summaryrefslogtreecommitdiff
path: root/mibs/TUNNEL-MIB.txt
diff options
context:
space:
mode:
Diffstat (limited to 'mibs/TUNNEL-MIB.txt')
-rw-r--r--mibs/TUNNEL-MIB.txt738
1 files changed, 738 insertions, 0 deletions
diff --git a/mibs/TUNNEL-MIB.txt b/mibs/TUNNEL-MIB.txt
new file mode 100644
index 0000000..5f9596b
--- /dev/null
+++ b/mibs/TUNNEL-MIB.txt
@@ -0,0 +1,738 @@
+TUNNEL-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ MODULE-IDENTITY, OBJECT-TYPE, transmission,
+ Integer32, IpAddress FROM SNMPv2-SMI -- [RFC2578]
+
+ RowStatus, StorageType FROM SNMPv2-TC -- [RFC2579]
+
+ MODULE-COMPLIANCE,
+ OBJECT-GROUP FROM SNMPv2-CONF -- [RFC2580]
+
+ InetAddressType,
+ InetAddress FROM INET-ADDRESS-MIB -- [RFC4001]
+
+ IPv6FlowLabelOrAny FROM IPV6-FLOW-LABEL-MIB -- [RFC3595]
+
+ ifIndex,
+ InterfaceIndexOrZero FROM IF-MIB -- [RFC2863]
+
+ IANAtunnelType FROM IANAifType-MIB; -- [IFTYPE]
+
+tunnelMIB MODULE-IDENTITY
+ LAST-UPDATED "200505160000Z" -- May 16, 2005
+ ORGANIZATION "IETF IP Version 6 (IPv6) Working Group"
+ CONTACT-INFO
+ " Dave Thaler
+ Microsoft Corporation
+ One Microsoft Way
+ Redmond, WA 98052-6399
+ EMail: dthaler@microsoft.com"
+ DESCRIPTION
+ "The MIB module for management of IP Tunnels,
+ independent of the specific encapsulation scheme in
+ use.
+
+ Copyright (C) The Internet Society (2005). This
+ version of this MIB module is part of RFC 4087; see
+ the RFC itself for full legal notices."
+
+ REVISION "200505160000Z" -- May 16, 2005
+ DESCRIPTION
+ "IPv4-specific objects were deprecated, including
+ tunnelIfLocalAddress, tunnelIfRemoteAddress, the
+ tunnelConfigTable, and the tunnelMIBBasicGroup.
+
+ Added IP version-agnostic objects that should be used
+ instead, including tunnelIfAddressType,
+ tunnelIfLocalInetAddress, tunnelIfRemoteInetAddress,
+ the tunnelInetConfigTable, and the
+ tunnelIMIBInetGroup.
+
+ The new tunnelIfLocalInetAddress and
+ tunnelIfRemoteInetAddress objects are read-write,
+ rather than read-only.
+
+ Updated DESCRIPTION clauses of existing version-
+ agnostic objects (e.g., tunnelIfTOS) that contained
+ IPv4-specific text to cover IPv6 as well.
+
+ Added tunnelIfFlowLabel for tunnels over IPv6.
+
+ The encapsulation method was previously an INTEGER
+ type, and is now an IANA-maintained textual
+ convention.
+
+ Published as RFC 4087."
+ REVISION "199908241200Z" -- August 24, 1999
+ DESCRIPTION
+ "Initial version, published as RFC 2667."
+ ::= { transmission 131 }
+
+tunnelMIBObjects OBJECT IDENTIFIER ::= { tunnelMIB 1 }
+
+tunnel OBJECT IDENTIFIER ::= { tunnelMIBObjects 1 }
+
+-- the IP Tunnel MIB-Group
+--
+-- a collection of objects providing information about
+-- IP Tunnels
+
+tunnelIfTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TunnelIfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The (conceptual) table containing information on
+ configured tunnels."
+ ::= { tunnel 1 }
+
+tunnelIfEntry OBJECT-TYPE
+ SYNTAX TunnelIfEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry (conceptual row) containing the information
+ on a particular configured tunnel."
+ INDEX { ifIndex }
+ ::= { tunnelIfTable 1 }
+
+TunnelIfEntry ::= SEQUENCE {
+ tunnelIfLocalAddress IpAddress, -- deprecated
+ tunnelIfRemoteAddress IpAddress, -- deprecated
+ tunnelIfEncapsMethod IANAtunnelType,
+ tunnelIfHopLimit Integer32,
+ tunnelIfSecurity INTEGER,
+ tunnelIfTOS Integer32,
+ tunnelIfFlowLabel IPv6FlowLabelOrAny,
+ tunnelIfAddressType InetAddressType,
+ tunnelIfLocalInetAddress InetAddress,
+ tunnelIfRemoteInetAddress InetAddress,
+ tunnelIfEncapsLimit Integer32
+}
+
+tunnelIfLocalAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The address of the local endpoint of the tunnel
+ (i.e., the source address used in the outer IP
+ header), or 0.0.0.0 if unknown or if the tunnel is
+ over IPv6.
+
+ Since this object does not support IPv6, it is
+ deprecated in favor of tunnelIfLocalInetAddress."
+ ::= { tunnelIfEntry 1 }
+
+tunnelIfRemoteAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "The address of the remote endpoint of the tunnel
+ (i.e., the destination address used in the outer IP
+ header), or 0.0.0.0 if unknown, or an IPv6 address, or
+
+ the tunnel is not a point-to-point link (e.g., if it
+ is a 6to4 tunnel).
+
+ Since this object does not support IPv6, it is
+ deprecated in favor of tunnelIfRemoteInetAddress."
+ ::= { tunnelIfEntry 2 }
+
+tunnelIfEncapsMethod OBJECT-TYPE
+ SYNTAX IANAtunnelType
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The encapsulation method used by the tunnel."
+ ::= { tunnelIfEntry 3 }
+
+tunnelIfHopLimit OBJECT-TYPE
+ SYNTAX Integer32 (0 | 1..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The IPv4 TTL or IPv6 Hop Limit to use in the outer IP
+ header. A value of 0 indicates that the value is
+ copied from the payload's header."
+ ::= { tunnelIfEntry 4 }
+
+tunnelIfSecurity OBJECT-TYPE
+ SYNTAX INTEGER {
+ none(1), -- no security
+ ipsec(2), -- IPsec security
+ other(3)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The method used by the tunnel to secure the outer IP
+ header. The value ipsec indicates that IPsec is used
+ between the tunnel endpoints for authentication or
+ encryption or both. More specific security-related
+ information may be available in a MIB module for the
+ security protocol in use."
+ ::= { tunnelIfEntry 5 }
+
+tunnelIfTOS OBJECT-TYPE
+ SYNTAX Integer32 (-2..63)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The method used to set the high 6 bits (the
+
+ differentiated services codepoint) of the IPv4 TOS or
+ IPv6 Traffic Class in the outer IP header. A value of
+ -1 indicates that the bits are copied from the
+ payload's header. A value of -2 indicates that a
+ traffic conditioner is invoked and more information
+ may be available in a traffic conditioner MIB module.
+ A value between 0 and 63 inclusive indicates that the
+ bit field is set to the indicated value.
+
+ Note: instead of the name tunnelIfTOS, a better name
+ would have been tunnelIfDSCPMethod, but the existing
+ name appeared in RFC 2667 and existing objects cannot
+ be renamed."
+ ::= { tunnelIfEntry 6 }
+
+tunnelIfFlowLabel OBJECT-TYPE
+ SYNTAX IPv6FlowLabelOrAny
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The method used to set the IPv6 Flow Label value.
+ This object need not be present in rows where
+ tunnelIfAddressType indicates the tunnel is not over
+ IPv6. A value of -1 indicates that a traffic
+ conditioner is invoked and more information may be
+ available in a traffic conditioner MIB. Any other
+ value indicates that the Flow Label field is set to
+ the indicated value."
+ ::= { tunnelIfEntry 7 }
+
+tunnelIfAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The type of address in the corresponding
+ tunnelIfLocalInetAddress and tunnelIfRemoteInetAddress
+ objects."
+ ::= { tunnelIfEntry 8 }
+
+tunnelIfLocalInetAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The address of the local endpoint of the tunnel
+ (i.e., the source address used in the outer IP
+ header). If the address is unknown, the value is
+
+ 0.0.0.0 for IPv4 or :: for IPv6. The type of this
+ object is given by tunnelIfAddressType."
+ ::= { tunnelIfEntry 9 }
+
+tunnelIfRemoteInetAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The address of the remote endpoint of the tunnel
+ (i.e., the destination address used in the outer IP
+ header). If the address is unknown or the tunnel is
+ not a point-to-point link (e.g., if it is a 6to4
+ tunnel), the value is 0.0.0.0 for tunnels over IPv4 or
+ :: for tunnels over IPv6. The type of this object is
+ given by tunnelIfAddressType."
+ ::= { tunnelIfEntry 10 }
+
+tunnelIfEncapsLimit OBJECT-TYPE
+ SYNTAX Integer32 (-1 | 0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The maximum number of additional encapsulations
+ permitted for packets undergoing encapsulation at this
+ node. A value of -1 indicates that no limit is
+ present (except as a result of the packet size)."
+ REFERENCE "RFC 2473, section 4.1.1"
+ ::= { tunnelIfEntry 11 }
+
+tunnelConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TunnelConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "The (conceptual) table containing information on
+ configured tunnels. This table can be used to map a
+ set of tunnel endpoints to the associated ifIndex
+ value. It can also be used for row creation. Note
+ that every row in the tunnelIfTable with a fixed IPv4
+ destination address should have a corresponding row in
+ the tunnelConfigTable, regardless of whether it was
+ created via SNMP.
+
+ Since this table does not support IPv6, it is
+ deprecated in favor of tunnelInetConfigTable."
+ ::= { tunnel 2 }
+
+tunnelConfigEntry OBJECT-TYPE
+ SYNTAX TunnelConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "An entry (conceptual row) containing the information
+ on a particular configured tunnel.
+
+ Since this entry does not support IPv6, it is
+ deprecated in favor of tunnelInetConfigEntry."
+ INDEX { tunnelConfigLocalAddress,
+ tunnelConfigRemoteAddress,
+ tunnelConfigEncapsMethod,
+ tunnelConfigID }
+ ::= { tunnelConfigTable 1 }
+
+TunnelConfigEntry ::= SEQUENCE {
+ tunnelConfigLocalAddress IpAddress,
+ tunnelConfigRemoteAddress IpAddress,
+ tunnelConfigEncapsMethod IANAtunnelType,
+ tunnelConfigID Integer32,
+ tunnelConfigIfIndex InterfaceIndexOrZero,
+ tunnelConfigStatus RowStatus
+}
+
+tunnelConfigLocalAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "The address of the local endpoint of the tunnel, or
+ 0.0.0.0 if the device is free to choose any of its
+ addresses at tunnel establishment time.
+
+ Since this object does not support IPv6, it is
+ deprecated in favor of tunnelInetConfigLocalAddress."
+ ::= { tunnelConfigEntry 1 }
+
+tunnelConfigRemoteAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "The address of the remote endpoint of the tunnel.
+
+ Since this object does not support IPv6, it is
+ deprecated in favor of tunnelInetConfigRemoteAddress."
+ ::= { tunnelConfigEntry 2 }
+
+tunnelConfigEncapsMethod OBJECT-TYPE
+ SYNTAX IANAtunnelType
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "The encapsulation method used by the tunnel.
+
+ Since this object does not support IPv6, it is
+ deprecated in favor of tunnelInetConfigEncapsMethod."
+ ::= { tunnelConfigEntry 3 }
+
+tunnelConfigID OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS not-accessible
+ STATUS deprecated
+ DESCRIPTION
+ "An identifier used to distinguish between multiple
+ tunnels of the same encapsulation method, with the
+ same endpoints. If the encapsulation protocol only
+ allows one tunnel per set of endpoint addresses (such
+ as for GRE or IP-in-IP), the value of this object is
+ 1. For encapsulation methods (such as L2F) which
+ allow multiple parallel tunnels, the manager is
+ responsible for choosing any ID which does not
+ conflict with an existing row, such as choosing a
+ random number.
+
+ Since this object does not support IPv6, it is
+ deprecated in favor of tunnelInetConfigID."
+ ::= { tunnelConfigEntry 4 }
+
+tunnelConfigIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS deprecated
+ DESCRIPTION
+ "If the value of tunnelConfigStatus for this row is
+ active, then this object contains the value of ifIndex
+ corresponding to the tunnel interface. A value of 0
+ is not legal in the active state, and means that the
+ interface index has not yet been assigned.
+
+ Since this object does not support IPv6, it is
+ deprecated in favor of tunnelInetConfigIfIndex."
+ ::= { tunnelConfigEntry 5 }
+
+tunnelConfigStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS deprecated
+ DESCRIPTION
+ "The status of this row, by which new entries may be
+ created, or old entries deleted from this table. The
+ agent need not support setting this object to
+ createAndWait or notInService since there are no other
+ writable objects in this table, and writable objects
+ in rows of corresponding tables such as the
+ tunnelIfTable may be modified while this row is
+ active.
+
+ To create a row in this table for an encapsulation
+ method which does not support multiple parallel
+ tunnels with the same endpoints, the management
+ station should simply use a tunnelConfigID of 1, and
+ set tunnelConfigStatus to createAndGo. For
+ encapsulation methods such as L2F which allow multiple
+ parallel tunnels, the management station may select a
+ pseudo-random number to use as the tunnelConfigID and
+ set tunnelConfigStatus to createAndGo. In the event
+ that this ID is already in use and an
+ inconsistentValue is returned in response to the set
+ operation, the management station should simply select
+ a new pseudo-random number and retry the operation.
+
+ Creating a row in this table will cause an interface
+ index to be assigned by the agent in an
+ implementation-dependent manner, and corresponding
+ rows will be instantiated in the ifTable and the
+ tunnelIfTable. The status of this row will become
+ active as soon as the agent assigns the interface
+ index, regardless of whether the interface is
+ operationally up.
+
+ Deleting a row in this table will likewise delete the
+ corresponding row in the ifTable and in the
+ tunnelIfTable.
+
+ Since this object does not support IPv6, it is
+ deprecated in favor of tunnelInetConfigStatus."
+ ::= { tunnelConfigEntry 6 }
+
+tunnelInetConfigTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF TunnelInetConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The (conceptual) table containing information on
+ configured tunnels. This table can be used to map a
+ set of tunnel endpoints to the associated ifIndex
+ value. It can also be used for row creation. Note
+ that every row in the tunnelIfTable with a fixed
+ destination address should have a corresponding row in
+ the tunnelInetConfigTable, regardless of whether it
+ was created via SNMP."
+ ::= { tunnel 3 }
+
+tunnelInetConfigEntry OBJECT-TYPE
+ SYNTAX TunnelInetConfigEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An entry (conceptual row) containing the information
+ on a particular configured tunnel. Note that there is
+ a 128 subid maximum for object OIDs. Implementers
+ need to be aware that if the total number of octets in
+ tunnelInetConfigLocalAddress and
+ tunnelInetConfigRemoteAddress exceeds 110 then OIDs of
+ column instances in this table will have more than 128
+ sub-identifiers and cannot be accessed using SNMPv1,
+ SNMPv2c, or SNMPv3. In practice this is not expected
+ to be a problem since IPv4 and IPv6 addresses will not
+ cause the limit to be reached, but if other types are
+ supported by an agent, care must be taken to ensure
+ that the sum of the lengths do not cause the limit to
+ be exceeded."
+ INDEX { tunnelInetConfigAddressType,
+ tunnelInetConfigLocalAddress,
+ tunnelInetConfigRemoteAddress,
+ tunnelInetConfigEncapsMethod,
+ tunnelInetConfigID }
+ ::= { tunnelInetConfigTable 1 }
+
+TunnelInetConfigEntry ::= SEQUENCE {
+ tunnelInetConfigAddressType InetAddressType,
+ tunnelInetConfigLocalAddress InetAddress,
+ tunnelInetConfigRemoteAddress InetAddress,
+ tunnelInetConfigEncapsMethod IANAtunnelType,
+ tunnelInetConfigID Integer32,
+ tunnelInetConfigIfIndex InterfaceIndexOrZero,
+ tunnelInetConfigStatus RowStatus,
+ tunnelInetConfigStorageType StorageType
+}
+
+tunnelInetConfigAddressType OBJECT-TYPE
+ SYNTAX InetAddressType
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The address type over which the tunnel encapsulates
+ packets."
+ ::= { tunnelInetConfigEntry 1 }
+
+tunnelInetConfigLocalAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The address of the local endpoint of the tunnel, or
+ 0.0.0.0 (for IPv4) or :: (for IPv6) if the device is
+ free to choose any of its addresses at tunnel
+ establishment time."
+ ::= { tunnelInetConfigEntry 2 }
+
+tunnelInetConfigRemoteAddress OBJECT-TYPE
+ SYNTAX InetAddress
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The address of the remote endpoint of the tunnel."
+ ::= { tunnelInetConfigEntry 3 }
+
+tunnelInetConfigEncapsMethod OBJECT-TYPE
+ SYNTAX IANAtunnelType
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "The encapsulation method used by the tunnel."
+ ::= { tunnelInetConfigEntry 4 }
+
+tunnelInetConfigID OBJECT-TYPE
+ SYNTAX Integer32 (1..2147483647)
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "An identifier used to distinguish between multiple
+ tunnels of the same encapsulation method, with the
+ same endpoints. If the encapsulation protocol only
+ allows one tunnel per set of endpoint addresses (such
+ as for GRE or IP-in-IP), the value of this object is
+ 1. For encapsulation methods (such as L2F) which
+ allow multiple parallel tunnels, the manager is
+ responsible for choosing any ID which does not
+
+ conflict with an existing row, such as choosing a
+ random number."
+ ::= { tunnelInetConfigEntry 5 }
+
+tunnelInetConfigIfIndex OBJECT-TYPE
+ SYNTAX InterfaceIndexOrZero
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "If the value of tunnelInetConfigStatus for this row
+ is active, then this object contains the value of
+ ifIndex corresponding to the tunnel interface. A
+ value of 0 is not legal in the active state, and means
+ that the interface index has not yet been assigned."
+ ::= { tunnelInetConfigEntry 6 }
+
+tunnelInetConfigStatus OBJECT-TYPE
+ SYNTAX RowStatus
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The status of this row, by which new entries may be
+ created, or old entries deleted from this table. The
+ agent need not support setting this object to
+ createAndWait or notInService since there are no other
+ writable objects in this table, and writable objects
+ in rows of corresponding tables such as the
+ tunnelIfTable may be modified while this row is
+ active.
+
+ To create a row in this table for an encapsulation
+ method which does not support multiple parallel
+ tunnels with the same endpoints, the management
+ station should simply use a tunnelInetConfigID of 1,
+ and set tunnelInetConfigStatus to createAndGo. For
+ encapsulation methods such as L2F which allow multiple
+ parallel tunnels, the management station may select a
+ pseudo-random number to use as the tunnelInetConfigID
+ and set tunnelInetConfigStatus to createAndGo. In the
+ event that this ID is already in use and an
+ inconsistentValue is returned in response to the set
+ operation, the management station should simply select
+ a new pseudo-random number and retry the operation.
+
+ Creating a row in this table will cause an interface
+ index to be assigned by the agent in an
+ implementation-dependent manner, and corresponding
+ rows will be instantiated in the ifTable and the
+
+ tunnelIfTable. The status of this row will become
+ active as soon as the agent assigns the interface
+ index, regardless of whether the interface is
+ operationally up.
+
+ Deleting a row in this table will likewise delete the
+ corresponding row in the ifTable and in the
+ tunnelIfTable."
+ ::= { tunnelInetConfigEntry 7 }
+
+tunnelInetConfigStorageType OBJECT-TYPE
+ SYNTAX StorageType
+ MAX-ACCESS read-create
+ STATUS current
+ DESCRIPTION
+ "The storage type of this row. If the row is
+ permanent(4), no objects in the row need be writable."
+ ::= { tunnelInetConfigEntry 8 }
+
+-- conformance information
+
+tunnelMIBConformance
+ OBJECT IDENTIFIER ::= { tunnelMIB 2 }
+tunnelMIBCompliances
+ OBJECT IDENTIFIER ::= { tunnelMIBConformance 1 }
+tunnelMIBGroups OBJECT IDENTIFIER ::= { tunnelMIBConformance 2 }
+
+-- compliance statements
+
+tunnelMIBCompliance MODULE-COMPLIANCE
+ STATUS deprecated
+ DESCRIPTION
+ "The (deprecated) IPv4-only compliance statement for
+ the IP Tunnel MIB.
+
+ This is deprecated in favor of
+ tunnelMIBInetFullCompliance and
+ tunnelMIBInetReadOnlyCompliance."
+ MODULE -- this module
+ MANDATORY-GROUPS { tunnelMIBBasicGroup }
+
+ OBJECT tunnelIfHopLimit
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT tunnelIfTOS
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT tunnelConfigStatus
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ ::= { tunnelMIBCompliances 1 }
+
+tunnelMIBInetFullCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The full compliance statement for the IP Tunnel MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS { tunnelMIBInetGroup }
+
+ OBJECT tunnelIfAddressType
+ SYNTAX InetAddressType { ipv4(1), ipv6(2),
+ ipv4z(3), ipv6z(4) }
+ DESCRIPTION
+ "An implementation is only required to support IPv4
+ and/or IPv6 addresses. An implementation only needs to
+ support the addresses it actually supports on the
+ device."
+ ::= { tunnelMIBCompliances 2 }
+
+tunnelMIBInetReadOnlyCompliance MODULE-COMPLIANCE
+ STATUS current
+ DESCRIPTION
+ "The read-only compliance statement for the IP Tunnel
+ MIB."
+ MODULE -- this module
+ MANDATORY-GROUPS { tunnelMIBInetGroup }
+
+ OBJECT tunnelIfHopLimit
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT tunnelIfTOS
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT tunnelIfFlowLabel
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT tunnelIfAddressType
+ SYNTAX InetAddressType { ipv4(1), ipv6(2),
+ ipv4z(3), ipv6z(4) }
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required.
+
+ An implementation is only required to support IPv4
+ and/or IPv6 addresses. An implementation only needs to
+ support the addresses it actually supports on the
+ device."
+
+ OBJECT tunnelIfLocalInetAddress
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT tunnelIfRemoteInetAddress
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT tunnelIfEncapsLimit
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+
+ OBJECT tunnelInetConfigStatus
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required, and active is the only
+ status that needs to be supported."
+
+ OBJECT tunnelInetConfigStorageType
+ MIN-ACCESS read-only
+ DESCRIPTION
+ "Write access is not required."
+ ::= { tunnelMIBCompliances 3 }
+
+-- units of conformance
+
+tunnelMIBBasicGroup OBJECT-GROUP
+ OBJECTS { tunnelIfLocalAddress, tunnelIfRemoteAddress,
+ tunnelIfEncapsMethod, tunnelIfHopLimit, tunnelIfTOS,
+ tunnelIfSecurity, tunnelConfigIfIndex, tunnelConfigStatus }
+ STATUS deprecated
+ DESCRIPTION
+ "A collection of objects to support basic management
+
+ of IPv4 Tunnels. Since this group cannot support
+ IPv6, it is deprecated in favor of
+ tunnelMIBInetGroup."
+ ::= { tunnelMIBGroups 1 }
+
+tunnelMIBInetGroup OBJECT-GROUP
+ OBJECTS { tunnelIfAddressType, tunnelIfLocalInetAddress,
+ tunnelIfRemoteInetAddress, tunnelIfEncapsMethod,
+ tunnelIfEncapsLimit,
+ tunnelIfHopLimit, tunnelIfTOS, tunnelIfFlowLabel,
+ tunnelIfSecurity, tunnelInetConfigIfIndex,
+ tunnelInetConfigStatus, tunnelInetConfigStorageType }
+ STATUS current
+ DESCRIPTION
+ "A collection of objects to support basic management
+ of IPv4 and IPv6 Tunnels."
+ ::= { tunnelMIBGroups 2 }
+
+END