1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
|
CHANGES.txt - 1.6.2 - 2013-03-18
--------------------------------
CHANGES IN CUPS V1.6.2
- Documentation fixes (STR #4229, STR #4239, STR #4234, STR #4248,
STR #4259)
- Security: All file, directory, user, and group settings are now stored
in a separate cups-files.conf configuration file that cannot be set
through the CUPS web interface or APIs (STR #4223)
- Added a Czech localization (STR #4201)
- Added a French localization (STR #4247)
- Added a Russian localization (STR #4228, STR #4285)
- Updated the Catalan localization (STR #4202)
- Local certificate authentication did not guard against an empty
certification file (STR #4293)
- The scheduler did not reject device URIs with spaces.
- Added USB quirk rule for Epson Stylus Photo 750 (STR #4286)
- The IPP backend could crash if the printer disconnects early
(STR #4284)
- cupsGetPPD did not work with statically-configured CUPS shared
queues (STR #4178)
- The scheduler did not support long MIME media types (STR #4270)
- The cupsfilter command did not set the CHARSET environment variable
for the text filters (STR #4273)
- The lp command did not show errors for unknown "--foo" (STR #4261)
- Bad IPP responses could crash ipptool (STR #4262)
- Updated USB quirk rules for Canon and Xerox printers (STR #4217,
STR #4263)
- Added USB blacklisting for printers that require a custom backend
(STR #4218)
- The PPD compiler did not correctly JCL options (STR #4115, STR #4203)
- The ipptool program now supports DEFINE-MATCH and DEFINE-NO-MATCH
predicates for STATUS directives.
- Fixed a problem with local Kerberos authentication (STR #4140)
- Coverity scan: fixed some minor issues (STR #4242)
- The scheduler did not remove color profiles after deleting a printer
(STR #4232, STR #4276)
- The CUPS library did not always detect a timed out connection to the
server which could cause temporary loss of printing from applications
(STR #4187)
- The ipptool program now supports variable substitution in OPERATION
and DELAY directives (STR #4175)
- The IPP backend now stops queues when the server configuration
prevents successful job submission (STR #4125)
- The XML output of ipptool contained empty dictionaries (STR #4136)
- The scheduler did not delete job control backup files (STR #4244)
- cupsGetPPD3 could return a local PPD instead of the correct remote
PPD.
- The scheduler incorrectly advertised auth-info-required for local
queues needing local authentication (STR #4205)
- CUPS 1.6 clients using the ServerName directive in client.conf did not
work with CUPS 1.3.x or older servers (STR #4231, STR #4291)
- The SNMP backend now tries to work around broken printers that use a
newline to separate key/value pairs.
- The IPP backend did not send a cancel request to printers when a job
was canceled and the printer did not support Create-Job.
- Fixed EPM packaging files (STR #4199)
- OpenBSD build fix (STR #4195, STR #4196, STR #4197)
- The scheduler could crash when using Avahi (STR #4183, STR #4192,
STR #4200, STR #4213)
- The IPP backend could get stuck in an endless loop on certain network
errors (STR #4194)
- 32-bit builds failed on Debian (STR #4133)
- The scheduler no longer accepts or sends job description attributes.
- The IPP backend now works around some conformance issues for broken
printers (STR #4190)
- cupsBackendReport() now filters out all control characters from the
reported 1284 device IDs (STR #4124)
- The scheduler no longer allows job-name values that are not valid
network Unicode strings (STR #4072)
- The web interface did not preserve the order of classes, jobs, or
printers (STR #4170)
- The network backends now support disabling of SNMP supply level
queries via the "snmp" URI option (STR #4106)
- The IPP backend did not specify the compression used (STR #4181)
- ipptool did not support octetString values.
- The scheduler did not recognize dnssd: or ipps: URIs as Bonjour shared
queues (STR #4158)
- Applications could not get the PPD file for statically-configured
Bonjour-shared print queues (STR #4159)
- The cupsd.conf file included obsolete browsing directives (STR #4157)
- Fixed a USB backend compatibility issue on systems using libusb
(STR #4155, STR #4191)
- Some Bonjour features were not available on systems with Avahi
(STR #4156)
- CUPS now includes the port number in the Host: header for HTTP
requests.
- Fixed REPEAT-MATCH for STATUS and EXPECT - was incorrectly erroring
out.
CHANGES IN CUPS V1.6.1
- Documentation fix (STR #4149)
- RPM packaging fixes (STR #4129, #4145)
- The Japanese and English web interface headers were swapped
(STR #4148)
CHANGES IN CUPS V1.6.0
- Document changes (STR #4131)
- Added new Catalan (STR #4107) and Spanish (STR #4137) localizations.
CHANGES IN CUPS V1.6rc1
- Added a new Japanese localization (STR #4122)
- The SNMP backend no longer exits if it is unable to obtain an IPv6
socket (STR #4109)
- The LPD backend incorrectly used "localhost" in the control file
instead of the current hostname.
CHANGES IN CUPS V1.6b1
- Documentation updates (STR #3927, STR #3980, STR #4010, STR #4068)
- The scheduler now consolidates all PPD updates from filters at the
end of the job (STR #4075)
- CUPS now supports color management using colord (STR #3808)
- CUPS now supports Bonjour using Avahi (STR #3066)
- The PreserveJobFiles and PreserveJobHistory directives now support
specification of a time interval (STR #3143)
- PPD files can now be archived in (gzip'd) tar files to further reduce
the disk space used by PPD files (STR #3772)
- The network backends now deal with printers that report their levels
in percent but do not specify a maximum capacity of 100 (STR #3551)
- The network backends now report full/almost-full waste bins in
printers along with end-of-life for cleaning pads (STR #4017)
- Added a configure option to set the permissions of the installed
cupsd (STR #3459)
- Added a new WITH-ALL-VALUES directive to ipptool EXPECT predicates
(STR #3949)
- CUPS now supports a User directive in client.conf and the CUPS_USER
environment variable for overriding the default username (STR #3114)
- Now set the PJL USERNAME variable as needed (STR #3100)
- Added support for usernames and passwords longer than 32 characters
(STR #2856)
- Added a new MaxHoldTime directive to automatically cancel jobs that
have been held indefinitely after a specific number of seconds
(STR #2291)
- The LPD backend now uses the originating host name when it is not the
local system (STR #2053)
- CUPS now prefers the suffix "dpcm" when reporting resolution in dots-
per-centimeter (STR #4006)
- The configure script and build system no longer support building of
separate 32-bit and 64-bit libraries.
- The "brightness", "columns", "fitplot", "gamma", "hue",
"natural-scaling", "penwidth", "position", "ppi", "saturation", and
"scaling" options are not longer supported (STR #4010)
- The "page-bottom", "page-left", "page-right", "page-top",
"prettyprint", and "wrap" options have been deprecated (STR #4010)
- The scheduler now reports the standard "number-of-documents" attribute
instead of the CUPS-specific "document-count" attribute in
job objects.
- Added new destination connection and enumeration functions (STR #3924)
- Added new option, localization, and job submission functions that do
not depend on PPD files (STR #3925)
- Added a new MaxJobTime directive for cupsd that specifies the maximum
amount of time allowed for a job to complete before it is canceled.
- The default password callback now supports passwords up to 127
characters.
- The scheduler now supports a DefaultAuthType of "auto" to
automatically choose between Basic (username/password) and Negotiate
(Kerberos) authentication.
- cupsSideChannelSNMPGet/Walk now support OIDs and values up to 64k in
length.
- CUPS no longer supports automatic remote printers or implicit classes
via the CUPS, LDAP, or SLP protocols (STR #3922, STR #3923)
- The PPD APIs are now deprecated and will be removed in a future
version of CUPS (STR #3927)
- The default IPP version for requests is now 2.0 (STR #3929)
- The IPP APIs no longer expose the ipp_t or ipp_attribute_t structures
and instead provide accessor functions (STR #3928)
- The scheduler will no longer run programs with group write permission.
- The PHP module has been removed (STR #3932)
- The bannertops, commandtoescpx, commandtopclx, imagetops,
imagetoraster, pdftops, rastertoescpx, rastertopclx, and texttops
filters have been removed (STR #3930)
- The serial and parallel backends have been removed (STR 3935)
|