1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
|
Global Settings
===============
Sampling
[ ] Open the Settings dialog. This is available from the Edit
menu (Linux) or from the pmchart Preferences menu on a Mac.
[ ] Type some invalid chart intervals into the one-line editor
(try: abc, 0.1.1, -1 - none should be possible)
[ ] Set the chart interval to zero and press OK - should block
this with an error dialog.
[ ] Type some invalid logger intervals into the one-line editor
(try: 0XY, 1.0.2, -1 - none should be possible)
[ ] Set the logger interval to zero and press OK - should block
this with an error dialog.
[ ] Set default logger interval to 20 minutes
Change units to Milliseconds; value should be: 1,200,000
Change units to Seconds; value should be: 1,200
Change units to Minutes; value should be: 20
Change units to Hours; value should be: 0.333333
Change units to Days; value should be: 0.138888
Change units to Weeks; value should be: 0.001984
[ ] Set default chart interval to 0.25 seconds
Change units to Milliseconds; value should be: 250
Change units to Seconds; value should be: 0.25
Change units to Minutes; value should be: 0.004166
Change units to Hours; value should be: 0.000069
Change units to Days; value should be: 0.000002
Change units to Weeks; value should be: 0.000000
Change units to Seconds; reset value to 0.25 seconds
[ ] Move the sample history and visible history sliders - they
should never allow visible history to become less than the
sample history, and neither is ever allowed to become less
than 2.
[ ] Check that only numeric values can be entered into each of
the visible and simple history spin boxes - check range of
values is again 2 -> maximum (360 at the moment).
[ ] Check that the spin box Up/Down arrows increase/decrease
each value by 1, and that PageUp/PageDown increase/decrease
each value by 10 - check the range of values is again 2 ->
the maximum, for all of Up/Down/PageUp/PageDown.
[ ] Set sample history size to 4
[ ] Set visible history size to 2
[ ] Press OK, exit pmchart, restart pmchart, bring up Settings
dialog and verify the following values are set...
( ) Default Chart Interval: 0.25 seconds
( ) Default Record Interval: 1200 seconds
( ) Default Visible Points: 2
( ) Default Sample Count: 4
Colors
[ ] Open the Settings Dialog, click on the Colors tab.
[ ] Click the Selected Chart Highlight button, select a different
colour (hot pink), and click OK. Verify that the push button
changes colour to your selection.
[ ] Click the Canvas Background button, select a different colour
(white), and click OK. Verify that the push button changes
colour to your selection.
[ ] Click on one of the existing Default plot colours and select a
different colour. Verify the new colour is displayed for that
button.
[ ] Click on any three of the white (empty) color buttons and make
a colour selection for each. Any three buttons - gaps in the
set are fine, and testing extremes (next free slot, last free)
is a good idea too).
[ ] Push the OK button to accept your changes.
[ ] Open the QA View "qa/views/RotateColors", and expand the window
the full height of your screen . Also open the Settings dialog
again at the colors page, and verify that the colors have been
used for each plot in the View in the order listed on the page.
[ ] Verify also that the Settings dialog is displaying the colours
you selected before, but with no spaces between colours now -
i.e. with any unused (white) "gap" buttons removed.
[ ] Finally, verify that the plot after the final colour specified
originally in the Settings dialog has rotated back to the first
colour, the next has rotated back to the second colour, etc.
Toolbar
[ ] Open the Settings Dialog, click on the Toolbar tab.
[ ] Uncheck the "Show Toolbar on Startup" check box.
[ ] Select "Right and Vertical" from the Location/Orientation box.
[ ] Quit pmchart. Restart pmchart. Verify that the Toolbar is not
displayed at all. Verify also that the Toolbar option from the
Options menu is not checked.
[ ] Select the Toolbar item in the Options menu. Verify that the
toolbar is now displayed on the right of the main charting area
instead of across the top of the main window.
[ ] Open the Settings dialog once more, verifying that the "Show
Toolbar on Startup" option is not checked and that the Location/
Orientation combo box shows Right/Vertical.
[ ] Make a series of selections from the Actions list (items are
selected and deselected simply by clicking on them). Press the
OK button and verify that the main window is updated to display
your selected actions, instead of the defaults.
[ ] Exit pmchart. Restart pmchart. Verify that your selected set of
actions is still displayed, in preference to the defaults.
|