summaryrefslogtreecommitdiff
path: root/mibs/RMON-MIB.txt
diff options
context:
space:
mode:
Diffstat (limited to 'mibs/RMON-MIB.txt')
-rw-r--r--mibs/RMON-MIB.txt3980
1 files changed, 3980 insertions, 0 deletions
diff --git a/mibs/RMON-MIB.txt b/mibs/RMON-MIB.txt
new file mode 100644
index 0000000..983c22e
--- /dev/null
+++ b/mibs/RMON-MIB.txt
@@ -0,0 +1,3980 @@
+RMON-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY,
+ NOTIFICATION-TYPE, mib-2, Counter32,
+ Integer32, TimeTicks FROM SNMPv2-SMI
+
+ TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC
+
+ MODULE-COMPLIANCE, OBJECT-GROUP,
+ NOTIFICATION-GROUP FROM SNMPv2-CONF;
+
+-- Remote Network Monitoring MIB
+
+rmonMibModule MODULE-IDENTITY
+ LAST-UPDATED "200005110000Z" -- 11 May, 2000
+ ORGANIZATION "IETF RMON MIB Working Group"
+ CONTACT-INFO
+ "Steve Waldbusser
+ Phone: +1-650-948-6500
+ Fax: +1-650-745-0671
+ Email: waldbusser@nextbeacon.com"
+ DESCRIPTION
+ "Remote network monitoring devices, often called
+ monitors or probes, are instruments that exist for
+ the purpose of managing a network. This MIB defines
+ objects for managing remote network monitoring devices."
+
+ REVISION "200005110000Z" -- 11 May, 2000
+ DESCRIPTION
+ "Reformatted into SMIv2 format.
+
+ This version published as RFC 2819."
+
+ REVISION "199502010000Z" -- 1 Feb, 1995
+ DESCRIPTION
+ "Bug fixes, clarifications and minor changes based on
+ implementation experience, published as RFC1757 [18].
+
+ Two changes were made to object definitions:
+
+ 1) A new status bit has been defined for the
+ captureBufferPacketStatus object, indicating that the
+ packet order within the capture buffer may not be identical to
+ the packet order as received off the wire. This bit may only
+
+ be used for packets transmitted by the probe. Older NMS
+ applications can safely ignore this status bit, which might be
+ used by newer agents.
+
+ 2) The packetMatch trap has been removed. This trap was never
+ actually 'approved' and was not added to this document along
+ with the risingAlarm and fallingAlarm traps. The packetMatch
+ trap could not be throttled, which could cause disruption of
+ normal network traffic under some circumstances. An NMS should
+ configure a risingAlarm threshold on the appropriate
+ channelMatches instance if a trap is desired for a packetMatch
+ event. Note that logging of packetMatch events is still
+ supported--only trap generation for such events has been
+ removed.
+
+ In addition, several clarifications to individual object
+ definitions have been added to assist agent and NMS
+ implementors:
+
+ - global definition of 'good packets' and 'bad packets'
+
+ - more detailed text governing conceptual row creation and
+ modification
+
+ - instructions for probes relating to interface changes and
+ disruptions
+
+ - clarification of some ethernet counter definitions
+
+ - recommended formula for calculating network utilization
+
+ - clarification of channel and captureBuffer behavior for some
+ unusual conditions
+
+ - examples of proper instance naming for each table"
+
+ REVISION "199111010000Z" -- 1 Nov, 1991
+ DESCRIPTION
+ "The original version of this MIB, published as RFC1271."
+ ::= { rmonConformance 8 }
+
+ rmon OBJECT IDENTIFIER ::= { mib-2 16 }
+
+ -- textual conventions
+
+OwnerString ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "This data type is used to model an administratively
+ assigned name of the owner of a resource. Implementations
+ must accept values composed of well-formed NVT ASCII
+ sequences. In addition, implementations should accept
+ values composed of well-formed UTF-8 sequences.
+
+ It is suggested that this name contain one or more of
+ the following: IP address, management station name,
+ network manager's name, location, or phone number.
+ In some cases the agent itself will be the owner of
+ an entry. In these cases, this string shall be set
+ to a string starting with 'monitor'.
+
+ SNMP access control is articulated entirely in terms
+ of the contents of MIB views; access to a particular
+ SNMP object instance depends only upon its presence
+ or absence in a particular MIB view and never upon
+ its value or the value of related object instances.
+ Thus, objects of this type afford resolution of
+ resource contention only among cooperating
+ managers; they realize no access control function
+ with respect to uncooperative parties."
+ SYNTAX OCTET STRING (SIZE (0..127))
+
+EntryStatus ::= TEXTUAL-CONVENTION
+ STATUS current
+ DESCRIPTION
+ "The status of a table entry.
+
+ Setting this object to the value invalid(4) has the
+ effect of invalidating the corresponding entry.
+ That is, it effectively disassociates the mapping
+ identified with said entry.
+ It is an implementation-specific matter as to whether
+ the agent removes an invalidated entry from the table.
+ Accordingly, management stations must be prepared to
+ receive tabular information from agents that corresponds
+ to entries currently not in use. Proper
+ interpretation of such entries requires examination
+ of the relevant EntryStatus object.
+
+ An existing instance of this object cannot be set to
+ createRequest(2). This object may only be set to
+ createRequest(2) when this instance is created. When
+ this object is created, the agent may wish to create
+ supplemental object instances with default values
+ to complete a conceptual row in this table. Because the
+
+ creation of these default objects is entirely at the option
+ of the agent, the manager must not assume that any will be
+ created, but may make use of any that are created.
+ Immediately after completing the create operation, the agent
+ must set this object to underCreation(3).
+
+ When in the underCreation(3) state, an entry is allowed to
+ exist in a possibly incomplete, possibly inconsistent state,
+ usually to allow it to be modified in multiple PDUs. When in
+ this state, an entry is not fully active.
+ Entries shall exist in the underCreation(3) state until
+ the management station is finished configuring the entry
+ and sets this object to valid(1) or aborts, setting this
+ object to invalid(4). If the agent determines that an
+ entry has been in the underCreation(3) state for an
+ abnormally long time, it may decide that the management
+ station has crashed. If the agent makes this decision,
+ it may set this object to invalid(4) to reclaim the
+ entry. A prudent agent will understand that the
+ management station may need to wait for human input
+ and will allow for that possibility in its
+ determination of this abnormally long period.
+
+ An entry in the valid(1) state is fully configured and
+ consistent and fully represents the configuration or
+ operation such a row is intended to represent. For
+ example, it could be a statistical function that is
+ configured and active, or a filter that is available
+ in the list of filters processed by the packet capture
+ process.
+
+ A manager is restricted to changing the state of an entry in
+ the following ways:
+
+ To: valid createRequest underCreation invalid
+ From:
+ valid OK NO OK OK
+ createRequest N/A N/A N/A N/A
+ underCreation OK NO OK OK
+ invalid NO NO NO OK
+ nonExistent NO OK NO OK
+
+ In the table above, it is not applicable to move the state
+ from the createRequest state to any other state because the
+ manager will never find the variable in that state. The
+ nonExistent state is not a value of the enumeration, rather
+ it means that the entryStatus variable does not exist at all.
+
+ An agent may allow an entryStatus variable to change state in
+ additional ways, so long as the semantics of the states are
+ followed. This allowance is made to ease the implementation of
+ the agent and is made despite the fact that managers should
+ never exercise these additional state transitions."
+ SYNTAX INTEGER {
+ valid(1),
+ createRequest(2),
+ underCreation(3),
+ invalid(4)
+ }
+
+ statistics OBJECT IDENTIFIER ::= { rmon 1 }
+ history OBJECT IDENTIFIER ::= { rmon 2 }
+ alarm OBJECT IDENTIFIER ::= { rmon 3 }
+ hosts OBJECT IDENTIFIER ::= { rmon 4 }
+ hostTopN OBJECT IDENTIFIER ::= { rmon 5 }
+ matrix OBJECT IDENTIFIER ::= { rmon 6 }
+ filter OBJECT IDENTIFIER ::= { rmon 7 }
+ capture OBJECT IDENTIFIER ::= { rmon 8 }
+ event OBJECT IDENTIFIER ::= { rmon 9 }
+ rmonConformance OBJECT IDENTIFIER ::= { rmon 20 }
+
+-- The Ethernet Statistics Group
+--
+-- Implementation of the Ethernet Statistics group is optional.
+-- Consult the MODULE-COMPLIANCE macro for the authoritative
+-- conformance information for this MIB.
+--
+-- The ethernet statistics group contains statistics measured by the
+-- probe for each monitored interface on this device. These
+-- statistics take the form of free running counters that start from
+-- zero when a valid entry is created.
+--
+-- This group currently has statistics defined only for
+-- Ethernet interfaces. Each etherStatsEntry contains statistics
+-- for one Ethernet interface. The probe must create one
+-- etherStats entry for each monitored Ethernet interface
+-- on the device.
+
+etherStatsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EtherStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of Ethernet statistics entries."
+ ::= { statistics 1 }
+
+etherStatsEntry OBJECT-TYPE
+ SYNTAX EtherStatsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of statistics kept for a particular
+ Ethernet interface. As an example, an instance of the
+ etherStatsPkts object might be named etherStatsPkts.1"
+ INDEX { etherStatsIndex }
+ ::= { etherStatsTable 1 }
+
+EtherStatsEntry ::= SEQUENCE {
+ etherStatsIndex Integer32,
+ etherStatsDataSource OBJECT IDENTIFIER,
+ etherStatsDropEvents Counter32,
+ etherStatsOctets Counter32,
+ etherStatsPkts Counter32,
+ etherStatsBroadcastPkts Counter32,
+ etherStatsMulticastPkts Counter32,
+ etherStatsCRCAlignErrors Counter32,
+ etherStatsUndersizePkts Counter32,
+ etherStatsOversizePkts Counter32,
+ etherStatsFragments Counter32,
+ etherStatsJabbers Counter32,
+ etherStatsCollisions Counter32,
+ etherStatsPkts64Octets Counter32,
+ etherStatsPkts65to127Octets Counter32,
+ etherStatsPkts128to255Octets Counter32,
+ etherStatsPkts256to511Octets Counter32,
+ etherStatsPkts512to1023Octets Counter32,
+ etherStatsPkts1024to1518Octets Counter32,
+ etherStatsOwner OwnerString,
+ etherStatsStatus EntryStatus
+}
+
+etherStatsIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of this object uniquely identifies this
+ etherStats entry."
+ ::= { etherStatsEntry 1 }
+
+etherStatsDataSource OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object identifies the source of the data that
+ this etherStats entry is configured to analyze. This
+ source can be any ethernet interface on this device.
+ In order to identify a particular interface, this object
+ shall identify the instance of the ifIndex object,
+ defined in RFC 2233 [17], for the desired interface.
+ For example, if an entry were to receive data from
+ interface #1, this object would be set to ifIndex.1.
+
+ The statistics in this group reflect all packets
+ on the local network segment attached to the identified
+ interface.
+
+ An agent may or may not be able to tell if fundamental
+ changes to the media of the interface have occurred and
+ necessitate an invalidation of this entry. For example, a
+ hot-pluggable ethernet card could be pulled out and replaced
+ by a token-ring card. In such a case, if the agent has such
+ knowledge of the change, it is recommended that it
+ invalidate this entry.
+
+ This object may not be modified if the associated
+ etherStatsStatus object is equal to valid(1)."
+ ::= { etherStatsEntry 2 }
+
+etherStatsDropEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of events in which packets
+ were dropped by the probe due to lack of resources.
+ Note that this number is not necessarily the number of
+ packets dropped; it is just the number of times this
+ condition has been detected."
+ ::= { etherStatsEntry 3 }
+
+etherStatsOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets of data (including
+ those in bad packets) received on the
+ network (excluding framing bits but including
+ FCS octets).
+
+ This object can be used as a reasonable estimate of
+ 10-Megabit ethernet utilization. If greater precision is
+ desired, the etherStatsPkts and etherStatsOctets objects
+ should be sampled before and after a common interval. The
+ differences in the sampled values are Pkts and Octets,
+ respectively, and the number of seconds in the interval is
+ Interval. These values are used to calculate the Utilization
+ as follows:
+
+ Pkts * (9.6 + 6.4) + (Octets * .8)
+ Utilization = -------------------------------------
+ Interval * 10,000
+
+ The result of this equation is the value Utilization which
+ is the percent utilization of the ethernet segment on a
+ scale of 0 to 100 percent."
+ ::= { etherStatsEntry 4 }
+
+etherStatsPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad packets,
+ broadcast packets, and multicast packets) received."
+ ::= { etherStatsEntry 5 }
+
+etherStatsBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of good packets received that were
+ directed to the broadcast address. Note that this
+ does not include multicast packets."
+ ::= { etherStatsEntry 6 }
+
+etherStatsMulticastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of good packets received that were
+ directed to a multicast address. Note that this number
+ does not include packets directed to the broadcast
+
+ address."
+ ::= { etherStatsEntry 7 }
+
+etherStatsCRCAlignErrors OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received that
+ had a length (excluding framing bits, but
+ including FCS octets) of between 64 and 1518
+ octets, inclusive, but had either a bad
+ Frame Check Sequence (FCS) with an integral
+ number of octets (FCS Error) or a bad FCS with
+ a non-integral number of octets (Alignment Error)."
+ ::= { etherStatsEntry 8 }
+
+etherStatsUndersizePkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received that were
+ less than 64 octets long (excluding framing bits,
+ but including FCS octets) and were otherwise well
+ formed."
+ ::= { etherStatsEntry 9 }
+
+etherStatsOversizePkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received that were
+ longer than 1518 octets (excluding framing bits,
+ but including FCS octets) and were otherwise
+ well formed."
+ ::= { etherStatsEntry 10 }
+
+etherStatsFragments OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received that were less than
+ 64 octets in length (excluding framing bits but including
+ FCS octets) and had either a bad Frame Check Sequence
+ (FCS) with an integral number of octets (FCS Error) or a
+ bad FCS with a non-integral number of octets (Alignment
+ Error).
+
+ Note that it is entirely normal for etherStatsFragments to
+ increment. This is because it counts both runts (which are
+ normal occurrences due to collisions) and noise hits."
+ ::= { etherStatsEntry 11 }
+
+etherStatsJabbers OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received that were
+ longer than 1518 octets (excluding framing bits,
+ but including FCS octets), and had either a bad
+ Frame Check Sequence (FCS) with an integral number
+ of octets (FCS Error) or a bad FCS with a non-integral
+ number of octets (Alignment Error).
+
+ Note that this definition of jabber is different
+ than the definition in IEEE-802.3 section 8.2.1.5
+ (10BASE5) and section 10.3.1.4 (10BASE2). These
+ documents define jabber as the condition where any
+ packet exceeds 20 ms. The allowed range to detect
+ jabber is between 20 ms and 150 ms."
+ ::= { etherStatsEntry 12 }
+
+etherStatsCollisions OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Collisions"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The best estimate of the total number of collisions
+ on this Ethernet segment.
+
+ The value returned will depend on the location of the
+ RMON probe. Section 8.2.1.3 (10BASE-5) and section
+ 10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a
+ station must detect a collision, in the receive mode, if
+ three or more stations are transmitting simultaneously. A
+ repeater port must detect a collision when two or more
+
+ stations are transmitting simultaneously. Thus a probe
+ placed on a repeater port could record more collisions
+ than a probe connected to a station on the same segment
+ would.
+
+ Probe location plays a much smaller role when considering
+ 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE standard 802.3
+ defines a collision as the simultaneous presence of signals
+ on the DO and RD circuits (transmitting and receiving
+ at the same time). A 10BASE-T station can only detect
+ collisions when it is transmitting. Thus probes placed on
+ a station and a repeater, should report the same number of
+ collisions.
+
+ Note also that an RMON probe inside a repeater should
+ ideally report collisions between the repeater and one or
+ more other hosts (transmit collisions as defined by IEEE
+ 802.3k) plus receiver collisions observed on any coax
+ segments to which the repeater is connected."
+ ::= { etherStatsEntry 13 }
+
+etherStatsPkts64Octets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) received that were 64 octets in length
+ (excluding framing bits but including FCS octets)."
+ ::= { etherStatsEntry 14 }
+
+etherStatsPkts65to127Octets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) received that were between
+ 65 and 127 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { etherStatsEntry 15 }
+
+etherStatsPkts128to255Octets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) received that were between
+ 128 and 255 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { etherStatsEntry 16 }
+
+etherStatsPkts256to511Octets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) received that were between
+ 256 and 511 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { etherStatsEntry 17 }
+
+etherStatsPkts512to1023Octets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) received that were between
+ 512 and 1023 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { etherStatsEntry 18 }
+
+etherStatsPkts1024to1518Octets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets (including bad
+ packets) received that were between
+ 1024 and 1518 octets in length inclusive
+ (excluding framing bits but including FCS octets)."
+ ::= { etherStatsEntry 19 }
+
+etherStatsOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it."
+ ::= { etherStatsEntry 20 }
+
+etherStatsStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this etherStats entry."
+ ::= { etherStatsEntry 21 }
+
+-- The History Control Group
+
+-- Implementation of the History Control group is optional.
+-- Consult the MODULE-COMPLIANCE macro for the authoritative
+-- conformance information for this MIB.
+--
+-- The history control group controls the periodic statistical
+-- sampling of data from various types of networks. The
+-- historyControlTable stores configuration entries that each
+-- define an interface, polling period, and other parameters.
+-- Once samples are taken, their data is stored in an entry
+-- in a media-specific table. Each such entry defines one
+-- sample, and is associated with the historyControlEntry that
+-- caused the sample to be taken. Each counter in the
+-- etherHistoryEntry counts the same event as its similarly-named
+-- counterpart in the etherStatsEntry, except that each value here
+-- is a cumulative sum during a sampling period.
+--
+-- If the probe keeps track of the time of day, it should start
+-- the first sample of the history at a time such that
+-- when the next hour of the day begins, a sample is
+-- started at that instant. This tends to make more
+-- user-friendly reports, and enables comparison of reports
+-- from different probes that have relatively accurate time
+-- of day.
+--
+-- The probe is encouraged to add two history control entries
+-- per monitored interface upon initialization that describe a short
+-- term and a long term polling period. Suggested parameters are 30
+-- seconds for the short term polling period and 30 minutes for
+-- the long term period.
+
+historyControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HistoryControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of history control entries."
+ ::= { history 1 }
+
+historyControlEntry OBJECT-TYPE
+ SYNTAX HistoryControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of parameters that set up a periodic sampling of
+ statistics. As an example, an instance of the
+ historyControlInterval object might be named
+ historyControlInterval.2"
+ INDEX { historyControlIndex }
+ ::= { historyControlTable 1 }
+
+HistoryControlEntry ::= SEQUENCE {
+ historyControlIndex Integer32,
+ historyControlDataSource OBJECT IDENTIFIER,
+ historyControlBucketsRequested Integer32,
+ historyControlBucketsGranted Integer32,
+ historyControlInterval Integer32,
+ historyControlOwner OwnerString,
+ historyControlStatus EntryStatus
+}
+
+historyControlIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ historyControl table. Each such entry defines a
+ set of samples at a particular interval for an
+ interface on the device."
+ ::= { historyControlEntry 1 }
+
+historyControlDataSource OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object identifies the source of the data for
+ which historical data was collected and
+ placed in a media-specific table on behalf of this
+ historyControlEntry. This source can be any
+ interface on this device. In order to identify
+
+ a particular interface, this object shall identify
+ the instance of the ifIndex object, defined
+ in RFC 2233 [17], for the desired interface.
+ For example, if an entry were to receive data from
+ interface #1, this object would be set to ifIndex.1.
+
+ The statistics in this group reflect all packets
+ on the local network segment attached to the identified
+ interface.
+
+ An agent may or may not be able to tell if fundamental
+ changes to the media of the interface have occurred and
+ necessitate an invalidation of this entry. For example, a
+ hot-pluggable ethernet card could be pulled out and replaced
+ by a token-ring card. In such a case, if the agent has such
+ knowledge of the change, it is recommended that it
+ invalidate this entry.
+
+ This object may not be modified if the associated
+ historyControlStatus object is equal to valid(1)."
+ ::= { historyControlEntry 2 }
+
+historyControlBucketsRequested OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The requested number of discrete time intervals
+ over which data is to be saved in the part of the
+ media-specific table associated with this
+ historyControlEntry.
+
+ When this object is created or modified, the probe
+ should set historyControlBucketsGranted as closely to
+ this object as is possible for the particular probe
+ implementation and available resources."
+ DEFVAL { 50 }
+ ::= { historyControlEntry 3 }
+
+historyControlBucketsGranted OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of discrete sampling intervals
+ over which data shall be saved in the part of
+ the media-specific table associated with this
+ historyControlEntry.
+
+ When the associated historyControlBucketsRequested
+ object is created or modified, the probe
+ should set this object as closely to the requested
+ value as is possible for the particular
+ probe implementation and available resources. The
+ probe must not lower this value except as a result
+ of a modification to the associated
+ historyControlBucketsRequested object.
+
+ There will be times when the actual number of
+ buckets associated with this entry is less than
+ the value of this object. In this case, at the
+ end of each sampling interval, a new bucket will
+ be added to the media-specific table.
+
+ When the number of buckets reaches the value of
+ this object and a new bucket is to be added to the
+ media-specific table, the oldest bucket associated
+ with this historyControlEntry shall be deleted by
+ the agent so that the new bucket can be added.
+
+ When the value of this object changes to a value less
+ than the current value, entries are deleted
+ from the media-specific table associated with this
+ historyControlEntry. Enough of the oldest of these
+ entries shall be deleted by the agent so that their
+ number remains less than or equal to the new value of
+ this object.
+
+ When the value of this object changes to a value greater
+ than the current value, the number of associated media-
+ specific entries may be allowed to grow."
+ ::= { historyControlEntry 4 }
+
+historyControlInterval OBJECT-TYPE
+ SYNTAX Integer32 (1..3600)
+ UNITS "Seconds"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The interval in seconds over which the data is
+ sampled for each bucket in the part of the
+ media-specific table associated with this
+ historyControlEntry. This interval can
+ be set to any number of seconds between 1 and
+ 3600 (1 hour).
+
+ Because the counters in a bucket may overflow at their
+
+ maximum value with no indication, a prudent manager will
+ take into account the possibility of overflow in any of
+ the associated counters. It is important to consider the
+ minimum time in which any counter could overflow on a
+ particular media type and set the historyControlInterval
+ object to a value less than this interval. This is
+ typically most important for the 'octets' counter in any
+ media-specific table. For example, on an Ethernet
+ network, the etherHistoryOctets counter could overflow
+ in about one hour at the Ethernet's maximum
+ utilization.
+
+ This object may not be modified if the associated
+ historyControlStatus object is equal to valid(1)."
+ DEFVAL { 1800 }
+ ::= { historyControlEntry 5 }
+
+historyControlOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it."
+ ::= { historyControlEntry 6 }
+
+historyControlStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this historyControl entry.
+
+ Each instance of the media-specific table associated
+ with this historyControlEntry will be deleted by the agent
+ if this historyControlEntry is not equal to valid(1)."
+ ::= { historyControlEntry 7 }
+
+-- The Ethernet History Group
+
+-- Implementation of the Ethernet History group is optional.
+-- Consult the MODULE-COMPLIANCE macro for the authoritative
+-- conformance information for this MIB.
+--
+-- The Ethernet History group records periodic statistical samples
+-- from a network and stores them for later retrieval.
+-- Once samples are taken, their data is stored in an entry
+-- in a media-specific table. Each such entry defines one
+
+-- sample, and is associated with the historyControlEntry that
+-- caused the sample to be taken. This group defines the
+-- etherHistoryTable, for Ethernet networks.
+--
+
+etherHistoryTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EtherHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of Ethernet history entries."
+ ::= { history 2 }
+
+etherHistoryEntry OBJECT-TYPE
+ SYNTAX EtherHistoryEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An historical sample of Ethernet statistics on a particular
+ Ethernet interface. This sample is associated with the
+ historyControlEntry which set up the parameters for
+ a regular collection of these samples. As an example, an
+ instance of the etherHistoryPkts object might be named
+ etherHistoryPkts.2.89"
+ INDEX { etherHistoryIndex , etherHistorySampleIndex }
+ ::= { etherHistoryTable 1 }
+
+EtherHistoryEntry ::= SEQUENCE {
+ etherHistoryIndex Integer32,
+ etherHistorySampleIndex Integer32,
+ etherHistoryIntervalStart TimeTicks,
+ etherHistoryDropEvents Counter32,
+ etherHistoryOctets Counter32,
+ etherHistoryPkts Counter32,
+ etherHistoryBroadcastPkts Counter32,
+ etherHistoryMulticastPkts Counter32,
+ etherHistoryCRCAlignErrors Counter32,
+ etherHistoryUndersizePkts Counter32,
+ etherHistoryOversizePkts Counter32,
+ etherHistoryFragments Counter32,
+ etherHistoryJabbers Counter32,
+ etherHistoryCollisions Counter32,
+ etherHistoryUtilization Integer32
+}
+
+etherHistoryIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The history of which this entry is a part. The
+ history identified by a particular value of this
+ index is the same history as identified
+ by the same value of historyControlIndex."
+ ::= { etherHistoryEntry 1 }
+
+etherHistorySampleIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies the particular
+ sample this entry represents among all samples
+ associated with the same historyControlEntry.
+ This index starts at 1 and increases by one
+ as each new sample is taken."
+ ::= { etherHistoryEntry 2 }
+
+etherHistoryIntervalStart OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime at the start of the interval
+ over which this sample was measured. If the probe
+ keeps track of the time of day, it should start
+ the first sample of the history at a time such that
+ when the next hour of the day begins, a sample is
+ started at that instant. Note that following this
+ rule may require the probe to delay collecting the
+ first sample of the history, as each sample must be
+ of the same interval. Also note that the sample which
+ is currently being collected is not accessible in this
+ table until the end of its interval."
+ ::= { etherHistoryEntry 3 }
+
+etherHistoryDropEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of events in which packets
+ were dropped by the probe due to lack of resources
+ during this sampling interval. Note that this number
+ is not necessarily the number of packets dropped, it
+ is just the number of times this condition has been
+
+ detected."
+ ::= { etherHistoryEntry 4 }
+
+etherHistoryOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of octets of data (including
+ those in bad packets) received on the
+ network (excluding framing bits but including
+ FCS octets)."
+ ::= { etherHistoryEntry 5 }
+
+etherHistoryPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets (including bad packets)
+ received during this sampling interval."
+ ::= { etherHistoryEntry 6 }
+
+etherHistoryBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of good packets received during this
+ sampling interval that were directed to the
+ broadcast address."
+ ::= { etherHistoryEntry 7 }
+
+etherHistoryMulticastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of good packets received during this
+ sampling interval that were directed to a
+ multicast address. Note that this number does not
+ include packets addressed to the broadcast address."
+ ::= { etherHistoryEntry 8 }
+
+etherHistoryCRCAlignErrors OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets received during this
+ sampling interval that had a length (excluding
+ framing bits but including FCS octets) between
+ 64 and 1518 octets, inclusive, but had either a bad Frame
+ Check Sequence (FCS) with an integral number of octets
+ (FCS Error) or a bad FCS with a non-integral number
+ of octets (Alignment Error)."
+ ::= { etherHistoryEntry 9 }
+
+etherHistoryUndersizePkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets received during this
+ sampling interval that were less than 64 octets
+ long (excluding framing bits but including FCS
+ octets) and were otherwise well formed."
+ ::= { etherHistoryEntry 10 }
+
+etherHistoryOversizePkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets received during this
+ sampling interval that were longer than 1518
+ octets (excluding framing bits but including
+ FCS octets) but were otherwise well formed."
+ ::= { etherHistoryEntry 11 }
+
+etherHistoryFragments OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The total number of packets received during this
+ sampling interval that were less than 64 octets in
+ length (excluding framing bits but including FCS
+
+ octets) had either a bad Frame Check Sequence (FCS)
+ with an integral number of octets (FCS Error) or a bad
+ FCS with a non-integral number of octets (Alignment
+ Error).
+
+ Note that it is entirely normal for etherHistoryFragments to
+ increment. This is because it counts both runts (which are
+ normal occurrences due to collisions) and noise hits."
+ ::= { etherHistoryEntry 12 }
+
+etherHistoryJabbers OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets received during this
+ sampling interval that were longer than 1518 octets
+ (excluding framing bits but including FCS octets),
+ and had either a bad Frame Check Sequence (FCS)
+ with an integral number of octets (FCS Error) or
+ a bad FCS with a non-integral number of octets
+ (Alignment Error).
+
+ Note that this definition of jabber is different
+ than the definition in IEEE-802.3 section 8.2.1.5
+ (10BASE5) and section 10.3.1.4 (10BASE2). These
+ documents define jabber as the condition where any
+ packet exceeds 20 ms. The allowed range to detect
+ jabber is between 20 ms and 150 ms."
+ ::= { etherHistoryEntry 13 }
+
+etherHistoryCollisions OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Collisions"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The best estimate of the total number of collisions
+ on this Ethernet segment during this sampling
+ interval.
+
+ The value returned will depend on the location of the
+ RMON probe. Section 8.2.1.3 (10BASE-5) and section
+ 10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a
+ station must detect a collision, in the receive mode, if
+ three or more stations are transmitting simultaneously. A
+ repeater port must detect a collision when two or more
+
+ stations are transmitting simultaneously. Thus a probe
+ placed on a repeater port could record more collisions
+ than a probe connected to a station on the same segment
+ would.
+
+ Probe location plays a much smaller role when considering
+ 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE standard 802.3
+ defines a collision as the simultaneous presence of signals
+ on the DO and RD circuits (transmitting and receiving
+ at the same time). A 10BASE-T station can only detect
+ collisions when it is transmitting. Thus probes placed on
+ a station and a repeater, should report the same number of
+ collisions.
+
+ Note also that an RMON probe inside a repeater should
+ ideally report collisions between the repeater and one or
+ more other hosts (transmit collisions as defined by IEEE
+ 802.3k) plus receiver collisions observed on any coax
+ segments to which the repeater is connected."
+ ::= { etherHistoryEntry 14 }
+
+etherHistoryUtilization OBJECT-TYPE
+ SYNTAX Integer32 (0..10000)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The best estimate of the mean physical layer
+ network utilization on this interface during this
+ sampling interval, in hundredths of a percent."
+ ::= { etherHistoryEntry 15 }
+
+-- The Alarm Group
+
+-- Implementation of the Alarm group is optional. The Alarm Group
+-- requires the implementation of the Event group.
+-- Consult the MODULE-COMPLIANCE macro for the authoritative
+-- conformance information for this MIB.
+--
+-- The Alarm group periodically takes statistical samples from
+-- variables in the probe and compares them to thresholds that have
+-- been configured. The alarm table stores configuration
+-- entries that each define a variable, polling period, and
+-- threshold parameters. If a sample is found to cross the
+-- threshold values, an event is generated. Only variables that
+-- resolve to an ASN.1 primitive type of INTEGER (INTEGER, Integer32,
+-- Counter32, Counter64, Gauge32, or TimeTicks) may be monitored in
+-- this way.
+--
+
+-- This function has a hysteresis mechanism to limit the generation
+-- of events. This mechanism generates one event as a threshold
+-- is crossed in the appropriate direction. No more events are
+-- generated for that threshold until the opposite threshold is
+-- crossed.
+--
+-- In the case of a sampling a deltaValue, a probe may implement
+-- this mechanism with more precision if it takes a delta sample
+-- twice per period, each time comparing the sum of the latest two
+-- samples to the threshold. This allows the detection of threshold
+-- crossings that span the sampling boundary. Note that this does
+-- not require any special configuration of the threshold value.
+-- It is suggested that probes implement this more precise algorithm.
+
+alarmTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF AlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of alarm entries."
+ ::= { alarm 1 }
+
+alarmEntry OBJECT-TYPE
+ SYNTAX AlarmEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of parameters that set up a periodic checking
+ for alarm conditions. For example, an instance of the
+ alarmValue object might be named alarmValue.8"
+ INDEX { alarmIndex }
+ ::= { alarmTable 1 }
+
+AlarmEntry ::= SEQUENCE {
+ alarmIndex Integer32,
+ alarmInterval Integer32,
+ alarmVariable OBJECT IDENTIFIER,
+ alarmSampleType INTEGER,
+ alarmValue Integer32,
+ alarmStartupAlarm INTEGER,
+ alarmRisingThreshold Integer32,
+ alarmFallingThreshold Integer32,
+ alarmRisingEventIndex Integer32,
+ alarmFallingEventIndex Integer32,
+ alarmOwner OwnerString,
+ alarmStatus EntryStatus
+}
+
+alarmIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ alarm table. Each such entry defines a
+ diagnostic sample at a particular interval
+ for an object on the device."
+ ::= { alarmEntry 1 }
+
+alarmInterval OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Seconds"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The interval in seconds over which the data is
+ sampled and compared with the rising and falling
+ thresholds. When setting this variable, care
+ should be taken in the case of deltaValue
+ sampling - the interval should be set short enough
+ that the sampled variable is very unlikely to
+ increase or decrease by more than 2^31 - 1 during
+ a single sampling interval.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 2 }
+
+alarmVariable OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The object identifier of the particular variable to be
+ sampled. Only variables that resolve to an ASN.1 primitive
+ type of INTEGER (INTEGER, Integer32, Counter32, Counter64,
+ Gauge, or TimeTicks) may be sampled.
+
+ Because SNMP access control is articulated entirely
+ in terms of the contents of MIB views, no access
+ control mechanism exists that can restrict the value of
+ this object to identify only those objects that exist
+ in a particular MIB view. Because there is thus no
+ acceptable means of restricting the read access that
+ could be obtained through the alarm mechanism, the
+ probe must only grant write access to this object in
+
+ those views that have read access to all objects on
+ the probe.
+
+ During a set operation, if the supplied variable name is
+ not available in the selected MIB view, a badValue error
+ must be returned. If at any time the variable name of
+ an established alarmEntry is no longer available in the
+ selected MIB view, the probe must change the status of
+ this alarmEntry to invalid(4).
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 3 }
+
+alarmSampleType OBJECT-TYPE
+ SYNTAX INTEGER {
+ absoluteValue(1),
+ deltaValue(2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The method of sampling the selected variable and
+ calculating the value to be compared against the
+ thresholds. If the value of this object is
+ absoluteValue(1), the value of the selected variable
+ will be compared directly with the thresholds at the
+ end of the sampling interval. If the value of this
+ object is deltaValue(2), the value of the selected
+ variable at the last sample will be subtracted from
+ the current value, and the difference compared with
+ the thresholds.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 4 }
+
+alarmValue OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of the statistic during the last sampling
+ period. For example, if the sample type is deltaValue,
+ this value will be the difference between the samples
+ at the beginning and end of the period. If the sample
+ type is absoluteValue, this value will be the sampled
+ value at the end of the period.
+
+ This is the value that is compared with the rising and
+ falling thresholds.
+
+ The value during the current sampling period is not
+ made available until the period is completed and will
+ remain available until the next period completes."
+ ::= { alarmEntry 5 }
+
+alarmStartupAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ risingAlarm(1),
+ fallingAlarm(2),
+ risingOrFallingAlarm(3)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The alarm that may be sent when this entry is first
+ set to valid. If the first sample after this entry
+ becomes valid is greater than or equal to the
+ risingThreshold and alarmStartupAlarm is equal to
+ risingAlarm(1) or risingOrFallingAlarm(3), then a single
+ rising alarm will be generated. If the first sample
+ after this entry becomes valid is less than or equal
+ to the fallingThreshold and alarmStartupAlarm is equal
+ to fallingAlarm(2) or risingOrFallingAlarm(3), then a
+ single falling alarm will be generated.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 6 }
+
+alarmRisingThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "A threshold for the sampled statistic. When the current
+ sampled value is greater than or equal to this threshold,
+ and the value at the last sampling interval was less than
+ this threshold, a single event will be generated.
+ A single event will also be generated if the first
+ sample after this entry becomes valid is greater than or
+ equal to this threshold and the associated
+ alarmStartupAlarm is equal to risingAlarm(1) or
+ risingOrFallingAlarm(3).
+
+ After a rising event is generated, another such event
+
+ will not be generated until the sampled value
+ falls below this threshold and reaches the
+ alarmFallingThreshold.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 7 }
+
+alarmFallingThreshold OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "A threshold for the sampled statistic. When the current
+ sampled value is less than or equal to this threshold,
+ and the value at the last sampling interval was greater than
+ this threshold, a single event will be generated.
+ A single event will also be generated if the first
+ sample after this entry becomes valid is less than or
+ equal to this threshold and the associated
+ alarmStartupAlarm is equal to fallingAlarm(2) or
+ risingOrFallingAlarm(3).
+
+ After a falling event is generated, another such event
+ will not be generated until the sampled value
+ rises above this threshold and reaches the
+ alarmRisingThreshold.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 8 }
+
+alarmRisingEventIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The index of the eventEntry that is
+ used when a rising threshold is crossed. The
+ eventEntry identified by a particular value of
+ this index is the same as identified by the same value
+ of the eventIndex object. If there is no
+ corresponding entry in the eventTable, then
+ no association exists. In particular, if this value
+ is zero, no associated event will be generated, as
+ zero is not a valid event index.
+
+ This object may not be modified if the associated
+
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 9 }
+
+alarmFallingEventIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The index of the eventEntry that is
+ used when a falling threshold is crossed. The
+ eventEntry identified by a particular value of
+ this index is the same as identified by the same value
+ of the eventIndex object. If there is no
+ corresponding entry in the eventTable, then
+ no association exists. In particular, if this value
+ is zero, no associated event will be generated, as
+ zero is not a valid event index.
+
+ This object may not be modified if the associated
+ alarmStatus object is equal to valid(1)."
+ ::= { alarmEntry 10 }
+
+alarmOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it."
+ ::= { alarmEntry 11 }
+
+alarmStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this alarm entry."
+ ::= { alarmEntry 12 }
+
+-- The Host Group
+
+-- Implementation of the Host group is optional.
+-- Consult the MODULE-COMPLIANCE macro for the authoritative
+-- conformance information for this MIB.
+--
+-- The host group discovers new hosts on the network by
+-- keeping a list of source and destination MAC Addresses seen
+-- in good packets. For each of these addresses, the host group
+
+-- keeps a set of statistics. The hostControlTable controls
+-- which interfaces this function is performed on, and contains
+-- some information about the process. On behalf of each
+-- hostControlEntry, data is collected on an interface and placed
+-- in both the hostTable and the hostTimeTable. If the
+-- monitoring device finds itself short of resources, it may
+-- delete entries as needed. It is suggested that the device
+-- delete the least recently used entries first.
+
+-- The hostTable contains entries for each address discovered on
+-- a particular interface. Each entry contains statistical
+-- data about that host. This table is indexed by the
+-- MAC address of the host, through which a random access
+-- may be achieved.
+
+-- The hostTimeTable contains data in the same format as the
+-- hostTable, and must contain the same set of hosts, but is
+-- indexed using hostTimeCreationOrder rather than hostAddress.
+-- The hostTimeCreationOrder is an integer which reflects
+-- the relative order in which a particular entry was discovered
+-- and thus inserted into the table. As this order, and thus
+-- the index, is among those entries currently in the table,
+-- the index for a particular entry may change if an
+-- (earlier) entry is deleted. Thus the association between
+-- hostTimeCreationOrder and hostTimeEntry may be broken at
+-- any time.
+
+-- The hostTimeTable has two important uses. The first is the
+-- fast download of this potentially large table. Because the
+-- index of this table runs from 1 to the size of the table,
+-- inclusive, its values are predictable. This allows very
+-- efficient packing of variables into SNMP PDU's and allows
+-- a table transfer to have multiple packets outstanding.
+-- These benefits increase transfer rates tremendously.
+
+-- The second use of the hostTimeTable is the efficient discovery
+-- by the management station of new entries added to the table.
+-- After the management station has downloaded the entire table,
+-- it knows that new entries will be added immediately after the
+-- end of the current table. It can thus detect new entries there
+-- and retrieve them easily.
+
+-- Because the association between hostTimeCreationOrder and
+-- hostTimeEntry may be broken at any time, the management
+-- station must monitor the related hostControlLastDeleteTime
+-- object. When the management station thus detects a deletion,
+-- it must assume that any such associations have been broken,
+-- and invalidate any it has stored locally. This includes
+
+-- restarting any download of the hostTimeTable that may have been
+-- in progress, as well as rediscovering the end of the
+-- hostTimeTable so that it may detect new entries. If the
+-- management station does not detect the broken association,
+-- it may continue to refer to a particular host by its
+-- creationOrder while unwittingly retrieving the data associated
+-- with another host entirely. If this happens while downloading
+-- the host table, the management station may fail to download
+-- all of the entries in the table.
+
+hostControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of host table control entries."
+ ::= { hosts 1 }
+
+hostControlEntry OBJECT-TYPE
+ SYNTAX HostControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of parameters that set up the discovery of hosts
+ on a particular interface and the collection of statistics
+ about these hosts. For example, an instance of the
+ hostControlTableSize object might be named
+ hostControlTableSize.1"
+ INDEX { hostControlIndex }
+ ::= { hostControlTable 1 }
+
+HostControlEntry ::= SEQUENCE {
+
+ hostControlIndex Integer32,
+ hostControlDataSource OBJECT IDENTIFIER,
+ hostControlTableSize Integer32,
+ hostControlLastDeleteTime TimeTicks,
+ hostControlOwner OwnerString,
+ hostControlStatus EntryStatus
+}
+
+hostControlIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+
+ hostControl table. Each such entry defines
+ a function that discovers hosts on a particular interface
+ and places statistics about them in the hostTable and
+ the hostTimeTable on behalf of this hostControlEntry."
+ ::= { hostControlEntry 1 }
+
+hostControlDataSource OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object identifies the source of the data for
+ this instance of the host function. This source
+ can be any interface on this device. In order
+ to identify a particular interface, this object shall
+ identify the instance of the ifIndex object, defined
+ in RFC 2233 [17], for the desired interface.
+ For example, if an entry were to receive data from
+ interface #1, this object would be set to ifIndex.1.
+
+ The statistics in this group reflect all packets
+ on the local network segment attached to the identified
+ interface.
+
+ An agent may or may not be able to tell if fundamental
+ changes to the media of the interface have occurred and
+ necessitate an invalidation of this entry. For example, a
+ hot-pluggable ethernet card could be pulled out and replaced
+ by a token-ring card. In such a case, if the agent has such
+ knowledge of the change, it is recommended that it
+ invalidate this entry.
+
+ This object may not be modified if the associated
+ hostControlStatus object is equal to valid(1)."
+ ::= { hostControlEntry 2 }
+
+hostControlTableSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of hostEntries in the hostTable and the
+ hostTimeTable associated with this hostControlEntry."
+ ::= { hostControlEntry 3 }
+
+hostControlLastDeleteTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when the last entry
+ was deleted from the portion of the hostTable
+ associated with this hostControlEntry. If no
+ deletions have occurred, this value shall be zero."
+ ::= { hostControlEntry 4 }
+
+hostControlOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it."
+ ::= { hostControlEntry 5 }
+
+hostControlStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this hostControl entry.
+
+ If this object is not equal to valid(1), all associated
+ entries in the hostTable, hostTimeTable, and the
+ hostTopNTable shall be deleted by the agent."
+ ::= { hostControlEntry 6 }
+
+hostTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of host entries."
+ ::= { hosts 2 }
+
+hostEntry OBJECT-TYPE
+ SYNTAX HostEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of statistics for a particular host that has
+ been discovered on an interface of this device. For example,
+ an instance of the hostOutBroadcastPkts object might be
+ named hostOutBroadcastPkts.1.6.8.0.32.27.3.176"
+ INDEX { hostIndex, hostAddress }
+ ::= { hostTable 1 }
+
+HostEntry ::= SEQUENCE {
+ hostAddress OCTET STRING,
+ hostCreationOrder Integer32,
+ hostIndex Integer32,
+ hostInPkts Counter32,
+ hostOutPkts Counter32,
+ hostInOctets Counter32,
+ hostOutOctets Counter32,
+ hostOutErrors Counter32,
+ hostOutBroadcastPkts Counter32,
+ hostOutMulticastPkts Counter32
+}
+
+hostAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The physical address of this host."
+ ::= { hostEntry 1 }
+
+hostCreationOrder OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that defines the relative ordering of
+ the creation time of hosts captured for a
+ particular hostControlEntry. This index shall
+ be between 1 and N, where N is the value of
+ the associated hostControlTableSize. The ordering
+ of the indexes is based on the order of each entry's
+ insertion into the table, in which entries added earlier
+ have a lower index value than entries added later.
+
+ It is important to note that the order for a
+ particular entry may change as an (earlier) entry
+ is deleted from the table. Because this order may
+ change, management stations should make use of the
+ hostControlLastDeleteTime variable in the
+ hostControlEntry associated with the relevant
+ portion of the hostTable. By observing
+ this variable, the management station may detect
+ the circumstances where a previous association
+ between a value of hostCreationOrder
+ and a hostEntry may no longer hold."
+ ::= { hostEntry 2 }
+
+hostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The set of collected host statistics of which
+ this entry is a part. The set of hosts
+ identified by a particular value of this
+ index is associated with the hostControlEntry
+ as identified by the same value of hostControlIndex."
+ ::= { hostEntry 3 }
+
+hostInPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of good packets transmitted to this
+ address since it was added to the hostTable."
+ ::= { hostEntry 4 }
+
+hostOutPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets, including bad packets, transmitted
+ by this address since it was added to the hostTable."
+ ::= { hostEntry 5 }
+
+hostInOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of octets transmitted to this address since
+ it was added to the hostTable (excluding framing
+ bits but including FCS octets), except for those
+ octets in bad packets."
+ ::= { hostEntry 6 }
+
+hostOutOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of octets transmitted by this address since
+ it was added to the hostTable (excluding framing
+ bits but including FCS octets), including those
+ octets in bad packets."
+ ::= { hostEntry 7 }
+
+hostOutErrors OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bad packets transmitted by this address
+ since this host was added to the hostTable."
+ ::= { hostEntry 8 }
+
+hostOutBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of good packets transmitted by this
+ address that were directed to the broadcast address
+ since this host was added to the hostTable."
+ ::= { hostEntry 9 }
+
+hostOutMulticastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of good packets transmitted by this
+ address that were directed to a multicast address
+ since this host was added to the hostTable.
+ Note that this number does not include packets
+ directed to the broadcast address."
+ ::= { hostEntry 10 }
+
+-- host Time Table
+
+hostTimeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostTimeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of time-ordered host table entries."
+ ::= { hosts 3 }
+
+hostTimeEntry OBJECT-TYPE
+ SYNTAX HostTimeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of statistics for a particular host that has
+ been discovered on an interface of this device. This
+ collection includes the relative ordering of the creation
+ time of this object. For example, an instance of the
+ hostTimeOutBroadcastPkts object might be named
+ hostTimeOutBroadcastPkts.1.687"
+ INDEX { hostTimeIndex, hostTimeCreationOrder }
+ ::= { hostTimeTable 1 }
+
+HostTimeEntry ::= SEQUENCE {
+ hostTimeAddress OCTET STRING,
+ hostTimeCreationOrder Integer32,
+ hostTimeIndex Integer32,
+ hostTimeInPkts Counter32,
+ hostTimeOutPkts Counter32,
+ hostTimeInOctets Counter32,
+ hostTimeOutOctets Counter32,
+ hostTimeOutErrors Counter32,
+ hostTimeOutBroadcastPkts Counter32,
+ hostTimeOutMulticastPkts Counter32
+}
+
+hostTimeAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The physical address of this host."
+ ::= { hostTimeEntry 1 }
+
+hostTimeCreationOrder OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in
+ the hostTime table among those entries associated
+ with the same hostControlEntry. This index shall
+ be between 1 and N, where N is the value of
+
+ the associated hostControlTableSize. The ordering
+ of the indexes is based on the order of each entry's
+ insertion into the table, in which entries added earlier
+ have a lower index value than entries added later.
+ Thus the management station has the ability to
+ learn of new entries added to this table without
+ downloading the entire table.
+
+ It is important to note that the index for a
+ particular entry may change as an (earlier) entry
+ is deleted from the table. Because this order may
+ change, management stations should make use of the
+ hostControlLastDeleteTime variable in the
+ hostControlEntry associated with the relevant
+ portion of the hostTimeTable. By observing
+ this variable, the management station may detect
+ the circumstances where a download of the table
+ may have missed entries, and where a previous
+ association between a value of hostTimeCreationOrder
+ and a hostTimeEntry may no longer hold."
+ ::= { hostTimeEntry 2 }
+
+hostTimeIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The set of collected host statistics of which
+ this entry is a part. The set of hosts
+ identified by a particular value of this
+ index is associated with the hostControlEntry
+ as identified by the same value of hostControlIndex."
+ ::= { hostTimeEntry 3 }
+
+hostTimeInPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of good packets transmitted to this
+ address since it was added to the hostTimeTable."
+ ::= { hostTimeEntry 4 }
+
+hostTimeOutPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets, including bad packets, transmitted
+ by this address since it was added to the hostTimeTable."
+ ::= { hostTimeEntry 5 }
+
+hostTimeInOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of octets transmitted to this address since
+ it was added to the hostTimeTable (excluding framing
+ bits but including FCS octets), except for those
+ octets in bad packets."
+ ::= { hostTimeEntry 6 }
+
+hostTimeOutOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of octets transmitted by this address since
+ it was added to the hostTimeTable (excluding framing
+ bits but including FCS octets), including those
+ octets in bad packets."
+ ::= { hostTimeEntry 7 }
+
+hostTimeOutErrors OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bad packets transmitted by this address
+ since this host was added to the hostTimeTable."
+ ::= { hostTimeEntry 8 }
+
+hostTimeOutBroadcastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of good packets transmitted by this
+ address that were directed to the broadcast address
+
+ since this host was added to the hostTimeTable."
+ ::= { hostTimeEntry 9 }
+
+hostTimeOutMulticastPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of good packets transmitted by this
+ address that were directed to a multicast address
+ since this host was added to the hostTimeTable.
+ Note that this number does not include packets directed
+ to the broadcast address."
+ ::= { hostTimeEntry 10 }
+
+-- The Host Top "N" Group
+
+-- Implementation of the Host Top N group is optional. The Host Top N
+-- group requires the implementation of the host group.
+-- Consult the MODULE-COMPLIANCE macro for the authoritative
+-- conformance information for this MIB.
+--
+-- The Host Top N group is used to prepare reports that describe
+-- the hosts that top a list ordered by one of their statistics.
+-- The available statistics are samples of one of their
+-- base statistics, over an interval specified by the management
+-- station. Thus, these statistics are rate based. The management
+-- station also selects how many such hosts are reported.
+
+-- The hostTopNControlTable is used to initiate the generation of
+-- such a report. The management station may select the parameters
+-- of such a report, such as which interface, which statistic,
+-- how many hosts, and the start and stop times of the sampling.
+-- When the report is prepared, entries are created in the
+-- hostTopNTable associated with the relevant hostTopNControlEntry.
+-- These entries are static for each report after it has been
+-- prepared.
+
+hostTopNControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostTopNControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of top N host control entries."
+ ::= { hostTopN 1 }
+
+hostTopNControlEntry OBJECT-TYPE
+ SYNTAX HostTopNControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A set of parameters that control the creation of a report
+ of the top N hosts according to several metrics. For
+ example, an instance of the hostTopNDuration object might
+ be named hostTopNDuration.3"
+ INDEX { hostTopNControlIndex }
+ ::= { hostTopNControlTable 1 }
+
+HostTopNControlEntry ::= SEQUENCE {
+ hostTopNControlIndex Integer32,
+ hostTopNHostIndex Integer32,
+ hostTopNRateBase INTEGER,
+ hostTopNTimeRemaining Integer32,
+ hostTopNDuration Integer32,
+ hostTopNRequestedSize Integer32,
+ hostTopNGrantedSize Integer32,
+ hostTopNStartTime TimeTicks,
+ hostTopNOwner OwnerString,
+ hostTopNStatus EntryStatus
+}
+
+hostTopNControlIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry
+ in the hostTopNControl table. Each such
+ entry defines one top N report prepared for
+ one interface."
+ ::= { hostTopNControlEntry 1 }
+
+hostTopNHostIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The host table for which a top N report will be prepared
+ on behalf of this entry. The host table identified by a
+ particular value of this index is associated with the same
+ host table as identified by the same value of
+ hostIndex.
+
+ This object may not be modified if the associated
+ hostTopNStatus object is equal to valid(1)."
+ ::= { hostTopNControlEntry 2 }
+
+hostTopNRateBase OBJECT-TYPE
+ SYNTAX INTEGER {
+ hostTopNInPkts(1),
+ hostTopNOutPkts(2),
+ hostTopNInOctets(3),
+ hostTopNOutOctets(4),
+ hostTopNOutErrors(5),
+ hostTopNOutBroadcastPkts(6),
+ hostTopNOutMulticastPkts(7)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The variable for each host that the hostTopNRate
+ variable is based upon.
+
+ This object may not be modified if the associated
+ hostTopNStatus object is equal to valid(1)."
+ ::= { hostTopNControlEntry 3 }
+
+hostTopNTimeRemaining OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Seconds"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The number of seconds left in the report currently being
+ collected. When this object is modified by the management
+ station, a new collection is started, possibly aborting
+ a currently running report. The new value is used
+ as the requested duration of this report, which is
+ loaded into the associated hostTopNDuration object.
+
+ When this object is set to a non-zero value, any
+ associated hostTopNEntries shall be made
+ inaccessible by the monitor. While the value of this
+ object is non-zero, it decrements by one per second until
+ it reaches zero. During this time, all associated
+ hostTopNEntries shall remain inaccessible. At the time
+ that this object decrements to zero, the report is made
+ accessible in the hostTopNTable. Thus, the hostTopN
+ table needs to be created only at the end of the collection
+ interval."
+ DEFVAL { 0 }
+ ::= { hostTopNControlEntry 4 }
+
+hostTopNDuration OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Seconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of seconds that this report has collected
+ during the last sampling interval, or if this
+ report is currently being collected, the number
+ of seconds that this report is being collected
+ during this sampling interval.
+
+ When the associated hostTopNTimeRemaining object is set,
+ this object shall be set by the probe to the same value
+ and shall not be modified until the next time
+ the hostTopNTimeRemaining is set.
+
+ This value shall be zero if no reports have been
+ requested for this hostTopNControlEntry."
+ DEFVAL { 0 }
+ ::= { hostTopNControlEntry 5 }
+
+hostTopNRequestedSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The maximum number of hosts requested for the top N
+ table.
+
+ When this object is created or modified, the probe
+ should set hostTopNGrantedSize as closely to this
+ object as is possible for the particular probe
+ implementation and available resources."
+ DEFVAL { 10 }
+ ::= { hostTopNControlEntry 6 }
+
+hostTopNGrantedSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of hosts in the top N table.
+
+ When the associated hostTopNRequestedSize object is
+ created or modified, the probe should set this
+ object as closely to the requested value as is possible
+ for the particular implementation and available
+
+ resources. The probe must not lower this value except
+ as a result of a set to the associated
+ hostTopNRequestedSize object.
+
+ Hosts with the highest value of hostTopNRate shall be
+ placed in this table in decreasing order of this rate
+ until there is no more room or until there are no more
+ hosts."
+ ::= { hostTopNControlEntry 7 }
+
+hostTopNStartTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when this top N report was
+ last started. In other words, this is the time that
+ the associated hostTopNTimeRemaining object was
+ modified to start the requested report."
+ ::= { hostTopNControlEntry 8 }
+
+hostTopNOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it."
+ ::= { hostTopNControlEntry 9 }
+
+hostTopNStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this hostTopNControl entry.
+
+ If this object is not equal to valid(1), all associated
+ hostTopNEntries shall be deleted by the agent."
+ ::= { hostTopNControlEntry 10 }
+
+hostTopNTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF HostTopNEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of top N host entries."
+ ::= { hostTopN 2 }
+
+hostTopNEntry OBJECT-TYPE
+ SYNTAX HostTopNEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A set of statistics for a host that is part of a top N
+ report. For example, an instance of the hostTopNRate
+ object might be named hostTopNRate.3.10"
+ INDEX { hostTopNReport, hostTopNIndex }
+ ::= { hostTopNTable 1 }
+
+HostTopNEntry ::= SEQUENCE {
+ hostTopNReport Integer32,
+ hostTopNIndex Integer32,
+ hostTopNAddress OCTET STRING,
+ hostTopNRate Integer32
+}
+
+hostTopNReport OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object identifies the top N report of which
+ this entry is a part. The set of hosts
+ identified by a particular value of this
+ object is part of the same report as identified
+ by the same value of the hostTopNControlIndex object."
+ ::= { hostTopNEntry 1 }
+
+hostTopNIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in
+ the hostTopN table among those in the same report.
+ This index is between 1 and N, where N is the
+ number of entries in this table. Increasing values
+ of hostTopNIndex shall be assigned to entries with
+ decreasing values of hostTopNRate until index N
+ is assigned to the entry with the lowest value of
+ hostTopNRate or there are no more hostTopNEntries."
+ ::= { hostTopNEntry 2 }
+
+hostTopNAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The physical address of this host."
+ ::= { hostTopNEntry 3 }
+
+hostTopNRate OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The amount of change in the selected variable
+ during this sampling interval. The selected
+ variable is this host's instance of the object
+ selected by hostTopNRateBase."
+ ::= { hostTopNEntry 4 }
+
+-- The Matrix Group
+
+-- Implementation of the Matrix group is optional.
+-- Consult the MODULE-COMPLIANCE macro for the authoritative
+-- conformance information for this MIB.
+--
+-- The Matrix group consists of the matrixControlTable, matrixSDTable
+-- and the matrixDSTable. These tables store statistics for a
+-- particular conversation between two addresses. As the device
+-- detects a new conversation, including those to a non-unicast
+-- address, it creates a new entry in both of the matrix tables.
+-- It must only create new entries based on information
+-- received in good packets. If the monitoring device finds
+-- itself short of resources, it may delete entries as needed.
+-- It is suggested that the device delete the least recently used
+-- entries first.
+
+matrixControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MatrixControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of information entries for the
+ traffic matrix on each interface."
+ ::= { matrix 1 }
+
+matrixControlEntry OBJECT-TYPE
+ SYNTAX MatrixControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Information about a traffic matrix on a particular
+
+ interface. For example, an instance of the
+ matrixControlLastDeleteTime object might be named
+ matrixControlLastDeleteTime.1"
+ INDEX { matrixControlIndex }
+ ::= { matrixControlTable 1 }
+
+MatrixControlEntry ::= SEQUENCE {
+ matrixControlIndex Integer32,
+ matrixControlDataSource OBJECT IDENTIFIER,
+ matrixControlTableSize Integer32,
+ matrixControlLastDeleteTime TimeTicks,
+ matrixControlOwner OwnerString,
+ matrixControlStatus EntryStatus
+}
+
+matrixControlIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ matrixControl table. Each such entry defines
+ a function that discovers conversations on a particular
+ interface and places statistics about them in the
+ matrixSDTable and the matrixDSTable on behalf of this
+ matrixControlEntry."
+ ::= { matrixControlEntry 1 }
+
+matrixControlDataSource OBJECT-TYPE
+ SYNTAX OBJECT IDENTIFIER
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object identifies the source of
+ the data from which this entry creates a traffic matrix.
+ This source can be any interface on this device. In
+ order to identify a particular interface, this object
+ shall identify the instance of the ifIndex object,
+ defined in RFC 2233 [17], for the desired
+ interface. For example, if an entry were to receive data
+ from interface #1, this object would be set to ifIndex.1.
+
+ The statistics in this group reflect all packets
+ on the local network segment attached to the identified
+ interface.
+
+ An agent may or may not be able to tell if fundamental
+ changes to the media of the interface have occurred and
+
+ necessitate an invalidation of this entry. For example, a
+ hot-pluggable ethernet card could be pulled out and replaced
+ by a token-ring card. In such a case, if the agent has such
+ knowledge of the change, it is recommended that it
+ invalidate this entry.
+
+ This object may not be modified if the associated
+ matrixControlStatus object is equal to valid(1)."
+ ::= { matrixControlEntry 2 }
+
+matrixControlTableSize OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of matrixSDEntries in the matrixSDTable
+ for this interface. This must also be the value of
+ the number of entries in the matrixDSTable for this
+ interface."
+ ::= { matrixControlEntry 3 }
+
+matrixControlLastDeleteTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when the last entry
+ was deleted from the portion of the matrixSDTable
+ or matrixDSTable associated with this matrixControlEntry.
+ If no deletions have occurred, this value shall be
+ zero."
+ ::= { matrixControlEntry 4 }
+
+matrixControlOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it."
+ ::= { matrixControlEntry 5 }
+
+matrixControlStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this matrixControl entry.
+
+ If this object is not equal to valid(1), all associated
+ entries in the matrixSDTable and the matrixDSTable
+ shall be deleted by the agent."
+ ::= { matrixControlEntry 6 }
+
+matrixSDTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MatrixSDEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of traffic matrix entries indexed by
+ source and destination MAC address."
+ ::= { matrix 2 }
+
+matrixSDEntry OBJECT-TYPE
+ SYNTAX MatrixSDEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of statistics for communications between
+ two addresses on a particular interface. For example,
+ an instance of the matrixSDPkts object might be named
+ matrixSDPkts.1.6.8.0.32.27.3.176.6.8.0.32.10.8.113"
+ INDEX { matrixSDIndex,
+ matrixSDSourceAddress, matrixSDDestAddress }
+ ::= { matrixSDTable 1 }
+
+MatrixSDEntry ::= SEQUENCE {
+ matrixSDSourceAddress OCTET STRING,
+ matrixSDDestAddress OCTET STRING,
+ matrixSDIndex Integer32,
+ matrixSDPkts Counter32,
+ matrixSDOctets Counter32,
+ matrixSDErrors Counter32
+}
+
+matrixSDSourceAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The source physical address."
+ ::= { matrixSDEntry 1 }
+
+matrixSDDestAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The destination physical address."
+ ::= { matrixSDEntry 2 }
+
+matrixSDIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The set of collected matrix statistics of which
+ this entry is a part. The set of matrix statistics
+ identified by a particular value of this index
+ is associated with the same matrixControlEntry
+ as identified by the same value of matrixControlIndex."
+ ::= { matrixSDEntry 3 }
+
+matrixSDPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets transmitted from the source
+ address to the destination address (this number includes
+ bad packets)."
+ ::= { matrixSDEntry 4 }
+
+matrixSDOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of octets (excluding framing bits but
+ including FCS octets) contained in all packets
+ transmitted from the source address to the
+ destination address."
+ ::= { matrixSDEntry 5 }
+
+matrixSDErrors OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bad packets transmitted from
+ the source address to the destination address."
+ ::= { matrixSDEntry 6 }
+
+-- Traffic matrix tables from destination to source
+
+matrixDSTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MatrixDSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of traffic matrix entries indexed by
+ destination and source MAC address."
+ ::= { matrix 3 }
+
+matrixDSEntry OBJECT-TYPE
+ SYNTAX MatrixDSEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A collection of statistics for communications between
+ two addresses on a particular interface. For example,
+ an instance of the matrixSDPkts object might be named
+ matrixSDPkts.1.6.8.0.32.10.8.113.6.8.0.32.27.3.176"
+ INDEX { matrixDSIndex,
+ matrixDSDestAddress, matrixDSSourceAddress }
+ ::= { matrixDSTable 1 }
+
+MatrixDSEntry ::= SEQUENCE {
+ matrixDSSourceAddress OCTET STRING,
+ matrixDSDestAddress OCTET STRING,
+ matrixDSIndex Integer32,
+ matrixDSPkts Counter32,
+ matrixDSOctets Counter32,
+ matrixDSErrors Counter32
+}
+
+matrixDSSourceAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The source physical address."
+ ::= { matrixDSEntry 1 }
+
+matrixDSDestAddress OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The destination physical address."
+ ::= { matrixDSEntry 2 }
+
+matrixDSIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The set of collected matrix statistics of which
+ this entry is a part. The set of matrix statistics
+ identified by a particular value of this index
+ is associated with the same matrixControlEntry
+ as identified by the same value of matrixControlIndex."
+ ::= { matrixDSEntry 3 }
+
+matrixDSPkts OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets transmitted from the source
+ address to the destination address (this number includes
+ bad packets)."
+ ::= { matrixDSEntry 4 }
+
+matrixDSOctets OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of octets (excluding framing bits
+ but including FCS octets) contained in all packets
+ transmitted from the source address to the
+ destination address."
+ ::= { matrixDSEntry 5 }
+
+matrixDSErrors OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of bad packets transmitted from
+ the source address to the destination address."
+ ::= { matrixDSEntry 6 }
+
+-- The Filter Group
+
+-- Implementation of the Filter group is optional.
+
+-- Consult the MODULE-COMPLIANCE macro for the authoritative
+-- conformance information for this MIB.
+--
+-- The Filter group allows packets to be captured with an
+-- arbitrary filter expression. A logical data and
+-- event stream or "channel" is formed by the packets
+-- that match the filter expression.
+--
+-- This filter mechanism allows the creation of an arbitrary
+-- logical expression with which to filter packets. Each
+-- filter associated with a channel is OR'ed with the others.
+-- Within a filter, any bits checked in the data and status are
+-- AND'ed with respect to other bits in the same filter. The
+-- NotMask also allows for checking for inequality. Finally,
+-- the channelAcceptType object allows for inversion of the
+-- whole equation.
+--
+-- If a management station wishes to receive a trap to alert it
+-- that new packets have been captured and are available for
+-- download, it is recommended that it set up an alarm entry that
+-- monitors the value of the relevant channelMatches instance.
+--
+-- The channel can be turned on or off, and can also
+-- generate events when packets pass through it.
+
+filterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF FilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of packet filter entries."
+ ::= { filter 1 }
+
+filterEntry OBJECT-TYPE
+ SYNTAX FilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A set of parameters for a packet filter applied on a
+ particular interface. As an example, an instance of the
+ filterPktData object might be named filterPktData.12"
+ INDEX { filterIndex }
+ ::= { filterTable 1 }
+
+FilterEntry ::= SEQUENCE {
+ filterIndex Integer32,
+ filterChannelIndex Integer32,
+ filterPktDataOffset Integer32,
+ filterPktData OCTET STRING,
+ filterPktDataMask OCTET STRING,
+ filterPktDataNotMask OCTET STRING,
+ filterPktStatus Integer32,
+ filterPktStatusMask Integer32,
+ filterPktStatusNotMask Integer32,
+ filterOwner OwnerString,
+ filterStatus EntryStatus
+}
+
+filterIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry
+ in the filter table. Each such entry defines
+ one filter that is to be applied to every packet
+ received on an interface."
+ ::= { filterEntry 1 }
+
+filterChannelIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object identifies the channel of which this filter
+ is a part. The filters identified by a particular value
+ of this object are associated with the same channel as
+ identified by the same value of the channelIndex object."
+ ::= { filterEntry 2 }
+
+filterPktDataOffset OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Octets"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The offset from the beginning of each packet where
+ a match of packet data will be attempted. This offset
+ is measured from the point in the physical layer
+ packet after the framing bits, if any. For example,
+ in an Ethernet frame, this point is at the beginning of
+ the destination MAC address.
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ DEFVAL { 0 }
+ ::= { filterEntry 3 }
+
+filterPktData OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The data that is to be matched with the input packet.
+ For each packet received, this filter and the accompanying
+ filterPktDataMask and filterPktDataNotMask will be
+ adjusted for the offset. The only bits relevant to this
+ match algorithm are those that have the corresponding
+ filterPktDataMask bit equal to one. The following three
+ rules are then applied to every packet:
+
+ (1) If the packet is too short and does not have data
+ corresponding to part of the filterPktData, the packet
+ will fail this data match.
+
+ (2) For each relevant bit from the packet with the
+ corresponding filterPktDataNotMask bit set to zero, if
+ the bit from the packet is not equal to the corresponding
+ bit from the filterPktData, then the packet will fail
+ this data match.
+
+ (3) If for every relevant bit from the packet with the
+ corresponding filterPktDataNotMask bit set to one, the
+ bit from the packet is equal to the corresponding bit
+ from the filterPktData, then the packet will fail this
+ data match.
+
+ Any packets that have not failed any of the three matches
+ above have passed this data match. In particular, a zero
+ length filter will match any packet.
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ ::= { filterEntry 4 }
+
+filterPktDataMask OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The mask that is applied to the match process.
+ After adjusting this mask for the offset, only those
+ bits in the received packet that correspond to bits set
+ in this mask are relevant for further processing by the
+
+ match algorithm. The offset is applied to filterPktDataMask
+ in the same way it is applied to the filter. For the
+ purposes of the matching algorithm, if the associated
+ filterPktData object is longer than this mask, this mask is
+ conceptually extended with '1' bits until it reaches the
+ length of the filterPktData object.
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ ::= { filterEntry 5 }
+
+filterPktDataNotMask OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The inversion mask that is applied to the match
+ process. After adjusting this mask for the offset,
+ those relevant bits in the received packet that correspond
+ to bits cleared in this mask must all be equal to their
+ corresponding bits in the filterPktData object for the packet
+ to be accepted. In addition, at least one of those relevant
+ bits in the received packet that correspond to bits set in
+ this mask must be different to its corresponding bit in the
+ filterPktData object.
+
+ For the purposes of the matching algorithm, if the associated
+ filterPktData object is longer than this mask, this mask is
+ conceptually extended with '0' bits until it reaches the
+ length of the filterPktData object.
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ ::= { filterEntry 6 }
+
+filterPktStatus OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status that is to be matched with the input packet.
+ The only bits relevant to this match algorithm are those that
+ have the corresponding filterPktStatusMask bit equal to one.
+ The following two rules are then applied to every packet:
+
+ (1) For each relevant bit from the packet status with the
+ corresponding filterPktStatusNotMask bit set to zero, if
+ the bit from the packet status is not equal to the
+
+ corresponding bit from the filterPktStatus, then the
+ packet will fail this status match.
+
+ (2) If for every relevant bit from the packet status with the
+ corresponding filterPktStatusNotMask bit set to one, the
+ bit from the packet status is equal to the corresponding
+ bit from the filterPktStatus, then the packet will fail
+ this status match.
+
+ Any packets that have not failed either of the two matches
+ above have passed this status match. In particular, a zero
+ length status filter will match any packet's status.
+
+ The value of the packet status is a sum. This sum
+ initially takes the value zero. Then, for each
+ error, E, that has been discovered in this packet,
+ 2 raised to a value representing E is added to the sum.
+ The errors and the bits that represent them are dependent
+ on the media type of the interface that this channel
+ is receiving packets from.
+
+ The errors defined for a packet captured off of an
+ Ethernet interface are as follows:
+
+ bit # Error
+ 0 Packet is longer than 1518 octets
+ 1 Packet is shorter than 64 octets
+ 2 Packet experienced a CRC or Alignment error
+
+ For example, an Ethernet fragment would have a
+ value of 6 (2^1 + 2^2).
+
+ As this MIB is expanded to new media types, this object
+ will have other media-specific errors defined.
+
+ For the purposes of this status matching algorithm, if the
+ packet status is longer than this filterPktStatus object,
+ this object is conceptually extended with '0' bits until it
+ reaches the size of the packet status.
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ ::= { filterEntry 7 }
+
+filterPktStatusMask OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The mask that is applied to the status match process.
+ Only those bits in the received packet that correspond to
+ bits set in this mask are relevant for further processing
+ by the status match algorithm. For the purposes
+ of the matching algorithm, if the associated filterPktStatus
+ object is longer than this mask, this mask is conceptually
+ extended with '1' bits until it reaches the size of the
+ filterPktStatus. In addition, if a packet status is longer
+ than this mask, this mask is conceptually extended with '0'
+ bits until it reaches the size of the packet status.
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ ::= { filterEntry 8 }
+
+filterPktStatusNotMask OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The inversion mask that is applied to the status match
+ process. Those relevant bits in the received packet status
+ that correspond to bits cleared in this mask must all be
+ equal to their corresponding bits in the filterPktStatus
+ object for the packet to be accepted. In addition, at least
+ one of those relevant bits in the received packet status
+ that correspond to bits set in this mask must be different
+ to its corresponding bit in the filterPktStatus object for
+ the packet to be accepted.
+
+ For the purposes of the matching algorithm, if the associated
+ filterPktStatus object or a packet status is longer than this
+ mask, this mask is conceptually extended with '0' bits until
+ it reaches the longer of the lengths of the filterPktStatus
+ object and the packet status.
+
+ This object may not be modified if the associated
+ filterStatus object is equal to valid(1)."
+ ::= { filterEntry 9 }
+
+filterOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it."
+ ::= { filterEntry 10 }
+
+filterStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this filter entry."
+ ::= { filterEntry 11 }
+
+channelTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF ChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of packet channel entries."
+ ::= { filter 2 }
+
+channelEntry OBJECT-TYPE
+ SYNTAX ChannelEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A set of parameters for a packet channel applied on a
+ particular interface. As an example, an instance of the
+ channelMatches object might be named channelMatches.3"
+ INDEX { channelIndex }
+ ::= { channelTable 1 }
+
+ChannelEntry ::= SEQUENCE {
+ channelIndex Integer32,
+ channelIfIndex Integer32,
+ channelAcceptType INTEGER,
+ channelDataControl INTEGER,
+ channelTurnOnEventIndex Integer32,
+ channelTurnOffEventIndex Integer32,
+ channelEventIndex Integer32,
+ channelEventStatus INTEGER,
+ channelMatches Counter32,
+ channelDescription DisplayString,
+ channelOwner OwnerString,
+ channelStatus EntryStatus
+}
+
+channelIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the channel
+ table. Each such entry defines one channel, a logical
+ data and event stream.
+
+ It is suggested that before creating a channel, an
+ application should scan all instances of the
+ filterChannelIndex object to make sure that there are no
+ pre-existing filters that would be inadvertently be linked
+ to the channel."
+ ::= { channelEntry 1 }
+
+channelIfIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The value of this object uniquely identifies the
+ interface on this remote network monitoring device to which
+ the associated filters are applied to allow data into this
+ channel. The interface identified by a particular value
+ of this object is the same interface as identified by the
+ same value of the ifIndex object, defined in RFC 2233 [17].
+
+ The filters in this group are applied to all packets on
+ the local network segment attached to the identified
+ interface.
+
+ An agent may or may not be able to tell if fundamental
+ changes to the media of the interface have occurred and
+ necessitate an invalidation of this entry. For example, a
+ hot-pluggable ethernet card could be pulled out and replaced
+ by a token-ring card. In such a case, if the agent has such
+ knowledge of the change, it is recommended that it
+ invalidate this entry.
+
+ This object may not be modified if the associated
+ channelStatus object is equal to valid(1)."
+ ::= { channelEntry 2 }
+
+channelAcceptType OBJECT-TYPE
+ SYNTAX INTEGER {
+ acceptMatched(1),
+ acceptFailed(2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls the action of the filters
+ associated with this channel. If this object is equal
+ to acceptMatched(1), packets will be accepted to this
+ channel if they are accepted by both the packet data and
+ packet status matches of an associated filter. If
+ this object is equal to acceptFailed(2), packets will
+ be accepted to this channel only if they fail either
+ the packet data match or the packet status match of
+ each of the associated filters.
+
+ In particular, a channel with no associated filters will
+ match no packets if set to acceptMatched(1) case and will
+ match all packets in the acceptFailed(2) case.
+
+ This object may not be modified if the associated
+ channelStatus object is equal to valid(1)."
+ ::= { channelEntry 3 }
+
+channelDataControl OBJECT-TYPE
+ SYNTAX INTEGER {
+ on(1),
+ off(2)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "This object controls the flow of data through this channel.
+ If this object is on(1), data, status and events flow
+ through this channel. If this object is off(2), data,
+ status and events will not flow through this channel."
+ DEFVAL { off }
+ ::= { channelEntry 4 }
+
+channelTurnOnEventIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The value of this object identifies the event
+ that is configured to turn the associated
+ channelDataControl from off to on when the event is
+ generated. The event identified by a particular value
+ of this object is the same event as identified by the
+ same value of the eventIndex object. If there is no
+ corresponding entry in the eventTable, then no
+ association exists. In fact, if no event is intended
+ for this channel, channelTurnOnEventIndex must be
+ set to zero, a non-existent event index.
+
+ This object may not be modified if the associated
+ channelStatus object is equal to valid(1)."
+ ::= { channelEntry 5 }
+
+channelTurnOffEventIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The value of this object identifies the event
+ that is configured to turn the associated
+ channelDataControl from on to off when the event is
+ generated. The event identified by a particular value
+ of this object is the same event as identified by the
+ same value of the eventIndex object. If there is no
+ corresponding entry in the eventTable, then no
+ association exists. In fact, if no event is intended
+ for this channel, channelTurnOffEventIndex must be
+ set to zero, a non-existent event index.
+
+ This object may not be modified if the associated
+ channelStatus object is equal to valid(1)."
+ ::= { channelEntry 6 }
+
+channelEventIndex OBJECT-TYPE
+ SYNTAX Integer32 (0..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The value of this object identifies the event
+ that is configured to be generated when the
+ associated channelDataControl is on and a packet
+ is matched. The event identified by a particular value
+ of this object is the same event as identified by the
+ same value of the eventIndex object. If there is no
+ corresponding entry in the eventTable, then no
+ association exists. In fact, if no event is intended
+ for this channel, channelEventIndex must be
+ set to zero, a non-existent event index.
+
+ This object may not be modified if the associated
+ channelStatus object is equal to valid(1)."
+ ::= { channelEntry 7 }
+
+channelEventStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ eventReady(1),
+ eventFired(2),
+ eventAlwaysReady(3)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The event status of this channel.
+
+ If this channel is configured to generate events
+ when packets are matched, a means of controlling
+ the flow of those events is often needed. When
+ this object is equal to eventReady(1), a single
+ event may be generated, after which this object
+ will be set by the probe to eventFired(2). While
+ in the eventFired(2) state, no events will be
+ generated until the object is modified to
+ eventReady(1) (or eventAlwaysReady(3)). The
+ management station can thus easily respond to a
+ notification of an event by re-enabling this object.
+
+ If the management station wishes to disable this
+ flow control and allow events to be generated
+ at will, this object may be set to
+ eventAlwaysReady(3). Disabling the flow control
+ is discouraged as it can result in high network
+ traffic or other performance problems."
+ DEFVAL { eventReady }
+ ::= { channelEntry 8 }
+
+channelMatches OBJECT-TYPE
+ SYNTAX Counter32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of times this channel has matched a packet.
+ Note that this object is updated even when
+ channelDataControl is set to off."
+ ::= { channelEntry 9 }
+
+channelDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..127))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "A comment describing this channel."
+ ::= { channelEntry 10 }
+
+channelOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it."
+ ::= { channelEntry 11 }
+
+channelStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this channel entry."
+ ::= { channelEntry 12 }
+
+-- The Packet Capture Group
+
+-- Implementation of the Packet Capture group is optional. The Packet
+-- Capture Group requires implementation of the Filter Group.
+-- Consult the MODULE-COMPLIANCE macro for the authoritative
+-- conformance information for this MIB.
+--
+-- The Packet Capture group allows packets to be captured
+-- upon a filter match. The bufferControlTable controls
+-- the captured packets output from a channel that is
+-- associated with it. The captured packets are placed
+-- in entries in the captureBufferTable. These entries are
+-- associated with the bufferControlEntry on whose behalf they
+-- were stored.
+
+bufferControlTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BufferControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of buffers control entries."
+ ::= { capture 1 }
+
+bufferControlEntry OBJECT-TYPE
+ SYNTAX BufferControlEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A set of parameters that control the collection of a stream
+ of packets that have matched filters. As an example, an
+ instance of the bufferControlCaptureSliceSize object might
+ be named bufferControlCaptureSliceSize.3"
+ INDEX { bufferControlIndex }
+ ::= { bufferControlTable 1 }
+
+BufferControlEntry ::= SEQUENCE {
+ bufferControlIndex Integer32,
+ bufferControlChannelIndex Integer32,
+ bufferControlFullStatus INTEGER,
+ bufferControlFullAction INTEGER,
+ bufferControlCaptureSliceSize Integer32,
+ bufferControlDownloadSliceSize Integer32,
+ bufferControlDownloadOffset Integer32,
+ bufferControlMaxOctetsRequested Integer32,
+ bufferControlMaxOctetsGranted Integer32,
+ bufferControlCapturedPackets Integer32,
+ bufferControlTurnOnTime TimeTicks,
+ bufferControlOwner OwnerString,
+ bufferControlStatus EntryStatus
+}
+
+bufferControlIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry
+ in the bufferControl table. The value of this
+ index shall never be zero. Each such
+ entry defines one set of packets that is
+ captured and controlled by one or more filters."
+ ::= { bufferControlEntry 1 }
+
+bufferControlChannelIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "An index that identifies the channel that is the
+ source of packets for this bufferControl table.
+ The channel identified by a particular value of this
+ index is the same as identified by the same value of
+ the channelIndex object.
+
+ This object may not be modified if the associated
+ bufferControlStatus object is equal to valid(1)."
+ ::= { bufferControlEntry 2 }
+
+bufferControlFullStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+
+ spaceAvailable(1),
+ full(2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "This object shows whether the buffer has room to
+ accept new packets or if it is full.
+
+ If the status is spaceAvailable(1), the buffer is
+ accepting new packets normally. If the status is
+ full(2) and the associated bufferControlFullAction
+ object is wrapWhenFull, the buffer is accepting new
+ packets by deleting enough of the oldest packets
+ to make room for new ones as they arrive. Otherwise,
+ if the status is full(2) and the
+ bufferControlFullAction object is lockWhenFull,
+ then the buffer has stopped collecting packets.
+
+ When this object is set to full(2) the probe must
+ not later set it to spaceAvailable(1) except in the
+ case of a significant gain in resources such as
+ an increase of bufferControlOctetsGranted. In
+ particular, the wrap-mode action of deleting old
+ packets to make room for newly arrived packets
+ must not affect the value of this object."
+ ::= { bufferControlEntry 3 }
+
+bufferControlFullAction OBJECT-TYPE
+ SYNTAX INTEGER {
+ lockWhenFull(1),
+ wrapWhenFull(2) -- FIFO
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "Controls the action of the buffer when it
+ reaches the full status. When in the lockWhenFull(1)
+ state and a packet is added to the buffer that
+ fills the buffer, the bufferControlFullStatus will
+ be set to full(2) and this buffer will stop capturing
+ packets."
+ ::= { bufferControlEntry 4 }
+
+bufferControlCaptureSliceSize OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Octets"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The maximum number of octets of each packet
+ that will be saved in this capture buffer.
+ For example, if a 1500 octet packet is received by
+ the probe and this object is set to 500, then only
+ 500 octets of the packet will be stored in the
+ associated capture buffer. If this variable is set
+ to 0, the capture buffer will save as many octets
+ as is possible.
+
+ This object may not be modified if the associated
+ bufferControlStatus object is equal to valid(1)."
+ DEFVAL { 100 }
+ ::= { bufferControlEntry 5 }
+
+bufferControlDownloadSliceSize OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Octets"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The maximum number of octets of each packet
+ in this capture buffer that will be returned in
+ an SNMP retrieval of that packet. For example,
+ if 500 octets of a packet have been stored in the
+ associated capture buffer, the associated
+ bufferControlDownloadOffset is 0, and this
+ object is set to 100, then the captureBufferPacket
+ object that contains the packet will contain only
+ the first 100 octets of the packet.
+
+ A prudent manager will take into account possible
+ interoperability or fragmentation problems that may
+ occur if the download slice size is set too large.
+ In particular, conformant SNMP implementations are not
+ required to accept messages whose length exceeds 484
+ octets, although they are encouraged to support larger
+ datagrams whenever feasible."
+ DEFVAL { 100 }
+ ::= { bufferControlEntry 6 }
+
+bufferControlDownloadOffset OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Octets"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The offset of the first octet of each packet
+ in this capture buffer that will be returned in
+ an SNMP retrieval of that packet. For example,
+ if 500 octets of a packet have been stored in the
+ associated capture buffer and this object is set to
+ 100, then the captureBufferPacket object that
+ contains the packet will contain bytes starting
+ 100 octets into the packet."
+ DEFVAL { 0 }
+ ::= { bufferControlEntry 7 }
+
+bufferControlMaxOctetsRequested OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Octets"
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The requested maximum number of octets to be
+ saved in this captureBuffer, including any
+ implementation-specific overhead. If this variable
+ is set to -1, the capture buffer will save as many
+ octets as is possible.
+
+ When this object is created or modified, the probe
+ should set bufferControlMaxOctetsGranted as closely
+ to this object as is possible for the particular probe
+ implementation and available resources. However, if
+ the object has the special value of -1, the probe
+ must set bufferControlMaxOctetsGranted to -1."
+ DEFVAL { -1 }
+ ::= { bufferControlEntry 8 }
+
+bufferControlMaxOctetsGranted OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The maximum number of octets that can be
+ saved in this captureBuffer, including overhead.
+ If this variable is -1, the capture buffer will save
+ as many octets as possible.
+
+ When the bufferControlMaxOctetsRequested object is
+ created or modified, the probe should set this object
+ as closely to the requested value as is possible for the
+ particular probe implementation and available resources.
+ However, if the request object has the special value
+
+ of -1, the probe must set this object to -1.
+
+ The probe must not lower this value except as a result of
+ a modification to the associated
+ bufferControlMaxOctetsRequested object.
+
+ When this maximum number of octets is reached
+ and a new packet is to be added to this
+ capture buffer and the corresponding
+ bufferControlFullAction is set to wrapWhenFull(2),
+ enough of the oldest packets associated with this
+ capture buffer shall be deleted by the agent so
+ that the new packet can be added. If the corresponding
+ bufferControlFullAction is set to lockWhenFull(1),
+ the new packet shall be discarded. In either case,
+ the probe must set bufferControlFullStatus to
+ full(2).
+
+ When the value of this object changes to a value less
+ than the current value, entries are deleted from
+ the captureBufferTable associated with this
+ bufferControlEntry. Enough of the
+ oldest of these captureBufferEntries shall be
+ deleted by the agent so that the number of octets
+ used remains less than or equal to the new value of
+ this object.
+
+ When the value of this object changes to a value greater
+ than the current value, the number of associated
+ captureBufferEntries may be allowed to grow."
+ ::= { bufferControlEntry 9 }
+
+bufferControlCapturedPackets OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Packets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of packets currently in this captureBuffer."
+ ::= { bufferControlEntry 10 }
+
+bufferControlTurnOnTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when this capture buffer was
+ first turned on."
+ ::= { bufferControlEntry 11 }
+
+bufferControlOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it."
+ ::= { bufferControlEntry 12 }
+
+bufferControlStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this buffer Control Entry."
+ ::= { bufferControlEntry 13 }
+
+captureBufferTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF CaptureBufferEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of packets captured off of a channel."
+ ::= { capture 2 }
+
+captureBufferEntry OBJECT-TYPE
+ SYNTAX CaptureBufferEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A packet captured off of an attached network. As an
+ example, an instance of the captureBufferPacketData
+ object might be named captureBufferPacketData.3.1783"
+ INDEX { captureBufferControlIndex, captureBufferIndex }
+ ::= { captureBufferTable 1 }
+
+CaptureBufferEntry ::= SEQUENCE {
+ captureBufferControlIndex Integer32,
+ captureBufferIndex Integer32,
+ captureBufferPacketID Integer32,
+ captureBufferPacketData OCTET STRING,
+ captureBufferPacketLength Integer32,
+ captureBufferPacketTime Integer32,
+ captureBufferPacketStatus Integer32
+}
+
+captureBufferControlIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The index of the bufferControlEntry with which
+ this packet is associated."
+ ::= { captureBufferEntry 1 }
+
+captureBufferIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry
+ in the captureBuffer table associated with a
+ particular bufferControlEntry. This index will
+ start at 1 and increase by one for each new packet
+ added with the same captureBufferControlIndex.
+
+ Should this value reach 2147483647, the next packet
+ added with the same captureBufferControlIndex shall
+ cause this value to wrap around to 1."
+ ::= { captureBufferEntry 2 }
+
+captureBufferPacketID OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that describes the order of packets
+ that are received on a particular interface.
+ The packetID of a packet captured on an
+ interface is defined to be greater than the
+ packetID's of all packets captured previously on
+ the same interface. As the captureBufferPacketID
+ object has a maximum positive value of 2^31 - 1,
+ any captureBufferPacketID object shall have the
+ value of the associated packet's packetID mod 2^31."
+ ::= { captureBufferEntry 3 }
+
+captureBufferPacketData OBJECT-TYPE
+ SYNTAX OCTET STRING
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The data inside the packet, starting at the beginning
+ of the packet plus any offset specified in the
+
+ associated bufferControlDownloadOffset, including any
+ link level headers. The length of the data in this object
+ is the minimum of the length of the captured packet minus
+ the offset, the length of the associated
+ bufferControlCaptureSliceSize minus the offset, and the
+ associated bufferControlDownloadSliceSize. If this minimum
+ is less than zero, this object shall have a length of zero."
+ ::= { captureBufferEntry 4 }
+
+captureBufferPacketLength OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Octets"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The actual length (off the wire) of the packet stored
+ in this entry, including FCS octets."
+ ::= { captureBufferEntry 5 }
+
+captureBufferPacketTime OBJECT-TYPE
+ SYNTAX Integer32
+ UNITS "Milliseconds"
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The number of milliseconds that had passed since
+ this capture buffer was first turned on when this
+ packet was captured."
+ ::= { captureBufferEntry 6 }
+
+captureBufferPacketStatus OBJECT-TYPE
+ SYNTAX Integer32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "A value which indicates the error status of this packet.
+
+ The value of this object is defined in the same way as
+ filterPktStatus. The value is a sum. This sum
+ initially takes the value zero. Then, for each
+ error, E, that has been discovered in this packet,
+ 2 raised to a value representing E is added to the sum.
+
+ The errors defined for a packet captured off of an
+ Ethernet interface are as follows:
+
+ bit # Error
+ 0 Packet is longer than 1518 octets
+
+ 1 Packet is shorter than 64 octets
+ 2 Packet experienced a CRC or Alignment error
+ 3 First packet in this capture buffer after
+ it was detected that some packets were
+ not processed correctly.
+ 4 Packet's order in buffer is only approximate
+ (May only be set for packets sent from
+ the probe)
+
+ For example, an Ethernet fragment would have a
+ value of 6 (2^1 + 2^2).
+
+ As this MIB is expanded to new media types, this object
+ will have other media-specific errors defined."
+ ::= { captureBufferEntry 7 }
+
+-- The Event Group
+
+-- Implementation of the Event group is optional.
+-- Consult the MODULE-COMPLIANCE macro for the authoritative
+-- conformance information for this MIB.
+--
+-- The Event group controls the generation and notification
+-- of events from this device. Each entry in the eventTable
+-- describes the parameters of the event that can be triggered.
+-- Each event entry is fired by an associated condition located
+-- elsewhere in the MIB. An event entry may also be associated
+-- with a function elsewhere in the MIB that will be executed
+-- when the event is generated. For example, a channel may
+-- be turned on or off by the firing of an event.
+--
+-- Each eventEntry may optionally specify that a log entry
+-- be created on its behalf whenever the event occurs.
+-- Each entry may also specify that notification should
+-- occur by way of SNMP trap messages. In this case, the
+-- community for the trap message is given in the associated
+-- eventCommunity object. The enterprise and specific trap
+-- fields of the trap are determined by the condition that
+-- triggered the event. Two traps are defined: risingAlarm and
+-- fallingAlarm. If the eventTable is triggered by a condition
+-- specified elsewhere, the enterprise and specific trap fields
+-- must be specified for traps generated for that condition.
+
+eventTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF EventEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of events to be generated."
+ ::= { event 1 }
+
+eventEntry OBJECT-TYPE
+ SYNTAX EventEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A set of parameters that describe an event to be generated
+ when certain conditions are met. As an example, an instance
+ of the eventLastTimeSent object might be named
+ eventLastTimeSent.6"
+ INDEX { eventIndex }
+ ::= { eventTable 1 }
+
+EventEntry ::= SEQUENCE {
+ eventIndex Integer32,
+ eventDescription DisplayString,
+ eventType INTEGER,
+ eventCommunity OCTET STRING,
+ eventLastTimeSent TimeTicks,
+ eventOwner OwnerString,
+ eventStatus EntryStatus
+}
+
+eventIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry in the
+ event table. Each such entry defines one event that
+ is to be generated when the appropriate conditions
+ occur."
+ ::= { eventEntry 1 }
+
+eventDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..127))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "A comment describing this event entry."
+ ::= { eventEntry 2 }
+
+eventType OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1),
+ log(2),
+ snmptrap(3), -- send an SNMP trap
+ logandtrap(4)
+ }
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The type of notification that the probe will make
+ about this event. In the case of log, an entry is
+ made in the log table for each event. In the case of
+ snmp-trap, an SNMP trap is sent to one or more
+ management stations."
+ ::= { eventEntry 3 }
+
+eventCommunity OBJECT-TYPE
+ SYNTAX OCTET STRING (SIZE (0..127))
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "If an SNMP trap is to be sent, it will be sent to
+ the SNMP community specified by this octet string."
+ ::= { eventEntry 4 }
+
+eventLastTimeSent OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime at the time this event
+ entry last generated an event. If this entry has
+ not generated any events, this value will be
+ zero."
+ ::= { eventEntry 5 }
+
+eventOwner OBJECT-TYPE
+ SYNTAX OwnerString
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The entity that configured this entry and is therefore
+ using the resources assigned to it.
+
+ If this object contains a string starting with 'monitor'
+ and has associated entries in the log table, all connected
+ management stations should retrieve those log entries,
+ as they may have significance to all management stations
+ connected to this device"
+ ::= { eventEntry 6 }
+
+eventStatus OBJECT-TYPE
+ SYNTAX EntryStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this event entry.
+
+ If this object is not equal to valid(1), all associated
+ log entries shall be deleted by the agent."
+ ::= { eventEntry 7 }
+
+--
+logTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF LogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A list of events that have been logged."
+ ::= { event 2 }
+
+logEntry OBJECT-TYPE
+ SYNTAX LogEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A set of data describing an event that has been
+ logged. For example, an instance of the logDescription
+ object might be named logDescription.6.47"
+ INDEX { logEventIndex, logIndex }
+ ::= { logTable 1 }
+
+LogEntry ::= SEQUENCE {
+ logEventIndex Integer32,
+ logIndex Integer32,
+ logTime TimeTicks,
+ logDescription DisplayString
+}
+
+logEventIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The event entry that generated this log
+ entry. The log identified by a particular
+ value of this index is associated with the same
+ eventEntry as identified by the same value
+ of eventIndex."
+ ::= { logEntry 1 }
+
+logIndex OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An index that uniquely identifies an entry
+ in the log table amongst those generated by the
+ same eventEntries. These indexes are
+ assigned beginning with 1 and increase by one
+ with each new log entry. The association
+ between values of logIndex and logEntries
+ is fixed for the lifetime of each logEntry.
+ The agent may choose to delete the oldest
+ instances of logEntry as required because of
+ lack of memory. It is an implementation-specific
+ matter as to when this deletion may occur."
+ ::= { logEntry 2 }
+
+logTime OBJECT-TYPE
+ SYNTAX TimeTicks
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The value of sysUpTime when this log entry was created."
+ ::= { logEntry 3 }
+
+logDescription OBJECT-TYPE
+ SYNTAX DisplayString (SIZE (0..255))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "An implementation dependent description of the
+ event that activated this log entry."
+ ::= { logEntry 4 }
+
+-- Remote Network Monitoring Traps
+
+rmonEventsV2 OBJECT-IDENTITY
+ STATUS current
+ DESCRIPTION "Definition point for RMON notifications."
+ ::= { rmon 0 }
+
+risingAlarm NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmVariable, alarmSampleType,
+ alarmValue, alarmRisingThreshold }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm
+ entry crosses its rising threshold and generates
+ an event that is configured for sending SNMP
+ traps."
+ ::= { rmonEventsV2 1 }
+
+fallingAlarm NOTIFICATION-TYPE
+ OBJECTS { alarmIndex, alarmVariable, alarmSampleType,
+ alarmValue, alarmFallingThreshold }
+ STATUS current
+ DESCRIPTION
+ "The SNMP trap that is generated when an alarm
+ entry crosses its falling threshold and generates
+ an event that is configured for sending SNMP
+ traps."
+ ::= { rmonEventsV2 2 }
+
+-- Conformance information
+
+rmonCompliances OBJECT IDENTIFIER ::= { rmonConformance 9 }
+rmonGroups OBJECT IDENTIFIER ::= { rmonConformance 10 }
+
+-- Compliance Statements
+rmonCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The requirements for conformance to the RMON MIB. At least
+ one of the groups in this module must be implemented to
+ conform to the RMON MIB. Implementations of this MIB
+ must also implement the system group of MIB-II [16] and the
+ IF-MIB [17]."
+ MODULE -- this module
+
+ GROUP rmonEtherStatsGroup
+ DESCRIPTION
+ "The RMON Ethernet Statistics Group is optional."
+
+ GROUP rmonHistoryControlGroup
+ DESCRIPTION
+ "The RMON History Control Group is optional."
+
+ GROUP rmonEthernetHistoryGroup
+ DESCRIPTION
+ "The RMON Ethernet History Group is optional."
+
+ GROUP rmonAlarmGroup
+ DESCRIPTION
+ "The RMON Alarm Group is optional."
+
+ GROUP rmonHostGroup
+ DESCRIPTION
+ "The RMON Host Group is mandatory when the
+ rmonHostTopNGroup is implemented."
+
+ GROUP rmonHostTopNGroup
+ DESCRIPTION
+ "The RMON Host Top N Group is optional."
+
+ GROUP rmonMatrixGroup
+ DESCRIPTION
+ "The RMON Matrix Group is optional."
+
+ GROUP rmonFilterGroup
+ DESCRIPTION
+ "The RMON Filter Group is mandatory when the
+ rmonPacketCaptureGroup is implemented."
+
+ GROUP rmonPacketCaptureGroup
+ DESCRIPTION
+ "The RMON Packet Capture Group is optional."
+
+ GROUP rmonEventGroup
+ DESCRIPTION
+ "The RMON Event Group is mandatory when the
+ rmonAlarmGroup is implemented."
+ ::= { rmonCompliances 1 }
+
+ rmonEtherStatsGroup OBJECT-GROUP
+ OBJECTS {
+ etherStatsIndex, etherStatsDataSource,
+ etherStatsDropEvents, etherStatsOctets, etherStatsPkts,
+ etherStatsBroadcastPkts, etherStatsMulticastPkts,
+ etherStatsCRCAlignErrors, etherStatsUndersizePkts,
+ etherStatsOversizePkts, etherStatsFragments,
+ etherStatsJabbers, etherStatsCollisions,
+ etherStatsPkts64Octets, etherStatsPkts65to127Octets,
+ etherStatsPkts128to255Octets,
+ etherStatsPkts256to511Octets,
+ etherStatsPkts512to1023Octets,
+ etherStatsPkts1024to1518Octets,
+ etherStatsOwner, etherStatsStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "The RMON Ethernet Statistics Group."
+ ::= { rmonGroups 1 }
+
+ rmonHistoryControlGroup OBJECT-GROUP
+ OBJECTS {
+ historyControlIndex, historyControlDataSource,
+ historyControlBucketsRequested,
+ historyControlBucketsGranted, historyControlInterval,
+ historyControlOwner, historyControlStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "The RMON History Control Group."
+ ::= { rmonGroups 2 }
+
+ rmonEthernetHistoryGroup OBJECT-GROUP
+ OBJECTS {
+ etherHistoryIndex, etherHistorySampleIndex,
+ etherHistoryIntervalStart, etherHistoryDropEvents,
+ etherHistoryOctets, etherHistoryPkts,
+ etherHistoryBroadcastPkts, etherHistoryMulticastPkts,
+ etherHistoryCRCAlignErrors, etherHistoryUndersizePkts,
+ etherHistoryOversizePkts, etherHistoryFragments,
+ etherHistoryJabbers, etherHistoryCollisions,
+ etherHistoryUtilization
+ }
+ STATUS current
+ DESCRIPTION
+ "The RMON Ethernet History Group."
+ ::= { rmonGroups 3 }
+
+ rmonAlarmGroup OBJECT-GROUP
+ OBJECTS {
+ alarmIndex, alarmInterval, alarmVariable,
+ alarmSampleType, alarmValue, alarmStartupAlarm,
+ alarmRisingThreshold, alarmFallingThreshold,
+ alarmRisingEventIndex, alarmFallingEventIndex,
+ alarmOwner, alarmStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "The RMON Alarm Group."
+ ::= { rmonGroups 4 }
+
+ rmonHostGroup OBJECT-GROUP
+ OBJECTS {
+ hostControlIndex, hostControlDataSource,
+ hostControlTableSize, hostControlLastDeleteTime,
+ hostControlOwner, hostControlStatus,
+ hostAddress, hostCreationOrder, hostIndex,
+ hostInPkts, hostOutPkts, hostInOctets,
+ hostOutOctets, hostOutErrors, hostOutBroadcastPkts,
+ hostOutMulticastPkts, hostTimeAddress,
+ hostTimeCreationOrder, hostTimeIndex,
+ hostTimeInPkts, hostTimeOutPkts, hostTimeInOctets,
+ hostTimeOutOctets, hostTimeOutErrors,
+ hostTimeOutBroadcastPkts, hostTimeOutMulticastPkts
+ }
+ STATUS current
+ DESCRIPTION
+ "The RMON Host Group."
+ ::= { rmonGroups 5 }
+
+ rmonHostTopNGroup OBJECT-GROUP
+ OBJECTS {
+ hostTopNControlIndex, hostTopNHostIndex,
+ hostTopNRateBase, hostTopNTimeRemaining,
+ hostTopNDuration, hostTopNRequestedSize,
+ hostTopNGrantedSize, hostTopNStartTime,
+ hostTopNOwner, hostTopNStatus,
+ hostTopNReport, hostTopNIndex,
+ hostTopNAddress, hostTopNRate
+ }
+ STATUS current
+ DESCRIPTION
+ "The RMON Host Top 'N' Group."
+ ::= { rmonGroups 6 }
+
+ rmonMatrixGroup OBJECT-GROUP
+ OBJECTS {
+ matrixControlIndex, matrixControlDataSource,
+ matrixControlTableSize, matrixControlLastDeleteTime,
+ matrixControlOwner, matrixControlStatus,
+ matrixSDSourceAddress, matrixSDDestAddress,
+ matrixSDIndex, matrixSDPkts,
+ matrixSDOctets, matrixSDErrors,
+ matrixDSSourceAddress, matrixDSDestAddress,
+ matrixDSIndex, matrixDSPkts,
+ matrixDSOctets, matrixDSErrors
+ }
+ STATUS current
+ DESCRIPTION
+ "The RMON Matrix Group."
+ ::= { rmonGroups 7 }
+
+ rmonFilterGroup OBJECT-GROUP
+ OBJECTS {
+
+ filterIndex, filterChannelIndex, filterPktDataOffset,
+ filterPktData, filterPktDataMask,
+ filterPktDataNotMask, filterPktStatus,
+ filterPktStatusMask, filterPktStatusNotMask,
+ filterOwner, filterStatus,
+ channelIndex, channelIfIndex, channelAcceptType,
+ channelDataControl, channelTurnOnEventIndex,
+ channelTurnOffEventIndex, channelEventIndex,
+ channelEventStatus, channelMatches,
+ channelDescription, channelOwner, channelStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "The RMON Filter Group."
+ ::= { rmonGroups 8 }
+
+ rmonPacketCaptureGroup OBJECT-GROUP
+ OBJECTS {
+ bufferControlIndex, bufferControlChannelIndex,
+ bufferControlFullStatus, bufferControlFullAction,
+ bufferControlCaptureSliceSize,
+ bufferControlDownloadSliceSize,
+ bufferControlDownloadOffset,
+ bufferControlMaxOctetsRequested,
+ bufferControlMaxOctetsGranted,
+ bufferControlCapturedPackets,
+ bufferControlTurnOnTime,
+ bufferControlOwner, bufferControlStatus,
+ captureBufferControlIndex, captureBufferIndex,
+ captureBufferPacketID, captureBufferPacketData,
+ captureBufferPacketLength, captureBufferPacketTime,
+ captureBufferPacketStatus
+ }
+ STATUS current
+ DESCRIPTION
+ "The RMON Packet Capture Group."
+ ::= { rmonGroups 9 }
+
+ rmonEventGroup OBJECT-GROUP
+ OBJECTS {
+ eventIndex, eventDescription, eventType,
+ eventCommunity, eventLastTimeSent,
+ eventOwner, eventStatus,
+ logEventIndex, logIndex, logTime,
+ logDescription
+ }
+ STATUS current
+ DESCRIPTION
+ "The RMON Event Group."
+ ::= { rmonGroups 10 }
+
+ rmonNotificationGroup NOTIFICATION-GROUP
+ NOTIFICATIONS { risingAlarm, fallingAlarm }
+ STATUS current
+ DESCRIPTION
+ "The RMON Notification Group."
+ ::= { rmonGroups 11 }
+END