summaryrefslogtreecommitdiff
path: root/sysutils/apcupsd/patches/patch-ab
blob: 8ca75a7cbeae75b83ab2e3682a558aac2bc7d36b (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
$NetBSD: patch-ab,v 1.5 2007/06/15 19:05:56 bouyer Exp $

--- examples/apcupsd.master.conf.orig	2002-05-28 15:34:19.000000000 +0200
+++ examples/apcupsd.master.conf	2007-06-15 17:12:48.000000000 +0200
@@ -1,78 +1,120 @@
 ## apcupsd.conf v1.1 ##
-# 
-#  for apcupsd release 3.8.0
-#
-# "apcupsd" POSIX config file
-#
-#  If you have used a prior version of apcupsd, the CONTROL script file
-#  (/sbin/powersc) has now been replaced by /etc/apcupsd/apccontrol.
-#  Consequently, the CONTROL configuration statement is obsolete.
-#  The following configuration statements have been replaced by scripts
-#  called from /etc/apcupsd/apccontrol, and thus are obsolete:
-#  BATTCMD, LIMITCMN, LOADCMD, PWRCMD, REBOOTCMD, REMOTECMD, RETCMD,
-#  and TIMECMD. 
 #
+#  for apcupsd release 3.10.6 (10 October 2003) - freebsd
 #
+# "apcupsd" POSIX config file
 #
 # ========= General configuration parameters ============
 #
+# UPSNAME xxx
+#   Use this to give your UPS a name in log files and such. This
+#   is particulary useful if you have multiple UPSes.  This does not
+#   set the EEPROM.
+#UPSNAME
+#
 # UPSCABLE [ simple | smart |
-#            940-00(20B,23A,24B,24C,24G,95A,95B,95C) |
+#            940-00(20B,20C,23A,24B,24C,24G,95A,95B,95C) |
 #            940-15(24C) |
-#            ether ]
+#            ether, usb ]
 # defines the type of cable that you have.
 UPSCABLE smart
 #
+# Old types, still valid, are mapped to the new generic drives
+#   automatically
 # UPSTYPE [ backups | sharebasic | netups |
 #           backupspro | smartvsups |
 #           newbackupspro | backupspropnp |
 #           smartups | matrixups | sharesmart ]
+#
+# *** NEW TYPES FOR GENERIC DRIVERS ***
+# UPSTYPE [ dumb | apcsmart | net | usb | snmp | test]
 # defines the type of UPS you have.
 UPSTYPE smartups
 #
 #
 #DEVICE <string> /dev/<serial port>
-# name of your serial port
-DEVICE /dev/ttyS0
+# name of your UPS device
+#
+# Here a table of the possible devices related with the UPS drivers.
+#
+#   NOTE!!! for USB devices, please use a form indicated below
+#      including the [0-15] as written!
+#
+# Driver   Device                    Description
+# dumb     /dev/tty**                Serial character device
+# apcsmart /dev/tty**                Serial character device
+# usb      /dev/usb/hid/hiddev[0-15] If you follow our naming scheme
+# usb      /dev/usb/hiddev[0-15]      On some systems
+# net      hostname:port             Network link to a master apcupsd
+#                                    through NIS
+# snmp     hostname:port:vendor:community
+#                                    SNMP Network link to an SNMP-enabled
+#                                    UPS device. Vendor is the MIB used by
+#                                    the UPS device: can be "APC" or "RFC"
+#                                    where APC is the powernet MIB and RFC
+#                                    is the IETF's rfc1628 UPS-MIB.
+#                                    Port is usually 161.
+DEVICE /dev/tty01
 #
 #LOCKFILE <path to lockfile>
 # path for serial port lock file
-LOCKFILE /var/lock
+LOCKFILE /var/spool/lock
 #
 #
 #
 # ======== configuration parameters used during power failures ==========
 #
-# BATTERYLEVEL <percent of battery charge for shutdown> 10
+# Note: BATTERYLEVEL, MINUTES, and TIMEOUT work in conjunction, so
+# the first that occurs will cause the initation of a shutdown.
+#
+# If during a power failure, the remaining battery percentage
+# (as reported by the UPS) is below or equal to BATTERYLEVEL,
+# apcupsd will initiate a system shutdown.
 BATTERYLEVEL 5
 #
-# MINUTES <time in minutes of remaining battery runtime before shutdown> 5
+#
+# If during a power failure, the remaining runtime in minutes
+# (as calculated internally by the UPS) is below or equal to MINUTES,
+# apcupsd, will initiate a system shutdown.
 MINUTES 3
 #
-# TIMEOUT <time is seconds to run on UPS after a power failure>
+#
+# If during a power failure, the UPS has run on batteries for TIMEOUT
+# many seconds or longer, apcupsd will initiate a system shutdown.
+# A value of 0 disables this timer.
+#
 #  Note, if you have a Smart UPS, you will most likely want to disable
 #    this timer by setting it to zero. That way, you UPS will continue
-#    on batteries until either the % charge remaing drops below BATTERYLEVEL,
-#    or the remaining battery runtime drops below MINUTES.  Of course,
+#    on batteries until either the % charge remaing drops to or below BATTERYLEVEL,
+#    or the remaining battery runtime drops to or below MINUTES.  Of course,
 #    if you are testing, setting this to 60 causes a quick system shutdown
-#    if you pull the power plug.   
+#    if you pull the power plug.
 #  If you have an older dumb UPS, you will want to set this to less than
 #    the time you know you can run on batteries.
 TIMEOUT 0
-
 #
-# ANNOY <int> <30> <0> disables
+#
 #  Time in seconds between annoying users to signoff prior to
-#  system shutdown.
+#  system shutdown. 0 disables.
 ANNOY 300
 #
-# ANNOYDELAY <int> <60> <0> disables delay before annoying user
+# Initial delay after power failure before warning users to get
+# off the system.
 ANNOYDELAY 60
 #
+# The condition which determines when users are prevented from
+# logging in during a power failure.
 # NOLOGON <string> [ disable | timeout | percent | minutes | always ]
 NOLOGON disable
 #
 #
+# If killdelay is set, apcupsd will continue running after a
+# shutdown has been requested, and after the specified time in
+# seconds attempt to kill the power.  This is for use on systems
+# where apcupsd cannot regain control after a shutdown.
+# KILLDELAY <seconds>  0 disables
+KILLDELAY 0
+#
 #
 # ==== Configuration statements the network information server =========
 #
@@ -80,83 +122,149 @@
 #  information server. If netstatus is on, a network information
 #  server process will be started for serving the STATUS and
 #  EVENT data over the network (used by CGI programs).
-NETSERVER on
+NETSERVER off
 #
-# SERVERPORT <port> default is 7000
+# NISIP <dotted notation ip address>
+#  IP address on which NIS server will listen for incoming connections.
+#  Default value is 0.0.0.0 that means any incoming request will be
+#  serviced but if you want it to listen to a single subnet you can
+#  set it up to that subnet address, for example 192.168.10.0
+#  Additionally you can listen for a single IP like 192.168.10.1
+NISIP 0.0.0.0
+#
+# NISPORT <port> default is 3551 as registered with the IANA
 #  port to use for sending STATUS and EVENTS data over the network.
 #  It is not used unless NETSERVER is on. If you change this port,
 #  you will need to change the corresponding value in the cgi directory
 #  and rebuild the cgi programs.
-SERVERPORT 7000
+NISPORT 3551
 #
 # If you want the last few EVENTS to be available over the network
 # by the network information server, you must define an EVENTSFILE.
-EVENTSFILE /etc/apcupsd/apcupsd.events
+EVENTSFILE /var/log/apcupsd.events
 #
+# EVENTSFILEMAX <kilobytes>
+#  By default, the size of the EVENTSFILE will be not be allowed to exceed
+#  10 kilobytes.  When the file grows beyond this limit, older EVENTS will
+#  be removed from the beginning of the file (first in first out).  The
+#  parameter EVENTSFILEMAX can be set to a different kilobyte value, or set
+#  to zero to allow the EVENTSFILE to grow without limit.
+EVENTSFILEMAX 10
 #
+# ========== Configuration statements used if sharing =============
+#            a UPS and controlling it via the network
 #
+#      The configuration statements below are used if you
+#      want to share one UPS to power multiple machines and have them
+#      communicate by the network. Obviously, the master is connected
+#      to the UPS via the serial cable, and it communicates to the
+#      "slaves" via the network -- i.e. the slaves get their info
+#      concerning the UPS via the ethernet.
+#
+# UPSCLASS [ standalone | shareslave | sharemaster | netslave | netmaster ]
+# normally standalone unless you share a UPS with multiple machines.
+UPSCLASS standalone
+#
+# Unless you want to share the UPS (power multiple machines).
+#  this should be disable
+# UPSMODE [ disable | share | net | sharenet ]
+UPSMODE disable
 #
 # ===== Configuration statements to control apcupsd system logging ========
 #
-# STATTIME <int> <120> <0> disables <update rate in seconds for status file >
+# Time interval in seconds between writing the STATUS file; 0 disables
 STATTIME 0
 #
-# STATFILE
-STATFILE /etc/apcupsd/apcupsd.status
+# Location of STATUS file (written to only if STATTIME is non-zero)
+STATFILE /var/run/apcupsd.status
 #
 #
 # LOGSTATS [ on | off ] on enables, off disables
-# Note! This generates a lot of output, so if         
+# Note! This generates a lot of output, so if
 #       you turn this on, be sure that the
 #       file defined in syslog.conf for LOG_NOTICE is a named pipe.
+#  You probably do not want this on.
 LOGSTATS off
 #
 #
-# DATATIME <int> <120> <0> disables <update rate in seconds for data logging >
+# Time interval in seconds between writing the DATA records to
+#   the log file. 0 disables.
 DATATIME 0
 #
-# FACILITY defines the logging facility (class) for logging to syslog. 
-#          If not specified, it defaults to "daemon". This is useful 
+# FACILITY defines the logging facility (class) for logging to syslog.
+#          If not specified, it defaults to "daemon". This is useful
 #          if you want to separate the data logged by apcupsd from other
 #          programs.
-#FACILITY local0
+#FACILITY DAEMON
 #
 #
 #
 #
+# ========== Configuration statements used in updating the UPS EPROM =========
 #
-# ========== Configuration statements used if sharing =============
-#            a UPS and controlling it via the network              
+# UPS name, max 8 characters  -- used only during -n or --rename-ups
+UPSNAME LK-SMART
 #
-#      The configuration statements below are used if you
-#      want to share one UPS for multiple machines and have them
-#      communicate by the network.
+# Battery date - 8 characters -- used only during -u or --update-battery-date
+BATTDATE 11/20/01
 #
-# UPSCLASS [ standalone | shareslave | sharemaster | netslave | netmaster ]
-# normally standalone unless you share a UPS with multiple machines.
-UPSCLASS netmaster
+#  The following items are set during -c or --configure
 #
-# Unless you want to share the UPS (power multiple machines).
-#  this should be disable
-# UPSMODE [ disable | share | net | sharenet ]
-UPSMODE net
+# Sensitivity to line voltage quality (H cause faster transfer to batteries)
+# SENSITIVITY H M L        (default = H)
+#SENSITIVITY H
+#
+# UPS delay after power return (seconds)
+# WAKEUP 000 060 180 300   (default = 0)
+WAKEUP 60
+#
+# UPS Grace period after request to power off (seconds)
+# SLEEP 020 180 300 600    (default = 20)
+SLEEP 180
+#
+#
+# Low line voltage causing transfer to batteries
+# The permitted values depend on your model as defined by last letter
+#  of FIRMWARE or APCMODEL. Some representative values are:
+#    D 106 103 100 097
+#    M 177 172 168 182
+#    A 092 090 088 086
+#    I 208 204 200 196     (default = 0 => not valid)
+LOTRANSFER  208
+#
+# High line voltage causing transfer to batteries
+# The permitted values depend on your model as defined by last letter
+#  of FIRMWARE or APCMODEL. Some representative values are:
+#    D 127 130 133 136
+#    M 229 234 239 224
+#    A 108 110 112 114
+#    I 253 257 261 265     (default = 0 => not valid)
+HITRANSFER 253
 #
-#NETACCESS <string> [ true | false ] Enable Network Access Support
-NETACCESS true
+# Battery change needed to restore power
+# RETURNCHARGE 00 15 50 90 (default = 15)
+#RETURNCHARGE 15
 #
-# NETTIME <int>
-NETTIME 10
+# Alarm delay
+# 0 = zero delay after pwr fail, T = power fail + 30 sec, L = low battery, N = never
+# BEEPSTATE 0 T L N        (default = 0)
+BEEPSTATE 0
 #
-# NETPORT <int>
-NETPORT 6666
+# Low battery warning delay in minutes
+# LOWBATT 02 05 07 10      (default = 02)
+#LOWBATT 2
 #
-# MASTER <string>
-#MASTER
+# UPS Output voltage when running on batteries
+# The permitted values depend on your model as defined by last letter
+#  of FIRMWARE or APCMODEL. Some representative values are:
+#    D 115
+#    M 208
+#    A 100
+#    I 230 240 220 225     (default = 0 => not valid)
+OUTPUTVOLTS 230
 #
-# SLAVE <string>
-SLAVE my.network.slave.com
+# Self test interval in hours 336=2 weeks, 168=1 week, ON=at power on
+# SELFTEST 336 168 ON OFF  (default = 336)
+SELFTEST 168
 #
-# Note, USERMAGIC is only used by a slave, not here
-# USERMAGIC <string>
-#USERMAGIC
 #