diff options
Diffstat (limited to 'usr/src')
| -rw-r--r-- | usr/src/cmd/fm/dicts/AMD.po | 6 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/FMD.po | 16 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/FMNOTIFY.po | 2 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/GMCA.po | 6 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/INTEL.po | 6 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/PCI.po | 26 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/PCIEX.po | 56 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/SCA1000.po | 8 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/SCA500.po | 8 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/SCF.po | 24 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/SUN4.po | 64 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/SUN4U.po | 386 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/SUN4V.po | 26 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/SUNOS.po | 46 | ||||
| -rw-r--r-- | usr/src/cmd/fm/dicts/ZFS.po | 2 |
15 files changed, 337 insertions, 345 deletions
diff --git a/usr/src/cmd/fm/dicts/AMD.po b/usr/src/cmd/fm/dicts/AMD.po index 5c111eebbf..0cdd49af09 100644 --- a/usr/src/cmd/fm/dicts/AMD.po +++ b/usr/src/cmd/fm/dicts/AMD.po @@ -34,7 +34,7 @@ msgstr "Minor" msgid "AMD-8000-1W.description" msgstr "The number of errors associated with this memory page has exceeded acceptable levels. Refer to %s for more information." msgid "AMD-8000-1W.response" -msgstr "\n\nIf Solaris is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n" +msgstr "\n\nIf illumos is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n" msgid "AMD-8000-1W.impact" msgstr "\n\nRemoving a single page from service (where supported) has a negligible impact on performance.\n" msgid "AMD-8000-1W.action" @@ -82,7 +82,7 @@ msgstr "Major" msgid "AMD-8000-48.description" msgstr "A memory module has produced an uncorrectable error. Refer to %s for more information." msgid "AMD-8000-48.response" -msgstr "\n\nIf Solaris is running on bare-metal (native) then affected memory pages associated with this memory module will be removed from service.\n" +msgstr "\n\nIf illumos is running on bare-metal (native) then affected memory pages associated with this memory module will be removed from service.\n" msgid "AMD-8000-48.impact" msgstr "\n\nPage retirement (where supported) is capped at a small fraction of memory to avoid performance impact.\n" msgid "AMD-8000-48.action" @@ -294,7 +294,7 @@ msgstr "A cpu has likely been offlined in response to this misdiagnosis.\n" msgid "AMD-8000-JF.impact" msgstr "Performance of this system may be affected." msgid "AMD-8000-JF.action" -msgstr "Online any CPU that was automatically offlined in response to this fault\n(use fmdump -v -u <EVENT_ID> to identify the CPU). The fault\nshould also be repaired with fmadm repair <EVENT_ID>.\nThis misdiagnosis bug is being fixed - patch numbers for Solaris 10\nwill appear here when aavailable.\n\n" +msgstr "Online any CPU that was automatically offlined in response to this fault\n(use fmdump -v -u <EVENT_ID> to identify the CPU). The fault\nshould also be repaired with fmadm repair <EVENT_ID>.\nThis misdiagnosis bug is being fixed - bug numbers for illumos\nwill appear here when available.\n\n" # # code: AMD-8000-KW # keys: fault.cpu.amd.dramchannel diff --git a/usr/src/cmd/fm/dicts/FMD.po b/usr/src/cmd/fm/dicts/FMD.po index 1c2b545896..16d7fd7c8d 100644 --- a/usr/src/cmd/fm/dicts/FMD.po +++ b/usr/src/cmd/fm/dicts/FMD.po @@ -41,13 +41,13 @@ msgstr "Defect" msgid "FMD-8000-0W.severity" msgstr "Minor" msgid "FMD-8000-0W.description" -msgstr "The Solaris Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed. Refer to %s for more information." +msgstr "The illumos Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed. Refer to %s for more information." msgid "FMD-8000-0W.response" -msgstr "Error reports from the component will be logged for examination by Sun." +msgstr "Error reports from the component will be logged for examination by your illumos distribution team." msgid "FMD-8000-0W.impact" msgstr "Automated diagnosis and response for these events will not occur." msgid "FMD-8000-0W.action" -msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support." +msgstr "Ensure that fault management software is installed properly. Contact your illumos distribution team for support." # # code: FMD-8000-11 # keys: defect.sunos.fmd.nodiagcode @@ -57,13 +57,13 @@ msgstr "Defect" msgid "FMD-8000-11.severity" msgstr "Minor" msgid "FMD-8000-11.description" -msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists. Refer to %s for more information." +msgstr "An illumos Fault Manager component generated a diagnosis for which no message summary exists. Refer to %s for more information." msgid "FMD-8000-11.response" -msgstr "The diagnosis has been saved in the fault log for examination by Sun." +msgstr "The diagnosis has been saved in the fault log for examination by your illumos distribution team." msgid "FMD-8000-11.impact" msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." msgid "FMD-8000-11.action" -msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly." +msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Ensure that fault management software is installed properly." # # code: FMD-8000-2K # keys: defect.sunos.fmd.module @@ -73,7 +73,7 @@ msgstr "Defect" msgid "FMD-8000-2K.severity" msgstr "Minor" msgid "FMD-8000-2K.description" -msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled. Refer to %s for more information." +msgstr "An illumos Fault Manager component has experienced an error that required the module to be disabled. Refer to %s for more information." msgid "FMD-8000-2K.response" msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." msgid "FMD-8000-2K.impact" @@ -89,7 +89,7 @@ msgstr "Defect" msgid "FMD-8000-3F.severity" msgstr "Minor" msgid "FMD-8000-3F.description" -msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file. Refer to %s for more information." +msgstr "An illumos Fault Manager component could not load due to an erroroneous configuration file. Refer to %s for more information." msgid "FMD-8000-3F.response" msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." msgid "FMD-8000-3F.impact" diff --git a/usr/src/cmd/fm/dicts/FMNOTIFY.po b/usr/src/cmd/fm/dicts/FMNOTIFY.po index 29c9bb1176..c239a8c880 100644 --- a/usr/src/cmd/fm/dicts/FMNOTIFY.po +++ b/usr/src/cmd/fm/dicts/FMNOTIFY.po @@ -30,7 +30,7 @@ # params: hostname, code # msgid "smtp-notify-subject-template" -msgstr "Solaris Event Notification:%s:%s" +msgstr "illumos Event Notification:%s:%s" # # format for subject of emails generated by the smtp-notify agent diff --git a/usr/src/cmd/fm/dicts/GMCA.po b/usr/src/cmd/fm/dicts/GMCA.po index 6962759b7d..77b2f93007 100644 --- a/usr/src/cmd/fm/dicts/GMCA.po +++ b/usr/src/cmd/fm/dicts/GMCA.po @@ -482,7 +482,7 @@ msgstr "Minor" msgid "GMCA-8000-WT.description" msgstr "A page of memory is reporting excessive ECC errors. Refer to %s for more information." msgid "GMCA-8000-WT.response" -msgstr "\n\nIf Solaris is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n" +msgstr "\n\nIf illumos is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n" msgid "GMCA-8000-WT.impact" msgstr "\n\nRemoving a single page from service (where supported) has a negligible impact on performance.\n" msgid "GMCA-8000-WT.action" @@ -498,7 +498,7 @@ msgstr "Major" msgid "GMCA-8000-X9.description" msgstr "An uncorrectable error was reported on a memory page. Refer to %s for more information." msgid "GMCA-8000-X9.response" -msgstr "\n\nIf Solaris is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n" +msgstr "\n\nIf illumos is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n" msgid "GMCA-8000-X9.impact" msgstr "\n\nRemoving a single page from service (where supported) has a negligible impact on performance.\n" msgid "GMCA-8000-X9.action" @@ -530,7 +530,7 @@ msgstr "Critical" msgid "GMCA-8001-09.description" msgstr "A memory module has suffered an uncorrectable error. Refer to %s for more information." msgid "GMCA-8001-09.response" -msgstr "\n\nIf Solaris is running on bare-metal (native) then affected memory pages associated with this memory module will be removed from service.\n" +msgstr "\n\nIf illumos is running on bare-metal (native) then affected memory pages associated with this memory module will be removed from service.\n" msgid "GMCA-8001-09.impact" msgstr "\n\nPage retirement (where supported) is capped at a small fraction of memory to avoid performance impact.\n" msgid "GMCA-8001-09.action" diff --git a/usr/src/cmd/fm/dicts/INTEL.po b/usr/src/cmd/fm/dicts/INTEL.po index 8d1b59f08a..2f1314e51b 100644 --- a/usr/src/cmd/fm/dicts/INTEL.po +++ b/usr/src/cmd/fm/dicts/INTEL.po @@ -642,7 +642,7 @@ msgstr "Minor" msgid "INTEL-8001-7H.description" msgstr "A page of memory has reported excessive correctable ECC errors. Refer to %s for more information." msgid "INTEL-8001-7H.response" -msgstr "\n\nIf Solaris is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n" +msgstr "\n\nIf illumos is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n" msgid "INTEL-8001-7H.impact" msgstr "\n\nRemoving a single page from service (where supported) has a negligible impact on performance.\n" msgid "INTEL-8001-7H.action" @@ -658,7 +658,7 @@ msgstr "Major" msgid "INTEL-8001-8R.description" msgstr "A page of memory has encountered an uncorrectable multiple-bit error. This fault class is an internal implementation peculiarity and can be ignored by system administrators; action is only necessary if it is followed by a related dimm fault diagnosis (as should always be the case for uncorrectable errors). Refer to %s for more information." msgid "INTEL-8001-8R.response" -msgstr "\n\nIf Solaris is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n" +msgstr "\n\nIf illumos is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n" msgid "INTEL-8001-8R.impact" msgstr "\n\nRemoving a single page from service (where supported) has a negligible impact on performance.\n" msgid "INTEL-8001-8R.action" @@ -690,7 +690,7 @@ msgstr "Critical" msgid "INTEL-8001-AQ.description" msgstr "A memory module has experienced an uncorrectable multiple-bit error. Refer to %s for more information." msgid "INTEL-8001-AQ.response" -msgstr "\n\nIf Solaris is running on bare-metal (native) then affected memory pages associated with this memory module will be removed from service.\n" +msgstr "\n\nIf illumos is running on bare-metal (native) then affected memory pages associated with this memory module will be removed from service.\n" msgid "INTEL-8001-AQ.impact" msgstr "\n\nPage retirement (where supported) is capped at a small fraction of memory to avoid performance impact.\n" msgid "INTEL-8001-AQ.action" diff --git a/usr/src/cmd/fm/dicts/PCI.po b/usr/src/cmd/fm/dicts/PCI.po index c8a63c56e9..27f75bc878 100644 --- a/usr/src/cmd/fm/dicts/PCI.po +++ b/usr/src/cmd/fm/dicts/PCI.po @@ -38,7 +38,7 @@ msgstr "One or more of device instances may be disabled." msgid "PCI-8000-0C.impact" msgstr "Loss of services provided by the device instances associated with this problem." msgid "PCI-8000-0C.action" -msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." +msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support." # # code: PCI-8000-1Q # keys: fault.io.pci.bus @@ -54,7 +54,7 @@ msgstr "One or more device instances may be disabled." msgid "PCI-8000-1Q.impact" msgstr "Loss of services provided by the device instances associated with this fault." msgid "PCI-8000-1Q.action" -msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." +msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support." # # code: PCI-8000-24 # keys: defect.io.pci.driver fault.io.pci.bus @@ -150,7 +150,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-7J.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-7J.action" -msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n" # # code: PCI-8000-8S # keys: fault.io.pci.bus-linkerr fault.io.pci.device-interr @@ -166,7 +166,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-8S.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-8S.action" -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.\n" +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n" # # code: PCI-8000-95 # keys: fault.io.pci.device-invreq fault.io.pci.device-noresp @@ -182,7 +182,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-95.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-95.action" -msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCI-8000-AP # keys: fault.io.pci.device-interr fault.io.pci.device-invreq @@ -198,7 +198,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-AP.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-AP.action" -msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCI-8000-CA # keys: fault.io.pci.device-noresp @@ -214,7 +214,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-CA.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-CA.action" -msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n" # # code: PCI-8000-DH # keys: fault.io.pci.bus-linkerr-unaf fault.io.pci.device-interr-unaf @@ -230,7 +230,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-DH.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-DH.action" -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.\n" +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n" # # code: PCI-8000-ED # keys: fault.io.pci.device-interr-corr @@ -246,7 +246,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCI-8000-ED.impact" msgstr "Possible loss of services provided by the device instances associated with this fault\n" msgid "PCI-8000-ED.action" -msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n" # # code: PCI-8000-FY # keys: fault.io.pci.bus-linkerr-deg fault.io.pci.device-interr-deg @@ -262,7 +262,7 @@ msgstr "None\n" msgid "PCI-8000-FY.impact" msgstr "Degraded services provided by the device instances associated with this fault\n" msgid "PCI-8000-FY.action" -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.\n" +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n" # # code: PCI-8000-G3 # keys: fault.io.pci.device-interr-deg @@ -278,7 +278,7 @@ msgstr "None\n" msgid "PCI-8000-G3.impact" msgstr "Degraded services provided by the device instances associated with this fault\n" msgid "PCI-8000-G3.action" -msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n" # # code: PCI-8000-HR # keys: fault.io.pci.fw_corrupt @@ -294,7 +294,7 @@ msgstr "One or more device instances may be disabled.\n" msgid "PCI-8000-HR.impact" msgstr "Degraded services provided by the device instances associated with this fault.\n" msgid "PCI-8000-HR.action" -msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact Sun support for further information.\n" +msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact your illumos distribution team for further information.\n" # # code: PCI-8000-J4 # keys: fault.io.pci.fw_mismatch @@ -310,4 +310,4 @@ msgstr "One or more device instances may be disabled.\n" msgid "PCI-8000-J4.impact" msgstr "Degraded services provided by the device instances associated with this fault.\n" msgid "PCI-8000-J4.action" -msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version. Contact Sun support for further information.\n" +msgstr "Use fmadm faulty to identify the device and then update the firmware to the latest version. Contact your illumos distribution team for further information.\n" diff --git a/usr/src/cmd/fm/dicts/PCIEX.po b/usr/src/cmd/fm/dicts/PCIEX.po index a35c83b22a..12224435a8 100644 --- a/usr/src/cmd/fm/dicts/PCIEX.po +++ b/usr/src/cmd/fm/dicts/PCIEX.po @@ -38,7 +38,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-0A.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-0A.action" -msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-1P # keys: fault.io.pciex.device-interr fault.io.pciex.device-invreq @@ -54,7 +54,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-1P.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-1P.action" -msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-25 # keys: fault.io.pciex.bus-noresp fault.io.pciex.device-noresp @@ -70,7 +70,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-25.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-25.action" -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-3S # keys: fault.io.pciex.bus-linkerr fault.io.pciex.device-interr @@ -86,7 +86,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-3S.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-3S.action" -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-43 # keys: fault.io.pci.bus-linkerr fault.io.pciex.device-interr @@ -102,7 +102,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-43.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-43.action" -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.\n" +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-5Y # keys: fault.io.pci.device-invreq @@ -118,7 +118,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-5Y.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-5Y.action" -msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support." +msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support." # # code: PCIEX-8000-6D # keys: fault.io.pci.device-invreq fault.io.pciex.device-interr @@ -134,7 +134,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-6D.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-6D.action" -msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-7H # keys: fault.io.pci.device-interr fault.io.pciex.device-invreq @@ -150,7 +150,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-7H.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-7H.action" -msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-8R # keys: fault.io.pciex.device-invreq @@ -166,7 +166,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-8R.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-8R.action" -msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-94 # keys: fault.io.pci.device-noresp fault.io.pciex.device-invreq @@ -182,7 +182,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-94.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-94.action" -msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-AQ # keys: fault.io.pci.device-invreq fault.io.pciex.device-noresp @@ -198,7 +198,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-AQ.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-AQ.action" -msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-CC # keys: fault.io.pci.bus-linkerr fault.io.pci.device-interr fault.io.pciex.device-interr @@ -214,7 +214,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-CC.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-CC.action" -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-DJ # keys: fault.io.pciex.bus-noresp fault.io.pciex.device-interr fault.io.pciex.device-noresp @@ -230,7 +230,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-DJ.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-DJ.action" -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-EE # keys: fault.io.pciex.bus-linkerr fault.io.pciex.bus-noresp fault.io.pciex.device-interr fault.io.pciex.device-noresp @@ -246,7 +246,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-EE.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-EE.action" -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-FX # keys: fault.io.pciex.bus-linkerr fault.io.pciex.bus-noresp fault.io.pciex.device-interr fault.io.pciex.device-invreq fault.io.pciex.device-noresp @@ -262,7 +262,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-FX.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-FX.action" -msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-G2 # keys: fault.io.pciex.bus-noresp fault.io.pciex.device-interr fault.io.pciex.device-invreq fault.io.pciex.device-noresp @@ -278,7 +278,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-G2.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-G2.action" -msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-HS # keys: fault.io.pciex.bus-noresp fault.io.pciex.device-interr @@ -294,7 +294,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-HS.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-HS.action" -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.\n" +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-J5 # keys: fault.io.pciex.device-interr-corr @@ -310,7 +310,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-J5.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-J5.action" -msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-KP # keys: fault.io.pciex.bus-linkerr-corr fault.io.pciex.device-interr-corr @@ -326,7 +326,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-KP.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-KP.action" -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-LA # keys: fault.io.pci.bus-linkerr-unaf fault.io.pciex.device-interr-unaf @@ -342,7 +342,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-LA.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-LA.action" -msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.\n" +msgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-MH # keys: fault.io.pciex.device-interr-unaf @@ -358,7 +358,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-MH.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-MH.action" -msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-ND # keys: fault.io.pciex.device-interr-deg @@ -374,7 +374,7 @@ msgstr "None\n" msgid "PCIEX-8000-ND.impact" msgstr "Degraded services provided by the device instances associated with this fault\n" msgid "PCIEX-8000-ND.action" -msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-PY # keys: fault.io.pciex.fw_corrupt @@ -390,7 +390,7 @@ msgstr "One or more device instances may be disabled.\n" msgid "PCIEX-8000-PY.impact" msgstr "Degraded services provided by the device instances associated with this fault.\n" msgid "PCIEX-8000-PY.action" -msgstr "Use 'fmadm faulty' to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact Sun support for further information.\n" +msgstr "Use 'fmadm faulty' to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact your illumos distribution team for further information.\n" # # code: PCIEX-8000-Q3 # keys: fault.io.pciex.fw_mismatch @@ -406,7 +406,7 @@ msgstr "One or more device instances may be disabled.\n" msgid "PCIEX-8000-Q3.impact" msgstr "Degraded services provided by the device instances associated with this fault.\n" msgid "PCIEX-8000-Q3.action" -msgstr "Use 'fmadm faulty' to identify the device and then update the firmware to the latest version. Contact Sun support for further information.\n" +msgstr "Use 'fmadm faulty' to identify the device and then update the firmware to the latest version. Contact your illumos distribution team for further information.\n" # # code: PCIEX-8000-RC # keys: fault.io.pciex.rc.generic-ce @@ -422,7 +422,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-RC.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "PCIEX-8000-RC.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-SQ # keys: fault.io.pciex.rc.generic-ue @@ -438,7 +438,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-SQ.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "PCIEX-8000-SQ.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-T4 # keys: fault.io.pciex.rc.generic-sw @@ -454,7 +454,7 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-T4.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "PCIEX-8000-T4.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: PCIEX-8000-UR # keys: fault.io.pciex.rc.generic-fw @@ -470,4 +470,4 @@ msgstr "One or more device instances may be disabled\n" msgid "PCIEX-8000-UR.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "PCIEX-8000-UR.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" diff --git a/usr/src/cmd/fm/dicts/SCA1000.po b/usr/src/cmd/fm/dicts/SCA1000.po index 8e1795d672..2a8e1c8ab4 100644 --- a/usr/src/cmd/fm/dicts/SCA1000.po +++ b/usr/src/cmd/fm/dicts/SCA1000.po @@ -21,8 +21,6 @@ # # CDDL HEADER END # -#ident "%Z%%M% %I% %E% SMI" -# # DO NOT EDIT -- this file is generated by the Event Registry. # # @@ -34,10 +32,10 @@ msgstr "Fault" msgid "SCA1000-8000-0V.severity" msgstr "Major" msgid "SCA1000-8000-0V.description" -msgstr "The Solaris Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 1000 card. Refer to %s for more information." +msgstr "The illumos Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 1000 card. Refer to %s for more information." msgid "SCA1000-8000-0V.response" -msgstr "The module has been disabled and un-registered as a hardware provider to the Solaris Cryptographic Framework." +msgstr "The module has been disabled and un-registered as a hardware provider to the illumos Cryptographic Framework." msgid "SCA1000-8000-0V.impact" msgstr "The card will no longer function as a cryptographic accelerator." msgid "SCA1000-8000-0V.action" -msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(1M) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider using SUNVTS\nfollowing the procedures described in the Sun Crypto Accelerator 1000 Board\nUser's Guide.\n\nUse the fmdump(1M) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n" +msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(1M) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider\nfollowing the procedures described in the Sun Crypto Accelerator 1000 Board\nUser's Guide.\n\nUse the fmdump(1M) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n" diff --git a/usr/src/cmd/fm/dicts/SCA500.po b/usr/src/cmd/fm/dicts/SCA500.po index c39feb8032..46a0475572 100644 --- a/usr/src/cmd/fm/dicts/SCA500.po +++ b/usr/src/cmd/fm/dicts/SCA500.po @@ -21,8 +21,6 @@ # # CDDL HEADER END # -#ident "%Z%%M% %I% %E% SMI" -# # DO NOT EDIT -- this file is generated by the Event Registry. # # @@ -34,10 +32,10 @@ msgstr "Fault" msgid "SCA500-8000-0D.severity" msgstr "Major" msgid "SCA500-8000-0D.description" -msgstr "The Solaris Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 500 card. Refer to %s for more information." +msgstr "The illumos Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 500 card. Refer to %s for more information." msgid "SCA500-8000-0D.response" -msgstr "The module has been disabled and un-registered as a hardware provider to the Solaris Cryptographic Framework." +msgstr "The module has been disabled and un-registered as a hardware provider to the illumos Cryptographic Framework." msgid "SCA500-8000-0D.impact" msgstr "The card will no longer function as a cryptographic accelerator." msgid "SCA500-8000-0D.action" -msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(1M) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider using SUNVTS\nfollowing the procedures described in the Sun Crypto Accelerator 1000 Board\nUser's Guide.\n\nUse the fmdump(1M) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n" +msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(1M) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider\nfollowing the procedures described in the Sun Crypto Accelerator 500 Board\nUser's Guide.\n\nUse the fmdump(1M) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n" diff --git a/usr/src/cmd/fm/dicts/SCF.po b/usr/src/cmd/fm/dicts/SCF.po index 4a9aa11098..160a515fdc 100644 --- a/usr/src/cmd/fm/dicts/SCF.po +++ b/usr/src/cmd/fm/dicts/SCF.po @@ -21,8 +21,6 @@ # # CDDL HEADER END # -#ident "%Z%%M% %I% %E% SMI" -# # DO NOT EDIT -- this file is generated by the Event Registry. # # @@ -482,7 +480,7 @@ msgstr "upset" msgid "SCF-8001-KC.severity" msgstr "Critical" msgid "SCF-8001-KC.description" -msgstr "Failure to boot Solaris on a domain via an internal disk drive on the SAS controller.\n Refer to %s for more information." +msgstr "Failure to boot illumos on a domain via an internal disk drive on the SAS controller.\n Refer to %s for more information." msgid "SCF-8001-KC.response" msgstr "Nothing is deconfigured.\n" msgid "SCF-8001-KC.impact" @@ -850,7 +848,7 @@ msgstr "Upset" msgid "SCF-8002-9H.severity" msgstr "Critical" msgid "SCF-8002-9H.description" -msgstr "Failure to boot Solaris on a domain using a device on an IO Channel.\n Refer to %s for more information." +msgstr "Failure to boot illumos on a domain using a device on an IO Channel.\n Refer to %s for more information." msgid "SCF-8002-9H.response" msgstr "Nothing is deconfigured.\n" msgid "SCF-8002-9H.impact" @@ -866,7 +864,7 @@ msgstr "Upset" msgid "SCF-8002-A3.severity" msgstr "Critical" msgid "SCF-8002-A3.description" -msgstr "Failure to boot Solaris on a domain using a device on IO Channel leaf (1/2 an IO Channel).\n Refer to %s for more information." +msgstr "Failure to boot illumos on a domain using a device on IO Channel leaf (1/2 an IO Channel).\n Refer to %s for more information." msgid "SCF-8002-A3.response" msgstr "Nothing is deconfigured.\n" msgid "SCF-8002-A3.impact" @@ -882,7 +880,7 @@ msgstr "Upset" msgid "SCF-8002-CY.severity" msgstr "Critical" msgid "SCF-8002-CY.description" -msgstr "Failure to boot Solaris on a domain via GbE.\n Refer to %s for more information." +msgstr "Failure to boot illumos on a domain via GbE.\n Refer to %s for more information." msgid "SCF-8002-CY.response" msgstr "Nothing is deconfigured.\n" msgid "SCF-8002-CY.impact" @@ -898,7 +896,7 @@ msgstr "Upset" msgid "SCF-8002-D5.severity" msgstr "Critical" msgid "SCF-8002-D5.description" -msgstr "Failure to boot Solaris on a domain using a device in a PCI-X slot.\n Refer to %s for more information." +msgstr "Failure to boot illumos on a domain using a device in a PCI-X slot.\n Refer to %s for more information." msgid "SCF-8002-D5.response" msgstr "Nothing is deconfigured.\n" msgid "SCF-8002-D5.impact" @@ -914,7 +912,7 @@ msgstr "Upset" msgid "SCF-8002-ES.severity" msgstr "Critical" msgid "SCF-8002-ES.description" -msgstr "Failure to boot Solaris on a domain using a device in a PCI-Express slot.\n Refer to %s for more information." +msgstr "Failure to boot illumos on a domain using a device in a PCI-Express slot.\n Refer to %s for more information." msgid "SCF-8002-ES.response" msgstr "Nothing is deconfigured.\n" msgid "SCF-8002-ES.impact" @@ -930,7 +928,7 @@ msgstr "Upset" msgid "SCF-8002-FA.severity" msgstr "Critical" msgid "SCF-8002-FA.description" -msgstr "Failure to boot Solaris on a domain using a device behind a PCI-Express/PCI-X \nbridge chip. This includes the PCI-X slot and internal I/O on an IOU (if the\nPCI-Express/PCI-X bridge is located on an IOU or IOUA) and the PCI-X slots of\nan I/O Boat (if the PCI-Express/PCI-X bridge is located on an I/O Boat).\n Refer to %s for more information." +msgstr "Failure to boot illumos on a domain using a device behind a PCI-Express/PCI-X \nbridge chip. This includes the PCI-X slot and internal I/O on an IOU (if the\nPCI-Express/PCI-X bridge is located on an IOU or IOUA) and the PCI-X slots of\nan I/O Boat (if the PCI-Express/PCI-X bridge is located on an I/O Boat).\n Refer to %s for more information." msgid "SCF-8002-FA.response" msgstr "Nothing is deconfigured.\n" msgid "SCF-8002-FA.impact" @@ -946,7 +944,7 @@ msgstr "upset" msgid "SCF-8002-GP.severity" msgstr "Critical" msgid "SCF-8002-GP.description" -msgstr "Failure to boot Solaris on a domain using a device behind a PCI-Express switch chip.\nThis includes PCI-X slot and internal I/O devices (if the PCI-Express switch chip \nis located on an IOU), and the PCI-Express slots and PCI-X slots on an I/O Boat\n(if the PCI-Express switch chip is located on an I/O Boat).\n Refer to %s for more information." +msgstr "Failure to boot illumos on a domain using a device behind a PCI-Express switch chip.\nThis includes PCI-X slot and internal I/O devices (if the PCI-Express switch chip \nis located on an IOU), and the PCI-Express slots and PCI-X slots on an I/O Boat\n(if the PCI-Express switch chip is located on an I/O Boat).\n Refer to %s for more information." msgid "SCF-8002-GP.response" msgstr "Nothing is deconfigured.\n" msgid "SCF-8002-GP.impact" @@ -962,7 +960,7 @@ msgstr "Upset" msgid "SCF-8002-HE.severity" msgstr "Critical" msgid "SCF-8002-HE.description" -msgstr "Failure to boot Solaris on a domain using an internal SAS (Serial Attached\nSCSI) device. This includes the internal hard drives and the internal DVD drives\nand the internal tape drives.\n Refer to %s for more information." +msgstr "Failure to boot illumos on a domain using an internal SAS (Serial Attached\nSCSI) device. This includes the internal hard drives and the internal DVD drives\nand the internal tape drives.\n Refer to %s for more information." msgid "SCF-8002-HE.response" msgstr "Nothing is deconfigured.\n" msgid "SCF-8002-HE.impact" @@ -2002,11 +2000,11 @@ msgstr "Upset" msgid "SCF-8005-PX.severity" msgstr "Major" msgid "SCF-8005-PX.description" -msgstr "The XSCF has detected that a Solaris domain has panic'ed.\n Refer to %s for more information." +msgstr "The XSCF has detected that an illumos domain has panic'ed.\n Refer to %s for more information." msgid "SCF-8005-PX.response" msgstr "No action is taken due to this fault.\n" msgid "SCF-8005-PX.impact" -msgstr "The Solaris domain has panic'ed.\n" +msgstr "The illumos domain has panic'ed.\n" msgid "SCF-8005-PX.action" msgstr "The administrator should look at the domain's console to identify the cause of the panic.\nPlease consult the detail section of the knowledge article for additional information.\n" # diff --git a/usr/src/cmd/fm/dicts/SUN4.po b/usr/src/cmd/fm/dicts/SUN4.po index c804c36e79..b1df0f35b1 100644 --- a/usr/src/cmd/fm/dicts/SUN4.po +++ b/usr/src/cmd/fm/dicts/SUN4.po @@ -21,8 +21,6 @@ # # CDDL HEADER END # -#ident "%Z%%M% %I% %E% SMI" -# # DO NOT EDIT -- this file is generated by the Event Registry. # # @@ -36,11 +34,11 @@ msgstr "Critical" msgid "SUN4-8000-0Y.description" msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." msgid "SUN4-8000-0Y.response" -msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." +msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." msgid "SUN4-8000-0Y.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-0Y.action" -msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" +msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" # # code: SUN4-8000-13 # keys: fault.io.ebus @@ -52,11 +50,11 @@ msgstr "Critical" msgid "SUN4-8000-13.description" msgstr "A problem was detected in the Ebus. Refer to %s for more information." msgid "SUN4-8000-13.response" -msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." +msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." msgid "SUN4-8000-13.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-13.action" -msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u \nEVENT_ID to collect information to help Sun Service personnel \nidentify the device in need of repair. Schedule a repair procedure to replace \nthe affected device.\n" +msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u \nEVENT_ID to collect information to help illumos personnel \nidentify the device in need of repair. Schedule a repair procedure to replace \nthe affected device.\n" # # code: SUN4-8000-2H # keys: fault.io.datapath @@ -66,7 +64,7 @@ msgstr "Fault" msgid "SUN4-8000-2H.severity" msgstr "Critical" msgid "SUN4-8000-2H.description" -msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." +msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details. Refer to %s for more information." msgid "SUN4-8000-2H.response" msgstr "None" msgid "SUN4-8000-2H.impact" @@ -84,11 +82,11 @@ msgstr "Critical" msgid "SUN4-8000-3D.description" msgstr "A problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4-8000-3D.response" -msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." +msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." msgid "SUN4-8000-3D.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-3D.action" -msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n" +msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp illumos personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n" # # code: SUN4-8000-4P # keys: fault.io.fire.pciex.device @@ -100,11 +98,11 @@ msgstr "Critical" msgid "SUN4-8000-4P.description" msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." msgid "SUN4-8000-4P.response" -msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." +msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." msgid "SUN4-8000-4P.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-4P.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. \nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below." +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. \nIf this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below." # # code: SUN4-8000-5A # keys: defect.io.fire.pciex.driver @@ -116,11 +114,11 @@ msgstr "Critical" msgid "SUN4-8000-5A.description" msgstr "A problem was detected in the PCI-Express subsystem software.\n Refer to %s for more information." msgid "SUN4-8000-5A.response" -msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." +msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." msgid "SUN4-8000-5A.impact" msgstr "Loss of services provided by the device instances associated with\nthis problem" msgid "SUN4-8000-5A.action" -msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." +msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support." # # code: SUN4-8000-6S # keys: fault.io.datapath fault.io.fire.asic @@ -130,7 +128,7 @@ msgstr "Fault" msgid "SUN4-8000-6S.severity" msgstr "Critical" msgid "SUN4-8000-6S.description" -msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." +msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details. Refer to %s for more information." msgid "SUN4-8000-6S.response" msgstr "None" msgid "SUN4-8000-6S.impact" @@ -148,11 +146,11 @@ msgstr "Critical" msgid "SUN4-8000-75.description" msgstr "A problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." msgid "SUN4-8000-75.response" -msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." +msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." msgid "SUN4-8000-75.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-75.action" -msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" +msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" # # code: SUN4-8000-8E # keys: defect.io.fire.pci.driver defect.io.fire.pciex.driver @@ -164,11 +162,11 @@ msgstr "Critical" msgid "SUN4-8000-8E.description" msgstr "A problem was detected in the PCI-Express subsystem software. Refer to %s for more information." msgid "SUN4-8000-8E.response" -msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." +msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." msgid "SUN4-8000-8E.impact" msgstr "Loss of services provided by the device instances associated with this problem" msgid "SUN4-8000-8E.action" -msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." +msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support." # # code: SUN4-8000-9J # keys: fault.io.fire.pci.device fault.io.fire.pciex.device @@ -178,7 +176,7 @@ msgstr "Fault" msgid "SUN4-8000-9J.severity" msgstr "Critical" msgid "SUN4-8000-9J.description" -msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." +msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details. Refer to %s for more information." msgid "SUN4-8000-9J.response" msgstr "None" msgid "SUN4-8000-9J.impact" @@ -196,11 +194,11 @@ msgstr "Critical" msgid "SUN4-8000-A2.description" msgstr "A problem was detected in the PCI subsystem.\n Refer to %s for more information." msgid "SUN4-8000-A2.response" -msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." +msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." msgid "SUN4-8000-A2.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-A2.action" -msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4-8000-CX # keys: defect.io.fire.pciex.driver fault.io.datapath fault.io.fire.asic @@ -210,7 +208,7 @@ msgstr "Fault" msgid "SUN4-8000-CX.severity" msgstr "Critical" msgid "SUN4-8000-CX.description" -msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." +msgstr "This is an unexpected diagnosis. Please contact your illumos distribution team for details. Refer to %s for more information." msgid "SUN4-8000-CX.response" msgstr "None" msgid "SUN4-8000-CX.impact" @@ -228,11 +226,11 @@ msgstr "Critical" msgid "SUN4-8000-D4.description" msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information." msgid "SUN4-8000-D4.response" -msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." +msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." msgid "SUN4-8000-D4.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-D4.action" -msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" +msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" # # code: SUN4-8000-ER # keys: fault.io.fire.asic fault.io.fire.pci.device @@ -244,11 +242,11 @@ msgstr "Critical" msgid "SUN4-8000-ER.description" msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information." msgid "SUN4-8000-ER.response" -msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." +msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." msgid "SUN4-8000-ER.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-ER.action" -msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" +msgstr "Schedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support. If this message occurs on a Sun Fire T2000 also refer to the NOTE\nat the end of the Details section below.\n" # # code: SUN4-8000-FC # keys: fault.io.fire.hbus @@ -260,11 +258,11 @@ msgstr "Major" msgid "SUN4-8000-FC.description" msgstr "A problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4-8000-FC.response" -msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or Sun Services." +msgstr "This fault does not have an automated response agent and thus requires interaction \nfrom the user and/or your illumos distribution team." msgid "SUN4-8000-FC.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-FC.action" -msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp Sun Service personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n" +msgstr "Use fmdump -v -u EVENT_ID and fmdump -eV -u\nEVENT_ID to collect information to \nhelp illumos personnel identify the device in need of repair. Schedule \na repair procedure to replace the affected device.\n" # # code: SUN4-8000-GQ # keys: fault.io.fire.datapath fault.io.fire.hbus @@ -280,7 +278,7 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4-8000-GQ.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "SUN4-8000-GQ.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: SUN4-8000-HD # keys: fault.io.fire.hb.sw-config @@ -296,7 +294,7 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4-8000-HD.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "SUN4-8000-HD.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: SUN4-8000-JH # keys: fault.io.fire.dmc.sw-algorithm @@ -312,7 +310,7 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4-8000-JH.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "SUN4-8000-JH.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: SUN4-8000-K3 # keys: fault.io.fire.dmc.sw-state @@ -328,7 +326,7 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4-8000-K3.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "SUN4-8000-K3.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: SUN4-8000-LY # keys: fault.io.fire.pec.sw-algorithm @@ -344,4 +342,4 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4-8000-LY.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "SUN4-8000-LY.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" diff --git a/usr/src/cmd/fm/dicts/SUN4U.po b/usr/src/cmd/fm/dicts/SUN4U.po index e8d2cfb2aa..e6ea7d53e7 100644 --- a/usr/src/cmd/fm/dicts/SUN4U.po +++ b/usr/src/cmd/fm/dicts/SUN4U.po @@ -561,9 +561,9 @@ msgstr "Defect" msgid "SUN4U-8001-2X.severity" msgstr "Minor" msgid "SUN4U-8001-2X.description" -msgstr "The Solaris Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable. Refer to %s for more information." +msgstr "The illumos Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable. Refer to %s for more information." msgid "SUN4U-8001-2X.response" -msgstr "The error information has been saved for examination by Sun." +msgstr "The error information has been saved for examination by your illumos distribution team." msgid "SUN4U-8001-2X.impact" msgstr "The error log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." msgid "SUN4U-8001-2X.action" @@ -579,7 +579,7 @@ msgstr "Major" msgid "SUN4U-8001-32.description" msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system. Refer to %s for more information." msgid "SUN4U-8001-32.response" -msgstr "Error reports from the affected components will be logged for examination by Sun." +msgstr "Error reports from the affected components will be logged for examination by your illumos distribution team." msgid "SUN4U-8001-32.impact" msgstr "System performance and stability may be affected." msgid "SUN4U-8001-32.action" @@ -599,7 +599,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-4R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-4R.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-54 # keys: defect.io.pci.driver fault.io.datapath @@ -615,7 +615,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-54.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-54.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-6Q # keys: fault.io.datapath fault.io.pci.bus @@ -631,7 +631,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-6Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-6Q.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-7C # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus @@ -647,7 +647,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-7C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-7C.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-83 # keys: fault.io.datapath fault.io.pci.device @@ -663,7 +663,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-83.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-83.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-9Y # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device @@ -679,7 +679,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-9Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-9Y.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-AD # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device @@ -695,7 +695,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-AD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-AD.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-CH # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device @@ -711,7 +711,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-CH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-CH.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-DA # keys: fault.io.hbus @@ -727,7 +727,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-DA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-DA.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-EP # keys: defect.io.pci.driver fault.io.hbus @@ -743,7 +743,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-EP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-EP.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-F5 # keys: fault.io.hbus fault.io.pci.bus @@ -759,7 +759,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-F5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-F5.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-GS # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus @@ -775,7 +775,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-GS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-GS.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-H2 # keys: fault.io.hbus fault.io.pci.device @@ -791,7 +791,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-H2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-H2.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-JX # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device @@ -807,7 +807,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-JX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-JX.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-KE # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device @@ -823,7 +823,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-KE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-KE.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-LJ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device @@ -839,7 +839,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-LJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-LJ.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-MC # keys: fault.io.datapath fault.io.hbus @@ -855,7 +855,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-MC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-MC.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-NQ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus @@ -871,7 +871,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-NQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-NQ.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-P4 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus @@ -887,7 +887,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-P4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-P4.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-QR # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus @@ -903,7 +903,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-QR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-QR.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-RH # keys: fault.io.datapath fault.io.hbus fault.io.pci.device @@ -919,7 +919,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-RH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-RH.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-SD # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device @@ -935,7 +935,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-SD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-SD.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-TY # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device @@ -951,7 +951,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-TY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-TY.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-U3 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device @@ -967,7 +967,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-U3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-U3.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-VS # keys: fault.io.schizo @@ -983,7 +983,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-VS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-VS.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-W5 # keys: defect.io.pci.driver fault.io.schizo @@ -999,7 +999,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-W5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-W5.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8001-XP # keys: fault.io.pci.bus fault.io.schizo @@ -1015,7 +1015,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-XP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-XP.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8001-YA # keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo @@ -1031,7 +1031,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8001-YA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-YA.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-0R # keys: fault.io.pci.device fault.io.schizo @@ -1047,7 +1047,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-0R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-0R.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-14 # keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo @@ -1063,7 +1063,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-14.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-14.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-2Q # keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1079,7 +1079,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-2Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-2Q.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-3C # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1095,7 +1095,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-3C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-3C.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-4J # keys: fault.io.datapath fault.io.schizo @@ -1111,7 +1111,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-4J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-4J.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-5E # keys: defect.io.pci.driver fault.io.datapath fault.io.schizo @@ -1127,7 +1127,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-5E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-5E.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-6X # keys: fault.io.datapath fault.io.pci.bus fault.io.schizo @@ -1143,7 +1143,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-6X.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-6X.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-72 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo @@ -1159,7 +1159,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-72.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-72.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-8A # keys: fault.io.datapath fault.io.pci.device fault.io.schizo @@ -1175,7 +1175,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-8A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-8A.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-9P # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo @@ -1191,7 +1191,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-9P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-9P.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-A5 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1207,7 +1207,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-A5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-A5.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-CS # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1223,7 +1223,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-CS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-CS.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-D3 # keys: fault.io.hbus fault.io.schizo @@ -1239,7 +1239,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-D3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-D3.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-EY # keys: defect.io.pci.driver fault.io.hbus fault.io.schizo @@ -1255,7 +1255,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-EY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-EY.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-FD # keys: fault.io.hbus fault.io.pci.bus fault.io.schizo @@ -1271,7 +1271,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-FD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-FD.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-GH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo @@ -1287,7 +1287,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-GH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-GH.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-HC # keys: fault.io.hbus fault.io.pci.device fault.io.schizo @@ -1303,7 +1303,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-HC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-HC.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-JQ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo @@ -1319,7 +1319,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-JQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-JQ.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-K4 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1335,7 +1335,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-K4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-K4.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-LR # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1351,7 +1351,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-LR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-LR.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-M2 # keys: fault.io.datapath fault.io.hbus fault.io.schizo @@ -1367,7 +1367,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-M2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-M2.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-NX # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo @@ -1383,7 +1383,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-NX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-NX.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-PE # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo @@ -1399,7 +1399,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-PE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-PE.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-QJ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo @@ -1415,7 +1415,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-QJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-QJ.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-RS # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo @@ -1431,7 +1431,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-RS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-RS.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-S5 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo @@ -1447,7 +1447,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-S5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-S5.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-TP # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1463,7 +1463,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-TP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-TP.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-UA # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo @@ -1479,7 +1479,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-UA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-UA.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-VH # keys: fault.io.xmits @@ -1495,7 +1495,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-VH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-VH.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-WD # keys: defect.io.pci.driver fault.io.xmits @@ -1511,7 +1511,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-WD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-WD.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8002-XY # keys: fault.io.pci.bus fault.io.xmits @@ -1527,7 +1527,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-XY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-XY.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8002-Y3 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.xmits @@ -1543,7 +1543,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8002-Y3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-Y3.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-0Y # keys: fault.io.pci.device fault.io.xmits @@ -1559,7 +1559,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-0Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-0Y.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-13 # keys: defect.io.pci.driver fault.io.pci.device fault.io.xmits @@ -1575,7 +1575,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-13.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-13.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-2H # keys: fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1591,7 +1591,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-2H.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-2H.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-3D # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1607,7 +1607,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-3D.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-3D.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-4P # keys: fault.io.datapath fault.io.xmits @@ -1623,7 +1623,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-4P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-4P.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-5A # keys: defect.io.pci.driver fault.io.datapath fault.io.xmits @@ -1639,7 +1639,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-5A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-5A.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-6S # keys: fault.io.datapath fault.io.pci.bus fault.io.xmits @@ -1655,7 +1655,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-6S.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-6S.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-75 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.xmits @@ -1671,7 +1671,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-75.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-75.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-8E # keys: fault.io.datapath fault.io.pci.device fault.io.xmits @@ -1687,7 +1687,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-8E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-8E.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-9J # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.xmits @@ -1703,7 +1703,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-9J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-9J.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-A2 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1719,7 +1719,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-A2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-A2.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-CX # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1735,7 +1735,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-CX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-CX.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-D4 # keys: fault.io.hbus fault.io.xmits @@ -1751,7 +1751,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-D4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-D4.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-ER # keys: defect.io.pci.driver fault.io.hbus fault.io.xmits @@ -1767,7 +1767,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-ER.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-ER.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-FC # keys: fault.io.hbus fault.io.pci.bus fault.io.xmits @@ -1783,7 +1783,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-FC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-FC.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-GQ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.xmits @@ -1799,7 +1799,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-GQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-GQ.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-HD # keys: fault.io.hbus fault.io.pci.device fault.io.xmits @@ -1815,7 +1815,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-HD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-HD.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-JH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.xmits @@ -1831,7 +1831,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-JH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-JH.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-K3 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1847,7 +1847,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-K3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-K3.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-LY # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1863,7 +1863,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-LY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-LY.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-M5 # keys: fault.io.datapath fault.io.hbus fault.io.xmits @@ -1879,7 +1879,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-M5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-M5.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-NS # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.xmits @@ -1895,7 +1895,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-NS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-NS.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-PA # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits @@ -1911,7 +1911,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-PA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-PA.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-QP # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits @@ -1927,7 +1927,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-QP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-QP.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-RX # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits @@ -1943,7 +1943,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-RX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-RX.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-S2 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits @@ -1959,7 +1959,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-S2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-S2.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-TJ # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1975,7 +1975,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-TJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-TJ.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-UE # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits @@ -1991,7 +1991,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-UE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-UE.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-VQ # keys: fault.io.schizo fault.io.xmits @@ -2007,7 +2007,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-VQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-VQ.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-WC # keys: defect.io.pci.driver fault.io.schizo fault.io.xmits @@ -2023,7 +2023,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-WC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-WC.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8003-XR # keys: fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2039,7 +2039,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-XR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-XR.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8003-Y4 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2055,7 +2055,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8003-Y4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-Y4.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-0A # keys: fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2071,7 +2071,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-0A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-0A.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-1P # keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2087,7 +2087,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-1P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-1P.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-25 # keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2103,7 +2103,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-25.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-25.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-3S # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2119,7 +2119,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-3S.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-3S.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-43 # keys: fault.io.datapath fault.io.schizo fault.io.xmits @@ -2135,7 +2135,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-43.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-43.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-5Y # keys: defect.io.pci.driver fault.io.datapath fault.io.schizo fault.io.xmits @@ -2151,7 +2151,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-5Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-5Y.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-6D # keys: fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2167,7 +2167,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-6D.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-6D.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-7H # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2183,7 +2183,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-7H.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-7H.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-8R # keys: fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2199,7 +2199,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-8R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-8R.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-94 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2215,7 +2215,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-94.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-94.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-AQ # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2231,7 +2231,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-AQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-AQ.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-CC # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2247,7 +2247,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-CC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-CC.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-DJ # keys: fault.io.hbus fault.io.schizo fault.io.xmits @@ -2263,7 +2263,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-DJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-DJ.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-EE # keys: defect.io.pci.driver fault.io.hbus fault.io.schizo fault.io.xmits @@ -2279,7 +2279,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-EE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-EE.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-FX # keys: fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2295,7 +2295,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-FX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-FX.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-G2 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2311,7 +2311,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-G2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-G2.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-HS # keys: fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2327,7 +2327,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-HS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-HS.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-J5 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2343,7 +2343,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-J5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-J5.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-KP # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2359,7 +2359,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-KP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-KP.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-LA # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2375,7 +2375,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-LA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-LA.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-MH # keys: fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits @@ -2391,7 +2391,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-MH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-MH.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-ND # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits @@ -2407,7 +2407,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-ND.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-ND.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-PY # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2423,7 +2423,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-PY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-PY.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-Q3 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits @@ -2439,7 +2439,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-Q3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-Q3.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-RC # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2455,7 +2455,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-RC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-RC.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-SQ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2471,7 +2471,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-SQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-SQ.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-T4 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2487,7 +2487,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-T4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-T4.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-UR # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits @@ -2503,7 +2503,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-UR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-UR.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-V2 # keys: fault.io.psycho @@ -2519,7 +2519,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-V2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-V2.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-WX # keys: defect.io.pci.driver fault.io.psycho @@ -2535,7 +2535,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-WX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-WX.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8004-XE # keys: fault.io.datapath fault.io.psycho @@ -2551,7 +2551,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-XE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-XE.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8004-YJ # keys: defect.io.pci.driver fault.io.datapath fault.io.psycho @@ -2567,7 +2567,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8004-YJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-YJ.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-0E # keys: fault.io.hbus fault.io.psycho @@ -2583,7 +2583,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-0E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-0E.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-1J # keys: defect.io.pci.driver fault.io.hbus fault.io.psycho @@ -2599,7 +2599,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-1J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-1J.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-22 # keys: fault.io.datapath fault.io.hbus fault.io.psycho @@ -2615,7 +2615,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-22.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-22.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-3X # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.psycho @@ -2631,7 +2631,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-3X.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-3X.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-44 # keys: fault.io.pci.bus fault.io.psycho @@ -2647,7 +2647,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-44.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-44.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-5R # keys: defect.io.pci.driver fault.io.pci.bus fault.io.psycho @@ -2663,7 +2663,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-5R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-5R.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-6C # keys: fault.io.datapath fault.io.pci.bus fault.io.psycho @@ -2679,7 +2679,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-6C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-6C.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-7Q # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.psycho @@ -2695,7 +2695,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-7Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-7Q.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-8Y # keys: fault.io.hbus fault.io.pci.bus fault.io.psycho @@ -2711,7 +2711,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-8Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-8Y.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-93 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.psycho @@ -2727,7 +2727,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-93.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-93.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-AH # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho @@ -2743,7 +2743,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-AH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-AH.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-CD # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho @@ -2759,7 +2759,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-CD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-CD.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-DP # keys: fault.io.pci.device fault.io.psycho @@ -2775,7 +2775,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-DP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-DP.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-EA # keys: defect.io.pci.driver fault.io.pci.device fault.io.psycho @@ -2791,7 +2791,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-EA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-EA.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-FS # keys: fault.io.datapath fault.io.pci.device fault.io.psycho @@ -2807,7 +2807,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-FS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-FS.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-G5 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.psycho @@ -2823,7 +2823,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-G5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-G5.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-HX # keys: fault.io.hbus fault.io.pci.device fault.io.psycho @@ -2839,7 +2839,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-HX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-HX.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-J2 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.psycho @@ -2855,7 +2855,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-J2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-J2.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-KJ # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho @@ -2871,7 +2871,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-KJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-KJ.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-LE # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho @@ -2887,7 +2887,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-LE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-LE.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-MQ # keys: fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2903,7 +2903,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-MQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-MQ.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-NC # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2919,7 +2919,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-NC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-NC.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-PR # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2935,7 +2935,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-PR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-PR.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-Q4 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2951,7 +2951,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-Q4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-Q4.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-RD # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2967,7 +2967,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-RD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-RD.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-SH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2983,7 +2983,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-SH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-SH.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-T3 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -2999,7 +2999,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-T3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-T3.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-UY # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho @@ -3015,7 +3015,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-UY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-UY.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-V5 # keys: fault.io.tomatillo @@ -3031,7 +3031,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-V5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-V5.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-WS # keys: defect.io.pci.driver fault.io.tomatillo @@ -3047,7 +3047,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-WS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-WS.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8005-XA # keys: fault.io.datapath fault.io.tomatillo @@ -3063,7 +3063,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-XA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-XA.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8005-YP # keys: defect.io.pci.driver fault.io.datapath fault.io.tomatillo @@ -3079,7 +3079,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8005-YP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-YP.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-04 # keys: fault.io.hbus fault.io.tomatillo @@ -3095,7 +3095,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-04.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-04.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-1R # keys: defect.io.pci.driver fault.io.hbus fault.io.tomatillo @@ -3111,7 +3111,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-1R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-1R.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-2C # keys: fault.io.datapath fault.io.hbus fault.io.tomatillo @@ -3127,7 +3127,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-2C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-2C.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-3Q # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.tomatillo @@ -3143,7 +3143,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-3Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-3Q.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-4E # keys: fault.io.pci.bus fault.io.tomatillo @@ -3159,7 +3159,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-4E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-4E.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-5J # keys: defect.io.pci.driver fault.io.pci.bus fault.io.tomatillo @@ -3175,7 +3175,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-5J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-5J.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-62 # keys: fault.io.datapath fault.io.pci.bus fault.io.tomatillo @@ -3191,7 +3191,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-62.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-62.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-7X # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.tomatillo @@ -3207,7 +3207,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-7X.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-7X.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-8P # keys: fault.io.hbus fault.io.pci.bus fault.io.tomatillo @@ -3223,7 +3223,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-8P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-8P.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-9A # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.tomatillo @@ -3239,7 +3239,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-9A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-9A.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-AS # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo @@ -3255,7 +3255,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-AS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-AS.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-C5 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo @@ -3271,7 +3271,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-C5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-C5.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-DY # keys: fault.io.pci.device fault.io.tomatillo @@ -3287,7 +3287,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-DY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-DY.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-E3 # keys: defect.io.pci.driver fault.io.pci.device fault.io.tomatillo @@ -3303,7 +3303,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-E3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-E3.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-FH # keys: fault.io.datapath fault.io.pci.device fault.io.tomatillo @@ -3319,7 +3319,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-FH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-FH.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-GD # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.tomatillo @@ -3335,7 +3335,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-GD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-GD.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-HQ # keys: fault.io.hbus fault.io.pci.device fault.io.tomatillo @@ -3351,7 +3351,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-HQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-HQ.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-JC # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.tomatillo @@ -3367,7 +3367,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-JC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-JC.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-KR # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo @@ -3383,7 +3383,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-KR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-KR.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-L4 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo @@ -3399,7 +3399,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-L4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-L4.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-MX # keys: fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3415,7 +3415,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-MX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-MX.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-N2 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3431,7 +3431,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-N2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-N2.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-PJ # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3447,7 +3447,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-PJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-PJ.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-QE # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3463,7 +3463,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-QE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-QE.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-R5 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3479,7 +3479,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-R5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-R5.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-SS # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3495,7 +3495,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-SS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-SS.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-TA # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3511,7 +3511,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-TA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-TA.action" -msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" +msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nyour illumos distribution team for support.\n" # # code: SUN4U-8006-UP # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo @@ -3527,7 +3527,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8006-UP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-UP.action" -msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" +msgstr "\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is software, then consult\nyour illumos distribution team.\n" # # code: SUN4U-8006-VD # keys: fault.cpu.ultraSPARC-IIIiplus.dcache @@ -3703,7 +3703,7 @@ msgstr "This fault requires user and/or service interaction and currently does n msgid "SUN4U-8007-65.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8007-65.action" -msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support." # # code: SUN4U-8007-7S # keys: fault.cpu.SPARC64-VI.chip @@ -3767,7 +3767,7 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4U-8007-AX.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "SUN4U-8007-AX.action" -msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmdump -v -u <EVENT_ID> to identify the devices or contact Sun for support.\n" +msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmdump -v -u <EVENT_ID> to identify the devices or contact your illumos distribution team for support.\n" # # code: SUN4U-8007-C2 # keys: fault.cpu.SPARC64-VII.chip @@ -3825,7 +3825,7 @@ msgstr "Fault" msgid "SUN4U-8007-FQ.severity" msgstr "Minor" msgid "SUN4U-8007-FQ.description" -msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." +msgstr "The illumos Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." msgid "SUN4U-8007-FQ.response" msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n" msgid "SUN4U-8007-FQ.impact" @@ -3841,7 +3841,7 @@ msgstr "Fault" msgid "SUN4U-8007-GC.severity" msgstr "Minor" msgid "SUN4U-8007-GC.description" -msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." +msgstr "The illumos Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." msgid "SUN4U-8007-GC.response" msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n" msgid "SUN4U-8007-GC.impact" @@ -3857,7 +3857,7 @@ msgstr "Fault" msgid "SUN4U-8007-HH.severity" msgstr "Minor" msgid "SUN4U-8007-HH.description" -msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." +msgstr "The illumos Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." msgid "SUN4U-8007-HH.response" msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n" msgid "SUN4U-8007-HH.impact" @@ -3873,7 +3873,7 @@ msgstr "Fault" msgid "SUN4U-8007-JD.severity" msgstr "Minor" msgid "SUN4U-8007-JD.description" -msgstr "The Solaris Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." +msgstr "The illumos Fault Manager has determined that the\nnumber of correctable errors against a\nparticular CPU's cache index and way exceeds recommended\nlimts.\n Refer to %s for more information." msgid "SUN4U-8007-JD.response" msgstr "The system will attempt to remove the CPU's offending\ncache index and way from service.\n" msgid "SUN4U-8007-JD.impact" diff --git a/usr/src/cmd/fm/dicts/SUN4V.po b/usr/src/cmd/fm/dicts/SUN4V.po index 34da106f9c..39c9320a24 100644 --- a/usr/src/cmd/fm/dicts/SUN4V.po +++ b/usr/src/cmd/fm/dicts/SUN4V.po @@ -246,7 +246,7 @@ msgstr "No automated response.\n" msgid "SUN4V-8000-FJ.impact" msgstr "System performance may be impacted.\n" msgid "SUN4V-8000-FJ.action" -msgstr "At convenient time, try reseating the memory module(s). If problem persists,\ncontact Sun to schedule part replacement.\n" +msgstr "At a convenient time, try reseating the memory module(s). If the problem persists,\ncontact your hardware support team to schedule part replacement.\n" # # code: SUN4V-8000-GE # keys: fault.cpu.ultraSPARC-T2.ireg @@ -438,7 +438,7 @@ msgstr "No automated response.\n" msgid "SUN4V-8000-TC.impact" msgstr "System performance may be impacted.\n" msgid "SUN4V-8000-TC.action" -msgstr "At convenient time, try reseating the memory module. If problem persists,\ncontact Sun to schedule part replacement.\n" +msgstr "At a convenient time, try reseating the memory module. If the problem persists,\ncontact your hardware support team to schedule part replacement.\n" # # code: SUN4V-8000-UQ # keys: fault.cpu.ultraSPARC-T2.l2data-u @@ -498,7 +498,7 @@ msgstr "Major" msgid "SUN4V-8000-X2.description" msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n Refer to %s for more information." msgid "SUN4V-8000-X2.response" -msgstr "Error reports from the affected components will be logged for examination by Sun.\n" +msgstr "Error reports from the affected components will be logged for examination by your illumos distribution team.\n" msgid "SUN4V-8000-X2.impact" msgstr "System performance and stability may be affected. \n" msgid "SUN4V-8000-X2.action" @@ -518,7 +518,7 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4V-8000-YX.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "SUN4V-8000-YX.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your hardware support team for support.\n" # # code: SUN4V-8001-02 # keys: fault.io.n2.dmu @@ -534,7 +534,7 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4V-8001-02.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "SUN4V-8001-02.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: SUN4V-8001-1X # keys: fault.io.n2.niu @@ -550,7 +550,7 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4V-8001-1X.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "SUN4V-8001-1X.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: SUN4V-8001-2E # keys: fault.io.n2.siu @@ -566,7 +566,7 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4V-8001-2E.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "SUN4V-8001-2E.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: SUN4V-8001-3J # keys: fault.io.n2.soc @@ -582,7 +582,7 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4V-8001-3J.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "SUN4V-8001-3J.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: SUN4V-8001-4C # keys: fault.io.n2.crossbar @@ -598,7 +598,7 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4V-8001-4C.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "SUN4V-8001-4C.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: SUN4V-8001-5Q # keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch @@ -614,7 +614,7 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4V-8001-5Q.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "SUN4V-8001-5Q.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: SUN4V-8001-64 # keys: fault.io.vf.ncx @@ -630,7 +630,7 @@ msgstr "One or more device instances may be disabled\n" msgid "SUN4V-8001-64.impact" msgstr "Loss of services provided by the device\ninstances associated with this fault\n" msgid "SUN4V-8001-64.action" -msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" +msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact your illumos distribution team for support.\n" # # code: SUN4V-8001-7R # keys: fault.memory.link-f @@ -646,7 +646,7 @@ msgstr "No automated response.\n" msgid "SUN4V-8001-7R.impact" msgstr "System performance may be impacted.\n" msgid "SUN4V-8001-7R.action" -msgstr "At convenient time, try reseating the memory module(s). If problem persists,\ncontact Sun to schedule part replacement.\n" +msgstr "At a convenient time, try reseating the memory module(s). If the problem persists,\ncontact your hardware support team to schedule part replacement.\n" # # code: SUN4V-8001-8H # keys: fault.cpu.ultraSPARC-T2plus.ireg @@ -1478,4 +1478,4 @@ msgstr "No automated response.\n" msgid "SUN4V-8002-US.impact" msgstr "Some services such as Fault Diagnosis may be degraded as a result.\n" msgid "SUN4V-8002-US.action" -msgstr "Schedule a repair procedure for the Service Processor, or contact Sun for support.\n" +msgstr "Schedule a repair procedure for the Service Processor, or contact your illumos distribution team for support.\n" diff --git a/usr/src/cmd/fm/dicts/SUNOS.po b/usr/src/cmd/fm/dicts/SUNOS.po index 5d37f79281..caccdfc1b3 100644 --- a/usr/src/cmd/fm/dicts/SUNOS.po +++ b/usr/src/cmd/fm/dicts/SUNOS.po @@ -34,7 +34,7 @@ msgstr "Major" msgid "SUNOS-8000-0G.description" msgstr "Errors have been detected that require a reboot to ensure system integrity. Refer to %s for more information." msgid "SUNOS-8000-0G.response" -msgstr "Solaris will attempt to save and diagnose the error telemetry" +msgstr "illumos will attempt to save and diagnose the error telemetry" msgid "SUNOS-8000-0G.impact" msgstr "The system will sync files, save a crash dump if needed, and reboot" msgid "SUNOS-8000-0G.action" @@ -50,11 +50,11 @@ msgstr "Minor" msgid "SUNOS-8000-1L.description" msgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis. Refer to %s for more information." msgid "SUNOS-8000-1L.response" -msgstr "Error reports from the component will be logged for examination by Sun." +msgstr "Error reports from the component will be logged for examination by your illumos distribution team." msgid "SUNOS-8000-1L.impact" msgstr "Automated diagnosis and response for these events will not occur." msgid "SUNOS-8000-1L.action" -msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support." +msgstr "Ensure that fault management software is installed properly. Contact your illumos distribution team for support." # # code: SUNOS-8000-20 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus fault.io.pci.device @@ -70,7 +70,7 @@ msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-20.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-20.action" -msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support." # # code: SUNOS-8000-3V # keys: defect.Deprecated fault.io.pci.bus fault.io.pci.device @@ -86,7 +86,7 @@ msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-3V.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-3V.action" -msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." +msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support." # # code: SUNOS-8000-46 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.device @@ -102,7 +102,7 @@ msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-46.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-46.action" -msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support." # # code: SUNOS-8000-5T # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus @@ -118,7 +118,7 @@ msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-5T.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-5T.action" -msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." +msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact your illumos distribution team for support." # # code: SUNOS-8000-69 # keys: defect.Deprecated fault.io.pci.device @@ -134,7 +134,7 @@ msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-69.impact" msgstr "Loss of services provided by the device instances associated with this fault." msgid "SUNOS-8000-69.action" -msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." +msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support." # # code: SUNOS-8000-7N # keys: defect.Deprecated fault.io.pci.bus @@ -150,7 +150,7 @@ msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-7N.impact" msgstr "Loss of services provided by the device instances associated with this fault." msgid "SUNOS-8000-7N.action" -msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." +msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact your illumos distribution team for support." # # code: SUNOS-8000-8W # keys: defect.Deprecated defect.io.pci.driver @@ -166,7 +166,7 @@ msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-8W.impact" msgstr "Loss of services provided by the device instances associated with this fault." msgid "SUNOS-8000-8W.action" -msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." +msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact your illumos distribution team for support." # # code: SUNOS-8000-91 # keys: defect.sunos.zones.upgrade @@ -176,13 +176,13 @@ msgstr "Defect" msgid "SUNOS-8000-91.severity" msgstr "Minor" msgid "SUNOS-8000-91.description" -msgstr "\n The Solaris system or boot environment that is being upgraded\n has non-global zones installed. The current version of Live\n Upgrade cannot upgrade a boot environment that has non-global\n zones installed.\n Refer to %s for more information." +msgstr "\n The illumos system or boot environment that is being upgraded\n has non-global zones installed. The current version of Live\n Upgrade cannot upgrade a boot environment that has non-global\n zones installed.\n Refer to %s for more information." msgid "SUNOS-8000-91.response" msgstr "The upgrade procedure has been terminated." msgid "SUNOS-8000-91.impact" -msgstr "The Solaris system or boot environment is not upgraded." +msgstr "The illumos system or boot environment is not upgraded." msgid "SUNOS-8000-91.action" -msgstr "\n Evaluate each of the choices below and select the one that is\n best for your needs. Contact Sun for support.\n " +msgstr "\n Evaluate each of the choices below and select the one that is\n best for your needs. Contact your illumos distribution team for support.\n " # # code: SUNOS-8000-AK # keys: ereport.sunos.boot.upgrade.menu_lst @@ -192,7 +192,7 @@ msgstr "Error" msgid "SUNOS-8000-AK.severity" msgstr "Critical" msgid "SUNOS-8000-AK.description" -msgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n Refer to %s for more information." +msgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n Refer to %s for more information." msgid "SUNOS-8000-AK.response" msgstr "No automated response." msgid "SUNOS-8000-AK.impact" @@ -208,7 +208,7 @@ msgstr "Error" msgid "SUNOS-8000-CF.severity" msgstr "Critical" msgid "SUNOS-8000-CF.description" -msgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n Refer to %s for more information." +msgstr "illumos could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n Refer to %s for more information." msgid "SUNOS-8000-CF.response" msgstr "No automated response." msgid "SUNOS-8000-CF.impact" @@ -242,7 +242,7 @@ msgstr "Minor" msgid "SUNOS-8000-E8.description" msgstr "The diagnosis engine encountered an error while resuming diagnosis. Refer to %s for more information." msgid "SUNOS-8000-E8.response" -msgstr "Error reports have been logged for examination by Sun." +msgstr "Error reports have been logged for examination by your illumos distribution team." msgid "SUNOS-8000-E8.impact" msgstr "Automated diagnosis and response for these events will not occur." msgid "SUNOS-8000-E8.action" @@ -258,11 +258,11 @@ msgstr "Major" msgid "SUNOS-8000-FU.description" msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis. Refer to %s for more information." msgid "SUNOS-8000-FU.response" -msgstr "Error reports have been logged for examination by Sun." +msgstr "Error reports have been logged for examination by your illumos distribution team." msgid "SUNOS-8000-FU.impact" msgstr "Automated diagnosis and response for these events will not occur." msgid "SUNOS-8000-FU.action" -msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed." +msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed." # # code: SUNOS-8000-G7 # keys: defect.sunos.eft.undiag.limit @@ -274,7 +274,7 @@ msgstr "Minor" msgid "SUNOS-8000-G7.description" msgstr "The diagnosis engine hit a limit restriction and was unable to perform a diagnosis. Refer to %s for more information." msgid "SUNOS-8000-G7.response" -msgstr "Error reports have been logged for examination by Sun." +msgstr "Error reports have been logged for examination by your illumos distribution team." msgid "SUNOS-8000-G7.impact" msgstr "Automated diagnosis and response for these events will not occur." msgid "SUNOS-8000-G7.action" @@ -290,11 +290,11 @@ msgstr "Minor" msgid "SUNOS-8000-HV.description" msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis. Refer to %s for more information." msgid "SUNOS-8000-HV.response" -msgstr "Error reports have been logged for examination by Sun." +msgstr "Error reports have been logged for examination by your illumos distribution team." msgid "SUNOS-8000-HV.impact" msgstr "Automated diagnosis and response for these events will not occur." msgid "SUNOS-8000-HV.action" -msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed." +msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed." # # code: SUNOS-8000-J0 # keys: defect.sunos.eft.unexpected_telemetry fault.sunos.eft.unexpected_telemetry @@ -306,11 +306,11 @@ msgstr "Major" msgid "SUNOS-8000-J0.description" msgstr "The diagnosis engine encountered telemetry from the listed devices for which it was unable to perform a diagnosis - %.\n Refer to %s for more information. Refer to %s for more information." msgid "SUNOS-8000-J0.response" -msgstr "Error reports have been logged for examination by Sun.\n" +msgstr "Error reports have been logged for examination by your illumos distribution team.\n" msgid "SUNOS-8000-J0.impact" msgstr "Automated diagnosis and response for these events will not occur.\n" msgid "SUNOS-8000-J0.action" -msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed.\n" +msgstr "Ensure that the latest illumos Kernel and Predictive Self-Healing (PSH) updates are installed.\n" # # code: SUNOS-8000-KL # keys: defect.sunos.kernel.panic diff --git a/usr/src/cmd/fm/dicts/ZFS.po b/usr/src/cmd/fm/dicts/ZFS.po index 30130ca985..91ce789c2e 100644 --- a/usr/src/cmd/fm/dicts/ZFS.po +++ b/usr/src/cmd/fm/dicts/ZFS.po @@ -151,7 +151,7 @@ msgstr "No automated response will be taken." msgid "ZFS-8000-8A.impact" msgstr "The file or directory is unavailable." msgid "ZFS-8000-8A.action" -msgstr "\nRun 'zpool status -x' to determine which pool is damaged:\n\n\n# zpool status -x\n pool: test\n state: ONLINE\nstatus: One or more devices has experienced an error and no valid replicas\n are available. Some filesystem data is corrupt, and applications\n may have been affected.\naction: Destroy the pool and restore from backup.\n see: http://illumos.org/msg/ZFS-8000-8A\n scrub: none requested\nconfig:\n\n NAME STATE READ WRITE CKSUM\n test ONLINE 0 0 2\n c0t0d0 ONLINE 0 0 2\n c0t0d1 ONLINE 0 0 0\n\nerrors: 1 data errors, use '-v' for a list\n\n\nUnfortunately, the data cannot be repaired, and the only choice to\nrepair the data is to restore the pool from backup. Applications attempting to\naccess the corrupted data will get an error (EIO), and data may be permanently\nlost.\n\nOn recent versions of Solaris, the list of affected files can be\nretrieved by using the '-v' option to 'zpool status':\n\n\n# zpool status -xv\n pool: test\n state: ONLINE\nstatus: One or more devices has experienced an error and no valid replicas\n are available. Some filesystem data is corrupt, and applications\n may have been affected.\naction: Destroy the pool and restore from backup.\n see: http://illumos.org/msg/ZFS-8000-8A\n scrub: none requested\nconfig:\n\n NAME STATE READ WRITE CKSUM\n test ONLINE 0 0 2\n c0t0d0 ONLINE 0 0 2\n c0t0d1 ONLINE 0 0 0\n\nerrors: Permanent errors have been detected in the following files:\n\n /export/example/foo\n\n\nDamaged files may or may not be able to be removed depending on the\ntype of corruption. If the corruption is within the plain data, the file should\nbe removable. If the corruption is in the file metadata, then the file cannot\nbe removed, though it can be moved to an alternate location. In either case,\nthe data should be restored from a backup source. It is also possible for the\ncorruption to be within pool-wide metadata, resulting in entire datasets being\nunavailable. If this is the case, the only option is to destroy the pool and\nre-create the datasets from backup.\n " +msgstr "\nRun 'zpool status -x' to determine which pool is damaged:\n\n\n# zpool status -x\n pool: test\n state: ONLINE\nstatus: One or more devices has experienced an error and no valid replicas\n are available. Some filesystem data is corrupt, and applications\n may have been affected.\naction: Destroy the pool and restore from backup.\n see: http://illumos.org/msg/ZFS-8000-8A\n scrub: none requested\nconfig:\n\n NAME STATE READ WRITE CKSUM\n test ONLINE 0 0 2\n c0t0d0 ONLINE 0 0 2\n c0t0d1 ONLINE 0 0 0\n\nerrors: 1 data errors, use '-v' for a list\n\n\nUnfortunately, the data cannot be repaired, and the only choice to\nrepair the data is to restore the pool from backup. Applications attempting to\naccess the corrupted data will get an error (EIO), and data may be permanently\nlost.\n\nOn recent versions of illumos, the list of affected files can be\nretrieved by using the '-v' option to 'zpool status':\n\n\n# zpool status -xv\n pool: test\n state: ONLINE\nstatus: One or more devices has experienced an error and no valid replicas\n are available. Some filesystem data is corrupt, and applications\n may have been affected.\naction: Destroy the pool and restore from backup.\n see: http://illumos.org/msg/ZFS-8000-8A\n scrub: none requested\nconfig:\n\n NAME STATE READ WRITE CKSUM\n test ONLINE 0 0 2\n c0t0d0 ONLINE 0 0 2\n c0t0d1 ONLINE 0 0 0\n\nerrors: Permanent errors have been detected in the following files:\n\n /export/example/foo\n\n\nDamaged files may or may not be able to be removed depending on the\ntype of corruption. If the corruption is within the plain data, the file should\nbe removable. If the corruption is in the file metadata, then the file cannot\nbe removed, though it can be moved to an alternate location. In either case,\nthe data should be restored from a backup source. It is also possible for the\ncorruption to be within pool-wide metadata, resulting in entire datasets being\nunavailable. If this is the case, the only option is to destroy the pool and\nre-create the datasets from backup.\n " # # code: ZFS-8000-9P # keys: ereport.fs.zfs.device.failing |
