diff --git a/usr/src/cmd/fm/dicts/SUN4.po b/usr/src/cmd/fm/dicts/SUN4.po
deleted file mode 100644
index b1df0f35b1..0000000000
--- a/usr/src/cmd/fm/dicts/SUN4.po
+++ /dev/null
@@ -1,345 +0,0 @@
-#
-# Copyright 2007 Sun Microsystems, Inc. All rights reserved.
-# Use is subject to license terms.
-#
-# CDDL HEADER START
-#
-# The contents of this file are subject to the terms of the
-# Common Development and Distribution License (the "License").
-# You may not use this file except in compliance with the License.
-#
-# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
-# or http://www.opensolaris.org/os/licensing.
-# See the License for the specific language governing permissions
-# and limitations under the License.
-#
-# When distributing Covered Code, include this CDDL HEADER in each
-# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
-# If applicable, add the following below this CDDL HEADER, with the
-# fields enclosed by brackets "[]" replaced with your own identifying
-# information: Portions Copyright [yyyy] [name of copyright owner]
-#
-# CDDL HEADER END
-#
-# DO NOT EDIT -- this file is generated by the Event Registry.
-#
-#
-# code: SUN4-8000-0Y
-# keys: fault.io.fire.asic
-#
-msgid "SUN4-8000-0Y.type"
-msgstr "Fault"
-msgid "SUN4-8000-0Y.severity"
-msgstr "Critical"
-msgid "SUN4-8000-0Y.description"
-msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information."
-msgid "SUN4-8000-0Y.response"
-msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
-msgid "SUN4-8000-0Y.impact"
-msgstr "Loss of services provided by the device instances associated with this fault"
-msgid "SUN4-8000-0Y.action"
-msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
-#
-# code: SUN4-8000-13
-# keys: fault.io.ebus
-#
-msgid "SUN4-8000-13.type"
-msgstr "Fault"
-msgid "SUN4-8000-13.severity"
-msgstr "Critical"
-msgid "SUN4-8000-13.description"
-msgstr "A problem was detected in the Ebus. Refer to %s for more information."
-msgid "SUN4-8000-13.response"
-msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
-msgid "SUN4-8000-13.impact"
-msgstr "Loss of services provided by the device instances associated with this fault"
-msgid "SUN4-8000-13.action"
-msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u \nEVENT_ID to collect information to help illumos personnel \nidentify the device in need of repair. Schedule a repair procedure to replace \nthe affected device.\n"
-#
-# code: SUN4-8000-2H
-# keys: fault.io.datapath
-#
-msgid "SUN4-8000-2H.type"
-msgstr "Fault"
-msgid "SUN4-8000-2H.severity"
-msgstr "Critical"
-msgid "SUN4-8000-2H.description"
-msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details. Refer to %s for more information."
-msgid "SUN4-8000-2H.response"
-msgstr "None"
-msgid "SUN4-8000-2H.impact"
-msgstr "None"
-msgid "SUN4-8000-2H.action"
-msgstr "None"
-#
-# code: SUN4-8000-3D
-# keys: fault.io.hbus
-#
-msgid "SUN4-8000-3D.type"
-msgstr "Fault"
-msgid "SUN4-8000-3D.severity"
-msgstr "Critical"
-msgid "SUN4-8000-3D.description"
-msgstr "A problem was detected in a system core bus.\n Refer to %s for more information."
-msgid "SUN4-8000-3D.response"
-msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
-msgid "SUN4-8000-3D.impact"
-msgstr "Loss of services provided by the device instances associated with this fault"
-msgid "SUN4-8000-3D.action"
-msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp illumos personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
-#
-# code: SUN4-8000-4P
-# keys: fault.io.fire.pciex.device
-#
-msgid "SUN4-8000-4P.type"
-msgstr "Fault"
-msgid "SUN4-8000-4P.severity"
-msgstr "Critical"
-msgid "SUN4-8000-4P.description"
-msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information."
-msgid "SUN4-8000-4P.response"
-msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
-msgid "SUN4-8000-4P.impact"
-msgstr "Loss of services provided by the device instances associated with this fault"
-msgid "SUN4-8000-4P.action"
-msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. \nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below."
-#
-# code: SUN4-8000-5A
-# keys: defect.io.fire.pciex.driver
-#
-msgid "SUN4-8000-5A.type"
-msgstr "Defect"
-msgid "SUN4-8000-5A.severity"
-msgstr "Critical"
-msgid "SUN4-8000-5A.description"
-msgstr "A problem was detected in the PCI-Express subsystem software.\n Refer to %s for more information."
-msgid "SUN4-8000-5A.response"
-msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
-msgid "SUN4-8000-5A.impact"
-msgstr "Loss of services provided by the device instances associated with\nthis problem"
-msgid "SUN4-8000-5A.action"
-msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
-#
-# code: SUN4-8000-6S
-# keys: fault.io.datapath fault.io.fire.asic
-#
-msgid "SUN4-8000-6S.type"
-msgstr "Fault"
-msgid "SUN4-8000-6S.severity"
-msgstr "Critical"
-msgid "SUN4-8000-6S.description"
-msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details. Refer to %s for more information."
-msgid "SUN4-8000-6S.response"
-msgstr "None"
-msgid "SUN4-8000-6S.impact"
-msgstr "None"
-msgid "SUN4-8000-6S.action"
-msgstr "None"
-#
-# code: SUN4-8000-75
-# keys: fault.io.fire.asic fault.io.fire.pciex.device
-#
-msgid "SUN4-8000-75.type"
-msgstr "Fault"
-msgid "SUN4-8000-75.severity"
-msgstr "Critical"
-msgid "SUN4-8000-75.description"
-msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information."
-msgid "SUN4-8000-75.response"
-msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
-msgid "SUN4-8000-75.impact"
-msgstr "Loss of services provided by the device instances associated with this fault"
-msgid "SUN4-8000-75.action"
-msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
-#
-# code: SUN4-8000-8E
-# keys: defect.io.fire.pci.driver defect.io.fire.pciex.driver
-#
-msgid "SUN4-8000-8E.type"
-msgstr "Defect"
-msgid "SUN4-8000-8E.severity"
-msgstr "Critical"
-msgid "SUN4-8000-8E.description"
-msgstr "A problem was detected in the PCI-Express subsystem software. Refer to %s for more information."
-msgid "SUN4-8000-8E.response"
-msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
-msgid "SUN4-8000-8E.impact"
-msgstr "Loss of services provided by the device instances associated with this problem"
-msgid "SUN4-8000-8E.action"
-msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support."
-#
-# code: SUN4-8000-9J
-# keys: fault.io.fire.pci.device fault.io.fire.pciex.device
-#
-msgid "SUN4-8000-9J.type"
-msgstr "Fault"
-msgid "SUN4-8000-9J.severity"
-msgstr "Critical"
-msgid "SUN4-8000-9J.description"
-msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details. Refer to %s for more information."
-msgid "SUN4-8000-9J.response"
-msgstr "None"
-msgid "SUN4-8000-9J.impact"
-msgstr "None"
-msgid "SUN4-8000-9J.action"
-msgstr "None"
-#
-# code: SUN4-8000-A2
-# keys: fault.io.fire.pci.device
-#
-msgid "SUN4-8000-A2.type"
-msgstr "Fault"
-msgid "SUN4-8000-A2.severity"
-msgstr "Critical"
-msgid "SUN4-8000-A2.description"
-msgstr "A problem was detected in the PCI subsystem.\n Refer to %s for more information."
-msgid "SUN4-8000-A2.response"
-msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
-msgid "SUN4-8000-A2.impact"
-msgstr "Loss of services provided by the device instances associated with this fault"
-msgid "SUN4-8000-A2.action"
-msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n"
-#
-# code: SUN4-8000-CX
-# keys: defect.io.fire.pciex.driver fault.io.datapath fault.io.fire.asic
-#
-msgid "SUN4-8000-CX.type"
-msgstr "Fault"
-msgid "SUN4-8000-CX.severity"
-msgstr "Critical"
-msgid "SUN4-8000-CX.description"
-msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details. Refer to %s for more information."
-msgid "SUN4-8000-CX.response"
-msgstr "None"
-msgid "SUN4-8000-CX.impact"
-msgstr "None"
-msgid "SUN4-8000-CX.action"
-msgstr "None"
-#
-# code: SUN4-8000-D4
-# keys: fault.io.fire.asic fault.io.fire.pci.device fault.io.fire.pciex.device
-#
-msgid "SUN4-8000-D4.type"
-msgstr "Fault"
-msgid "SUN4-8000-D4.severity"
-msgstr "Critical"
-msgid "SUN4-8000-D4.description"
-msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information."
-msgid "SUN4-8000-D4.response"
-msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
-msgid "SUN4-8000-D4.impact"
-msgstr "Loss of services provided by the device instances associated with this fault"
-msgid "SUN4-8000-D4.action"
-msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
-#
-# code: SUN4-8000-ER
-# keys: fault.io.fire.asic fault.io.fire.pci.device
-#
-msgid "SUN4-8000-ER.type"
-msgstr "Fault"
-msgid "SUN4-8000-ER.severity"
-msgstr "Critical"
-msgid "SUN4-8000-ER.description"
-msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information."
-msgid "SUN4-8000-ER.response"
-msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
-msgid "SUN4-8000-ER.impact"
-msgstr "Loss of services provided by the device instances associated with this fault"
-msgid "SUN4-8000-ER.action"
-msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n"
-#
-# code: SUN4-8000-FC
-# keys: fault.io.fire.hbus
-#
-msgid "SUN4-8000-FC.type"
-msgstr "Fault"
-msgid "SUN4-8000-FC.severity"
-msgstr "Major"
-msgid "SUN4-8000-FC.description"
-msgstr "A problem was detected in a system core bus.\n Refer to %s for more information."
-msgid "SUN4-8000-FC.response"
-msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team."
-msgid "SUN4-8000-FC.impact"
-msgstr "Loss of services provided by the device instances associated with this fault"
-msgid "SUN4-8000-FC.action"
-msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp illumos personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n"
-#
-# code: SUN4-8000-GQ
-# keys: fault.io.fire.datapath fault.io.fire.hbus
-#
-msgid "SUN4-8000-GQ.type"
-msgstr "Fault"
-msgid "SUN4-8000-GQ.severity"
-msgstr "Critical"
-msgid "SUN4-8000-GQ.description"
-msgstr "Fault in either the PCIe asic's internal hostbus or connector between IO and CPU Board\n Refer to %s for more information."
-msgid "SUN4-8000-GQ.response"
-msgstr "One or more device instances may be disabled\n"
-msgid "SUN4-8000-GQ.impact"
-msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
-msgid "SUN4-8000-GQ.action"
-msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
-#
-# code: SUN4-8000-HD
-# keys: fault.io.fire.hb.sw-config
-#
-msgid "SUN4-8000-HD.type"
-msgstr "Fault"
-msgid "SUN4-8000-HD.severity"
-msgstr "Critical"
-msgid "SUN4-8000-HD.description"
-msgstr "The IO hostbridge's hostbus has been found to be configured improperly\nwhich is preventing the system from functioning properly.\n Refer to %s for more information."
-msgid "SUN4-8000-HD.response"
-msgstr "One or more device instances may be disabled\n"
-msgid "SUN4-8000-HD.impact"
-msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
-msgid "SUN4-8000-HD.action"
-msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
-#
-# code: SUN4-8000-JH
-# keys: fault.io.fire.dmc.sw-algorithm
-#
-msgid "SUN4-8000-JH.type"
-msgstr "Fault"
-msgid "SUN4-8000-JH.severity"
-msgstr "Critical"
-msgid "SUN4-8000-JH.description"
-msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n Refer to %s for more information."
-msgid "SUN4-8000-JH.response"
-msgstr "One or more device instances may be disabled\n"
-msgid "SUN4-8000-JH.impact"
-msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
-msgid "SUN4-8000-JH.action"
-msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
-#
-# code: SUN4-8000-K3
-# keys: fault.io.fire.dmc.sw-state
-#
-msgid "SUN4-8000-K3.type"
-msgstr "Fault"
-msgid "SUN4-8000-K3.severity"
-msgstr "Critical"
-msgid "SUN4-8000-K3.description"
-msgstr "The IO hostbridge's Data Management Unit has been found to be in an illegal state\nwhich is preventing the system from functioning properly.\n Refer to %s for more information."
-msgid "SUN4-8000-K3.response"
-msgstr "One or more device instances may be disabled\n"
-msgid "SUN4-8000-K3.impact"
-msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
-msgid "SUN4-8000-K3.action"
-msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"
-#
-# code: SUN4-8000-LY
-# keys: fault.io.fire.pec.sw-algorithm
-#
-msgid "SUN4-8000-LY.type"
-msgstr "Fault"
-msgid "SUN4-8000-LY.severity"
-msgstr "Critical"
-msgid "SUN4-8000-LY.description"
-msgstr "An uncorrectable software problem was detected in the IO hostbridge's \nData Management Unit which is preventing the system from functioning properly.\n Refer to %s for more information."
-msgid "SUN4-8000-LY.response"
-msgstr "One or more device instances may be disabled\n"
-msgid "SUN4-8000-LY.impact"
-msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
-msgid "SUN4-8000-LY.action"
-msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n"