#! /bin/sh # PCP QA Test No. 068 # pmNewContext() bad error status if pmcd is not running # # Note: this is the simplest test to get the pmcd start/stop filtering # to be correct ... use this to tune _filter_pcp_start() and # _filter_pcp_stop() in common.filter # # Copyright (c) 1995-2002 Silicon Graphics, Inc. All Rights Reserved. # seq=`basename $0` echo "QA output created by $seq" . ./common.product . ./common.check . ./common.filter _needclean=true LOCALHOST=`hostname` trap "_cleanup" 0 1 2 3 15 if [ -d $PCP_LOG_DIR/pmlogger ] then LOGGING_DIR=$PCP_LOG_DIR/pmlogger else LOGGING_DIR=$PCP_LOG_DIR fi _cleanup() { echo >>$seq.full echo "--- cleanup ---" >>$seq.full if [ $_needclean ] then pmafm $LOGGING_DIR/$LOCALHOST/Latest remove >$tmp.cmd 2>&1 \ && $sudo sh $tmp.cmd echo >>$seq.full echo "--- pcp start ---" >>$seq.full $sudo $PCP_RC_DIR/pcp restart | tee -a $seq.full | _filter_pcp_start echo >>$seq.full echo "--- _wait_for_pmcd ---" >>$seq.full _wait_for_pmcd | tee -a $seq.full echo >>$seq.full echo "--- _wait_for_pmlogger ---" >>$seq.full _wait_for_pmlogger | tee -a $seq.full fi rm -f $tmp.* exit 0 } rm -f $seq.full # real QA test starts here echo "--- pcp stop ---" >>$seq.full $sudo $PCP_RC_DIR/pcp stop | tee -a $seq.full | _filter_pcp_stop echo >>$seq.full echo "--- run pmcdgone ---" >>$seq.full $sudo src/pmcdgone | tee -a $seq.full