QA output created by 1006 === views/006-01 === #kmchart version 1 chart title "QA Units compatible - time" style plot plot metric sample.seconds plot metric sample.milliseconds exit=0 --- out --- --- err --- : Console available : Global settings setup complete : Metric group setup complete (0 hosts, 0 archives) : Timezones and time window setup complete : Time button resources loaded : Phase1 user interface constructors complete : PmChart::setActiveTab index=0 r=1 : Phase2 user interface setup complete : Chart::ctor complete() : Chart::setCurrent() true : Tab::addChart: [0]->Chart : Chart::addItem src= : addItem metric=sample.seconds : addItem nitems=1 : Chart::addItem src= : addItem metric=sample.milliseconds : SamplingEngine::isCompatible type=5, units=millisec : addItem nitems=2 --- post --- === views/006-02 === #kmchart version 1 chart title "QA Units odd but OK - time(util) and none" style plot plot metric sample.seconds plot metric sample.control exit=0 --- out --- --- err --- : Console available : Global settings setup complete : Metric group setup complete (0 hosts, 0 archives) : Timezones and time window setup complete : Time button resources loaded : Phase1 user interface constructors complete : PmChart::setActiveTab index=0 r=1 : Phase2 user interface setup complete : Chart::ctor complete() : Chart::setCurrent() true : Tab::addChart: [0]->Chart : Chart::addItem src= : addItem metric=sample.seconds : addItem nitems=1 : Chart::addItem src= : addItem metric=sample.control : SamplingEngine::isCompatible type=0, units= : addItem nitems=2 --- post --- === views/006-03 === #kmchart version 1 chart title "QA Units BAD - time(->time util) and count(->count/sec)" style plot plot metric sample.seconds plot metric sample.step_counter exit=1 --- out --- --- err --- : Console available : Global settings setup complete : Metric group setup complete (0 hosts, 0 archives) : Timezones and time window setup complete : Time button resources loaded : Phase1 user interface constructors complete : PmChart::setActiveTab index=0 r=1 : Phase2 user interface setup complete : Chart::ctor complete() : Chart::setCurrent() true : Tab::addChart: [0]->Chart : Chart::addItem src= : addItem metric=sample.seconds : addItem nitems=1 : Chart::addItem src= : addItem metric=sample.step_counter : SamplingEngine::isCompatible type=0, units=count --- post --- Error: views/006-03[6] Failed to plot metric "sample.step_counter" for host : Units for this metric are not compatible with other plots in this chart === views/006-04 === #kmchart version 1 chart title "QA Units OK - inst first" style plot plot metric sample.byte_rate plot metric sample.byte_ctr chart title "QA Units OK - ctr first" style plot plot metric sample.byte_ctr plot metric sample.byte_rate chart title "QA Units OK - Kbyte/sec and byte/msec" style plot plot metric sample.mirage plot metric sample.mirage_longlong chart title "QA Units OK - count/sec and count(->count/sec)" style plot plot metric sample.write_me plot metric sample.pdu exit=0 --- out --- --- err --- : Console available : Global settings setup complete : Metric group setup complete (0 hosts, 0 archives) : Timezones and time window setup complete : Time button resources loaded : Phase1 user interface constructors complete : PmChart::setActiveTab index=0 r=1 : Phase2 user interface setup complete : Chart::ctor complete() : Chart::setCurrent() true : Tab::addChart: [0]->Chart : Chart::addItem src= : addItem metric=sample.byte_rate : addItem nitems=1 : Chart::addItem src= : addItem metric=sample.byte_ctr : SamplingEngine::isCompatible type=0, units=byte : addItem nitems=2 : Chart::ctor complete() : Tab::addChart: [0]->Chart : Chart::addItem src= : addItem metric=sample.byte_ctr : addItem nitems=1 : Chart::addItem src= : addItem metric=sample.byte_rate : SamplingEngine::isCompatible type=0, units=byte / sec : addItem nitems=2 : Chart::ctor complete() : Tab::addChart: [0]->Chart : Chart::addItem src= : addItem instance sample.mirage[m-00] : addItem nitems=1 : Chart::addItem src= : addItem instance sample.mirage_longlong[m-00] : SamplingEngine::isCompatible type=2, units=byte / millisec : addItem nitems=2 : Chart::ctor complete() : Tab::addChart: [0]->Chart : Chart::addItem src= : addItem metric=sample.write_me : addItem nitems=1 : Chart::addItem src= : addItem metric=sample.pdu : SamplingEngine::isCompatible type=3, units=count : addItem nitems=2 --- post --- === views/006-05 === #kmchart version 1 chart title "QA Units BAD - byte / msec and count/sec" style plot plot metric sample.mirage_longlong plot metric sample.write_me exit=1 --- out --- --- err --- : Console available : Global settings setup complete : Metric group setup complete (0 hosts, 0 archives) : Timezones and time window setup complete : Time button resources loaded : Phase1 user interface constructors complete : PmChart::setActiveTab index=0 r=1 : Phase2 user interface setup complete : Chart::ctor complete() : Chart::setCurrent() true : Tab::addChart: [0]->Chart : Chart::addItem src= : addItem instance sample.mirage_longlong[m-00] : addItem nitems=1 : Chart::addItem src= : addItem metric=sample.write_me : SamplingEngine::isCompatible type=0, units=count / sec --- post --- Error: views/006-05[7] Failed to plot metric "sample.write_me" for host : Units for this metric are not compatible with other plots in this chart