#pmieconf-rules 1 # --- DO NOT MODIFY THIS FILE --- see pmieconf(4) # rule filesys.filling summary = "$rule$" enumerate = hosts predicate = "some_host ( some_inst ( ( 100 * filesys.used $hosts$ / filesys.capacity $hosts$ ) > $threshold$ && filesys.used $hosts$ + $lead_time$ * ( rate filesys.used $hosts$ ) > filesys.capacity $hosts$ ) )" enabled = yes version = 1 help = "Filesystem is at least threshold percent full and the used space is growing at a rate that would see the filesystem full within lead_time."; string rule default = "File system is filling up" modify = no display = no; percent threshold default = 95 help = "The threshold of filesystem fullness expressed as a percentage, usually in the range 90 to 99."; string lead_time default = "20 min" help = "The rule is true if the filesystem would be full within this time given the recent rate of growth. Normally requires a scale such as \"sec\", \"min\" or \"hr\", otherwise the value is interpreted as meaning seconds."; string delta default = "4 mins" help = "Sample interval between evaluations of this rule. The calculation of the projected rate of growth is sensitive to variations in the observed fullness of the filesystem. Adjust this parameter to be smaller if the filesystems' fullness are very stable and you want earlier warning of impending filling. Else make the parameter larger to avoid false warnings if the filesystems are close to full in the normal state and subject to bursts of file creation and deletion."; string action_expand default = %v%used[%i]@%h display = no modify = no; string email_expand default = "host: %h filesystem: %i used: %v%" display = no modify = no; # Configuration info specific to non-PCP tools follows... # # for SGI Embedded Support Partner integration: string esp_type default = "0x20004A" display = no modify = no; # for HP OpenView integration: string ov_severity display = no default = "Critical"; # for CA/Unicenter TNG integration: string tngfw_color display = no default = "Red"; # for EnlightenDSM integration: string enln_test default = filesys.filling display = no modify = no; string enln_units default = %used[%i] display = no modify = no; unsigned enln_severity display = no default = 5; # # --- DO NOT MODIFY THIS FILE --- see pmieconf(4)