
	    $usr/lib/libc2stubs.a			\
	    $usr/lib/libcmd.a				\
	    $usr/lib/libcrypt.a				\
	    $usr/lib/libcrypt_d.a			\
	    $usr/lib/libcrypt_i.a			\
	    $usr/lib/libcurses.a			\
	    $usr/lib/libdevid.a				\
	    $usr/lib/libdevinfo.a			\
	    $usr/lib/libdhcpagent.a			\
	    $usr/lib/libdhcputil.a			\
	    $usr/lib/libdl_stubs.a			\
	    $usr/lib/libefi.a				\
	    $usr/lib/libelf.a				\
	    $usr/lib/libform.a				\
	    $usr/lib/libgen.a				\
	    $usr/lib/libgenIO.a				\
	    $usr/lib/libike.a				\
	    $usr/lib/libinetcfg.a			\
	    $usr/lib/libinetutil.a			\
	    $usr/lib/libintl.a				\
	    $usr/lib/libkstat.a				\
	    $usr/lib/libl.a				\
	    $usr/lib/libldfeature.a			\
	    $usr/lib/libmail.a				\
	    $usr/lib/libmalloc.a			\
	    $usr/lib/libmapmalloc.a			\
	    $usr/lib/libmenu.a				\
	    $usr/lib/libmeta.a				\
	    $usr/lib/libmp.a				\
	    $usr/lib/libnisdb.a				\
	    $usr/lib/libnls.a				\
	    $usr/lib/libnsl.a				\
	    $usr/lib/libnss_compat.a			\
	    $usr/lib/libnss_dns.a			\
	    $usr/lib/libnss_files.a			\
	    $usr/lib/libnss_nis.a			\
	    $usr/lib/libnss_nisplus.a			\
	    $usr/lib/libp/libc.a			\
	    $usr/lib/libpam.a				\
	    $usr/lib/libpanel.a				\
	    $usr/lib/libplot.a				\
	    $usr/lib/librac.a				\
	    $usr/lib/libresolv.a			\
	    $usr/lib/librpcsvc.a			\
	    $usr/lib/libsec.a				\
	    $usr/lib/libsendfile.a			\
	    $usr/lib/libsocket.a			\
	    $usr/lib/libstraddr.a			\
	    $usr/lib/libtermcap.a			\
	    $usr/lib/libtermlib.a			\
	    $usr/lib/libuuid.a				\
	    $usr/lib/libvolmgt.a			\
	    $usr/lib/libvt0.a				\
	    $usr/lib/libw.a				\
	    $usr/lib/liby.a				\
	    $usr/lib/null.a				\
	    $usr/lib/sparcv9/libadt_jni.a		\
	    $usr/lib/sparcv9/libinetutil.a		\
	    $usr/lib/sparcv9/libldfeature.a		\
	    $usr/lib/sparcv9/libsendfile.a		\
	    $usr/platform/sun4u/lib/libwrsmconf.a	\
	    $usr/ucblib/libcurses.a			\
	    $usr/ucblib/libdbm.a			\
	    $usr/ucblib/libtermcap.a			\
	    $usr/ucblib/libucb.a

	#
	# Remove other obsolete files, too
	rm -f	\
	    $usr/include/table.h			\
	    $usr/include/libgenIO.h			\
	    $usr/lib/llib-lTL				\
	    $usr/lib/llib-lTL.ln

	#
	# libc_psr.so.1 and libmd5_psr.so.1 have been moved
	# from /usr/platform/*/lib to /platform/*/lib.
	# Remove the old files and their containing directories
	rm -f $usr/platform/*/lib/libc_psr.so.1
	rm -f $usr/platform/*/lib/sparcv9/libc_psr.so.1
	rm -f $usr/platform/*/lib/libmd5_psr.so.1
	rm -f $usr/platform/*/lib/sparcv9/libmd5_psr.so.1
	rmdir $usr/platform/*/lib/sparcv9 2>/dev/null
	rmdir $usr/platform/*/lib 2>/dev/null

	#
	# libmd5_psr.so.1 and symlinks to it have been replaced 
	# by libmd_psr.so.1 and thus need to be removed
	rm -f $root/platform/*/lib/libmd5_psr.so.1
	rm -f $root/platform/*/lib/sparcv9/libmd5_psr.so.1

	#
	# Remove obsolete profile libc symlinks
	rm -f $usr/lib/libp/libc.so
	rm -f $usr/lib/libp/sparcv9/libc.so

	#
	# Remove Legacy DR files, now obsolete due to NGDR Phase II putback
	#
	STARFIRE_PLAT=platform/SUNW,Ultra-Enterprise-10000 
		rm -f \
		$root/$STARFIRE_PLAT/kernel/drv/dr		\
		$root/$STARFIRE_PLAT/kernel/drv/dr.conf		\
		$root/$STARFIRE_PLAT/kernel/misc/drmach		\
		$root/$STARFIRE_PLAT/kernel/drv/sparcv9/dr	\
		$root/$STARFIRE_PLAT/kernel/misc/sparcv9/drmach	\
		$root/$STARFIRE_PLAT/lib/dr_daemon		\
		$usr/platform/sun4u/include/sys/dr.h	\
		$usr/platform/sun4u/include/sys/sfdr.h

	# Remove obsolete OPL platform links.
		rm -f $root/platform/FJSV,SPARC-Enterprise
		rm -f $root/platform/SUNW,OPL-Enterprise
		rm -f $usr/platform/FJSV,SPARC-Enterprise
		rm -f $usr/platform/SUNW,OPL-Enterprise

	# Solstice Enterprise Agent(SEA) : mib-II subagent mibiisa
	# needs to be disabled during startup. SMA(System Management Agent)
	# has the capability to support mib-II requests.
	# The correct ones will be extracted from
	# the archives whether bfu'ing backwards or forwards.
	#
	# old: need to remove going forwards:
	rm -f $root/etc/snmp/conf/mibiisa.rsrc
	#
	# new: need to remove going backwards:
	rm -f $root/etc/snmp/conf/mibiisa.rsrc-

	# remove old terminal emulator module:
	# (renamed from 'terminal-emulator' to 'tem')
	#
	# old: need to remove going forwards:
	rm -f $root/kernel/misc/terminal-emulator
	rm -f $root/kernel/misc/amd64/terminal-emulator
	#
	# new: need to remove going backwards:
	rm -f $root/kernel/misc/tem
	rm -f $root/kernel/misc/amd64/tem
	rm -f $root/kernel/misc/sparcv9/tem

	#
	# Remove /dev/mc symlink and /platform/sun4u/kernel/drv/mc-us3.conf
	# if any.
	#
	if [ -h $root/dev/mc ]; then
		rm -f $root/dev/mc
	fi

	if [ -f $root/platform/sun4u/kernel/drv/mc-us3.conf ]; then
		rm -f $root/platform/sun4u/kernel/drv/mc-us3.conf
	fi

	#
	# Remove the snowbird sbin and include symlinks
	#

	if [[ -h $usr/platform/SUNW,Netra-CP2300/sbin ]] ; then
		rm -f $usr/platform/SUNW,Netra-CP2300/sbin
	fi

	if [[ -h $usr/platform/SUNW,Netra-CP2300/include ]] ; then
		rm -f $usr/platform/SUNW,Netra-CP2300/include
	fi

	# If we still have the old lp(7D) driver, remove it and its symlinks
	# and header file. (If driver already gone, don't trample new symlinks.)
	#
	if [ -f $root/platform/i86pc/kernel/drv/lp -a \
	    -h $root/dev/lp[012] ]; then
		rm -f $root/dev/lp[012]
	fi
	rm -f $root/platform/i86pc/kernel/drv/lp.conf
	rm -f $root/platform/i86pc/kernel/drv/lp
	rm -f $root/usr/include/sys/lp.h

	#
	# Remove V880 CPU DR files, program cancelled
	#
	DAKTARI_PLAT=platform/SUNW,Sun-Fire-880
		rm -f \
		$root/$DAKTARI_PLAT/kernel/drv/gptwo.conf	\
		$root/$DAKTARI_PLAT/kernel/drv/sparcv9/bbc	\
		$root/$DAKTARI_PLAT/kernel/drv/sparcv9/gptwo	\
		$root/$DAKTARI_PLAT/kernel/misc/sparcv9/sbdp	\
		$usr/platform/sun4u/include/sys/sbdp.h

	#
	# Remove crash(1M), now obsoleted by mdb(1).  If this is a backwards
	# BFU, it will be extracted again by cpio.
	#
	rm -f $root/etc/crash $usr/sbin/crash $usr/sbin/i86/crash \
	    $usr/sbin/sparcv7/crash $usr/sbin/sparcv9/crash

	#
	# Remove kadb(1M), now obsoleted by kmdb(1M)
	#
	rm -f $root/platform/*/kadb

	#
	# Remove old platform dmod symlinks
	#
	for dir in $usr/platform/*/lib/mdb ; do
		[[ -h $dir ]] && rm -f $dir
	done

	#
	# Remove ADB macros
	#
	rm -fr $usr/lib/adb

	for dir in $usr/platform/*/lib/adb ; do
		rm -fr $dir
	done

	#
	# Remove the SGENV driver from the Sun-Fire directory structure.
	# If this is a backwards BFU, it will be extracted again by cpio.
	#
	SERENGETI_PLAT=platform/SUNW,Sun-Fire
	rm -f $root/$SERENGETI_PLAT/kernel/drv/sgenv.conf \
	    $root/$SERENGETI_PLAT/kernel/drv/sparcv9/sgenv

	#
	# Remove sun4m
	#
	rm -rf $root/platform/sun4m
	rm -rf $usr/platform/sun4m
	if [ $target_isa = sparc ]; then
		rm -f $root/kernel/genunix
	fi
	rm -f $root/kernel/drv/xbox
	rm -f $usr/include/sys/comvec.h
	rm -f $usr/include/sys/openprom.h
	rm -f $usr/include/sys/cg14io.h
	rm -f $usr/include/sys/cg14reg.h
	rm -f $usr/include/sys/cg8reg.h
	rm -f $usr/include/sys/cg8var.h

	#
	# Remove perl 5.005_03.  If this is a backwards bfu,
	# it will be extracted again by cpio.
	#
	if [[ -d $usr/perl5/5.00503 ]]; then
		remove_perl_500503
	fi

	#
	# Remove perl 5.8.3, but only if the generic.usr archive contains 5.8.4.
	# If this is a backwards bfu, 5.8.3 will be extracted again by cpio.
	#
	if [[ -d $usr/perl5/5.8.3 ]] && $ZCAT $cpiodir/generic.usr$ZFIX | \
	    cpio -it 2>/dev/null |  egrep -s '^usr/perl5/5.8.4/'; then
		remove_perl_583
	fi

	#
	# Clean up legacy versions of the FMA CPU/Mem DE which may be still
	# be laying around.  This check may be removed when a sufficient time
	# has lapsed between the FMA putback as to ensure that no test machines
	# still have development FMA bits.
	#
	for platdir in $usr/platform/SUNW,* ; do
		[[ -h $platdir ]] && continue

		rm -f $platdir/lib/fm/fmd/plugins/cpumem-diagnosis.so
		rm -f $platdir/lib/fm/fmd/plugins/cpumem-diagnosis.conf 
	done

	#
	# Clean up legacy versions of x4500 FMA modules which may be still
	# be laying around.  This check may be removed when a sufficient time
	# has lapsed between the FMA putback as to ensure that no test machines
	# still have development FMA bits.
	#
	rm -f $usr/platform/i86pc/lib/fm/topo/plugins/sata.so
	rm -f $usr/platform/i86pc/lib/fm/topo/maps/storage-hc-topology.xml
	rm -f $usr/platform/i86pc/lib/fm/fmd/plugins/sfx4500-disk.so
	rm -f $usr/platform/i86pc/lib/fm/fmd/plugins/sfx4500-disk.conf

	# Remove pam_unix
	#
	rm -f $usr/lib/security/pam_unix.so.1
	rm -f $usr/lib/security/pam_unix.so
	rm -f $usr/lib/security/sparcv9/pam_unix.so.1
	rm -f $usr/lib/security/sparcv9/pam_unix.so

	#
	# Remove pam_projects
	rm -f $usr/lib/security/pam_projects.so.1
	rm -f $usr/lib/security/pam_projects.so
	rm -f $usr/lib/security/64/pam_projects.so.1
	rm -f $usr/lib/security/64/pam_projects.so

	#
	# Remove libldap.so.3
	#
	rm -f $usr/lib/libldap.so.3
	rm -f $usr/lib/sparcv9/libldap.so.3

	#
	# Remove nss XFN support no longer used by printing
	#
	sed -e '/printers:/s/xfn[  ]*//' \
		$rootprefix/bfu.child/etc/nsswitch.conf > /tmp/nssw.$$
	cp /tmp/nssw.$$ $rootprefix/bfu.child/etc/nsswitch.conf
	rm -f /tmp/nssw.$$
	rm -f $usr/lib/nss_xfn.so.1
	rm -f $usr/lib/sparcv9/nss_xfn.so.1

	#
	# Remove FNS/XFN.
	#
	if [ -d $rootprefix/etc/fn -o \
	     -d $usr/include/xfn -o \
	     -d $usr/lib/fn -o \
	     -d $rootprefix/var/fn ]; then
		remove_eof_fns
	fi

	#
	# Remove AT&T FACE
	#
	if [ -d $usr/oasys -o -d $usr/vmsys ]; then
		remove_eof_face
	fi

	#
	# Remove DMI
	#
	if [ -d $usr/lib/dmi -o \
	     -d $rootprefix/etc/dmi -o \
	     -d $rootprefix/var/dmi ]; then
	        remove_eof_dmi
	fi

	#
	# Remove Wildcat
	#
	if [ -f $rootprefix/platform/SUNW,Sun-Fire-15000/kernel/misc/sparcv9/gptwo_wci -o \
	     -f $usr/platform/SUNW,Sun-Fire/lib/rsmlib/wrsm.so.1 -o \
	     -f $rootprefix/platform/sun4u/kernel/drv/wrsmd.conf -o \
	     -d $rootprefix/etc/wrsm -o \
	     -f $usr/platform/sun4u/sbin/wrsmstat ]; then
		remove_eof_wildcat
	fi

	#
	# Remove ASET
	#
	if [ -d $usr/aset ]; then
		remove_eof_aset
	fi

	#
	# Remove BIND 8, but only if the generic.usr archive doesn't contains
	# BIND 8 named server/tools. If this is a backwards bfu, BIND 8 will
	# be extracted again by cpio.
	#
	if [[ -f $usr/sbin/dnskeygen ]] && ! $ZCAT $cpiodir/generic.usr$ZFIX \
	    | cpio -it 2>/dev/null |  egrep -s '^usr/sbin/ndc' ; then
		remove_eof_bind8
	fi

	#
	# Remove any sendmailvars: line from /etc/nsswitch.conf
	#
	sed -e '/^sendmailvars:/d' $rootprefix/bfu.child/etc/nsswitch.conf > \
		/tmp/nssw.$$
	cp /tmp/nssw.$$ $rootprefix/bfu.child/etc/nsswitch.conf
	rm -f /tmp/nssw.$$

	#
	# Remove vold
	#
	if [ -f $rootprefix/etc/vold.conf -o -d $usr/lib/vold ]; then
		remove_eof_vold
	fi

	#
	# Remove obsolete Mobile IP software
	#
	if [[ -f $rootprefix/etc/init.d/mipagent || \
	    -f $rootprefix/usr/lib/inet/mipagent ]]; then
		remove_eof_mobileip
	fi

	#
	# Remove SUNWcoff package
	#
	pkg=SUNWcoff
	if [ $target_isa = i386 ]; then
		if pkginfo $pkgroot -q $pkg; then
			pkgrm $pkgroot -n $pkg >/dev/null 2>&1
		fi

		# In case that did not work, do it manually.
		if [ -d $rootprefix/var/sadm/pkg/$pkg ]; then
			rm -rf $rootprefix/var/sadm/pkg/$pkg
			rm $rootprefix/kernel/exec/coffexec
		fi
	fi

	#
	# Remove GMT* zoneinfo files
	#
	rm -f $usr/share/lib/zoneinfo/GMT-12
	rm -f $usr/share/lib/zoneinfo/GMT-11
	rm -f $usr/share/lib/zoneinfo/GMT-10
	rm -f $usr/share/lib/zoneinfo/GMT-9
	rm -f $usr/share/lib/zoneinfo/GMT-8
	rm -f $usr/share/lib/zoneinfo/GMT-7
	rm -f $usr/share/lib/zoneinfo/GMT-6
	rm -f $usr/share/lib/zoneinfo/GMT-5
	rm -f $usr/share/lib/zoneinfo/GMT-4
	rm -f $usr/share/lib/zoneinfo/GMT-3
	rm -f $usr/share/lib/zoneinfo/GMT-2
	rm -f $usr/share/lib/zoneinfo/GMT-1
	rm -f $usr/share/lib/zoneinfo/GMT+1
	rm -f $usr/share/lib/zoneinfo/GMT+2
	rm -f $usr/share/lib/zoneinfo/GMT+3
	rm -f $usr/share/lib/zoneinfo/GMT+4
	rm -f $usr/share/lib/zoneinfo/GMT+5
	rm -f $usr/share/lib/zoneinfo/GMT+6
	rm -f $usr/share/lib/zoneinfo/GMT+7
	rm -f $usr/share/lib/zoneinfo/GMT+8
	rm -f $usr/share/lib/zoneinfo/GMT+9
	rm -f $usr/share/lib/zoneinfo/GMT+10
	rm -f $usr/share/lib/zoneinfo/GMT+11
	rm -f $usr/share/lib/zoneinfo/GMT+12
	rm -f $usr/share/lib/zoneinfo/GMT+13

	# Remove stc(7d)-related files
	rm -f $usr/include/sys/stcio.h
	rm -f $usr/include/sys/stcvar.h
	rm -f $usr/include/sys/stcreg.h
	rm -f $usr/include/sys/stcconf.h
	SUN4U_DRV=platform/sun4u/kernel/drv
	rm -f $rootprefix/$SUN4U_DRV/stc.conf
	rm -f $rootprefix/$SUN4U_DRV/stc
	rm -f $rootprefix/$SUN4U_DRV/sparcv9/stc

	# Remove old CPC adb macros.
	rm -f $usr/lib/adb/cpc_ctx
	rm -f $usr/lib/adb/cpc_event
	if [ $target_isa = sparc ]; then
	    rm -f $usr/lib/adb/sparcv9/cpc_ctx
	    rm -f $usr/lib/adb/sparcv9/cpc_event
	fi;

	# Remove obsolete DTrace demos
	rm -f $usr/demo/dtrace/cputick.d

	# Remove flashprom-related files.
	if [ $target_isa = sparc ]; then
	    for x in $FLASHPROMLIST
	    do
		rm -f $root/$x;
	    done
	fi;

	# Remove pt_chmod - obsoleted by new /dev filesystem
	if [ $zone = global ]; then
	   rm -f $usr/lib/pt_chmod
	fi

	if [ $RM_32BIT_KERNEL -eq 1 -a $zone = global ];
	then
	    print "Removing 32-bit commands and kernel binaries ... \c";
	    rm -rf \
		$usr/bin/sparcv7/amt \
		$usr/bin/sparcv7/cputrack \
		$usr/bin/sparcv7/newtask \
		$usr/bin/sparcv7/nohup \
		$usr/bin/sparcv7/pargs \
		$usr/bin/sparcv7/pcred \
		$usr/bin/sparcv7/pfiles \
		$usr/bin/sparcv7/pflags \
		$usr/bin/sparcv7/pldd \
		$usr/bin/sparcv7/plimit \
		$usr/bin/sparcv7/pmap \
		$usr/bin/sparcv7/ppgsz \
		$usr/bin/sparcv7/ppriv \
		$usr/bin/sparcv7/prctl \
		$usr/bin/sparcv7/preap \
		$usr/bin/sparcv7/prex \
		$usr/bin/sparcv7/prstat \
		$usr/bin/sparcv7/prun \
		$usr/bin/sparcv7/ps \
		$usr/bin/sparcv7/psig \
		$usr/bin/sparcv7/pstack \
		$usr/bin/sparcv7/pstop \
		$usr/bin/sparcv7/ptime \
		$usr/bin/sparcv7/ptree \
		$usr/bin/sparcv7/pwait \
		$usr/bin/sparcv7/pwdx \
		$usr/bin/sparcv7/setuname \
		$usr/bin/sparcv7/sort \
		$usr/bin/sparcv7/tnfxtract \
		$usr/bin/sparcv7/uptime \
		$usr/bin/sparcv7/w \
		$usr/sbin/sparcv7/intrstat \
		$usr/sbin/sparcv7/lockstat \
		$usr/sbin/sparcv7/prtconf \
		$usr/sbin/sparcv7/swap \
		$usr/sbin/sparcv7/sysdef \
		$usr/sbin/sparcv7/whodo \
		$root/kernel/dacf/consconfig_dacf \
		$root/kernel/drv/arp \
		$root/kernel/drv/audiocs \
		$root/kernel/drv/audioens \
		$root/kernel/drv/bofi \
		$root/kernel/drv/bpp \
		$root/kernel/drv/clone \
		$root/kernel/drv/cn \
		$root/kernel/drv/conskbd \
		$root/kernel/drv/consms \
		$root/kernel/drv/dad \
		$root/kernel/drv/devinfo \
		$root/kernel/drv/ecpp \
		$root/kernel/drv/ehci \
		$root/kernel/drv/esp \
		$root/kernel/drv/fas \
		$root/kernel/drv/fcip \
		$root/kernel/drv/fcp \
		$root/kernel/drv/fp \
		$root/kernel/drv/glm \
		$root/kernel/drv/hid \
		$root/kernel/drv/hme \
		$root/kernel/drv/hubd \
		$root/kernel/drv/icmp \
		$root/kernel/drv/icmp6 \
		$root/kernel/drv/ifp \
		$root/kernel/drv/ip \
		$root/kernel/drv/ip6 \
		$root/kernel/drv/ippctl \
		$root/kernel/drv/ipsecah \
		$root/kernel/drv/ipsecesp \
		$root/kernel/drv/isp \
		$root/kernel/drv/iwscn \
		$root/kernel/drv/keysock \
		$root/kernel/drv/le \
		$root/kernel/drv/lebuffer \
		$root/kernel/drv/llc1 \
		$root/kernel/drv/lofi \
		$root/kernel/drv/log \
		$root/kernel/drv/md \
		$root/kernel/drv/mm \
		$root/kernel/drv/mpt \
		$root/kernel/drv/nca \
		$root/kernel/drv/ohci \
		$root/kernel/drv/openeepr \
		$root/kernel/drv/options \
		$root/kernel/drv/pcata \
		$root/kernel/drv/pcelx \
		$root/kernel/drv/pcic \
		$root/kernel/drv/pcmem \
		$root/kernel/drv/pcram \
		$root/kernel/drv/pcs \
		$root/kernel/drv/pcser \
		$root/kernel/drv/pem \
		$root/kernel/drv/pln \
		$root/kernel/drv/poll \
		$root/kernel/drv/pseudo \
		$root/kernel/drv/ptc \
		$root/kernel/drv/ptsl \
		$root/kernel/drv/qlc \
		$root/kernel/drv/random \
		$root/kernel/drv/rts \
		$root/kernel/drv/sad \
		$root/kernel/drv/scsa2usb \
		$root/kernel/drv/scsi_vhci \
		$root/kernel/drv/sd \
		$root/kernel/drv/se \
		$root/kernel/drv/ses \
		$root/kernel/drv/sgen \
		$root/kernel/drv/soc \
		$root/kernel/drv/socal \
		$root/kernel/drv/spdsock \
		$root/kernel/drv/ssd \
		$root/kernel/drv/st \
		$root/kernel/drv/stp4020 \
		$root/kernel/drv/sy \
		$root/kernel/drv/sysmsg \
		$root/kernel/drv/tcp \
		$root/kernel/drv/tcp6 \
		$root/kernel/drv/tl \
		$root/kernel/drv/uata \
		$root/kernel/drv/udp \
		$root/kernel/drv/udp6 \
		$root/kernel/drv/ugen \
		$root/kernel/drv/usb_ac \
		$root/kernel/drv/usb_as \
		$root/kernel/drv/usb_mid \
		$root/kernel/drv/usbprn \
		$root/kernel/drv/usbser_edge \
		$root/kernel/drv/usoc \
		$root/kernel/drv/wc \
		$root/kernel/exec/aoutexec \
		$root/kernel/exec/elfexec \
		$root/kernel/exec/intpexec \
		$root/kernel/fs/autofs \
		$root/kernel/fs/cachefs \
		$root/kernel/fs/devfs \
		$root/kernel/fs/fifofs \
		$root/kernel/fs/hsfs \
		$root/kernel/fs/lofs \
		$root/kernel/fs/mntfs \
		$root/kernel/fs/nfs \
		$root/kernel/fs/procfs \
		$root/kernel/fs/sockfs \
		$root/kernel/fs/specfs \
		$root/kernel/fs/tmpfs \
		$root/kernel/fs/udfs \
		$root/kernel/fs/ufs \
		$root/kernel/ipp/dlcosmk \
		$root/kernel/ipp/dscpmk \
		$root/kernel/ipp/flowacct \
		$root/kernel/ipp/ipgpc \
		$root/kernel/ipp/tokenmt \
		$root/kernel/ipp/tswtclmt \
		$root/kernel/misc/amsrc1 \
		$root/kernel/misc/audiosup \
		$root/kernel/misc/busra \
		$root/kernel/misc/consconfig \
		$root/kernel/misc/dada \
		$root/kernel/misc/des \
		$root/kernel/misc/diaudio \
		$root/kernel/misc/fctl \
		$root/kernel/misc/fssnap_if \
		$root/kernel/misc/gld \
		$root/kernel/misc/hidparser \
		$root/kernel/misc/hpcsvc \
		$root/kernel/misc/ipc \
		$root/kernel/misc/kbtrans \
		$root/kernel/misc/kgss/do_kmech_krb5 \
		$root/kernel/misc/kgss/gl_kmech_krb5 \
		$root/kernel/misc/kgssapi \
		$root/kernel/misc/klmmod \
		$root/kernel/misc/klmops \
		$root/kernel/misc/krtld \
		$root/kernel/misc/md5 \
		$root/kernel/misc/md_hotspares \
		$root/kernel/misc/md_mirror \
		$root/kernel/misc/md_notify \
		$root/kernel/misc/md_raid \
		$root/kernel/misc/md_sp \
		$root/kernel/misc/md_stripe \
		$root/kernel/misc/md_trans \
		$root/kernel/misc/mixer \
		$root/kernel/misc/mpxio \
		$root/kernel/misc/nfs_dlboot \
		$root/kernel/misc/nfssrv \
		$root/kernel/misc/pcicfg \
		$root/kernel/misc/pcihp \
		$root/kernel/misc/phx \
		$root/kernel/misc/rpcsec \
		$root/kernel/misc/rpcsec_gss \
		$root/kernel/misc/rsmops \
		$root/kernel/misc/scsi \
		$root/kernel/misc/seg_drv \
		$root/kernel/misc/seg_mapdev \
		$root/kernel/misc/sha1 \
		$root/kernel/misc/strplumb \
		$root/kernel/misc/swapgeneric \
		$root/kernel/misc/tlimod \
		$root/kernel/misc/ufs_log \
		$root/kernel/misc/usba \
		$root/kernel/misc/usbser \
		$root/kernel/sched/TS \
		$root/kernel/sched/TS_DPTBL \
		$root/kernel/strmod/6to4tun \
		$root/kernel/strmod/arp \
		$root/kernel/strmod/atun \
		$root/kernel/strmod/authmd5h \
		$root/kernel/strmod/authsha1 \
		$root/kernel/strmod/bufmod \
		$root/kernel/strmod/connld \
		$root/kernel/strmod/dedump \
		$root/kernel/strmod/drcompat \
		$root/kernel/strmod/encr3des \
		$root/kernel/strmod/encraes \
		$root/kernel/strmod/encrbfsh \
		$root/kernel/strmod/encrdes \
		$root/kernel/strmod/icmp \
		$root/kernel/strmod/ip \
		$root/kernel/strmod/ipsecah \
		$root/kernel/strmod/ipsecesp \
		$root/kernel/strmod/keysock \
		$root/kernel/strmod/ldterm \
		$root/kernel/strmod/ms \
		$root/kernel/strmod/nca \
		$root/kernel/strmod/pckt \
		$root/kernel/strmod/pfmod \
		$root/kernel/strmod/pipemod \
		$root/kernel/strmod/ptem \
		$root/kernel/strmod/redirmod \
		$root/kernel/strmod/rpcmod \
		$root/kernel/strmod/rts \
		$root/kernel/strmod/tcp \
		$root/kernel/strmod/timod \
		$root/kernel/strmod/tirdwr \
		$root/kernel/strmod/ttcompat \
		$root/kernel/strmod/tun \
		$root/kernel/strmod/udp \
		$root/kernel/strmod/usb_ah \
		$root/kernel/strmod/usbkbm \
		$root/kernel/strmod/usbms \
		$root/kernel/sys/c2audit \
		$root/kernel/sys/doorfs \
		$root/kernel/sys/inst_sync \
		$root/kernel/sys/kaio \
		$root/kernel/sys/msgsys \
		$root/kernel/sys/nfs \
		$root/kernel/sys/pipe \
		$root/kernel/sys/pset \
		$root/kernel/sys/rpcmod \
		$root/kernel/sys/semsys \
		$root/kernel/sys/shmsys \
		$root/platform/SUNW,Ultra-250/kernel/drv/envctrltwo \
		$root/platform/SUNW,Ultra-250/kernel/misc/platmod \
		$root/platform/SUNW,Ultra-4/kernel/drv/envctrl \
		$root/platform/SUNW,Ultra-4/kernel/misc/platmod \
		$root/platform/SUNW,Ultra-5_10/kernel/misc/platmod \
		$root/platform/SUNW,Ultra-80/kernel/misc/platmod \
		$root/platform/SUNW,Ultra-Enterprise-10000/kernel/cpu/SUNW,UltraSPARC \
		$root/platform/SUNW,Ultra-Enterprise-10000/kernel/cpu/SUNW,UltraSPARC-II \
		$root/platform/SUNW,Ultra-Enterprise-10000/kernel/drv/cvc \
		$root/platform/SUNW,Ultra-Enterprise-10000/kernel/drv/cvcredir \
		$root/platform/SUNW,Ultra-Enterprise-10000/kernel/drv/idn \
		$root/platform/SUNW,Ultra-Enterprise-10000/kernel/drv/ngdr \
		$root/platform/SUNW,Ultra-Enterprise-10000/kernel/drv/pcipsy \
		$root/platform/SUNW,Ultra-Enterprise-10000/kernel/drv/rootnex \
		$root/platform/SUNW,Ultra-Enterprise-10000/kernel/drv/sbus \
		$root/platform/SUNW,Ultra-Enterprise-10000/kernel/misc/ngdrmach \
		$root/platform/SUNW,Ultra-Enterprise-10000/kernel/misc/platmod \
		$root/platform/SUNW,Ultra-Enterprise-10000/kernel/unix \
		$root/platform/SUNW,Ultra-Enterprise/kernel/drv/ac \
		$root/platform/SUNW,Ultra-Enterprise/kernel/drv/central \
		$root/platform/SUNW,Ultra-Enterprise/kernel/drv/environ \
		$root/platform/SUNW,Ultra-Enterprise/kernel/drv/fhc \
		$root/platform/SUNW,Ultra-Enterprise/kernel/drv/simmstat \
		$root/platform/SUNW,Ultra-Enterprise/kernel/drv/sram \
		$root/platform/SUNW,Ultra-Enterprise/kernel/drv/sysctrl \
		$root/platform/SUNW,Ultra-Enterprise/kernel/misc/platmod \
		$root/platform/sun4u/boot.conf \
		$root/platform/sun4u/kernel/cpu/SUNW,UltraSPARC \
		$root/platform/sun4u/kernel/cpu/SUNW,UltraSPARC-II \
		$root/platform/sun4u/kernel/cpu/SUNW,UltraSPARC-III \
		$root/platform/sun4u/kernel/cpu/SUNW,UltraSPARC-III+ \
		$root/platform/sun4u/kernel/cpu/SUNW,UltraSPARC-IIIi \
		$root/platform/sun4u/kernel/cpu/SUNW,UltraSPARC-IIe \
		$root/platform/sun4u/kernel/cpu/SUNW,UltraSPARC-IIi \
		$root/platform/sun4u/kernel/cpu/SUNW,UltraSPARC-IV \
		$root/platform/sun4u/kernel/drv/bwtwo \
		$root/platform/sun4u/kernel/drv/cgsix \
		$root/platform/sun4u/kernel/drv/cgthree \
		$root/platform/sun4u/kernel/drv/cpc \
		$root/platform/sun4u/kernel/drv/db21554 \
		$root/platform/sun4u/kernel/drv/dma \
		$root/platform/sun4u/kernel/drv/ebus \
		$root/platform/sun4u/kernel/drv/fd \
		$root/platform/sun4u/kernel/drv/ledma \
		$root/platform/sun4u/kernel/drv/memtest \
		$root/platform/sun4u/kernel/drv/pci_pci \
		$root/platform/sun4u/kernel/drv/pcipsy \
		$root/platform/sun4u/kernel/drv/power \
		$root/platform/sun4u/kernel/drv/rootnex \
		$root/platform/sun4u/kernel/drv/sbbc \
		$root/platform/sun4u/kernel/drv/sbus \
		$root/platform/sun4u/kernel/drv/sbusmem \
		$root/platform/sun4u/kernel/drv/sf \
		$root/platform/sun4u/kernel/drv/simba \
		$root/platform/sun4u/kernel/drv/su \
		$root/platform/sun4u/kernel/drv/tod \
		$root/platform/sun4u/kernel/drv/trapstat \
		$root/platform/sun4u/kernel/drv/zs \
		$root/platform/sun4u/kernel/drv/zsh \
		$root/platform/sun4u/kernel/genunix \
		$root/platform/sun4u/kernel/misc/bootdev \
		$root/platform/sun4u/kernel/misc/cpr \
		$root/platform/sun4u/kernel/misc/forthdebug \
		$root/platform/sun4u/kernel/misc/kgss/do_kmech_krb5 \
		$root/platform/sun4u/kernel/misc/kgss/gl_kmech_krb5 \
		$root/platform/sun4u/kernel/misc/md5 \
		$root/platform/sun4u/kernel/misc/obpsym \
		$root/platform/sun4u/kernel/misc/pcmcia \
		$root/platform/sun4u/kernel/misc/platmod \
		$root/platform/sun4u/kernel/misc/vis \
		$root/platform/sun4u/kernel/strmod/kb \
		$root/platform/sun4u/kernel/sys/cpc \
		$root/platform/sun4u/kernel/tod/todmostek \
		$root/platform/sun4u/kernel/tod/todstarfire \
		$usr/include/v7/sys/mon_clock.h \
		$usr/kernel/drv/dump \
		$usr/kernel/drv/fssnap \
		$usr/kernel/drv/gen_drv \
		$usr/kernel/drv/kstat \
		$usr/kernel/drv/ksyms \
		$usr/kernel/drv/llc2 \
		$usr/kernel/drv/lo \
		$usr/kernel/drv/lockstat \
		$usr/kernel/drv/logindmux \
		$usr/kernel/drv/pm \
		$usr/kernel/drv/pshot \
		$usr/kernel/drv/ptm \
		$usr/kernel/drv/pts \
		$usr/kernel/drv/rsm \
		$usr/kernel/drv/sppp \
		$usr/kernel/drv/sppptun \
		$usr/kernel/drv/sysevent \
		$usr/kernel/drv/tidg \
		$usr/kernel/drv/tivc \
		$usr/kernel/drv/tmux \
		$usr/kernel/drv/tnf \
		$usr/kernel/drv/vol \
		$usr/kernel/drv/winlock \
		$usr/kernel/exec/javaexec \
		$usr/kernel/fs/fdfs \
		$usr/kernel/fs/namefs \
		$usr/kernel/fs/pcfs \
		$usr/kernel/sched/FSS \
		$usr/kernel/sched/FX \
		$usr/kernel/sched/FX_DPTBL \
		$usr/kernel/sched/IA \
		$usr/kernel/sched/RT \
		$usr/kernel/sched/RT_DPTBL \
		$usr/kernel/strmod/cryptmod \
		$usr/kernel/strmod/lmodb \
		$usr/kernel/strmod/lmode \
		$usr/kernel/strmod/lmodr \
		$usr/kernel/strmod/lmodt \
		$usr/kernel/strmod/rlmod \
		$usr/kernel/strmod/spppasyn \
		$usr/kernel/strmod/spppcomp \
		$usr/kernel/strmod/sppptun \
		$usr/kernel/strmod/telmod \
		$usr/kernel/sys/acctctl \
		$usr/kernel/sys/exacctsys \
		$usr/kernel/sys/sysacct \
		$usr/lib/gss/mech_spnego.so \
		$usr/lib/gss/mech_spnego.so.1 \
		$usr/lib/mdb/kvm/cpc.so \
		$usr/lib/mdb/kvm/genunix.so \
		$usr/lib/mdb/kvm/ip.so \
		$usr/lib/mdb/kvm/ipc.so \
		$usr/lib/mdb/kvm/ipp.so \
		$usr/lib/mdb/kvm/isp.so \
		$usr/lib/mdb/kvm/krtld.so \
		$usr/lib/mdb/kvm/lofs.so \
		$usr/lib/mdb/kvm/logindmux.so \
		$usr/lib/mdb/kvm/mdb_ks.so \
		$usr/lib/mdb/kvm/nca.so \
		$usr/lib/mdb/kvm/nfs.so \
		$usr/lib/mdb/kvm/ptm.so \
		$usr/lib/mdb/kvm/random.so \
		$usr/lib/mdb/kvm/sd.so \
		$usr/lib/mdb/kvm/sppp.so \
		$usr/lib/mdb/kvm/ssd.so \
		$usr/lib/mdb/kvm/ufs_log.so \
		$usr/lib/mdb/kvm/usba.so \
		$usr/lib/sparcv9/gss/mech_spnego.so \
		$usr/lib/sparcv9/gss/mech_spnego.so.1 \
		$usr/platform/SUNW,Ultra-1 \
		$usr/platform/SUNW,Ultra-250/doc \
		$usr/platform/SUNW,Ultra-250/lib/flash-update.sh \
		$usr/platform/SUNW,Ultra-250/lib/prom \
		$usr/platform/SUNW,Ultra-Enterprise-10000/doc \
		$usr/platform/SUNW,Ultra-Enterprise-10000/lib/flash-update.sh \
		$usr/platform/SUNW,Ultra-Enterprise-10000/lib/prom \
		$usr/platform/sun4u/lib/mdb/kvm/unix.so \
		$usr/platform/sun4u/lib/prom/SUNW,Ultra-1 > /dev/null 2>&1;
		print "done.";
	fi;

	#
	# Remove kmdbmod from /kernel
	#
	rm -f $root/kernel/misc/sparcv9/kmdbmod

	#
	# Remove obsolete drivers/header files as a result of sun4v source
	# code reorg
	#
	rm -f $root/platform/sun4u/kernel/drv/sparcv9/pci_pci
	rm -f $root/platform/sun4u/kernel/misc/sparcv9/pcmcia
	rm -f $usr/include/v9/sys/traptrace.h
	rm -f $usr/platform/sun4u/include/sys/spitasi.h
	rm -f $usr/kernel/pcbe/sparcv9/pcbe.SUNW,UltraSPARC-T1

	#
        # Remove the IPsec encryption and authentication modules.
        # IPsec now uses the Kernel Crypto Framework for crypto.
        #
        rm -f $rootprefix/kernel/strmod/encr3des
        rm -f $rootprefix/kernel/strmod/encrdes
        rm -f $rootprefix/kernel/strmod/encrbfsh
        rm -f $rootprefix/kernel/strmod/encraes
        rm -f $rootprefix/kernel/strmod/authmd5h
        rm -f $rootprefix/kernel/strmod/authsha1
        rm -f $rootprefix/kernel/strmod/sparcv9/encr3des
        rm -f $rootprefix/kernel/strmod/sparcv9/encrdes
        rm -f $rootprefix/kernel/strmod/sparcv9/encrbfsh
        rm -f $rootprefix/kernel/strmod/sparcv9/encraes
        rm -f $rootprefix/kernel/strmod/sparcv9/authmd5h
        rm -f $rootprefix/kernel/strmod/sparcv9/authsha1

	#
	# Remove the now-obsolete "nattymod" STREAMS module.
	#
	rm -f $rootprefix/kernel/strmod/nattymod
	rm -f $rootprefix/kernel/strmod/amd64/nattymod
	rm -f $rootprefix/kernel/strmod/sparcv9/nattymod

        #
        # Remove obsolete SSA utility, firmware and fcode.
        # usr/lib/firmware/ssa contains ssafirmware 
        #
        rm -rf $usr/lib/firmware/ssa
        rm -f $usr/lib/firmware/fc_s/fc_s_fcode
        rm -f $usr/sbin/ssaadm

	#
	# Remove seg_drv, seg_mapdev driver
	#
	rm -f $root/kernel/misc/seg_drv
	rm -f $root/kernel/misc/sparcv9/seg_drv
	rm -f $usr/include/sys/seg_drv.h
	rm -f $root/kernel/misc/seg_mapdev
	rm -f $root/kernel/misc/sparcv9/seg_mapdev

	#
	# Remove mpxio module
	#
	rm -f $root/kernel/misc/sparcv9/mpxio

	#
	# Remove mpxio/vhci adb macros.
	#
	if [ $target_isa = sparc -a $zone = global ]; then
		rm -f $usr/lib/adb/mdi_client
		rm -f $usr/lib/adb/sparcv9/mdi_client
		rm -f $usr/lib/adb/mdi_pathinfo
		rm -f $usr/lib/adb/sparcv9/mdi_pathinfo
		rm -f $usr/lib/adb/mdi_phci
		rm -f $usr/lib/adb/sparcv9/mdi_phci
		rm -f $usr/lib/adb/mdi_vhci
		rm -f $usr/lib/adb/sparcv9/mdi_vhci
		rm -f $usr/lib/adb/scsi_vhci_pkt
		rm -f $usr/lib/adb/sparcv9/scsi_vhci_pkt
		rm -f $usr/lib/adb/scsi_vhci_softstate
		rm -f $usr/lib/adb/sparcv9/scsi_vhci_softstate
	fi

	#
	# Diskless clients have already extracted /usr so don't delete this
	# Non-global zones never extracts /usr so don't delete these
	#
	if [ $diskless = no -a $zone = global ]; then
		rm -f $usr/sbin/stmsboot

		rm -f $usr/lib/mdb/kvm/mpxio.so
		rm -f $usr/lib/mdb/kvm/sparcv9/mpxio.so
		rm -f $usr/lib/mdb/kvm/amd64/mpxio.so
		rm -f $usr/lib/mdb/kvm/scsi_vhci.so
		rm -f $usr/lib/mdb/kvm/sparcv9/scsi_vhci.so
		rm -f $usr/lib/mdb/kvm/amd64/scsi_vhci.so
	fi
	rm -f $root/lib/mpxio/mpxio
	rm -f $root/lib/mpxio/stmsboot_util

	rm -f $root/kernel/kmdb/mpxio
	rm -f $root/kernel/kmdb/sparcv9/mpxio
	rm -f $root/kernel/kmdb/amd64/mpxio
	rm -f $root/kernel/kmdb/scsi_vhci
	rm -f $root/kernel/kmdb/sparcv9/scsi_vhci
	rm -f $root/kernel/kmdb/amd64/scsi_vhci

	#
	# Remove rpcib misc module (converted to driver)
	#
	rm -f $root/kernel/misc/sparcv9/rpcib
	rm -f $root/kernel/drv/sparcv9/rpcib

	#
	# Remove old smartcard header files
	#

	rm -f \
		$usr/include/smartcard.h \
		$usr/include/smartcard/ocf_authenticate.h \
		$usr/include/smartcard/ocf_core.h \
		$usr/include/smartcard/ocf_core_cardservices.h

	#
	# Remove smartcard libraries that should not have been shipped.
	#
	rm -rf  $usr/lib/smartcard/sparcv9/ \
		$usr/share/lib/smartcard/scmtester.jar

	#
	# Remove external smartcard reader driver
	#
	rm -f $usr/share/lib/smartcard/scmrsr3.jar

	#
	# Remove old internal smartcard reader driver
	#
	rm -f $usr/share/lib/smartcard/scmiscr.jar
	rm -f $usr/lib/smartcard/libSCMI2CNative.so
	rm -f $usr/lib/smartcard/libSCMI2CNative.so.1

	#
	# Remove Smart OS
	#
	rm -f $usr/share/lib/smartcard/smartos.jar

	#
	# Remove drivers & header files for EOL of soc & pln drivers
	# as per PSARC/2003/233
	#
	rm -f $root/kernel/drv/pln.conf
	rm -f $root/kernel/drv/sparcv9/pln
	rm -f $root/kernel/drv/sparcv9/soc
	rm -f $usr/include/sys/socvar.h
	rm -f $usr/include/sys/socmap.h
	rm -f $usr/include/sys/soc_cq_defs.h
	rm -f $usr/include/sys/socreg.h
	rm -f $usr/include/sys/scsi/adapters/plndef.h
	rm -f $usr/include/sys/scsi/adapters/plnvar.h
	rm -f $usr/include/sys/scsi/adapters/ssaisp.h
	rm -f $usr/include/sys/scsi/targets/pln_ctlr.h
	rm -f $usr/include/sys/scsi/targets/osesio.h

	#
	# PSARC/2003/629 Common Solaris Target Disk Driver
	# remove adb macro "scsi_disk" for the x86 platform
	#
	if [ $target_isa = i386 ]; then
		rm -f $usr/lib/adb/scsi_disk
	fi

	# Remove CPCv1 API header per PSARC/2004/648
	rm -f $usr/include/sys/cpc_event.h

	# Remove headers per PSARC/2005/561
	rm -f $usr/include/sys/nexusintr.h
	rm -f $usr/platform/sun4u/include/sys/nexusintr_impl.h
	rm -f $usr/platform/sun4v/include/sys/nexusintr_impl.h

	# Remove usr/lib/mail which has moved to etc/mail/cf, but first,
	# attempt to migrate any user-added files, which primarily live
	# under usr/lib/mail/cf .  Blow away the seven files which we
	# ship under that directory, then move any that remain to the
	# new location, which we will `mkdir -p` just to be safe.
	# If the zone in question is non-global, then skip all this.
	#
	if [ $zone = "global" ]; then
		# -d follow sym-links: make sure it's not a link.
		if [ -d $usr/lib/mail -a ! -h $usr/lib/mail ]; then
			# Only do this if usr/lib/mail is still a directory;
			# bfu'ing backwards does not merit such migration.
			rm -f $usr/lib/mail/cf/Makefile
			rm -f $usr/lib/mail/cf/main.cf
			rm -f $usr/lib/mail/cf/main.mc
			rm -f $usr/lib/mail/cf/submit.cf
			rm -f $usr/lib/mail/cf/submit.mc
			rm -f $usr/lib/mail/cf/subsidiary.cf
			rm -f $usr/lib/mail/cf/subsidiary.mc
			mkdir -p -m 0755 $root/etc/mail/cf/cf
			mv $usr/lib/mail/cf/* $root/etc/mail/cf/cf >/dev/null 2>&1
		fi
		rm -rf $usr/lib/mail
	fi

	#
	# Remove drivers and header files for EOF of Lance Ethernet
	# driver(le) as per PSARC/2003/335.
	#
	rm -f $root/kernel/drv/le
	rm -f $root/kernel/drv/sparcv9/le
	rm -f $root/kernel/drv/lebuffer
	rm -f $root/kernel/drv/sparcv9/lebuffer
	rm -f $root/platform/sun4u/kernel/drv/ledma
	rm -f $root/platform/sun4u/kernel/drv/sparcv9/ledma
	rm -f $usr/include/sys/le.h
	rm -f $usr/include/sys/lance.h
	rm -f $usr/lib/adb/le
	rm -f $usr/lib/adb/lestr

	#
	# Remove drivers and header files for EOF of ieef driver as
	# per PSARC/2003/009
	#
	rm -f $root/kernel/drv/ieef
	rm -f $root/kernel/drv/ieef.conf
	rm -f $usr/include/sys/ieef.h
	rm -f $root/boot/solaris/drivers/notisa.010/ieef.bef

	#
	# Remove drivers and header files for EOF of elx driver as
	# per PSARC/2003/770
	#
	rm -f $root/platform/i86pc/kernel/drv/elx
	rm -f $root/platform/i86pc/kernel/drv/elx.conf
	rm -f $usr/include/sys/elx.h
	rm -f $root/boot/solaris/drivers/isa.175/elx.bef

	#
	# Remove drivers for EOF of pe driver as per PSARC/2004/051
	#
	rm -f $root/kernel/drv/pe
	rm -f $root/kernel/drv/pe.conf
	rm -f $root/boot/solaris/drivers/isa.125/pe3.bef

	#
	# Remove drivers for EOF of Compaq NCR, Compaq SMART2, AMI Mega
	# card and /usr/bin/smart2cfg as per PSARC/2003/701 and
	# PSARC/2004/207
	#
	rm -f $root/kernel/drv/cpqncr
	rm -f $root/kernel/drv/cpqncr.conf
	rm -f $root/boot/solaris/drivers/notisa.020/cpqncr.bef
	rm -f $root/platform/i86pc/kernel/drv/smartii
	rm -f $root/platform/i86pc/kernel/drv/smartii.conf
	rm -f $usr/bin/smart2cfg
	rm -f $root/kernel/drv/mega
	rm -f $root/kernel/drv/mega.conf
	rm -f $root/boot/solaris/drivers/notisa.010/mega.bef
	rm -f $root/kernel/mach/compaq
	rm -f $root/kernel/mach/corollary

	#
	# Remove eisa nexus driver and header files for EOF of EISA
	# support as per PSARC/2003/650
	#
	rm -f $root/platform/i86pc/kernel/drv/eisa
	rm -f $usr/platform/i86pc/include/sys/eisarom.h
	rm -f $usr/platform/i86pc/include/sys/nvm.h

	#
	# Remove xmem headers (they moved back to usr/include/sys/fs)
	#
	rm -f $usr/include/ia32/sys/fs/xmem.h
	rm -f $usr/include/ia32/sys/fs/seg_xmem.h
	rm -rf $usr/include/ia32/sys/fs

	#
	# Remove junk headers
	#
	rm -f $usr/platform/i86pc/include/sys/mcdma.h
	rm -f $usr/platform/i86pc/include/sys/xque.h

	#
	# Remove obsolete x86 hat layer and associated adb scripts
	#
	rm -f $root/platform/i86pc/kernel/mmu/mmu32
	rm -f $root/platform/i86pc/kernel/mmu/mmu36
	rm -rf $root/platform/i86pc/kernel/mmu
	rm -f $usr/lib/adb/hwpp
	rm -f $usr/lib/adb/hatppp
	rm -f $usr/lib/adb/hat.nxt
	rm -f $usr/lib/adb/hwpp.nxt
	
	#
	# Remove drivers for EOF of chs as per PSARC/2005/581
	#
	rm -f $root/kernel/drv/chs
	rm -f $root/kernel/drv/chs.conf
	rm -f $root/boot/solaris/drivers/notisa.020/chs.bef

	#
	# Remove drivers & header files for EOF of dbri as per PSARC 2005/582
	#
	rm -f $root/kernel/drv/sparcv9/dbri
	rm -f $root/usr/include/sys/dbriio.h
	rm -f $root/usr/include/sys/mmcodecreg.h

	#
	# Remove drivers for EOF of pcscsi as per PSARC/2005/003
	#
	rm -f $root/kernel/drv/pcscsi
	rm -f $root/kernel/drv/pcscsi.conf
	rm -f $root/boot/solaris/drivers/notisa.010/pcscsi.bef
	
	#
	# Remove drivers for EOF of dpt as per PSARC/2003/701
	#
	rm -f $root/boot/solaris/drivers/isa.125/dpt.bef
	rm -f $root/platform/i86pc/kernel/drv/dpt
	rm -f $root/platform/i86pc/kernel/drv/dpt.conf
	rm -rf $usr/include/sys/dktp/dpt

	#
	# Remove drivers for EOF of mlx driver as per PSARC/2003/701
	#
	rm -f $root/boot/solaris/drivers/notisa.010/mlx.bef
	rm -f $root/platform/i86pc/kernel/drv/mlx
	rm -f $root/platform/i86pc/kernel/drv/mlx.conf
	rm -rf $usr/include/sys/dktp/mlx

	#
	# Remove snlb
	#
	rm -f $root/kernel/misc/snlb
	rm -f $root/kernel/misc/amd64/snlb
	rm -f $root/usr/include/sys/dktp/dklb.h
	rm -f $root/usr/include/sys/dktp/snlb.h

	#
	# Remove objmgr
	#
	rm -f $root/kernel/drv/objmgr.conf
	rm -f $root/kernel/drv/objmgr
	rm -f $root/kernel/drv/amd64/objmgr
	rm -f $root/usr/include/sys/dktp/objmgr.h

	#
	# Remove other unused headers
	#
	rm -f $root/usr/include/sys/scsi/impl/pkt_wrapper.h
	rm -f $root/usr/include/sys/dktp/hba.h
	rm -f $root/usr/include/sys/dktp/cdtypes.h
	rm -f $root/usr/include/sys/dktp/scdk.h
	rm -f $root/usr/include/sys/dktp/scdkwatch.h
	rm -f $root/usr/include/sys/dktp/sctarget.h
	rm -f $root/usr/include/sys/dktp/tgcd.h
	rm -f $root/usr/include/sys/dktp/tgpassthru.h
 
	#
	# Remove Floating Point Emulator for EOF as per PSARC/2003/651
	#
	rm -f $root/platform/i86pc/kernel/misc/emul_80387

	#
	# Remove 64-bit adp, cadp and cpqhpc
	#
	rm -f $root/kernel/drv/amd64/adp
	rm -f $root/kernel/drv/amd64/cadp
	rm -f $root/kernel/drv/amd64/cpqhpc

	#
	# Remove 64-bit i2o_bs, i2o_msg, i2o_scsi, pci_to_i2o, mscsi, ncrs,
	# msm, spwr, bscv, bscbus
	#
	rm -f $root/kernel/drv/amd64/i2o_bs
	rm -f $root/kernel/misc/amd64/i2o_msg
	rm -f $root/kernel/drv/amd64/i2o_scsi
	rm -f $root/kernel/drv/amd64/pci_to_i2o
	rm -f $root/platform/i86pc/kernel/drv/amd64/mscsi
	rm -f $root/kernel/drv/amd64/ncrs
	rm -f $root/platform/i86pc/kernel/drv/amd64/msm
	rm -f $root/kernel/drv/amd64/spwr
	rm -f $root/platform/i86pc/kernel/drv/amd64/bscv
	rm -f $root/platform/i86pc/kernel/drv/amd64/bscbus

	# Remove obsolete pfil modules, binaries, and configuration files
	rm -f $root/kernel/drv/pfil
	rm -f $root/kernel/drv/pfil.conf
	rm -f $root/kernel/drv/sparcv9/pfil
	rm -f $root/kernel/drv/amd64/pfil
	rm -f $root/kernel/strmod/pfil
	rm -f $root/kernel/strmod/sparcv9/pfil
	rm -f $root/kernel/strmod/amd64/pfil
	rm -f $root/usr/sbin/pfild

	# Remove obsolete atomic_prim.h file.
	rm -f $usr/include/v9/sys/atomic_prim.h

	#
	# Remove sc_nct binary and the corresponding symlink to sc_nct from the
	# Montecarlo platform specific directories (Reference: PSARC 2003/606). 
	# To be specific, the following binary will be removed.
	# /platform/SUNW,UltraSPARC-IIe-NetraCT-40/kernel/drv/sparcv9/sc_nct 
	# Also, the following symlink will be removed.
	# /platform/SUNW,UltraSPARC-IIe-NetraCT-60/kernel/drv/sparcv9/sc_nct
	#
	if [ -f $root/platform/SUNW,UltraSPARC-IIe-NetraCT-40/kernel/drv/sparcv9/sc_nct ]; then
		rm -f $root/platform/SUNW,UltraSPARC-IIe-NetraCT-40/kernel/drv/sparcv9/sc_nct
		rm -f $root/platform/SUNW,UltraSPARC-IIe-NetraCT-60/kernel/drv/sparcv9/sc_nct
	fi

	#
	# In case of bfu to an older release, remove traces of "new"
	# Kerberos mechanisms.  Kerberos libraries and paths are corrected
	# after extraction is complete.
	#
	rm -f $root/kernel/misc/kgss/kmech_krb5
	rm -f $root/kernel/misc/kgss/sparcv9/kmech_krb5
	rm -f $root/platform/$karch/kernel/misc/kgss/sparcv9/kmech_krb5
	#
	# Diskless clients have already extracted /usr so don't delete these
	# Non-global zones never extracts /usr so don't delete these
	#
	if [ $diskless = no -a $zone = global ]; then
		rm -f $usr/lib/gss/mech_krb5.so
		rm -f $usr/lib/gss/mech_krb5.so.1
		rm -f $usr/lib/sparcv9/gss/mech_krb5.so
		rm -f $usr/lib/sparcv9/gss/mech_krb5.so.1
	fi

	# Remove old OpenSSL stuff from SUNWwbint
	rm -rf $usr/include/openssl
	rm -rf $usr/lib/openssl

	#Remove ufs logging module - now merged into ufs module
	rm -f $rootprefix/kernel/misc/ufs_log
	rm -f $rootprefix/kernel/misc/sparcv9/ufs_log

	#Remove ufs_log mdb/kmdb modules - now merged in to ufs module
	rm -f $rootprefix/kernel/kmdb/ufs_log
	rm -f $rootprefix/kernel/kmdb/sparcv9/ufs_log
	rm -f $rootprefix/kernel/kmdb/amd64/ufs_log
	rm -f $rootprefix/usr/lib/mdb/kvm/ufs_log.so
	rm -f $rootprefix/usr/lib/mdb/kvm/sparcv9/ufs_log.so
	rm -f $rootprefix/usr/lib/mdb/kvm/amd64/ufs_log.so

	#Remove diskmgtd. If backward BFU, will get re-installed from
	#archive.
	rm -f $usr/lib/diskmgtd

	#
	# Remove old ia64 cruft
	#
	if [ $target_isa = i386 ]; then
		rm -f $usr/include/sys/ia64_archext.h
		rm -f $usr/include/sys/sysia64.h
		rm -rf $usr/include/ia64
	fi

	#
	# Remove machpage-related stuff
	#
	rm -f $usr/platform/*/include/vm/mach_page.h
	rm -f $usr/lib/adb/machpp

	#
	# Remove old cacheos
	#
	rm -f $root/etc/init.d/cacheos
	rm -f $root/etc/init.d/cacheos.finish
	rm -f $root/etc/init.d/cachefs.root
	rm -f $root/etc/rcS.d/S35cacheos.sh
	rm -f $root/etc/rc2.d/S93cacheos.finish
	rm -f $root/etc/rcS.d/S41cachefs.root

	#
	# Remove unneeded nfsmapid entries
	#
	nfsmapid_cfg

	#
	# Nuke the nfsauth headers when we're working with the 'global'
	# or a fully populated nonglobal zone. The cpio archive will lay the
	# right one to match mountd(1m)'s comm method w/the kernel (via
	# kRPC or Doors/XDR).
	#
	dir_is_inherited usr 2>/dev/null;
	if [ $? = 1 -o $zone = global ]; then
		rm -f ${rootprefix}/usr/include/rpcsvc/nfsauth_prot.x
		rm -f ${rootprefix}/usr/include/rpcsvc/nfsauth_prot.h
		rm -f ${rootprefix}/usr/include/nfs/auth.h
	fi

	#
	# Move the original manifests aside; later we will restore
	# unchanged originals to avoid superfluous re-import on reboot.
	# (First blow away the old dir path just to be safe.)
	#
	rm -rf $root/$old_mfst_dir
	[ -d $root/$new_mfst_dir ] && mv $root/$new_mfst_dir $root/$old_mfst_dir

	#
	# Remove obsolete sum.h
	#
	rm -f $usr/include/sum.h

	#
	# Remove obsolete std.h
	#
	rm -f $usr/include/std.h

	#
	# Remove obsolete rpc/trace.h
	#
	rm -f $usr/include/rpc/trace.h

	#
	# Remove acpi_intp module
	#
	if [ $target_isa = i386 ]; then
		rm -f $root/kernel/misc/acpi_intp
		rm -f $root/kernel/misc/amd64/acpi_intp
	fi

	#
	# Remove obsolete librac
	#
	rm -f $usr/include/rpc/rac.h
	rm -f $usr/lib/llib-lrac
	rm -f $usr/lib/llib-lrac.ln
	rm -f $usr/lib/amd64/llib-lrac.ln
	rm -f $usr/lib/sparcv9/llib-lrac.ln
	rm -f $usr/lib/librac.so
	rm -f $usr/lib/librac.so.1
	rm -f $usr/lib/amd64/librac.so
	rm -f $usr/lib/amd64/librac.so.1
	rm -f $usr/lib/sparcv9/librac.so
	rm -f $usr/lib/sparcv9/librac.so.1

	#
	# Remove /kernel/mac.  This directory was introduced by
	# PSARC/2006/248, and along with this came a syntax change to the
	# /etc/aggregation.conf file.  After archives have been extracted,
	# we check for the existance of the /kernel/mac directory to see if
	# we're doing a backward bfu and need to convert the syntax of the
	# /etc/aggregation.conf file to its old format.
	#
	if [ -d $root/kernel/mac ]; then
		from_new_aggrconf=1
		rm -rf $root/kernel/mac
	else
		from_new_aggrconf=0
	fi

	# Remove libcmd from $root/lib.  It has moved back to $usr/lib.
	rm -f $root/lib/libcmd.so
	rm -f $root/lib/libcmd.so.1
	rm -f $root/lib/amd64/libcmd.so
	rm -f $root/lib/amd64/libcmd.so.1
	rm -f $root/lib/sparcv9/libcmd.so
	rm -f $root/lib/sparcv9/libcmd.so.1
	rm -f $root/lib/llib-lcmd
	rm -f $root/lib/llib-lcmd.ln
	rm -f $root/lib/amd64/llib-lcmd.ln
	rm -f $root/lib/sparcv9/llib-lcmd.ln

	# Remove audit_record_attr. Moved to /usr/lib/security
	rm -f $root/etc/security/audit_record_attr

	#
	# Remove xmemfs altogether.
	#
	rm -f $usr/include/sys/fs/xmem.h
	rm -f $usr/include/sys/fs/seg_xmem.h
	rm -f $usr/kernel/fs/xmemfs
	rm -f $usr/kernel/fs/amd64/xmemfs
	rm -rf $usr/lib/fs/xmemfs

	#
	# Remove obsolete libmacadm, liblaadm and libwladm. If this is
	# a backwards BFU, they will be extracted by cpio.
	#
	rm -f $root/lib/libmacadm.so.1
	rm -f $root/lib/liblaadm.so.1
	rm -f $root/lib/libwladm.so.1

	#
	# Remove PCI hotplug devlinks.  Their format has changed,
	# and the old devlinks will interfere with the new ones.
	#
	rm -f $root/dev/cfg/*pci*

	#
	# remove the architecture-specific sn1_brand module since it's being
	# replaced with platform-specific modules.
	#
	rm -f $root/kernel/brand/sparcv9/sn1_brand

	#
	# Remove I2O.
	#
	rm -f $root/kernel/drv/i2o_bs
	rm -f $root/kernel/drv/i2o_bs.conf
	rm -f $root/kernel/drv/i2o_scsi
	rm -f $root/kernel/drv/i2o_scsi.conf
	rm -f $root/kernel/drv/pci_to_i2o
	rm -f $root/kernel/drv/pci_to_i2o.conf
	rm -f $root/kernel/misc/i2o_msg
	rm -f $root/usr/include/sys/i2o/*
	rmdir $root/usr/include/sys/i2o/ 2>/dev/null

	#
	# Remove /usr/ccs/bin dependency files that now live in
	# /usr/share/lib/ccs
	#
	rm -f $usr/ccs/bin/gprof.callg.blurb
	rm -f $usr/ccs/bin/gprof.flat.blurb
	rm -f $usr/ccs/bin/nceucform
	rm -f $usr/ccs/bin/ncform
	rm -f $usr/ccs/bin/nrform
	rm -f $usr/ccs/bin/yaccpar

	#
	# Remove us driver header.
	#
	rm -f $usr/platform/sun4u/include/sys/us_drv.h

	# End of pre-archive extraction hacks.

	if [ $diskless = no -a $zone = global ]; then
		print "Extracting ufs modules for boot block ... \c" | \
			tee -a $EXTRACT_LOG
		do_extraction $cpiodir/$karch.usr$ZFIX \
			'usr/platform/'$karch'/lib/fs/ufs/*' | \
			tee -a $EXTRACT_LOG
		case $target_isa in
		    sparc)
			if [[ "$rootslice" = /dev/rdsk/* ]]; then
				print "Installing boot block on $rootslice."
				cd $usr/platform/$karch/lib/fs/ufs
				installboot ./bootblk $rootslice
			fi
			;;
		    i386)
			;;
		    *)
			;;	# unknown ISA
		esac
	fi

	if [ $diskless = yes ]; then
		node=${root##*/}
		archlist=""
		for arch in $allarchs
		do
			egrep -s '/export/exec/.*'$arch'/usr/kvm' \
				$root/etc/vfstab ||
				test -d $root/platform/$arch &&
				archlist="$archlist $arch"
		done
		if [ -z "$old_style_archives" ]; then
			extract_archives lib generic
			extract_archives sbin generic
			extract_archives kernel generic
		fi
		extract_archives root generic $archlist
		if [ $target_isa = i386 ]; then
			extract_boot_archives boot $archlist
		fi
	else
		export PATH=/tmp/bfubin
		node=`uname -n`
		if [ $zone = global ]; then
			extract_archives usr generic $usrarchs
			if [ -z "$old_style_archives" ]; then
				extract_archives lib generic
				extract_archives sbin generic
				extract_archives kernel generic
			fi
			extract_archives root generic $rootarchs
			if [ $target_isa = i386 ]; then
		        	#
		        	#  The assumption here is that if boot
				#  archives exist at all, they only exist
				#  for architectures where we also have
				#  .root archives.
				#
				extract_boot_archives boot $rootarchs
			fi
		else
			dir_is_inherited usr ||
			    extract_archives usr generic $usrarchs
			dir_is_inherited lib ||
			    extract_archives lib generic
			dir_is_inherited sbin ||
			    extract_archives sbin generic
			dir_is_inherited platform &&
			    extract_archives root generic ||
			    extract_archives root generic $rootarchs
		fi
	fi

	touch reconfigure

	#
	# UltraSparc III platforms have aes module in platform directory
	#
	if [ ! -f $root/platform/$plat/kernel/crypto/sparcv9/aes ]; then
		rm -f $root/platform/sun4u-us3/kernel/crypto/sparcv9/aes
		rm -f $root/platform/sun4u-us3/kernel/crypto/sparcv9/aes256
	fi

	if [ $zone = global ]; then
		print "\nRemoving duplicate kernel binaries ..."
		#
		# First, find all regular files underneath the */kernel
		# directories we extracted, and mark them as older or newer
		# than our reference file -- if newer, they were extracted
		# during the bfu.
		#
		# We then split out the pre-/kernel part from the post-/kernel
		# part, sort by post-/kernel part and age (new first), and
		# delete old files which have new counterparts.
		#
		dirs="$rootprefix/kernel $usr/kernel"
		for plat in $archlist $rootarchs $usrarchs; do
			dir=$rootprefix/platform/$plat/kernel
			[[ -d $dir ]] && dirs="$dirs $dir"
		done

		age=new
		ls -ct $time_ref `find $dirs -type f 2>/dev/null` | uniq |
		    while read f; do
			if [[ $f = $time_ref ]] then
				age=old
			else
				echo $age $f
			fi
		done |
		    sed 's@\(.*/kernel\)/@\1 @' | sort -k 3 -k 1 | nawk '
			/^new/ { lastname = $3 }
			/^old/ { if (lastname == $3) { print $2 "/" $3 } }
		    ' | while read x; do
			echo "rm $x"
			rm $x
		done
	fi

	echo
	# Simulate installation of SUNWcry* - these are in the bfu archives.
	if [ -f $rootprefix/etc/crypto/kcf.conf -a \
	    -f $rootprefix/etc/crypto/pkcs11.conf ]; then
		enable_crypto_unlimited
	fi

	# Add uCF's metaslot feature
	if [ -f $rootprefix/etc/crypto/pkcs11.conf ] ; then
		enable_crypto_metaslot
	fi

	# Cleanup old Kerberos mechanisms
	cleanup_kerberos_mechanisms

	# Cleanup old RBAC profiles
	rbac_cleanup

	# Fix network datalink configuration
	if [ $zone = global -a $need_datalink = yes ]; then
		create_datalink_conf
	fi

	print "\nRestoring configuration files.\n"

	cd $root
	rm -rf bfu.ancestor
	test -d bfu.parent && mv bfu.parent bfu.ancestor
	mkdir bfu.parent
	print "Restoring configuration files ... \c" >> $EXTRACT_LOG
	filelist $zone | cpio -pdmu bfu.parent 2>>$EXTRACT_LOG || \
	    extraction_error "restoring configuration files"
	if [ $multi_or_direct = no ]; then
		if [ $have_realmode = yes ]; then
			if [ -d bfu.realmode ]; then
				( cd bfu.realmode ; realmode_filelist | \
				    cpio -pdmu ../bfu.ancestor 2>/dev/null )
				rm -rf bfu.realmode
			fi
			mkdir bfu.realmode
			( cd bfu.parent ; realmode_filelist | \
				cpio -pdmu ../bfu.realmode 2>/dev/null )
		else
			for file in $realmode_files
			do
				rm -rf bfu.parent/$file
			done
		fi
	fi

	cd bfu.child
	for file in `filelist $zone`
	do
		# parent: freshly-BFUed version
		# child: pre-BFU version
		# ancestor: installed from archives the last time you BFUed
		# actual: in the root filesystem at this moment (same as parent)

		parent=$rootprefix/bfu.parent/$file
		child=$rootprefix/bfu.child/$file
		ancestor=$rootprefix/bfu.ancestor/$file
		conflicts=$rootprefix/bfu.conflicts/$file
		actual=$rootprefix/$file

		# if a superfluous-to-local-zones file was blown away, skip it
		[ -f $actual ] || continue

		# if there's been no change by the BFU, skip it
		cmp -s $child $actual && continue

		# if the file was not installed by the BFU, skip it
		[  -f $parent ] || continue

		# if this is a file which should never be updated by BFU,
		# preserve the original (child) version
		if (echo $preserve_files | grep $file >/dev/null 2>&1)
		then
			print "    preserve: $file"
			cp -p $child $actual
			continue
		fi

		# if the file was accepted from the parent on the last BFU,
		# then accept it again this time without argument.  Or, if
		# this is the first bfu after an standard Solaris install
		# or upgrade, compare the file to one installed from packages.
		# If it hasn't been modified since installation, accept
		# the file from the parent.
		if [ -f $ancestor ] ; then
			if cmp -s $child $ancestor; then
				print "      update: $file"
				continue
			fi
		elif [ "$firstbfu" = "yes" ] ; then
			installedsum=$(grep "^/$file " \
			    $rootprefix/var/sadm/install/contents |
			    awk '{ print $8 }')
			if [ -n "$installedsum" ] ; then
				actualsum=`sum $child | sed 's/ .*//'`
				if [ "$installedsum" -eq "$actualsum" ] ; then
					print "      update: $file"
					continue
				fi
			fi
		fi

		# if the BFU'ed file is the same as the beginning of the
		# pre-BFUed file, assume the user has added lines to the
		# end, and restore the pre-BFUed version
		if (cmp $child $parent 2>&1) | egrep -s 'EOF on '$parent; then
			print "     restore: $file"
			cp -p $child $actual
			continue
		fi

		# if the new version is the same as it was the last time
		# BFU was run, but still different than the pre-BFU version,
		# this is an "old" conflict; otherwise, it's a "NEW"
		# conflict.  Old conflicts can usually be safely ignored.
		if cmp -s $parent $ancestor; then
			print "old \c"
		else
			print "NEW \c"
			print $file >>$rootprefix/bfu.conflicts/NEW
		fi
		print "conflict: $file"
		(cd $root; print $file | cpio -pdmu bfu.conflicts 2>/dev/null)

		# for all conflicts, restore the pre-BFU version and let
		# the user decide what to do.
		cp -p $child $actual
	done

	if [ $zone = global ]; then
		#
		# correct permissions using /etc/minor_perm from the parent and
		# child, prefer parent.
		#
		mperm=$rootprefix/etc/minor_perm
		pmperm=$rootprefix/bfu.parent/etc/minor_perm
		if [ -f $pmperm ]
		then
			mperm="$pmperm $mperm"
		fi

		#
		# Devices with changed permissions should be added here much
		# like in i.minorperm.  The "ssm" devices are special in that
		# they have no /dev links associated with them.
		#
		while read minor dev
		do (
			set -- `fgrep -h "$minor" $mperm` "";
			if [ ! -z "$2" ]
			then
				chmod $2 $rootprefix/dev/$dev 2>/dev/null
				chown $3:$4 $rootprefix/dev/$dev 2>/dev/null
			fi
		) done <<-EOF
			ssm:*			../devices/ssm*:*
			cpc:shared		../devices/pseudo/cpc*
			icmp:icmp		icmp
			icmp6:icmp6		icmp6
			ip:ip			ip
			ip6:ip6			ip6
			rts:rts			rts
			keysock:keysock		keysock
			ipsecah:ipsecah		ipsecah
			ipsecesp:ipsecesp	ipsecesp
			spdsock:spdsock		spdsock
			sad:admin		sad/admin
			fssnap:ctl		fssnapctl
			fssnap:*		fssnap/*
			clone:ce		ce
			clone:eri		eri
			clone:ge		ge
			clone:hme		hme
			clone:le		le
			clone:qfe		qfe
			clone:bge		bge
			bge:*			bge*
			clone:dmfe		dmfe
			dmfe:*			dmfe*
			clone:pcelx		pcelx
			pcelx:*			pcelx*
			clone:dnet		dnet
			dnet:*			dnet*
			clone:elxl		elxl
			elxl:*			elxl*
			clone:iprb		iprb
			iprb:*			iprb*
			clone:spwr		spwr
			spwr:*			spwr*
		EOF

		if [ $target_isa = i386 ] && [[ $rootslice = /dev/rdsk/* || \
		    $rootslice = /dev/md/rdsk/* ]]; then
			check_boot_env
		fi

		# Check for damage due to CR 6379341.  This was actually fixed
		# back in snv_24, but users BFUing from an S10 build up to
		# Nevada can still encounter it.
		rzi=$root/etc/zones/index
		if [ -f $rzi ]; then
			# Look for duplicated UUIDs.  If there are any, then
			# just wipe them out.
			if nawk -F: '
				/^\#/ || NF != 4 { print $0; next; }
				{
					if (flags[$4])
						sub(/:[-0-9a-z]*$/,":");
					print $0;
					flags[$4]=1;
				}
			' < $rzi > ${rzi}.bfu.$$; then
				if cmp -s $rzi ${rzi}.bfu.$$; then
					rm -f ${rzi}.bfu.$$
				else
					chown root:sys ${rzi}.bfu.$$
					chmod 644 ${rzi}.bfu.$$
					mv ${rzi}.bfu.$$ $rzi
				fi
			else
				rm -f ${rzi}.bfu.$$
			fi
		fi

		# Move existing /etc/aggregation.conf entries to
		# /etc/dladm/aggregation.conf; or, if bfu'ing
		# backwards, move aggregation.conf back to /etc
		aggr_old=$rootprefix/etc/aggregation.conf
		aggr_new=$rootprefix/etc/dladm/aggregation.conf
		if [ $new_dladm = yes ]; then
			if [ -f $aggr_old ]; then
				# use cat instead of cp/mv to keep
				# owner+group of dest
				cat $aggr_old > $aggr_new
				rm -f $aggr_old
			fi
		else
			if [ -f $aggr_new ]; then
				cp $aggr_new $aggr_old
				chgrp sys $aggr_old
				rm -rf $rootprefix/etc/dladm
			fi
		fi
	fi

	# Fix up audit permissions
	fix_up_audit

	print "\nFor each file in conflict, your version has been restored."
	print "The new versions are under $rootprefix/bfu.conflicts."
	print "\nMAKE SURE YOU RESOLVE ALL CONFLICTS BEFORE REBOOTING.\n"
	if [ $multi_or_direct = yes ]; then
		print "To install resolved changes required for reboot in the boot"
		print "archive, invoke 'bootadm update-archive${cr_args}'\n"
	fi

	if [ $zone != global ]; then
		print "Resolve conflicts in the global zone first.  Many of"
		print "the conflicts in non-global zones can be resolved by"
		print "copying the corresponding file from the global zone.\n"
	else
		fixup_mpxio

		#
		# If we're bfuing backward across PSARC/2006/248, then
		# revert the /etc/aggregation.conf to its old format.
		#
		if [ -f $rootprefix/etc/aggregation.conf -a \
		    ! -d $rootprefix/kernel/mac -a \
		    $from_new_aggrconf = 1 ]; then
			revert_aggregation_conf
		fi
	fi

	cd $root

	smf_apply_conf

	update_policy_conf

	if [ $target_isa = i386 ]; then
	    update_mptconf_i386
	fi

	if [ $zone != global ]; then
		rm -rf $global_zone_only_files $superfluous_nonglobal_zone_files
	fi

	print "bfu'ed from $cpiodir on `date +%Y-%m-%d`" >>etc/motd
	tail +`nawk '/bfu.ed from/ { x=NR }; END { print x+1 }' \
		etc/motd.old` etc/motd.old >> etc/motd

	#
	# Hacks to work around minor annoyances and make life more pleasant.
	# Part 2 of 2: post-archive-extraction stuff
	#

	rm -f var/statmon/state		# to prevent lockd/statd hangs
	for f in etc/auto_*		# to make autofs happy
	do
		file $f | grep executable >/dev/null || chmod -x $f
	done

	epilogue=$rootprefix/bfu.epilogue
	if [ -f $epilogue ]; then
		print "Executing $epilogue"
		$epilogue || print "WARNING: $epilogue failed with code $?"
	fi

	((seconds = SECONDS))
	((min = seconds / 60))
	((sec = seconds % 60))

	if [ $zone = global ]; then
		target=$node
	else
		target=$zone
	fi
	printf "Upgrade of $target took ${min}:%02d.\n" $sec

	#
	# Do logging in the background so that if the automounter is gone,
	# bfu doesn't wedge at this point.
	#
	log=$GATE/public/bfu.log
	(test -w $log && printf \
		"`date +%Y'%'m%d` $node `uname -rv` $karch $cpiodir ${min}:%02d\n" \
		$sec >>$log) &
}

#
# make sure the time reference is older than anything extracted
#
test $time_ref_seconds -eq $SECONDS && sleep 1

test $diskless = yes && extract_archives usr generic $allarchs

for root in $rootlist
do
	mondo_loop $root global
	lastroot=$root
done

if [ -s "$bfu_zone_list" ]; then
	cat "$bfu_zone_list" | while read zone zonepath; do
		print "\nNow for zone $zone..."
		mondo_loop $zonepath/root $zone
	done

	#
	# Normally we would clean up $bfu_zone_list but instead we leave it
	# behind for ACR to locate and use inside the BFU alternate reality.
	#
fi

print "Turning off delayed i/o and syncing filesystems ..."
sync
fastfs -s $rootlist $usr
fastfs $rootlist $usr
sync
lockfs -f $rootlist $usr

egrep -s "^error " $EXTRACT_LOG
if [ $? -eq 0 ]; then
	print "\nWARNING: archive extraction errors occurred.\n"
	print "See $EXTRACT_LOG for details.\n"
fi

lastrootprefix=${lastroot%/}

if [ -t 0 -a -t 1 -a -t 2 ]; then
	print "\nEntering post-bfu protected environment (shell: ksh)."
	print "Edit configuration files as necessary, then reboot.\n"
	cd $lastrootprefix/bfu.conflicts
	PS1='bfu# ' ksh -ip
fi

print "Exiting post-bfu protected environment.  To reenter, type:"
print LD_NOAUXFLTR=1 LD_LIBRARY_PATH=/tmp/bfulib $ldlib64 PATH=/tmp/bfubin \
    /tmp/bfubin/ksh

exit 0